Dayang Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Dayang Wang has a total of 69 co-authors. Here are the top co-authors by number of shared publications:
- Hengyong Yu
University of Massachusetts Lowell
12 shared publications - Li Zhou
University of Massachusetts Lowell
5 shared publications - Bahareh Morovati
University of Massachusetts Lowell
4 shared publications - Ge Wang
Rensselaer Polytechnic Institute
4 shared publications - Shuo Han
University of Massachusetts Lowell
4 shared publications - Boce Zhang
Department of Food Science and Human Nutrition, University of Florida, Gainesville, FL 32611, USA
3 shared publications
Latest Publications
- Open Access
- 17 August 2026
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 64  (6) , 1637-1651
DeepâLearning Based Contrast Boosting: A MultiâCenter MultiâReader Study on Clinical Performance With Standard Contrast Enhanced Brain MRI
Background: Gadoliniumâbased contrast agents are used in brain MRI to improve the visualization of disorders and improve the delineation of lesions. Higher doses of GBCAs can improve lesion sensitivity but may have safety implications, particularly in light of recent findings on gadolinium retention and deposition. Purpose: To evaluate the clinical performance of an FDAâcleared deepâlearning (DL)âbased contrast boosting algorithm in routine clinical brain MRI exams. Study Type: Retrospective. Population: One hundred ten patients (47 Âħ 22 years; 52 Females, 47 Males, 11 N/A) with clinical contrastâenhanced brain MR studies. Field Strength and Sequences: T1 weighted preâcontrast and postâcontrast brain MRI sequences at 0.3 T, 1.5 T, and 3 T. Assessment: A multiâcenter database of contrastâenhanced brain MR images was used to evaluate a DLâbased contrast boosting algorithm. Preâcontrast and standard postâcontrast (SC) images were processed with the algorithm to obtain contrast boosted (CB) images. CB images were compared to SC images in terms of contrastâtoânoise ratio (CNR), lesionâtoâbrain ratio (LBR), and contrast enhancement percentage (CEP). Three boardâcertified radiologists with 9, 15, and 18 years of experience reviewed CB and SC images sideâbyâside for qualitative evaluation and rated them on a 4âpoint Likert scale for lesion contrast enhancement, border delineation, internal morphology, overall image quality, presence of artifacts, and changes in vessel conspicuity. The presence, cause, and severity of any false lesions was recorded. Statistical Tests: Wilcoxon signed rank test. A p value < 0.05 was considered significant. Results: CB images had significantly superior quantitative performance than SC images in terms of CNR (729.17% Âħ 1576.92%), LBR (87.91% Âħ 72.12%), and CEP (165.81% Âħ 42%). In the qualitative assessment, CB images showed significantly better lesion visualization (3.73 vs. 3.16) and had significantly better image quality (3.55 vs. 3.07). Data Conclusion: In this multiâcenter, multiâreader study, deep learningâbased contrast boosting demonstrates robust improvements in lesion visualization and image quality without increasing contrast dosage. Evidence Level: 4. Technical Efficacy: Stage 3.
