Ryan Marks
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ryan Marks has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Haitao Zheng
School of Mathematics, Southwest Jiaotong University, Chengdu, China
2 shared publications - Mohammad Osman Tokhi
London South Bank University
2 shared publications - Bin Wang
Department of Mechanical and Aerospace Engineering, Brunel University of London, Uxbridge UB8 3PH, UK
1 shared publication - Dandan Liu
TWI Ltd., Granta Park, Great Abington, Cambridge CB21 6AL, UK
1 shared publication - Gholamhossein Shirkoohi
School of Engineering, London South Bank University, London SE1 0AA, UK
1 shared publication - Han Yang
TWI Ltd., Granta Park, Great Abington, Cambridge CB21 6AL, UK
1 shared publication
Latest Publications
- Open Access
Acoustic Emission Source Location Using Finite Element Generated Delta-T Mapping
One of the most significant benefits of Acoustic Emission (AE) testing over other Non-Destructive Evaluation (NDE) techniques lies in its damage location capability over a wide area. The delta-T mapping technique developed by researchers has been shown to enable AE source location to a high level of accuracy in complex structures. However, the time-consuming and laborious data training process of the delta-T mapping technique has prevented this technique from large-scale application on large complex structures. In order to solve this problem, a Finite Element (FE) method was applied to model training data for localization of experimental AE events on a complex plate. Firstly, the FE model was validated through demonstrating consistency between simulated data and the experimental data in the study of Hsu-Nielsen (H-N) sources on a simple plate. Then, the FE model with the same parameters was applied to a planar location problem on a complex plate. It has been demonstrated that FE generated delta-T mapping data can achieve a reasonable degree of source location accuracy with an average error of 3.88 mm whilst decreasing the time and effort required for manually collecting and processing the training data.
Open AccessAcoustic Emission Source Location Using Finite Element Generated Delta-T Mapping
One of the most significant benefits of Acoustic Emission (AE) testing over other Non-Destructive Evaluation (NDE) techniques lies in its damage location capability over a wide area. The delta-T mapping technique developed by researchers has been shown to enable AE source location to a high level of accuracy in complex structures. However, the time-consuming and laborious data training process of the delta-T mapping technique has prevented this technique from large-scale application on large complex structures. In order to solve this problem, a Finite Element (FE) method was applied to model training data for localization of experimental AE events on a complex plate. Firstly, the FE model was validated through demonstrating consistency between simulated data and the experimental data in the study of Hsu-Nielsen (H-N) sources on a simple plate. Then, the FE model with the same parameters was applied to a planar location problem on a complex plate. It has been demonstrated that FE generated delta-T mapping data can achieve a reasonable degree of source location accuracy with an average error of 3.88 mm whilst decreasing the time and effort required for manually collecting and processing the training data.
- Open Access
- 15 February 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (4) , 2005
Defect Recognition of Roll-to-Roll Printed Conductors Using Dark Lock-in Thermography and Localized Segmentation
The demand for flexible large area optoelectronic devices such as organic light-emitting diodes (OLEDs) and organic photovoltaics (OPVs) is growing. Roll-to-roll (R2R) printing enables cost-efficient industrial production of optoelectronic devices. The performance of electronic devices may significantly suffer from local electrical defects. The dark lock-in infrared thermography (DLIT) method is an effective non-destructive testing (NDT) tool to identify such defects as hot spots. In this study, a DLIT inspection system was applied to visualize the defects of R2R printed silver conductors on flexible plastic substrates. A two-stage automated defect recognition (ADR) methodology was proposed to detect and localize two types of typical electrical defects, which are caused by complete or partial breaks on the printed conductive wires, based on localized segmentation and thresholding methods.
- 15 February 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (4) , 2005
Open AccessDefect Recognition of Roll-to-Roll Printed Conductors Using Dark Lock-in Thermography and Localized Segmentation
The demand for flexible large area optoelectronic devices such as organic light-emitting diodes (OLEDs) and organic photovoltaics (OPVs) is growing. Roll-to-roll (R2R) printing enables cost-efficient industrial production of optoelectronic devices. The performance of electronic devices may significantly suffer from local electrical defects. The dark lock-in infrared thermography (DLIT) method is an effective non-destructive testing (NDT) tool to identify such defects as hot spots. In this study, a DLIT inspection system was applied to visualize the defects of R2R printed silver conductors on flexible plastic substrates. A two-stage automated defect recognition (ADR) methodology was proposed to detect and localize two types of typical electrical defects, which are caused by complete or partial breaks on the printed conductive wires, based on localized segmentation and thresholding methods.
