SOSean O'GOrman

Sean O'GOrman

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Sean O'GOrman has a total of 7 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Characterization of an amplified piezoelectric actuator for multiple reference optical coherence tomography: erratum

    by Sean O’gOrman, Kai Neuhaus, Sergey Alexandrov, Josh Hogan, Carol Wilson, Paul M. McNamara, Martin Leahy

    This erratum is submitted to correct information regarding Fig. 8 of Appl. Opt. 57, E142 (2018) [CrossRef] .

  • Characterization of an amplified piezoelectric actuator for multiple-reference optical coherence tomography

    by Sean O’gOrman, Kai Neuhaus, Sergey Alexandrov, Josh Hogan, Carol Wilson, Paul McNamara, Martin Leahy

    The characterization of an amplified piezoelectric actuator (APA) as a new axial scanning method for multiple-reference optical coherence tomography (MR-OCT) is described. MR-OCT is a compact optical imaging device based on a recirculating reference-arm-scanning optical delay using a partial mirror that can enhance the imaging depth range by more than 10 times the reference mirror’s scanning amplitude. The scanning amplitude of the used APA was varied between 30 μm and 250 μm, depending on the scanning frequency of between 0.8 kHz and 1.2 kHz. A silver-coated miniature mirror was attached to the APA via ultraviolet-cured optical adhesive, and the light source was a super-luminescent diode with 1310 nm center wavelength and 56 nm bandwidth. The sensitivity was measured with and without the partial mirror in the reference delay line as a function of scan speed, frequency, and range, therefore providing results for MR-OCT and TD-OCT modes. It was found that the APA provides more than twice the mechanical scanning range compared to other opto-mechanic actuators, but results indicate degradation of signal-to-noise ratio and sensitivity at larger imaging depths. In conjunction with MR-OCT, the scan range of maximum 200 μm can be enhanced up to 1–1.5 mm by using a reduced amount of orders of reflections, which could be of interest to increase sensitivity in the future.


  • Open Access

    Performance Review of Multiple Reference Versus Time Domain Optical Coherence Tomography

    by Kai Neuhaus, Paul M. McNamara, Sergey Alexandrov, Sean O'GOrman, Josh Hogan, Carol Wilson, Martin J. Leahy

    We present a detailed characterization of noise sources in multiple reference optical coherence tomography (MR-OCT) compared to time-domain OCT (TD-OCT). The noise characteristics were modeled based on the TD-OCT noise model and modified for MR-OCT and confirmed with measurements. The MR-OCT sensitivity characteristics are significantly affected by the reflection from the partial mirror, which also introduces a natural attenuation in the reference arm, partially matching the reflectivity intensity profile of human tissue. At optimal balance between sample and reference arm and using balanced detection, the peak sensitivity was measured to be 95 dB, which is close to simple Fourier-domain systems. The results provide a better understanding of the application range for MR-OCT and higher order effects observed, suggesting a nontrivial noise model for MR-OCT.