HLHeng Li

Heng Li

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Heng Li has a total of 26 co-authors. Here are the top co-authors by number of shared publications:

  • Bin Yu

    Key Laboratory of Optoelectronic Devices and Systems of Ministry of Education and Guangdong Province, College of Physics and Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, China

    3 shared publications
  • Junle Qu

    Shenzhen University

    3 shared publications
  • Danni Chen

    Key Laboratory of Optoelectronic Devices and Systems of Ministry of Education College of Physics and Optoelectronic Engineering Shenzhen University Shenzhen 518060 Guangdong Province China

    2 shared publications
  • Danni Chen

    Peking University

    2 shared publications
  • Hanzhe Wu

    College of Physics and Optoelectronic Engineering, Key Laboratory of Optoelectronic Devices and Systems of Ministry of Education and Guangdong Province, Shenzhen University, Shenzhen 518060, P. R. China

    2 shared publications
  • Haoyuan Qiu

    College of Physics and Optoelectronic Engineering, Key Laboratory of Optoelectronic Devices and Systems of Ministry of Education and Guangdong Province, Shenzhen University, Shenzhen 518060, P. R. China

    2 shared publications

Latest Publications

  • Open Access

    Localizing axial dense emitters based on single‐helix point spread function and compressed sensing

    by Hanzhe Wu, Danni Chen, Yihong Ji, Gan Xiang, Yanxiang Ni, Heng Li, Bin Yu, Junle Qu

    Among the approaches in three‐dimensional (3D) single molecule localization microscopy, there are several point spread function (PSF) engineering approaches, in which depth information of molecules is encoded in 2D images. Usually, the molecules are excited sparsely in each raw image. The consequence is that the temporal resolution has to be sacrificed. In order to improve temporal resolution and ensure localization accuracy, we propose a method, SH‐CS, based on light needle excitation, detection system with single helix‐point spread function (SH‐PSF), and compressed sensing (CS). Although the SH‐CS method still has a limitation about the molecule density, it is suited for relatively dense molecules. For each light needle scanning position, an SH image of excited molecules is processed with CS algorithm to decode their axial information. Simulations demonstrated, for random distributed 1–15 molecules in depth range of 4 μm, the axial localization accuracy is 12.1–73.5 nm. The feasibility of this method is validated with a designed 3D sample composed of fluorescent beads.

  • Open Access

    SOFFLFM: Super-resolution optical fluctuation Fourier light-field microscopy

    by Haixin Huang, Haoyuan Qiu, Hanzhe Wu, Yihong Ji, Heng Li, Bin Yu, Danni Chen, Junle Qu

    Fourier light-field microscopy (FLFM) uses a microlens array (MLA) to segment the Fourier plane of the microscopic objective lens to generate multiple two-dimensional perspective views, thereby reconstructing the three-dimensional (3D) structure of the sample using 3D deconvolution calculation without scanning. However, the resolution of FLFM is still limited by diffraction, and furthermore, it is dependent on the aperture division. In order to improve its resolution, a super-resolution optical fluctuation Fourier light-field microscopy (SOFFLFM) was proposed here, in which the super-resolution optical fluctuation imaging (SOFI) with the ability of super-resolution was introduced into FLFM. SOFFLFM uses higher-order cumulants statistical analysis on an image sequence collected by FLFM, and then carries out 3D deconvolution calculation to reconstruct the 3D structure of the sample. The theoretical basis of SOFFLFM on improving resolution was explained and then verified with the simulations. Simulation results demonstrated that SOFFLFM improved the lateral and axial resolution by more than [ ] and 2 times in the second- and fourth-order accumulations, compared with that of FLFM.


