Hüseyin Tayyer Canseven
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Hüseyin Tayyer Canseven has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Juha Pyrhonen
LUT University
7 shared publications - Ilya Petrov
LUT University
5 shared publications - Ali Bakbak
Department of Electrical and Electronics Engineering, Manisa Celal Bayar University, Manisa 45140, Türkiye
3 shared publications - Erkan Meşe
Department of Electrical-Electronic Engineering, Ege University, İzmir 35030, Türkiye
3 shared publications - Mert Altintas
Department of Electrical and Electronics Engineering, Ege University, İzmir, Turkey
3 shared publications - Murat Ayaz
Department of Electric and Energy, Kocaeli University, Kocaeli 41180, Türkiye
3 shared publications
Latest Publications
- Open Access
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 62 (10) , 8205410
Comparative Analysis of Three-Phase Short-Circuit Dynamic Behavior in Interior and Surface Magnet PMSMs
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 62 (10) , 8205410
Open AccessComparative Analysis of Three-Phase Short-Circuit Dynamic Behavior in Interior and Surface Magnet PMSMs
- 23 June 2026
- Published by Springer Nature
- p. 836-850
Transient Torsional Rotordynamic Analysis in the Case of Short Circuit in Permanent Magnet Synchronous Machines
- 23 June 2026
- Published by Springer Nature
- p. 836-850
Transient Torsional Rotordynamic Analysis in the Case of Short Circuit in Permanent Magnet Synchronous Machines
- Open Access
Advanced Fault Detection of Permanent Magnet Faults in Offshore Wind Turbine Generators Using Finite Element Analysis and Deep Transfer Learning
As the offshore wind industry scales toward 15 MW capacity, the reliability of Direct-Drive Permanent Magnet Synchronous Generators (DD-PMSGs) becomes critical. However, real-world run-to-failure data for these massive, multi-pole machines is virtually non-existent, creating a barrier for developing effective data-driven diagnostic systems. This study proposes a high-fidelity framework for detecting permanent magnet faults in the International Energy Agency (IEA) 15 MW Reference Wind Turbine. Using Finite Element Analysis (FEA), a dataset (magnetic flux and back electromotive-force (EMF)) capturing the electromagnetic signatures of healthy and faulty states of a PMSG under varying severities is generated. To improve the power of computer vision, 1D time-series signals were transformed into 2D images. Specifically, Gramian Angular Fields (GAFs) and Recurrence Plots (RPs) were applied to magnetic flux density signals, while Markov Transition Fields (MTFs) were applied to back-EMF signals. These representations were then fused into multi-channel Red-Green-Blue (RGB) images and processed via a ResNet-18 Deep Transfer Learning model using a strictly non-overlapping, leakage-free dataset partitioning strategy. The proposed framework achieved a classification accuracy of 99.45% on noise-free data. Furthermore, robustness testing under varying levels of Additive White Gaussian Noise (AWGN) (30 dB, 40 dB, and 50 dB Signal-to-Noise Ratio (SNR)) demonstrated sustained high performance, maintaining over 90% accuracy even under severe 30 dB noise conditions. Comparative analysis proved that this multi-channel fusion significantly outperforms single-channel encoding methods, which collapse under heavy noise, validating the scalability of the framework and applicability for next-generation condition monitoring in harsh offshore environments.
Open AccessAdvanced Fault Detection of Permanent Magnet Faults in Offshore Wind Turbine Generators Using Finite Element Analysis and Deep Transfer Learning
As the offshore wind industry scales toward 15 MW capacity, the reliability of Direct-Drive Permanent Magnet Synchronous Generators (DD-PMSGs) becomes critical. However, real-world run-to-failure data for these massive, multi-pole machines is virtually non-existent, creating a barrier for developing effective data-driven diagnostic systems. This study proposes a high-fidelity framework for detecting permanent magnet faults in the International Energy Agency (IEA) 15 MW Reference Wind Turbine. Using Finite Element Analysis (FEA), a dataset (magnetic flux and back electromotive-force (EMF)) capturing the electromagnetic signatures of healthy and faulty states of a PMSG under varying severities is generated. To improve the power of computer vision, 1D time-series signals were transformed into 2D images. Specifically, Gramian Angular Fields (GAFs) and Recurrence Plots (RPs) were applied to magnetic flux density signals, while Markov Transition Fields (MTFs) were applied to back-EMF signals. These representations were then fused into multi-channel Red-Green-Blue (RGB) images and processed via a ResNet-18 Deep Transfer Learning model using a strictly non-overlapping, leakage-free dataset partitioning strategy. The proposed framework achieved a classification accuracy of 99.45% on noise-free data. Furthermore, robustness testing under varying levels of Additive White Gaussian Noise (AWGN) (30 dB, 40 dB, and 50 dB Signal-to-Noise Ratio (SNR)) demonstrated sustained high performance, maintaining over 90% accuracy even under severe 30 dB noise conditions. Comparative analysis proved that this multi-channel fusion significantly outperforms single-channel encoding methods, which collapse under heavy noise, validating the scalability of the framework and applicability for next-generation condition monitoring in harsh offshore environments.
