JLJianzhe Liu

Jianzhe Liu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jianzhe Liu has a total of 114 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Robust Region of Attraction for DC Microgrids Under Uncertain Loading Conditions

    by Jianzhe Liu, Minchang Zhang, Canbing Li, Sui Peng, Yanfeng Wang, Guo Chen, Xinxi Li

    A guaranteed region of attraction (ROA) is essential for ensuring transient stability in DC microgrids. Numerical methods and control strategies for ROA design often rely on parameter tuning tailored to a specific operating scenario. When the steady-state load varies, both the operating point and the associated ROA change, causing fixed-scenario guarantees to break down and offering limited robustness. This letter develops a robust control synthesis method that ensures transient stability with guaranteed ROA. First, a robust stability condition is proposed to ensure a guaranteed ROA that adaptively moves with the operating point; then, we incorporate the condition into an optimal power flow (OPF)-like control synthesis problem that jointly ensures operational feasibility and robust stability guarantees while preserving computational efficiency. Simulation case studies validate the effectiveness of the proposed method.

  • Optimal Polygon-Closure Mechanism: A Cost-Minimized Solution for Filtering Multiple Harmonic Sources in Energy Routers

    by Ruiheng Guo, Wentao Huang, Jianzhe Liu, Moduo Yu, Yuyang Zhang

    Energy routers (ERs) are an efficient technology for deploying renewable microgrids, especially in isolated regions. Secondary harmonic currents (SHCs) from unbalanced inverters cause low-frequency oscillations in the operating points of sources and loads, reducing their performance and lifespan. Existing filtering solutions require manufacturers to deploy large-capacity active power filters (APFs) in multiple SHC scenarios, incurring unacceptably high expenses. This paper introduces an optimal polygon-closure mechanism that intrinsically links SHC filtering to polygon shape optimization. Within this framework, optimal filtering—minimizing the SHC absorption by APF while preserving AC-side power quality and completely filtering SHCs—corresponds to forming a closed polygon with the minimal perimeter. First, a polygon shaping strategy is proposed to minimize the polygon perimeter by adjusting SHC phases. This effectively reduces the SHC required to be absorbed by APF to zero or below the largest single SHC, enabling the elimination of multiple SHCs using a low-capacity filter. Second, a polygon closure strategy is designed to ensure polygon closure by using APFs to absorb the SHC. This method enables accurate and complete SHC filtering and provides the essential functions of harmonic sharing, plug-and-play operation, and applicability to both step-up and step-down APFs. The solution enables the APF capacity to be determined by the maximum SHC among all individual branches rather than the aggregate of the maximum SHCs from all branches, substantially cutting APF installation costs. Simulation results in RT-LAB confirm that the proposed method significantly reduces the APF filtering burden, achieves complete SHC elimination, does not impair transient control, and reduces APF capacity by 54.55% in a real-world project involving three harmonic sources.

  • Network-Informed Numerical Characterization of DC Network Static Voltage Stability Region

    by Minchang Zhang, Jianzhe Liu, Canbing Li, Jun Yan, Yu Zhang, Haojing Wang

    A static voltage stability region (SVSR) of a DC network is a set of load power injection profiles modeled as power flow parameters. Any realization within the set ensures power flow equation solvability, i.e. the existence of an operating point. Accurately characterizing the SVSR is crucial for understanding DC network stability. Numerical methods have been developed that sample a large number of power flow parameters to find representative loading scenarios bearing SVSR geometry information. Simulation experiments are performed for each sample to determine its SVSR containment label, which manifests difficulties in keeping scalability with DC networks' growing sizes. To address this issue, we propose a network-informed numerical approach which reduces the computational workload by sample filtering and label extrapolation. First, we develop an algorithm that generalizes the SVSR-containment label of a single sample to that of an extended set to avoid dense simulations. Then, we construct an SVSR subset from the extended sets. The volume of the subset is expanded by an iterative closed-loop algorithm. In each iteration, we actively sample a small group of new parameters to label, and the revealed parameter space geometry information in turn is leveraged by a sample recommendation approach to filter samples carrying the most uncovered information for numerical labeling in future iterations. The newly labeled samples enlarge the SVSR subset, which aids in extrapolating the labels of the new samples. Case studies based on IEEE benchmark systems show that the proposed approach effectively reduces computational efforts while ensuring an SVSR subset.


