Rodrigo de Lima Amaral
Rodrigo de Lima Amaral has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Bernardo Luiz Harry Diniz Lemos
Escola Politécnica da Universidade de São Paulo (EP USP)
4 shared publications - Helder Lima de Moura
University of Campinas
4 shared publications - Julio Romano Meneghini
Department of Mechanical Engineering, Polytechnic School of the University of São Paulo, São Paulo, Brazil
4 shared publications - Vítor Augusto Andreghetto Bortolin
Escola Politécnica da Universidade de São Paulo (EP USP)
4 shared publications - Guilherme José de Castilho
University of Campinas
3 shared publications - Idágene Aparecida Cestari
Instituto Do Coracao, Hospital das Clinicas HCFMUSP, Universidade de Sao Paulo
2 shared publications
Latest Publications
- 1 September 2026
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 147 (9) , 095026
Volume-constrained wall motion alters left atrial appendage hemodynamic descriptors: a CFD sensitivity study
Volume-constrained wall motion alters left atrial appendage hemodynamic descriptors: a CFD sensitivity study, Lameu Silva Junior, João, Maranho, Júlio Gallinaro, de Lima Amaral, Rodrigo Volume-constrained wall motion alters left atrial appendage hemodynamic descriptors: a CFD sensitivity study, Lameu Silva Junior, João, Maranho, Júlio Gallinaro, de Lima Amaral, Rodrigo
- 1 September 2026
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 147 (9) , 095026
Volume-constrained wall motion alters left atrial appendage hemodynamic descriptors: a CFD sensitivity study
Volume-constrained wall motion alters left atrial appendage hemodynamic descriptors: a CFD sensitivity study, Lameu Silva Junior, João, Maranho, Júlio Gallinaro, de Lima Amaral, Rodrigo Volume-constrained wall motion alters left atrial appendage hemodynamic descriptors: a CFD sensitivity study, Lameu Silva Junior, João, Maranho, Júlio Gallinaro, de Lima Amaral, Rodrigo
- 18 August 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (33) , 335403
Single-frame dynamic PIV mask generation based on local particles per pixel distribution
In practical particle image velocimetry (PIV) applications, severe noise and dynamic optical artifacts—such as sharp shadows, intense specular reflections, transient occlusions, and non-uniform illumination—critically degrade particle-to-background separation and yield regions with highly unreliable correlation peaks. Under these extreme conditions, dynamic mask generation is essential to restrict the interrogation to the physically valid domain and to suppress spurious vectors. This work introduces a robust dynamic masking method based on the local particles-per-pixel (ppp) distribution, derived entirely from a single frame. This single-frame architecture makes the method applicable even when stationary-background assumptions are untenable or long time series are unavailable. The proposed pipeline comprises (i) an optional algorithmically simple pre-processing, (ii) tracer identification, (iii) spatial aggregation to construct the ppp field, (iv) smoothing and segmentation, and (v) morphological corrections for boundary refinement. A controlled synthetic analysis isolates typical degradation mechanisms and provides an objective basis for parameter selection. Finally, the approach is stress-tested on three highly noisy, dynamic experimental cases: a pediatric ventricular assist device, a multiphase bubble column, and the undulating boundary of an anguilliform swimming fish. The proposed pipeline is quantitatively benchmarked against the standard peak correlation energy (PCE) masking approach. Results demonstrate that while the PCE approach fails in regions of severe shadowing and continuous boundary deformation, the single-frame ppp method systematically isolates these optical failures. Evaluations of the probability density functions of the primary peak ratio confirm that the proposed mask substantially reduces low- signal-to-noise ratio spurious vectors, significantly enhancing global correlation fidelity while maintaining stable frame-by-frame application after parameter selection.