- 31 May 2026
- Published by Bilecik Seyh Edebali Universitesi Fen Bilimleri Dergisi in Bilecik Şeyh Edebali Üniversitesi Fen Bilimleri Dergisi
- Vol. 13 (1) , 384-400
Sabit Mıknatıslı Senkron Makinelerde Demanyetizasyon: Modelleme, Teşhis ve Gelecek Yönelimler
Elektrikli araç ve yenilenebilir enerji sistemlerinde Sabit Mıknatıslı Senkron Makineler (SMSM), yüksek tork yoğunluğu ve üstün verimlilikleri nedeniyle yaygın olarak kullanılmaktadır. Bu makinelerde meydana gelen arızalar, özellikle elektrikli araç tahrik sistemlerinde ve rüzgâr türbinlerinde performans kaybı, güvenirlik sorunları ve ek bakım maliyetlerine yol açmaktadır. Sürekli değişen yük, hız ve sıcaklık koşulları altında SMSM’lerin arıza eğilimi artmakta olup demanyetizasyon, rotor mıknatıslarının kalıcı manyetik özelliklerini kaybetmesi nedeniyle en kritik arızalardan biri olarak kabul edilmektedir. Demanyetizasyon, manyetik çevrimin kararlılığını bozarak akı dağılımının değişmesine, moment dalgalanmalarının artmasına, harmonik bozulmalara ve ısıl kararsızlığa neden olur. Düzensiz demanyetizasyon ise rotor çevresinde asimetri oluşturarak titreşim ve akustik gürültüyü yükseltir. Bu çalışmada demanyetizasyon arızaları bütüncül olarak ele alınmış; manyetik bozulma mekanizmaları ile teşhis göstergeleri arasındaki ilişki detaylandırılmıştır. Mıknatıs malzemesi özellikleri, knee bölgesi davranışı ve termal–manyetik etkileşimler değerlendirilmiş; B–H eğrisine dayalı analitik modellere ek olarak farklı arıza seviyelerinin manyetik tepkileri Sonlu Elemanlar Analizi (SEA) ile incelenmiştir. SEA sonuçları üzerinden akı zayıflaması, tork üretimi, zıt elektromotor kuvvet ve alan yoğunluğu değişimleri nicel olarak karşılaştırılmıştır. Ayrıca sinyal işleme, gözlemci tabanlı ve makine öğrenmesi destekli teşhis yöntemleri performans, gürültü dayanımı, sensör gereksinimi ve gerçek zamanlı uygulanabilirlik açısından karşılaştırılmıştır. Bu çalışma, elektrikli araç ve rüzgâr enerjisi uygulamaları için kapsamlı bir referans çerçeve sunmakta ve hibrit teşhis yaklaşımlarının gelecekteki araştırmalar için sunduğu potansiyeli tartışmaktadır.