- Open Access
- 20 January 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (3) , 1037
Development of Permanently Installed Magnetic Eddy Current Sensor for Corrosion Monitoring of Ferromagnetic Pipelines
Permanently installed sensors are a cost-effective solution for corrosion monitoring due to their advantages, such as less human interference and continuous data acquisition. Some of the most widely used permanently installed corrosion sensors are ultrasonic thickness (UT) gauges. However, UT sensors are limited by the need for coupling agents between pipe surfaces and sensors. The magnetic eddy current (MEC) method, on the other hand, does not require couplant and can be used over insulations. With the development of powerful rare earth magnets, MEC sensors with low power consumption are possible, and there is the prospect of using them as permanently installed sensors. A novel wireless magnetic eddy current sensor has been designed and optimized using finite element simulation. Sensitivity studies of the sensors reveal that the excitation frequency is a critical parameter for the detection of corrosion defects. An in-depth explanation of the relationship between the sensitivity of the sensor and the excitation frequency is presented in this paper. The results of an accelerated corrosion test, conducted to simulate the service environment of the sensor, are also discussed. It was observed that the sensor signals are very sensitive to corrosion defects and show no subtle differences due to temperature and humidity changes.
- 20 January 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (3) , 1037
Open AccessDevelopment of Permanently Installed Magnetic Eddy Current Sensor for Corrosion Monitoring of Ferromagnetic Pipelines
Permanently installed sensors are a cost-effective solution for corrosion monitoring due to their advantages, such as less human interference and continuous data acquisition. Some of the most widely used permanently installed corrosion sensors are ultrasonic thickness (UT) gauges. However, UT sensors are limited by the need for coupling agents between pipe surfaces and sensors. The magnetic eddy current (MEC) method, on the other hand, does not require couplant and can be used over insulations. With the development of powerful rare earth magnets, MEC sensors with low power consumption are possible, and there is the prospect of using them as permanently installed sensors. A novel wireless magnetic eddy current sensor has been designed and optimized using finite element simulation. Sensitivity studies of the sensors reveal that the excitation frequency is a critical parameter for the detection of corrosion defects. An in-depth explanation of the relationship between the sensitivity of the sensor and the excitation frequency is presented in this paper. The results of an accelerated corrosion test, conducted to simulate the service environment of the sensor, are also discussed. It was observed that the sensor signals are very sensitive to corrosion defects and show no subtle differences due to temperature and humidity changes.
- Open Access
- 12 November 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (22) , 10700
Dynamic Wind Turbine Blade Inspection Using Micro-Polarisation Spatial Phase Shift Digital Shearography
Shearography, as a novel non-destructive evaluation technique, has shown notable ability in the detection of composite materials. However, in current shearography practices, the phase shifting and loading methods applied are mainly static. For instance, vacuum hood or force loading facilities are often used in phase-shifting shearography, and these are hard to realise with robotic control, especially for on-board inspection. In this study, a dynamic process for detecting defects in the subsurface of a wind turbine blade (WTB) using spatial phase shift with dynamic thermal loading was proposed. The WTB sample underwent a dynamic thermal loading operation, and its status is captured by a Michelson interferometric-based spatial phase shift digital shearography system using a pixelated micro-polarisation array sensor. The captured images were analysed in a 2D frequency domain and low-pass filtered for phase map acquisition. The initial phase maps underwent a window Fourier filtering process and were integrated to produce a video sequence for realisation of visualising the first derivative of the displacement in the process of thermal loading. The approach was tested in experimental settings and the results obtained were presented and discussed. A comparative assessment of the approach with shearography fringe pattern analysis and temporal phase shift technique is also presented and discussed.
- 12 November 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (22) , 10700
Open AccessDynamic Wind Turbine Blade Inspection Using Micro-Polarisation Spatial Phase Shift Digital Shearography
Shearography, as a novel non-destructive evaluation technique, has shown notable ability in the detection of composite materials. However, in current shearography practices, the phase shifting and loading methods applied are mainly static. For instance, vacuum hood or force loading facilities are often used in phase-shifting shearography, and these are hard to realise with robotic control, especially for on-board inspection. In this study, a dynamic process for detecting defects in the subsurface of a wind turbine blade (WTB) using spatial phase shift with dynamic thermal loading was proposed. The WTB sample underwent a dynamic thermal loading operation, and its status is captured by a Michelson interferometric-based spatial phase shift digital shearography system using a pixelated micro-polarisation array sensor. The captured images were analysed in a 2D frequency domain and low-pass filtered for phase map acquisition. The initial phase maps underwent a window Fourier filtering process and were integrated to produce a video sequence for realisation of visualising the first derivative of the displacement in the process of thermal loading. The approach was tested in experimental settings and the results obtained were presented and discussed. A comparative assessment of the approach with shearography fringe pattern analysis and temporal phase shift technique is also presented and discussed.