- 17 August 2026
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 64  (6) , 1637-1651
Open AccessDeepâLearning Based Contrast Boosting: A MultiâCenter MultiâReader Study on Clinical Performance With Standard Contrast Enhanced Brain MRI
Background: Gadoliniumâbased contrast agents are used in brain MRI to improve the visualization of disorders and improve the delineation of lesions. Higher doses of GBCAs can improve lesion sensitivity but may have safety implications, particularly in light of recent findings on gadolinium retention and deposition. Purpose: To evaluate the clinical performance of an FDAâcleared deepâlearning (DL)âbased contrast boosting algorithm in routine clinical brain MRI exams. Study Type: Retrospective. Population: One hundred ten patients (47 Âħ 22 years; 52 Females, 47 Males, 11 N/A) with clinical contrastâenhanced brain MR studies. Field Strength and Sequences: T1 weighted preâcontrast and postâcontrast brain MRI sequences at 0.3 T, 1.5 T, and 3 T. Assessment: A multiâcenter database of contrastâenhanced brain MR images was used to evaluate a DLâbased contrast boosting algorithm. Preâcontrast and standard postâcontrast (SC) images were processed with the algorithm to obtain contrast boosted (CB) images. CB images were compared to SC images in terms of contrastâtoânoise ratio (CNR), lesionâtoâbrain ratio (LBR), and contrast enhancement percentage (CEP). Three boardâcertified radiologists with 9, 15, and 18 years of experience reviewed CB and SC images sideâbyâside for qualitative evaluation and rated them on a 4âpoint Likert scale for lesion contrast enhancement, border delineation, internal morphology, overall image quality, presence of artifacts, and changes in vessel conspicuity. The presence, cause, and severity of any false lesions was recorded. Statistical Tests: Wilcoxon signed rank test. A p value < 0.05 was considered significant. Results: CB images had significantly superior quantitative performance than SC images in terms of CNR (729.17% Âħ 1576.92%), LBR (87.91% Âħ 72.12%), and CEP (165.81% Âħ 42%). In the qualitative assessment, CB images showed significantly better lesion visualization (3.73 vs. 3.16) and had significantly better image quality (3.55 vs. 3.07). Data Conclusion: In this multiâcenter, multiâreader study, deep learningâbased contrast boosting demonstrates robust improvements in lesion visualization and image quality without increasing contrast dosage. Evidence Level: 4. Technical Efficacy: Stage 3.
- 14 May 2026
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 123
Co-Retention feature pyramid network for low-dose CT denoising via spatial and frequency domain learning
- 14 May 2026
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 123
Co-Retention feature pyramid network for low-dose CT denoising via spatial and frequency domain learning
- 23 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. PP  (24697311) , 1
STABLE-PCCT: A Spectral Transformer Architecture with Bayesian Learning and Edge Preservation for Photon-Counting CT Image Reconstruction
Photon-counting computed tomography (PCCT) provides energy-resolved imaging with high spectral resolution, enabling advanced material decomposition and tissue characterization. However, photon starvation and spectral distortion, especially in low-dose settings, introduce severe noise and cross-channel artifacts, significantly degrading image quality. To address these challenges, we propose a Spectral Transformer Architecture with Bayesian Learning and Edge Preservation for PCCT (STABLE-PCCT). It is a novel deep learning framework that integrates depthwise separable convolutions (DSConv), squeeze-and-excitation (SE) blocks, and a residual Transformer module as a learned prior for Bayesian reconstruction. Each spectral channel is independently processed through lightweight convolutional encoders and SE modules to extract fine spatial features and enhance channel-specific saliency. The resulting feature representations are fused and refined using a Transformer block by modeling global intra-channel dependencies and contextual relationships. A fully connected layer path generates a high-fidelity spectral output. Additionally, anisotropic diffusion filtering (ADF) is applied in the image domain to suppress noise while preserving edges and texture details. Experimental results on simulated and real extremity MARS PCCT datasets demonstrate that STABLE-PCCT outperforms the state-of-the-art baselines in preserving anatomical structures, reducing noise, and improving spectral fidelity. The proposed framework offers an efficient and scalable solution for denoising and reconstruction in low-dose PCCT and other spectral imaging applications.
- 23 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. PP  (24697311) , 1
STABLE-PCCT: A Spectral Transformer Architecture with Bayesian Learning and Edge Preservation for Photon-Counting CT Image Reconstruction
Photon-counting computed tomography (PCCT) provides energy-resolved imaging with high spectral resolution, enabling advanced material decomposition and tissue characterization. However, photon starvation and spectral distortion, especially in low-dose settings, introduce severe noise and cross-channel artifacts, significantly degrading image quality. To address these challenges, we propose a Spectral Transformer Architecture with Bayesian Learning and Edge Preservation for PCCT (STABLE-PCCT). It is a novel deep learning framework that integrates depthwise separable convolutions (DSConv), squeeze-and-excitation (SE) blocks, and a residual Transformer module as a learned prior for Bayesian reconstruction. Each spectral channel is independently processed through lightweight convolutional encoders and SE modules to extract fine spatial features and enhance channel-specific saliency. The resulting feature representations are fused and refined using a Transformer block by modeling global intra-channel dependencies and contextual relationships. A fully connected layer path generates a high-fidelity spectral output. Additionally, anisotropic diffusion filtering (ADF) is applied in the image domain to suppress noise while preserving edges and texture details. Experimental results on simulated and real extremity MARS PCCT datasets demonstrate that STABLE-PCCT outperforms the state-of-the-art baselines in preserving anatomical structures, reducing noise, and improving spectral fidelity. The proposed framework offers an efficient and scalable solution for denoising and reconstruction in low-dose PCCT and other spectral imaging applications.
