    Benchmark Analysis on Loss-of-Flow-without-Scram Test of FFTF Using Refined SAC-3D Models

    by Siyu Lyu, Daogang Lu, Danting Sui

    The Fast Flux Test Facility (FFTF) is a liquid sodium-cooled nuclear reactor designed by the Westinghouse Electric Corporation for the U.S. Department of Energy. In July 1986, a series of unprotected transients were performed to demonstrate the passive safety of FFTF. Among these, a total of 13 loss-of-flow-without scram (LOFWOS) tests were conducted to confirm the liquid metal reactor safety margins, provide data for computer code validation, and demonstrate the inherent and passive safety benefits of specific design features. In our preliminary work, we have performed relatively coarse modeling of the FFTF. To better predict the transient behavior of FFTF LOFWOS test #13, we modeled it using a more refined thermal-hydraulics model. In this paper, we simulate FFTF LOFWOS test #13 with the system safety analysis code SAC-3D according to the benchmark specifications provided by Argonne National Laboratory (ANL). The simulation range includes the primary and secondary circuits. The reactor core was modeled by the built-in 3D neutronics calculation module and the parallel-channel thermal-hydraulics calculation module. To better predict the reactivity feedback introduced by coolant level variations within the GEMs, a real-time macro cross-section homogenization processing module was developed. The steady-state power distribution was calculated as the transient simulation initial boundary conditions. In general, both the steady-state calculation results and the whole-plant transient behavior predictions are in good agreement with the measured data. The relatively large deviations in transient simulation occur in the outlet temperature predictions of the PIOTA in row 6. It can be preliminarily explained by the reason for neglecting the heat transfer between channels in this model.


  • Open Access

    Code to Code Validation of SAC-3D Based on EBR-II Benchmark Problem

    by Lu Daogang, Siyu Lyu, Danting Sui

    Neutronics calculation model plays a very important role in applying a specify simulation of a reactor system. The accuracy of the reactor core neutronics calculation results can hugely affect the final results of the reactor system analysis. At present, most of the system analysis codes apply the point reactor kinetics calculation model as the method to do the neutronics

  • Open Access

    Preliminary Development on Thermal-Hydraulic Analysis Code for the Spent Fuel Rod Under the Condition of Spray Cooling

    by Chao Guo, Deng Jian, Lili Liu, Yugao Ma, Yuhao Zhang, Siyu Lyu, Rong Cai

    Since the Fukushima accident, the safety of spent fuel pool attracts more and more attention. As the feed water system of spent fuel pool fails to work, coolant in the spent fuel pool rises with water level in the pool dropping. As a result of this phenomenon, spent fuel assemblies are exposed to the atmosphere and maybe melt with leakage of radioactive fission products. It is