P. Forck
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
P. Forck has a total of 53 co-authors. Here are the top co-authors by number of shared publications:
- Carsten Peter Welsch
The University of Liverpool
3 shared publications - Hao Zhang
Department of Physics, University of Liverpool, Liverpool L69 7ZE, UK
3 shared publications - M. Ady
European Organization for Nuclear Research
3 shared publications - O. Sedlacek
Cockcroft Institute
3 shared publications - S. Udrea
GSI Helmholtzzentrum für Schwerionenforschung
3 shared publications - Thibaut Lefevre
CERN, European Organization for Nuclear Research
3 shared publications
Latest Publications
- Open Access
- 10 November 2025
- Published by American Physical Society (APS) in Physical Review Research
- Vol. 7 (4) , 043144
Full-cycle, noninvasive emittance monitoring with the beam gas curtain monitor at the LHC
The large energy range and high intensity of current hadron accelerators, such as the Large Hadron Collider (LHC) and its planned high-luminosity upgrade, pose great challenges to beam measurements. The Beam Gas Curtain presents an accurate, minimally invasive profile monitor with a large energy range for high-intensity beams, by exploiting fluorescence from a supersonic gas jet interacting with the accelerator particle beam. In this paper, we report for the first time the proton and lead ion beam transverse profile and emittance continuously measured throughout the whole LHC energy range.
- 10 November 2025
- Published by American Physical Society (APS) in Physical Review Research
- Vol. 7 (4) , 043144
Open AccessFull-cycle, noninvasive emittance monitoring with the beam gas curtain monitor at the LHC
The large energy range and high intensity of current hadron accelerators, such as the Large Hadron Collider (LHC) and its planned high-luminosity upgrade, pose great challenges to beam measurements. The Beam Gas Curtain presents an accurate, minimally invasive profile monitor with a large energy range for high-intensity beams, by exploiting fluorescence from a supersonic gas jet interacting with the accelerator particle beam. In this paper, we report for the first time the proton and lead ion beam transverse profile and emittance continuously measured throughout the whole LHC energy range.
- Open Access
- 12 April 2024
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 27 (4) , 043201
Beam gas curtain monitor: Vacuum studies for LHC integration and operation
A beam gas curtain (BGC) monitor has been designed to obtain information about the relative position between the LHC proton beam and the hollow electron lens electron beam through a minimally invasive process. Its working principle relies on intersecting the path of both beams with a supersonic gas curtain, introduced transversely into the LHC beamline, to produce a fluorescence signal. As an intermediate project stage (phase II), a preliminary version of the BGC monitor has been installed into the LHC beamline. To ensure the successful integration of the monitor and subsequent operation under LHC ultrahigh vacuum conditions, a series of vacuum studies have been performed. These can be classified as follows: An off-line laboratory test campaign, to assess BGC behavior during pump down and gas injections; simulations and analytical calculations, to evaluate BGC behavior and estimate the impact of its installation and operation in the LHC. This document will briefly present the off-line tests campaign, followed by a more extensive description of the simulations performed. Published by the American Physical Society 2024
- 12 April 2024
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 27 (4) , 043201
Open AccessBeam gas curtain monitor: Vacuum studies for LHC integration and operation
A beam gas curtain (BGC) monitor has been designed to obtain information about the relative position between the LHC proton beam and the hollow electron lens electron beam through a minimally invasive process. Its working principle relies on intersecting the path of both beams with a supersonic gas curtain, introduced transversely into the LHC beamline, to produce a fluorescence signal. As an intermediate project stage (phase II), a preliminary version of the BGC monitor has been installed into the LHC beamline. To ensure the successful integration of the monitor and subsequent operation under LHC ultrahigh vacuum conditions, a series of vacuum studies have been performed. These can be classified as follows: An off-line laboratory test campaign, to assess BGC behavior during pump down and gas injections; simulations and analytical calculations, to evaluate BGC behavior and estimate the impact of its installation and operation in the LHC. This document will briefly present the off-line tests campaign, followed by a more extensive description of the simulations performed. Published by the American Physical Society 2024
- Open Access
- 25 April 2022
- Published by AIP Publishing in Applied Physics Letters
- Vol. 120 (17) , 174101
A gas curtain beam profile monitor using beam induced fluorescence for high intensity charged particle beams
A minimally invasive transverse beam profile monitor based on supersonic gas curtain technology and beam-induced fluorescence has been developed and demonstrated. The concept presented can be used to measure both the profile of the proton beam in the Large Hadron Collider (LHC) and the concentricity of the electron and the proton beams in the LHC hollow electron lens. In this Letter, the performance of such a monitor for a low energy electron beam is discussed, which paves the way for its wider implementation.