- 13 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Pattern Analysis and Machine Intelligence
- Vol. 48  (8) , 8813-8830
Hyper-Compression: Model Compression via Hyperfunction
The rapid growth of large models' size has far outpaced that of computing resources. To bridge this gap, encouraged by the parsimonious relationship between genotype and phenotype in the brain's growth and development, we propose the so-called hyper-compression that turns the model compression into the issue of parameter representation via a hyperfunction. Specifically, it is known that the trajectory of some low-dimensional dynamic systems can fill the high-dimensional space eventually. Thus, hyper-compression, using these dynamic systems as the hyperfunctions, represents the parameters of the target network by their corresponding composition number or trajectory length. This suggests a novel mechanism for model compression, substantially different from the existing pruning, quantization, distillation, and decomposition. Along this direction, we methodologically identify a suitable dynamic system with the irrational winding as the hyperfunction and theoretically derive its associated error bound. Next, guided by our theoretical insights, we propose several engineering twists to make the hyper-compression pragmatic and effective. Lastly, systematic and comprehensive experiments confirm that hyper-compression enjoys the following PNAS merits: 1) Preferable compression ratio; 2) No post-hoc retraining; 3) Affordable inference time; and 4) Short compression time. It compresses LLaMA2-7B in an hour and achieves close-to-int4-quantization performance, without retraining and with a performance drop of less than 1%. We have open-sourced our code in https://github.com/Juntongkuki/Hyper-Compression.git for free download and evaluation.
- 13 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Pattern Analysis and Machine Intelligence
- Vol. 48  (8) , 8813-8830
Hyper-Compression: Model Compression via Hyperfunction
The rapid growth of large models' size has far outpaced that of computing resources. To bridge this gap, encouraged by the parsimonious relationship between genotype and phenotype in the brain's growth and development, we propose the so-called hyper-compression that turns the model compression into the issue of parameter representation via a hyperfunction. Specifically, it is known that the trajectory of some low-dimensional dynamic systems can fill the high-dimensional space eventually. Thus, hyper-compression, using these dynamic systems as the hyperfunctions, represents the parameters of the target network by their corresponding composition number or trajectory length. This suggests a novel mechanism for model compression, substantially different from the existing pruning, quantization, distillation, and decomposition. Along this direction, we methodologically identify a suitable dynamic system with the irrational winding as the hyperfunction and theoretically derive its associated error bound. Next, guided by our theoretical insights, we propose several engineering twists to make the hyper-compression pragmatic and effective. Lastly, systematic and comprehensive experiments confirm that hyper-compression enjoys the following PNAS merits: 1) Preferable compression ratio; 2) No post-hoc retraining; 3) Affordable inference time; and 4) Short compression time. It compresses LLaMA2-7B in an hour and achieves close-to-int4-quantization performance, without retraining and with a performance drop of less than 1%. We have open-sourced our code in https://github.com/Juntongkuki/Hyper-Compression.git for free download and evaluation.
- 28 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 45  (5) , 1776-1786
UPMCL-Net: Unsupervised Projection-Domain Multiview Constraint Learning for CBCT Metal Artifact Reduction
Cone-Beam Computed Tomography (CBCT) provides real-time three-dimensional (3D) imaging support for intraoperative navigation. However, high-attenuation metal implants introduce severe metal artifacts in reconstructed CBCT images. These artifacts compromise image quality and therefore may affect diagnostic accuracy. Current CBCT metal artifact reduction (MAR) algorithms overlook the complementary information available across CBCT views, leading to inaccurate projection-domain interpolation and secondary artifacts in the reconstructed images. To tackle these challenges, we propose a novel Unsupervised Projection-domain Multiview Constraint Learning Network (UPMCL-Net), which directly learns from metal-affected data for CBCT MAR without ground truths. In addition, a transformer-based MultiView Consistency Module (MVCM) is constructed to interpolate the projection-domain metal region for cross-view consistency. Finally, a Hybrid Feature Attention Module (HFAM) is designed to adaptively fuse interview and intraview features. Comprehensive experiments conducted on real clinical datasets confirm the performance of UPMCL-Net, showcasing its potential as an efficient, accurate, and reliable approach for CBCT MAR in clinical intraoperative interventions.
