HZHangwei Zhu

Hangwei Zhu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Hangwei Zhu has a total of 6 co-authors. Here are the top co-authors by number of shared publications:

  • Yanlin He

    Key Laboratory of the Ministry of Education for Optoelectronic Measurement Technology and Instrument, Beijing Information Science and Technology University, Beijing, China

    2 shared publications
  • Fei Han

    Key Laboratory of the Ministry of Education for Optoelectronic Measurement Technology and Instrument, Beijing Information Science & Technology University, Beijing 100192, China

    1 shared publication
  • Guangkai Sun

    Key Laboratory of the Ministry of Education for Optoelectronic Measurement Technology and Instrument, Beijing Information Science and Technology University, Beijing, China

    1 shared publication
  • Kangpeng Zhou

    School of Precision Instrument and Opto-electronics Engineering, Tianjin University, Tianjin, CHINA

    1 shared publication
  • Lianqing Zhu

    Beijing Information Science and Technology University

    1 shared publication
  • Likun Gao

    Key Laboratory of the Ministry of Education for Optoelectronic Measurement Technology and Instrument, Beijing Information Science & Technology University, Beijing 100192, China

    1 shared publication

Latest Publications

  • Open Access

    A Novel Catheter Shape-Sensing Method Based on Deep Learning with a Multi-Core Optical Fiber

    by Fei Han, Yanlin He, Hangwei Zhu, Kangpeng Zhou

    In this paper, we propose a novel shape-sensing method based on deep learning with a multi-core optical fiber for the accurate shape-sensing of catheters and guidewires. Firstly, we designed a catheter with embedded multi-core fiber containing three sensing outer cores and one temperature compensation middle core. Then, we analyzed the relationship between the central wavelength shift, the curvature of the multi-core Fiber Bragg Grating (FBG), and temperature compensation methods to establish a Particle Swarm Optimization (PSO) BP neural network-based catheter shape sensing method. Finally, experiments were conducted in both constant and variable temperature environments to validate the method. The average and maximum distance errors of the PSO-BP neural network were 0.57 and 1.33 mm, respectively, under constant temperature conditions, and 0.36 and 0.96 mm, respectively, under variable temperature conditions. This well-sensed catheter shape demonstrates the effectiveness of the shape-sensing method proposed in this paper and its potential applications in real surgical catheters and guidewire.


  • Open Access

    Stiffness Modelling and Performance Evaluation of a Soft Cardiac Fixator Flexible Arm with Granular Jamming

    by Likun Gao, Yanlin He, Hangwei Zhu, Guangkai Sun, Lianqing Zhu

    To meet the practical application requirements of cardiac fixation during off-pump coronary artery bypass surgery, a soft cardiac fixator with a flexible arm was previously designed. To enable the soft cardiac fixator to adapt to uncertain external forces, this study evaluates the variable-stiffness performance of the flexible arm. First, the flexible arm was simplified as a soft silicone manipulator measuring 60 mm × 90 mm × 120 mm, which can actuate, soften, or stiffen independently along the length of the arm by combining granular jamming with input pressure. Then, the soft manipulator was modelled as a cantilever beam to analyse its variable-stiffness performance with granular jamming. Next, based on theoretical analysis and calculations, many experiments were conducted to evaluate the variable-stiffness performance of the soft manipulator. The experimental results demonstrated that the variable-stiffness performance is influenced by the flexible arm length, the size of the granules, and the input pressure.