- 18 August 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (33) , 335403
Single-frame dynamic PIV mask generation based on local particles per pixel distribution
In practical particle image velocimetry (PIV) applications, severe noise and dynamic optical artifacts—such as sharp shadows, intense specular reflections, transient occlusions, and non-uniform illumination—critically degrade particle-to-background separation and yield regions with highly unreliable correlation peaks. Under these extreme conditions, dynamic mask generation is essential to restrict the interrogation to the physically valid domain and to suppress spurious vectors. This work introduces a robust dynamic masking method based on the local particles-per-pixel (ppp) distribution, derived entirely from a single frame. This single-frame architecture makes the method applicable even when stationary-background assumptions are untenable or long time series are unavailable. The proposed pipeline comprises (i) an optional algorithmically simple pre-processing, (ii) tracer identification, (iii) spatial aggregation to construct the ppp field, (iv) smoothing and segmentation, and (v) morphological corrections for boundary refinement. A controlled synthetic analysis isolates typical degradation mechanisms and provides an objective basis for parameter selection. Finally, the approach is stress-tested on three highly noisy, dynamic experimental cases: a pediatric ventricular assist device, a multiphase bubble column, and the undulating boundary of an anguilliform swimming fish. The proposed pipeline is quantitatively benchmarked against the standard peak correlation energy (PCE) masking approach. Results demonstrate that while the PCE approach fails in regions of severe shadowing and continuous boundary deformation, the single-frame ppp method systematically isolates these optical failures. Evaluations of the probability density functions of the primary peak ratio confirm that the proposed mask substantially reduces low- signal-to-noise ratio spurious vectors, significantly enhancing global correlation fidelity while maintaining stable frame-by-frame application after parameter selection.
- 11 May 2023
- Published by Springer Nature
- p. 193-207
Estimation of the Energy Dissipation Rate in a Stirred Tank by 2D PIV Measurements
- 11 May 2023
- Published by Springer Nature
- p. 193-207
Estimation of the Energy Dissipation Rate in a Stirred Tank by 2D PIV Measurements
- 22 August 2022
- Published by Springer Nature in Journal of the Brazilian Society of Mechanical Sciences and Engineering
- Vol. 44 (9) , 1-17
Comparison of PIV measurements and OpenFOAM simulations of a stirred tank: study of the azimuthal position effect
- 22 August 2022
- Published by Springer Nature in Journal of the Brazilian Society of Mechanical Sciences and Engineering
- Vol. 44 (9) , 1-17
Comparison of PIV measurements and OpenFOAM simulations of a stirred tank: study of the azimuthal position effect
- Open Access
- 30 June 2022
- Published by Editoriales Iberoamericanos in Revista Ibero-Americana de Ciências Ambientais
- Vol. 13 (6) , 204-215
Use of rain water in floor washing and garden irrigation: a case study
The socioeconomic context brought by the COVID-19 pandemic and the war in Ukraine, caused a crisis in the world economy. Faced with this situation of inflation and the rise of the dollar, access to basic items such as water and cooking gas has become an obstacle for the needy population. There are alternatives to overcome water scarcity, and one of them is the use of water harvesting systems with low-cost technologies, which facilitate replication in environments that do not have a water distribution network, allowing the economically disadvantaged population access the water. This work analyzes the use of rainwater in garden irrigation and floor washing in a public building. The case study was carried out at the Civil Court and Consumer Relations Court in Camaragibe, PE. The rainfall index and the history of water consumption were analyzed, as well as the analysis of rainwater in the study region. Reservoir simulations and economic analysis were performed using the NETUNO software. The economic simulation resulted in the value of R$3,000.00 (three thousand reais), and a payback time of 5 years. After analyzing the simulations and the results of the rainwater samples, as well as complying with the requirements of the ABNT 15527/2019 standard, it can be inferred that the implementation of rainwater harvesting for non-potable use is feasible.Keywords: Harvesting rainwater. Sustainability. Low cost technology.