- 25 April 2022
- Published by AIP Publishing in Applied Physics Letters
- Vol. 120 (17) , 174101
Open AccessA gas curtain beam profile monitor using beam induced fluorescence for high intensity charged particle beams
A minimally invasive transverse beam profile monitor based on supersonic gas curtain technology and beam-induced fluorescence has been developed and demonstrated. The concept presented can be used to measure both the profile of the proton beam in the Large Hadron Collider (LHC) and the concentricity of the electron and the proton beams in the LHC hollow electron lens. In this Letter, the performance of such a monitor for a low energy electron beam is discussed, which paves the way for its wider implementation.
- Open Access
- 1 November 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (11) , 113306
A dynamic collimation and alignment system for the Helmholtz linear accelerator
The upcoming commissioning of the superconducting (SC) continuous wave Helmholtz linear accelerators first of series cryomodule is going to demand precise alignment of the four internal SC cavities and two SC solenoids. For optimal results, a beam-based alignment method is used to reduce the misalignment of the whole cryomodule, as well as its individual components. A symmetric beam of low transverse emittance is required for this method, which is to be formed by a collimation system. It consists of two separate plates with milled slits, aligned in the horizontal and vertical direction. The collimation system and alignment measurements are proposed, investigated, and realized. The complete setup of this system and its integration into the existing environment at the GSI High Charge State Injector are presented, as well as the results of the recent reference measurements.
- 1 November 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (11) , 113306
Open AccessA dynamic collimation and alignment system for the Helmholtz linear accelerator
The upcoming commissioning of the superconducting (SC) continuous wave Helmholtz linear accelerators first of series cryomodule is going to demand precise alignment of the four internal SC cavities and two SC solenoids. For optimal results, a beam-based alignment method is used to reduce the misalignment of the whole cryomodule, as well as its individual components. A symmetric beam of low transverse emittance is required for this method, which is to be formed by a collimation system. It consists of two separate plates with milled slits, aligned in the horizontal and vertical direction. The collimation system and alignment measurements are proposed, investigated, and realized. The complete setup of this system and its integration into the existing environment at the GSI High Charge State Injector are presented, as well as the results of the recent reference measurements.
- Open Access
- 1 November 2019
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1350 (1) , 012073
Reconstruction of the longitudinal phase portrait for the SC CW heavy ion HELIAC at GSI
At the GSI Helmholtzzentrum für Schwerionenforschung (GSI) in Darmstadt, Germany, the HElmholtz LInear Accelerator (HELIAC) is currently under construction. The HELIAC comprises superconducting multigap Crossbar H-mode (SC CH) cavities. The input beam is delivered by an already existing High Charge Injector (HLI). For the further development of the accelerator a detailed knowledge of the input beam parameters to the SC section is necessary. A method for beam reconstruction is incorporated, which provides for longitudinal beam characteristics using measurements with a beam shape monitor and a particle simulation code. This finalizes the investigations on 6D beam parameters, following previous measurements in transversal phase space. The reconstruction of the longitudinal phase portrait is presented.
- 1 November 2019
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1350 (1) , 012073
Open AccessReconstruction of the longitudinal phase portrait for the SC CW heavy ion HELIAC at GSI
At the GSI Helmholtzzentrum für Schwerionenforschung (GSI) in Darmstadt, Germany, the HElmholtz LInear Accelerator (HELIAC) is currently under construction. The HELIAC comprises superconducting multigap Crossbar H-mode (SC CH) cavities. The input beam is delivered by an already existing High Charge Injector (HLI). For the further development of the accelerator a detailed knowledge of the input beam parameters to the SC section is necessary. A method for beam reconstruction is incorporated, which provides for longitudinal beam characteristics using measurements with a beam shape monitor and a particle simulation code. This finalizes the investigations on 6D beam parameters, following previous measurements in transversal phase space. The reconstruction of the longitudinal phase portrait is presented.