- 31 May 2026
- Published by Bilecik Seyh Edebali Universitesi Fen Bilimleri Dergisi in Bilecik Şeyh Edebali Üniversitesi Fen Bilimleri Dergisi
- Vol. 13 (1) , 384-400
Sabit Mıknatıslı Senkron Makinelerde Demanyetizasyon: Modelleme, Teşhis ve Gelecek Yönelimler
Elektrikli araç ve yenilenebilir enerji sistemlerinde Sabit Mıknatıslı Senkron Makineler (SMSM), yüksek tork yoğunluğu ve üstün verimlilikleri nedeniyle yaygın olarak kullanılmaktadır. Bu makinelerde meydana gelen arızalar, özellikle elektrikli araç tahrik sistemlerinde ve rüzgâr türbinlerinde performans kaybı, güvenirlik sorunları ve ek bakım maliyetlerine yol açmaktadır. Sürekli değişen yük, hız ve sıcaklık koşulları altında SMSM’lerin arıza eğilimi artmakta olup demanyetizasyon, rotor mıknatıslarının kalıcı manyetik özelliklerini kaybetmesi nedeniyle en kritik arızalardan biri olarak kabul edilmektedir. Demanyetizasyon, manyetik çevrimin kararlılığını bozarak akı dağılımının değişmesine, moment dalgalanmalarının artmasına, harmonik bozulmalara ve ısıl kararsızlığa neden olur. Düzensiz demanyetizasyon ise rotor çevresinde asimetri oluşturarak titreşim ve akustik gürültüyü yükseltir. Bu çalışmada demanyetizasyon arızaları bütüncül olarak ele alınmış; manyetik bozulma mekanizmaları ile teşhis göstergeleri arasındaki ilişki detaylandırılmıştır. Mıknatıs malzemesi özellikleri, knee bölgesi davranışı ve termal–manyetik etkileşimler değerlendirilmiş; B–H eğrisine dayalı analitik modellere ek olarak farklı arıza seviyelerinin manyetik tepkileri Sonlu Elemanlar Analizi (SEA) ile incelenmiştir. SEA sonuçları üzerinden akı zayıflaması, tork üretimi, zıt elektromotor kuvvet ve alan yoğunluğu değişimleri nicel olarak karşılaştırılmıştır. Ayrıca sinyal işleme, gözlemci tabanlı ve makine öğrenmesi destekli teşhis yöntemleri performans, gürültü dayanımı, sensör gereksinimi ve gerçek zamanlı uygulanabilirlik açısından karşılaştırılmıştır. Bu çalışma, elektrikli araç ve rüzgâr enerjisi uygulamaları için kapsamlı bir referans çerçeve sunmakta ve hibrit teşhis yaklaşımlarının gelecekteki araştırmalar için sunduğu potansiyeli tartışmaktadır.
- Open Access
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 165110-165130
Beyond Closed-Set Accuracy: Constituent-Level Generalization in Induction Motor Fault Diagnosis
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 165110-165130
Open AccessBeyond Closed-Set Accuracy: Constituent-Level Generalization in Induction Motor Fault Diagnosis
- Open Access
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 115596-115608
Onset-Aware Alarm-Triggered Fault Diagnosis in Collaborative Robots
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 115596-115608
Open AccessOnset-Aware Alarm-Triggered Fault Diagnosis in Collaborative Robots
- Open Access
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 92580-92594
System-Level Switching-Frequency Trade-Offs in a High-Fundamental-Frequency MW-Class PMSM Drive
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 92580-92594
Open AccessSystem-Level Switching-Frequency Trade-Offs in a High-Fundamental-Frequency MW-Class PMSM Drive
- Top Cited PapersOpen Access
- 1 January 2026
- Published by Institution of Engineering and Technology (IET) in IET Power Electronics
- Vol. 19 (1)
Fault Detection and Diagnosis for Multi‐Faults of PMSM‐Drive Systems Using a Hybrid Machine Learning Method
This paper presents a non‐invasive fault detection and diagnosis (FDD) methodology for permanent magnet synchronous machine (PMSM) drives, using low‐frequency phase current signals. Specifically, this work focuses on the detection and diagnosis of power electronics‐related inverter faults, which are a common source of system failures. The proposed framework introduces a pairwise feature fusion technique to enhance class separability and employs a three‐stage selection process to distil a compact, discriminative feature set from Clarke‐transformed current data. Diagnosis is performed by a hybrid machine learning model that ensembles the predictions of random forest, histogram‐based gradient boosting, and k‐nearest neighbours classifiers via a late‐fusion strategy. The performance of the proposed method is evaluated on a publicly available experimental dataset containing nine operational states (one healthy and eight distinct inverter faults). The proposed method achieves an overall accuracy of 93.3% and a macro F1‐score of 95.91%. The results demonstrate that the proposed approach can accurately diagnose multiple inverter faults without requiring high‐frequency data acquisition or additional sensors, offering a cost‐effective solution for enhancing the reliability of PMSM drives.