  • Open Access

    SOFFLFM: Super-resolution optical fluctuation Fourier light-field microscopy

    by Haixin Huang, Haoyuan Qiu, Hanzhe Wu, Yihong Ji, Heng Li, Bin Yu, Danni Chen, Junle Qu

    Fourier light-field microscopy (FLFM) uses a micro-lens array (MLA) to segment the Fourier Plane of the microscopic objective lens to generate multiple two-dimensional perspective views, thereby reconstructing the three-dimensional(3D) structure of the sample using 3D deconvolution calculation without scanning. However, the resolution of FLFM is still limited by diffraction, and furthermore, dependent on the aperture division. In order to improve its resolution, a Super-resolution optical fluctuation Fourier light field microscopy (SOFFLFM) was proposed here, in which the Sofi method with ability of super-resolution was introduced into FLFM. SOFFLFM uses higher-order cumulants statistical analysis on an image sequence collected by FLFM, and then carries out 3D deconvolution calculation to reconstruct the 3D structure of the sample. Theoretical basis of SOFFLFM on improving resolution was explained and then verified with simulations. Simulation results demonstrated that SOFFLFM improved lateral and axial resolution by more than sqrt(2) and 2 times in the 2nd and 4th order accumulations, compared with that of FLFM.

  • Open Access

    Four‐dimensional multi‐particle tracking in living cells based on lifetime imaging

    by Danni Chen, Heng Li, Bin Yu, Junle Qu

    Research on dynamic events in living cells, such as intracellular transportation, is important for understanding cell functions. As movements occur within cells, the microenvironment of the moving vesicles or biomacromolecules may affect the behavior of them. Herein, we propose a method of simultaneously monitoring changes in spatial positions and the local environment related to the fluorescence lifetime, i.e., four‐dimensional (4D) multi‐particle parallel‐tracking in living cells. Based on double‐helix point spread function (DH‐PSF) microscopy and streak camera, the method combines three‐dimensional (3D) localization methods and fluorescence lifetime imaging. By modifying the PSF of the system, the 3D positions and fluorescence lifetime information for several molecules within a depth of a few microns can be acquired simultaneously from a single snapshot. The feasibility of this method is verified by simulating the real‐time tracking of a single particle with a given trajectory. In addition, a proof‐of‐concept 4D tracking system based on the DH‐PSF and streak camera was built. The experimental results show that the 3D localization and lifetime precision are σ ( x , y , z ) = (26 nm, 35 nm, 53 nm) and σ ( τ ) = 103 ps, respectively, and the effective depth of field is approximately 4 μm. Finally, intracellular endocytosis in a living cell was observed using the system, which demonstrated the successful 4D tracking of two microspheres moving within an axial depth of 4 μm. This work opens a new perspective for research of dynamic processes, by providing information about the chemical (microenvironments) and physical (positions) changes of moving targets in living cells.


  • Open Access

    Improved localization precision via restricting confined biomolecule stochastic motion in single‐molecule localization microscopy

    by Jielei Ni, Bo Cao, Gang Niu, Danni Chen, Guotao Liang, Tingying Xia, Heng Li, Chen Xu, Jingyu Wang, Wanlong Zhang, et al.

    Single‐molecule localization microscopy (SMLM) plays an irreplaceable role in biological studies, in which nanometer‐sized biomolecules are hardly to be resolved due to diffraction limit unless being stochastically activated and accurately located by SMLM. For biological samples preimmobilized for SMLM, most biomolecules are cross‐linked and constrained at their immobilizing sites but still expected to undergo confined stochastic motion in regard to their nanometer sizes. However, few lines of direct evidence have been reported about the detectability and influence of confined biomolecule stochastic motion on localization precision in SMLM. Here, we access the potential stochastic motion for each immobilized single biomolecule by calculating the displacements between any two of its localizations at different frames during sequential imaging of Alexa Fluor‐647‐conjugated oligonucleotides. For most molecules, localization displacements are remarkably larger at random frame intervals than at shortest intervals even after sample drift correction, increase with interval times and then saturate, showing that biomolecule stochastic motion is detected and confined around the immobilizing sizes in SMLM. Moreover, localization precision is inversely proportional to confined biomolecule stochastic motion, whereas it can be deteriorated or improved by enlarging the biomolecules or adding a post‐crosslinking step, respectively. Consistently, post‐crosslinking of cell samples sparsely stained for tubulin proteins results in a better localization precision. Overall, this study reveals that confined stochastic motion of immobilized biomolecules worsens localization precision in SMLM, and improved localization precision can be achieved via restricting such a motion.