- 30 June 2022
- Published by Editoriales Iberoamericanos in Revista Ibero-Americana de Ciências Ambientais
- Vol. 13 (6) , 204-215
Open AccessUse of rain water in floor washing and garden irrigation: a case study
The socioeconomic context brought by the COVID-19 pandemic and the war in Ukraine, caused a crisis in the world economy. Faced with this situation of inflation and the rise of the dollar, access to basic items such as water and cooking gas has become an obstacle for the needy population. There are alternatives to overcome water scarcity, and one of them is the use of water harvesting systems with low-cost technologies, which facilitate replication in environments that do not have a water distribution network, allowing the economically disadvantaged population access the water. This work analyzes the use of rainwater in garden irrigation and floor washing in a public building. The case study was carried out at the Civil Court and Consumer Relations Court in Camaragibe, PE. The rainfall index and the history of water consumption were analyzed, as well as the analysis of rainwater in the study region. Reservoir simulations and economic analysis were performed using the NETUNO software. The economic simulation resulted in the value of R$3,000.00 (three thousand reais), and a payback time of 5 years. After analyzing the simulations and the results of the rainwater samples, as well as complying with the requirements of the ABNT 15527/2019 standard, it can be inferred that the implementation of rainwater harvesting for non-potable use is feasible.Keywords: Harvesting rainwater. Sustainability. Low cost technology.
- 15 May 2022
- Published by Wiley in Artificial Organs
- Vol. 46 (9) , 1833-1846
Effect of the bileaflet inlet valve angle on the flow of a pediatric ventricular assist device: Experimental analysis
Background: Mechanical heart valves (MHV) and its fluid dynamics inside a pulsatile pediatric ventricular assist device (PVAD) can be associated with blood degradation. In this article, flow structures are analyzed and compared by an experimental investigation on the effect of bileaflet MHV positioned at varying angles in the inlet port orifice of a PVAD.Methods: Time‐resolved particle image velocimetry was applied to characterize the internal flow of the device. St Jude Medical bileaftlet valves were used on the inlet orifice and positioned at 0°, 15°, 30°, 45°, 60°, and 90° in relation to the centerline of the device. Three planes with bidimensional velocity magnitude fields were considered in the analysis with visualization of diastolic jets, device wall washing patterns and flow circulation during emptying or systole of the pump. Also, the washing vortex area, and vertical velocity probabilities of regurgitant flows in the inlet valve were evaluated.Results: The results show that a variation in the angle of the MHV at the inlet port produced distinct velocities, fluid structures, and regurgitant flow probabilities within the device. MHV positioned at an angle of 0° generated the strongest inlet jet, larger vortex area during filling, more prominent outgoing flow, and less regurgitation compared to the angles studied. The presence of unfavorable fluid structures, such as small vortices, and/or sudden flow structure interruption, and/or regurgitation, were identified at 45° and 90° angles.Conclusions: The 0° inlet angle had better outcomes than other angles due to its consistency in the multiple parameters analyzed.
- 15 May 2022
- Published by Wiley in Artificial Organs
- Vol. 46 (9) , 1833-1846
Effect of the bileaflet inlet valve angle on the flow of a pediatric ventricular assist device: Experimental analysis
Background: Mechanical heart valves (MHV) and its fluid dynamics inside a pulsatile pediatric ventricular assist device (PVAD) can be associated with blood degradation. In this article, flow structures are analyzed and compared by an experimental investigation on the effect of bileaflet MHV positioned at varying angles in the inlet port orifice of a PVAD.Methods: Time‐resolved particle image velocimetry was applied to characterize the internal flow of the device. St Jude Medical bileaftlet valves were used on the inlet orifice and positioned at 0°, 15°, 30°, 45°, 60°, and 90° in relation to the centerline of the device. Three planes with bidimensional velocity magnitude fields were considered in the analysis with visualization of diastolic jets, device wall washing patterns and flow circulation during emptying or systole of the pump. Also, the washing vortex area, and vertical velocity probabilities of regurgitant flows in the inlet valve were evaluated.Results: The results show that a variation in the angle of the MHV at the inlet port produced distinct velocities, fluid structures, and regurgitant flow probabilities within the device. MHV positioned at an angle of 0° generated the strongest inlet jet, larger vortex area during filling, more prominent outgoing flow, and less regurgitation compared to the angles studied. The presence of unfavorable fluid structures, such as small vortices, and/or sudden flow structure interruption, and/or regurgitation, were identified at 45° and 90° angles.Conclusions: The 0° inlet angle had better outcomes than other angles due to its consistency in the multiple parameters analyzed.