- 28 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 45  (5) , 1776-1786
UPMCL-Net: Unsupervised Projection-Domain Multiview Constraint Learning for CBCT Metal Artifact Reduction
Cone-Beam Computed Tomography (CBCT) provides real-time three-dimensional (3D) imaging support for intraoperative navigation. However, high-attenuation metal implants introduce severe metal artifacts in reconstructed CBCT images. These artifacts compromise image quality and therefore may affect diagnostic accuracy. Current CBCT metal artifact reduction (MAR) algorithms overlook the complementary information available across CBCT views, leading to inaccurate projection-domain interpolation and secondary artifacts in the reconstructed images. To tackle these challenges, we propose a novel Unsupervised Projection-domain Multiview Constraint Learning Network (UPMCL-Net), which directly learns from metal-affected data for CBCT MAR without ground truths. In addition, a transformer-based MultiView Consistency Module (MVCM) is constructed to interpolate the projection-domain metal region for cross-view consistency. Finally, a Hybrid Feature Attention Module (HFAM) is designed to adaptively fuse interview and intraview features. Comprehensive experiments conducted on real clinical datasets confirm the performance of UPMCL-Net, showcasing its potential as an efficient, accurate, and reliable approach for CBCT MAR in clinical intraoperative interventions.
- Open Access
- 6 February 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70  (4) , 045008
Patch-based dual-domain photon-counting CT data correction with residual-based WGAN-ViT
Objective. x-ray photon-counting detectors have recently gained popularity due to their capabilities in energy discrimination power, noise suppression, and resolution refinement. The latest extremity photon-counting computed tomography (PCCT) scanner leverages these advantages for tissue characterization, material decomposition, beam hardening correction, and metal artifact reduction. However, technical challenges such as charge splitting and pulse pileup can distort the energy spectrum and compromise image quality. Also, there is a clinical need to balance radiation dose and imaging speed for contrast-enhancement and other studies. This paper aims to address these challenges by developing a dual-domain correction approach to enhance PCCT reconstruction quality quantitatively and qualitatively. Approach. We propose a novel correction method that operates in both projection and image domains. In the projection domain, we employ a residual-based Wasserstein generative adversarial network to capture local and global features, suppressing pulse pileup, charge splitting, and data noise. This is facilitated with traditional filtering methods in the image domain to enhance signal-to-noise ratio while preserving texture across each energy channel. To address GPU memory constraints, our approach utilizes a patch-based volumetric refinement network. Main results. Our dual-domain correction approach demonstrates significant fidelity improvements across both projection and image domains. Experiments on simulated and real datasets reveal that the proposed model effectively suppresses noise and preserves intricate details, outperforming the state-of-the-art methods. Significance. This approach highlights the potential of dual-domain PCCT data correction to enhance image quality for clinical applications, showing promise for advancing PCCT image fidelity and applicability in preclinical/clinical environments.
- 6 February 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70  (4) , 045008
Open AccessPatch-based dual-domain photon-counting CT data correction with residual-based WGAN-ViT
Objective. x-ray photon-counting detectors have recently gained popularity due to their capabilities in energy discrimination power, noise suppression, and resolution refinement. The latest extremity photon-counting computed tomography (PCCT) scanner leverages these advantages for tissue characterization, material decomposition, beam hardening correction, and metal artifact reduction. However, technical challenges such as charge splitting and pulse pileup can distort the energy spectrum and compromise image quality. Also, there is a clinical need to balance radiation dose and imaging speed for contrast-enhancement and other studies. This paper aims to address these challenges by developing a dual-domain correction approach to enhance PCCT reconstruction quality quantitatively and qualitatively. Approach. We propose a novel correction method that operates in both projection and image domains. In the projection domain, we employ a residual-based Wasserstein generative adversarial network to capture local and global features, suppressing pulse pileup, charge splitting, and data noise. This is facilitated with traditional filtering methods in the image domain to enhance signal-to-noise ratio while preserving texture across each energy channel. To address GPU memory constraints, our approach utilizes a patch-based volumetric refinement network. Main results. Our dual-domain correction approach demonstrates significant fidelity improvements across both projection and image domains. Experiments on simulated and real datasets reveal that the proposed model effectively suppresses noise and preserves intricate details, outperforming the state-of-the-art methods. Significance. This approach highlights the potential of dual-domain PCCT data correction to enhance image quality for clinical applications, showing promise for advancing PCCT image fidelity and applicability in preclinical/clinical environments.