  • Active Fault-Tolerant Control for Three-Level T-Type Converter With Unbalanced Neutral-Point Voltage Modulation

    by Yuhao Yao, Wentao Huang, Ran Li, Moduo Yu, Jianzhe Liu, Jun Wu

    The rectifier and inverter in the T-type back-to-back converter are interconnected via a capacitance with a DC-link midpoint. Faults in the inverter switches of the converter will result in current distortion, load power loss, and DC voltage unbalance, which subsequently impact rectifier operation and grid power quality. Whereas many studies have focused on achieving complete inner switch fault tolerance in three-level inverters, outer switch faults have typically required additional redundant hardware elements or modifications to control references to reduce output voltage amplitude. This paper proposes an active fault-tolerant control (FTC) method for three-level T-type converters with unbalanced neutral-point (NP) voltage modulation to tolerate outer switch faults. The rectifier actively induces the unbalanced NP voltage by injecting zero-sequence components and providing sufficient DC voltage support for the inverter's voltage synthesis. The inverter's separated phase FTC uses healthy legs to achieve the faulty phase voltage synthesis and injects zero-sequence components to fully exploit the DC voltage. This active FTC method avoids the use of faulty switches, maintaining normal converter operation. Hardware-in-the-loop (HIL) testing results demonstrate that the output AC current harmonics are less than 5% and the DC voltage ripples are less than 4%, verifying that the FTC achieves higher performance under various load conditions.


  • Stator Current Calculation and Validation for DFIGs With Multiple Control Strategies Under Weak Grid Faults

    by Dawei Chen, Canbing Li, Sheng Liu, Xubin Liu, Jianzhe Liu, Feilong Fan, Juan Wei

    This paper investigates the fault current characteristics of doubly-fed induction generators (DFIGs) in weak grid scenarios, addressing the limitations of existing methods that assume a predefined voltage dip and neglect the influence of DFIGs on post-fault voltage. A transient fault voltage model is proposed to accurately capture the interaction between DFIGs and weak grid impedance, which significantly affects fault current calculation. The model introduces an additional pole to account for fault voltage transients, addressing computational errors in low grid strength conditions. Furthermore, a fault current expression for DFIGs under severe faults, particularly after crowbar activation, is derived, revealing the impact of external grid impedance on transient fault currents. Case studies with expanded fault scenarios and hardware-in-loop experiments demonstrate the superiority of the proposed method over existing approaches in weak grid applications.

  • A q -Axis Current Injection Open-Circuit Fault-Tolerant Control for AFE Rectifiers in DC Marine Integrated Power Systems

    by Yuhao Yao, Wentao Huang, Ran Li, Jianzhe Liu, Yuyang Zhang, Aleksey Senkov, Canbing Li

    The dc marine integrated power system uses the active front-end (AFE) rectifiers widely to stabilize the dc bus voltage. However, AFE rectifiers are vulnerable to switch open-circuit faults, which challenge the stability and reliability of the system. Many existing works have been devoted to studying the fault-tolerant control (FTC) of rectifiers, but the adopted space vector replacement and additional control modules only compensate for the vector synthesis partly, which reduces the ability to control the dc voltage. This article proposes a q-axis current injection FTC method that enables the converter to operate normally and reduce the dc voltage ripple. The space vector model considering the coupling of control and electrical vectors is established to determine the fault deviation and affected space sectors. The faulty active vectors are reactivated by changing the q-axis current. The modified modulation is the faulty zero vector replacement realized by changing the turn-on time of each switch. The distorted reference voltage vector can be effectively revised with the q-axis current injection and the space vector fault-tolerant modulation. Hardware-in-the-loop (HIL) testing and experimental results verify that the dc voltage ripple is less than 1% under single-switch faults with the proposed method. Compared to the existing FTC methods, such as projection compensation and zero vector replacement, the dc voltage ripple with the proposed method can be reduced by 33%~89% without compromising the fault recovery time.


  • Adaptive Motor Load Control Method for Shipboard Microgrid Frequency Regulation

    by Sizhe Hu, Wentao Huang, Nengling Tai, Jianzhe Liu, Liangxiu Wang, Yuanwei Zhang

    Shipboard microgrid requires responsive resources to mitigate frequency fluctuations caused by load changes, but the responses from generators or energy storage usually incur a high cost. Alternatively, since motor drives comprise a significant portion of load, they manifest potentials for frequency regulation from the demand side. However, existing demand response framework lacks the active control of variable speed drives (VSD) for full use of motor load power reserve. This paper proposes an adaptive motor load control for VSD. The strategy synergizes the dual inertia resources in motor loads including dc-link capacitors and rotating machines to reduce the frequency deviation. A model predictive control (MPC) mechanism is presented to calculate the optimized reference value of DC voltage and motor speed, enhancing the frequency response capabilities while ensuring a controllable operating trajectory for VSD. Without additional energy storage systems, the VSD actively realizes a coordinated control between frequency and speed regulation. Additionally, the tuning of weighting factors in the control strategy, covering two operational modes, is discussed and quantitatively assessed. The capability of the proposed system to suppress grid frequency fluctuations is demonstrated through RT-LAB hardware-in-loop experiments and laboratory-scale power platform.