- 1 January 2026
- Published by Institution of Engineering and Technology (IET) in IET Power Electronics
- Vol. 19 (1)
Top Cited PapersOpen AccessFault Detection and Diagnosis for Multi‐Faults of PMSM‐Drive Systems Using a Hybrid Machine Learning Method
This paper presents a non‐invasive fault detection and diagnosis (FDD) methodology for permanent magnet synchronous machine (PMSM) drives, using low‐frequency phase current signals. Specifically, this work focuses on the detection and diagnosis of power electronics‐related inverter faults, which are a common source of system failures. The proposed framework introduces a pairwise feature fusion technique to enhance class separability and employs a three‐stage selection process to distil a compact, discriminative feature set from Clarke‐transformed current data. Diagnosis is performed by a hybrid machine learning model that ensembles the predictions of random forest, histogram‐based gradient boosting, and k‐nearest neighbours classifiers via a late‐fusion strategy. The performance of the proposed method is evaluated on a publicly available experimental dataset containing nine operational states (one healthy and eight distinct inverter faults). The proposed method achieves an overall accuracy of 93.3% and a macro F1‐score of 95.91%. The results demonstrate that the proposed approach can accurately diagnose multiple inverter faults without requiring high‐frequency data acquisition or additional sensors, offering a cost‐effective solution for enhancing the reliability of PMSM drives.
- Open Access
- 25 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 201711-201725
Advanced Direct Cooling Arrangements for Machines With Hairpin Windings
Advanced thermal management is crucial for high-power-density electric machines with hairpin windings to ensure reliability and performance. This paper presents a comparative thermal analysis of an embedded permanent magnet synchronous machine, evaluating two in-slot cooling arrangements: slot oil cooling (SOC) and direct oil cooling (DOC). While these advanced in-slot cooling methods are employed to manage the thermal challenges, a critical gap exists in the literature regarding a direct, quantitative comparison of their practical limits, particularly under transient overload conditions. This paper directly addresses this critical gap to provide a definitive answer. The primary contribution of this work is to provide a significant and quantitative comparison that moves beyond simple steady-state analysis to reveal under realistic operating conditions. The analysis utilizes 2D Finite Element Method (FEM) simulations, with heat sources derived from electromagnetic calculations and convective boundary conditions established through analytical modeling, which were anchored by experimental validation to ensure high accuracy. A steady-state analysis across multiple operating points reveals that while DOC consistently reduces peak winding temperature by 15 °C, its necessity becomes critical at high speeds; the SOC system exceeds the thermal limit of the winding insulation class at the maximum speed condition. In contrast, the DOC system maintains temperatures safely within this limit across the entire operational range. Alternatively, the DOC enables a 20% increase in torque output for the same thermal limit. Additionally, a transient overload analysis demonstrates the robustness of DOC safely managing thermal stress, while the SOC arrangement exceeds the thermal limits, posing an unacceptable risk to motor longevity. This study concludes that DOC is not a performance enhancement but a critical and enabling technology for ensuring the operational reliability and achieve the full potential of hairpin winding machines in demanding applications.
- 25 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 201711-201725
Open AccessAdvanced Direct Cooling Arrangements for Machines With Hairpin Windings
Advanced thermal management is crucial for high-power-density electric machines with hairpin windings to ensure reliability and performance. This paper presents a comparative thermal analysis of an embedded permanent magnet synchronous machine, evaluating two in-slot cooling arrangements: slot oil cooling (SOC) and direct oil cooling (DOC). While these advanced in-slot cooling methods are employed to manage the thermal challenges, a critical gap exists in the literature regarding a direct, quantitative comparison of their practical limits, particularly under transient overload conditions. This paper directly addresses this critical gap to provide a definitive answer. The primary contribution of this work is to provide a significant and quantitative comparison that moves beyond simple steady-state analysis to reveal under realistic operating conditions. The analysis utilizes 2D Finite Element Method (FEM) simulations, with heat sources derived from electromagnetic calculations and convective boundary conditions established through analytical modeling, which were anchored by experimental validation to ensure high accuracy. A steady-state analysis across multiple operating points reveals that while DOC consistently reduces peak winding temperature by 15 °C, its necessity becomes critical at high speeds; the SOC system exceeds the thermal limit of the winding insulation class at the maximum speed condition. In contrast, the DOC system maintains temperatures safely within this limit across the entire operational range. Alternatively, the DOC enables a 20% increase in torque output for the same thermal limit. Additionally, a transient overload analysis demonstrates the robustness of DOC safely managing thermal stress, while the SOC arrangement exceeds the thermal limits, posing an unacceptable risk to motor longevity. This study concludes that DOC is not a performance enhancement but a critical and enabling technology for ensuring the operational reliability and achieve the full potential of hairpin winding machines in demanding applications.
- Open Access
- 19 April 2025
- Published by Elsevier in Applied Thermal Engineering
- Vol. 273
Direct liquid cooling in compact machines: Advantages and limitations
- 19 April 2025
- Published by Elsevier in Applied Thermal Engineering
- Vol. 273
Open AccessDirect liquid cooling in compact machines: Advantages and limitations