- 2 December 2021
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 33 (2) , 025401
A novel method based on the Otsu threshold for instantaneous elimination of light reflection in PIV images
The base of particle image velocimetry (PIV) is the maximization of the correlation between the distribution of particle images in an interrogation window or a volume separated by an instant of time. In real images, the unwanted reflection of light on fixed walls or moving objects can directly interfere with the correlation, deteriorating the PIV quality. In this work, a new method for generating instantaneous masks based on the Otsu threshold for instantaneous elimination of light reflection in PIV images is proposed. This method separates the saturated image caused by the unwanted scattering of light from the tracer particles images through the Otsu threshold combined with the Gauss filter and Wiener adaptive local filter. This new method, called Otsu–Gauss–Wiener (OGW), was first tested using synthetic PIV images. In these tests, the authors analyzed the reflection caused by an object regarding different sizes, shapes, and intensities to evaluate the performance of the proposed method. Later, the OGW method was tested in PIV experimental cases with real adversities, for example, scattering of light on a fixed wall in a channel with periodic hills (case B—4th PIV challenge), strong reflection in a centrifugal impeller (case C—1st PIV challenge) and light scattering caused by an out-of-plane motion of the diaphragm of a pulsatile pediatric ventricular assist device. The results show that the method can remove the reflections by static and moving objects using an automatic mask generated for each instantaneous image.
- 2 December 2021
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 33 (2) , 025401
A novel method based on the Otsu threshold for instantaneous elimination of light reflection in PIV images
The base of particle image velocimetry (PIV) is the maximization of the correlation between the distribution of particle images in an interrogation window or a volume separated by an instant of time. In real images, the unwanted reflection of light on fixed walls or moving objects can directly interfere with the correlation, deteriorating the PIV quality. In this work, a new method for generating instantaneous masks based on the Otsu threshold for instantaneous elimination of light reflection in PIV images is proposed. This method separates the saturated image caused by the unwanted scattering of light from the tracer particles images through the Otsu threshold combined with the Gauss filter and Wiener adaptive local filter. This new method, called Otsu–Gauss–Wiener (OGW), was first tested using synthetic PIV images. In these tests, the authors analyzed the reflection caused by an object regarding different sizes, shapes, and intensities to evaluate the performance of the proposed method. Later, the OGW method was tested in PIV experimental cases with real adversities, for example, scattering of light on a fixed wall in a channel with periodic hills (case B—4th PIV challenge), strong reflection in a centrifugal impeller (case C—1st PIV challenge) and light scattering caused by an out-of-plane motion of the diaphragm of a pulsatile pediatric ventricular assist device. The results show that the method can remove the reflections by static and moving objects using an automatic mask generated for each instantaneous image.
- 11 October 2021
- Published by Springer Nature in Journal of the Brazilian Society of Mechanical Sciences and Engineering
- Vol. 43 (11) , 1-9
Thermodynamical model of an atmospheric steam engine
- 11 October 2021
- Published by Springer Nature in Journal of the Brazilian Society of Mechanical Sciences and Engineering
- Vol. 43 (11) , 1-9
Thermodynamical model of an atmospheric steam engine
- 1 March 2017
- Published by Elsevier in Chemical Engineering Science
- Vol. 160, 54-71
Using chaos analysis for evaluating the quality of F-PIV measurements in a bubble column
- 1 March 2017
- Published by Elsevier in Chemical Engineering Science
- Vol. 160, 54-71
Using chaos analysis for evaluating the quality of F-PIV measurements in a bubble column