  • Fault Current Multi-Stages Calculation Method for DFIG-Based Wind Farms With Whole Fault Process Attributes Under Asymmetrical Grid Fault Conditions

    by Xubin Liu, Zijian Zhang, Yonglu Liu, Liang Yuan, Mei Su, Feng Zhou, Canbing Li, Jianzhe Liu, Xin Zhang, Peng Wang

    The existing imprecise fault current calculation, due to incomplete stage division of whole fault process of DFIG-based wind farms (DBWFs), brings great hidden dangers to safety and stable operation of local grid. To tackle this challenge, a fault current multi-stages calculation (FCMSC) method is proposed to accurately calculate DFIG-based wind farm's output symmetrical and asymmetrical fault currents under grid whole fault process that including fault occurrence, fault ride-through and fault recovery. The main content of FCMSC method includes: 1) Whole fault process equivalent aggregation model, which contains protection response stage, first crowbar protection stage, demagnetization operation stage, reactive current injection stage, and second crowbar protection stage, is completely established while second crowbar protection stage is firstly dissected in detail. 2) Fault current contribution mechanism, considering wind speed, is revealed to have GSC injection and absorption modes under asymmetrical grid fault conditions. 3) Fault current universal expression, which covers whole fault process operation stages and scenarios, is conducted by replacing differential equations with simple algebraic operations for improving calculation accuracy, timeliness and universality. 4) Fault current characteristic components, which contain DC components, AC stable components, and AC attenuated components, is extracted for providing key data for fault identification and protection. Extensive test results under symmetrical and asymmetrical faults are illustrated for verifying the correctness of proposed FCMSC method.


  • Adaptive Damping Ratio Control of Parallel Buck Converters for the Marine Pulsed Power Loads

    by Zhouhong Lin, Wentao Huang, Ran Li, Nengling Tai, Jianzhe Liu

    Parallel buck converters are increasingly being taken to interface pulsed power loads (PPLs) in ships. The voltage of the converters will deteriorate under the periodic power steps of PPL in a very short time. To this end, this article proposes an adaptive damping ratio control (ApDRC) for the parallel converters. The mechanism of voltage regulation is explored, enabling the voltage to be regulated directly and accurately by the damping ratio of the system. Unlike most existing controls, of which performances are parameter-associated, ApDRC is parameter-independent through adaptive damping ratio design, such that good voltage regulation can be always ensured regardless of varying changes in the load. Moreover, the load transient evolution is first investigated, revealing how duty-cycle saturation affects the load transients, and what is the corresponding solution. Experimental results demonstrate that the proposed control can achieve fast voltage regulation while having small static errors and good disturbance rejection.


  • Systematic Controller Design for Inverter-Based Microgrids With Certified Large-Signal Stability and Domain of Attraction

    by Buxin She, Jianzhe Liu, Feng Qiu, Hantao Cui, Nattapat Praisuwanna, Jingxin Wang, Leon M. Tolbert, Fangxing Li

    Inverter-based resources (IBRs) introduce fast dynamics and high non-linearities to microgrids, degrading their stability and complicating the design of effective controllers. To address the arising vulnerability and non-linearities, this paper presents a systematic controller design approach that ensures large-signal stability and domain of attraction (DOA) for islanded microgrids. First, the nonlinear electromagnetic transient model of inverter-based microgrids is developed in the rotating dq reference frame, which is then transformed to a homogeneous-like system with nonlinear terms acting as superimposed parameter uncertainties. Next, the stability conditions, including certified stability, certified DOA, and their combination, are derived to rigorously guarantee a designated range to be a subset of DOA. The designated region is customized and flexible enough to cover microgrids’ normal or emergency operational ranges, such as low- and high-voltage ride-through (L/HVRT) conditions. Then, a systematic method for identifying the candidate control parameter set is developed by integrating the analytical stability conditions. This approach is further exemplified in the droop controller design to improve microgrid stability and resilience. Finally, the proposed systematic controller design is verified through numerical simulation and power hardware-in-the-loop experiments to ensure large-signal stability and DOA of microgrids in emergency L/HVRT conditions.