- 13 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Networks and Learning Systems
- Vol. 36  (7) , 12311-12325
Manifoldron: Direct Space Partition via Manifold Discovery
A neural network (NN) with the widely-used ReLU activation has been shown to partition the sample space into many convex polytopes for prediction. However, the parametric way a NN and other machine learning models use to partition the space has imperfections, e.g., the compromised interpretability for complex models, the inflexibility in decision boundary construction due to the generic character of the model, and the risk of being trapped into shortcut solutions. In contrast, although the nonparameterized models can adorably avoid or downplay these issues, they are usually insufficiently powerful either due to over-simplification or the failure to accommodate the manifold structures of data. In this context, we first propose a new type of machine learning models referred to as Manifoldron that directly derives decision boundaries from data and partitions the space via manifold structure discovery. Then, we systematically analyze the key characteristics of the Manifoldron such as manifold characterization capability and its link to NNs. The experimental results on four synthetic examples, 20 public benchmark datasets, and one real-world application demonstrate that the proposed Manifoldron performs competitively compared to the mainstream machine learning models. We have shared our code in https://github.com/wdayang/Manifoldron for free download and evaluation.
- 13 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Networks and Learning Systems
- Vol. 36  (7) , 12311-12325
Manifoldron: Direct Space Partition via Manifold Discovery
A neural network (NN) with the widely-used ReLU activation has been shown to partition the sample space into many convex polytopes for prediction. However, the parametric way a NN and other machine learning models use to partition the space has imperfections, e.g., the compromised interpretability for complex models, the inflexibility in decision boundary construction due to the generic character of the model, and the risk of being trapped into shortcut solutions. In contrast, although the nonparameterized models can adorably avoid or downplay these issues, they are usually insufficiently powerful either due to over-simplification or the failure to accommodate the manifold structures of data. In this context, we first propose a new type of machine learning models referred to as Manifoldron that directly derives decision boundaries from data and partitions the space via manifold structure discovery. Then, we systematically analyze the key characteristics of the Manifoldron such as manifold characterization capability and its link to NNs. The experimental results on four synthetic examples, 20 public benchmark datasets, and one real-world application demonstrate that the proposed Manifoldron performs competitively compared to the mainstream machine learning models. We have shared our code in https://github.com/wdayang/Manifoldron for free download and evaluation.
- 8 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. PP  (02780062) , 1
Physics-informed Score-based Diffusion Model for Limited-angle Reconstruction of Cardiac Computed Tomography
Cardiac computed tomography (CT) has emerged as a major imaging modality for the diagnosis and monitoring of cardiovascular diseases. High temporal resolution is essential to ensure diagnostic accuracy. Limited-angle data acquisition can reduce scan time and improve temporal resolution, but typically leads to severe image degradation and motivates for improved reconstruction techniques. In this paper, we propose a novel physics-informed score-based diffusion model (PSDM) for limited-angle reconstruction of cardiac CT. At the sampling time, we combine a data prior from a diffusion model and a model prior obtained via an iterative algorithm and Fourier fusion to further enhance the image quality. Specifically, our approach integrates the primal-dual hybrid gradient (PDHG) algorithm with score-based diffusion models, thereby enabling us to reconstruct high-quality cardiac CT images from limited-angle data. The numerical simulations and real data experiments confirm the effectiveness of our proposed approach.
- 8 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. PP  (02780062) , 1
Physics-informed Score-based Diffusion Model for Limited-angle Reconstruction of Cardiac Computed Tomography
Cardiac computed tomography (CT) has emerged as a major imaging modality for the diagnosis and monitoring of cardiovascular diseases. High temporal resolution is essential to ensure diagnostic accuracy. Limited-angle data acquisition can reduce scan time and improve temporal resolution, but typically leads to severe image degradation and motivates for improved reconstruction techniques. In this paper, we propose a novel physics-informed score-based diffusion model (PSDM) for limited-angle reconstruction of cardiac CT. At the sampling time, we combine a data prior from a diffusion model and a model prior obtained via an iterative algorithm and Fourier fusion to further enhance the image quality. Specifically, our approach integrates the primal-dual hybrid gradient (PDHG) algorithm with score-based diffusion models, thereby enabling us to reconstruct high-quality cardiac CT images from limited-angle data. The numerical simulations and real data experiments confirm the effectiveness of our proposed approach.
- 5 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 28  (11) , 6815-6827
LoMAE: Simple Streamlined Low-Level Masked Autoencoders for Robust, Generalized, and Interpretable Low-Dose CT Denoising
Low-dose computed tomography (LDCT) offers reduced X-ray radiation exposure but at the cost of compromised image quality, characterized by increased noise and artifacts. Recently, transformer models emerged as a promising avenue to enhance LDCT image quality. However, the success of such models relies on a large amount of paired noisy and clean images, which are often scarce in clinical settings. In computer vision and natural language processing, masked autoencoders (MAE) have been recognized as a powerful self-pretraining method for transformers, due to their exceptional capability to extract representative features. However, the original pretraining and fine-tuning design fails to work in low-level vision tasks like denoising. In response to this challenge, we redesign the classical encoder-decoder learning model and facilitate a simple yet effective streamlined low-level vision MAE, referred to as LoMAE, tailored to address the LDCT denoising problem. Moreover, we introduce an MAE-GradCAM method to shed light on the latent learning mechanisms of the MAE/LoMAE. Additionally, we explore the LoMAE's robustness and generability across a variety of noise levels. Experimental findings show that the proposed LoMAE enhances the denoising capabilities of the transformer and substantially reduce their dependency on high-quality, ground-truth data. It also demonstrates remarkable robustness and generalizability over a spectrum of noise levels. In summary, the proposed LoMAE provides promising solutions to the major issues in LDCT including interpretability, ground truth data dependency, and model robustness/generalizability.
- 5 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 28  (11) , 6815-6827
LoMAE: Simple Streamlined Low-Level Masked Autoencoders for Robust, Generalized, and Interpretable Low-Dose CT Denoising
Low-dose computed tomography (LDCT) offers reduced X-ray radiation exposure but at the cost of compromised image quality, characterized by increased noise and artifacts. Recently, transformer models emerged as a promising avenue to enhance LDCT image quality. However, the success of such models relies on a large amount of paired noisy and clean images, which are often scarce in clinical settings. In computer vision and natural language processing, masked autoencoders (MAE) have been recognized as a powerful self-pretraining method for transformers, due to their exceptional capability to extract representative features. However, the original pretraining and fine-tuning design fails to work in low-level vision tasks like denoising. In response to this challenge, we redesign the classical encoder-decoder learning model and facilitate a simple yet effective streamlined low-level vision MAE, referred to as LoMAE, tailored to address the LDCT denoising problem. Moreover, we introduce an MAE-GradCAM method to shed light on the latent learning mechanisms of the MAE/LoMAE. Additionally, we explore the LoMAE's robustness and generability across a variety of noise levels. Experimental findings show that the proposed LoMAE enhances the denoising capabilities of the transformer and substantially reduce their dependency on high-quality, ground-truth data. It also demonstrates remarkable robustness and generalizability over a spectrum of noise levels. In summary, the proposed LoMAE provides promising solutions to the major issues in LDCT including interpretability, ground truth data dependency, and model robustness/generalizability.
- 2 January 2024
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 248, 115999
Surveillance of pathogenic bacteria on a food matrix using machine-learning-enabled paper chromogenic arrays
- 2 January 2024
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 248, 115999
Surveillance of pathogenic bacteria on a food matrix using machine-learning-enabled paper chromogenic arrays