CJChunpeng Jiang

Chunpeng Jiang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Chunpeng Jiang has a total of 50 co-authors. Here are the top co-authors by number of shared publications:

  • Jingquan Liu

    National Key Laboratory of Advanced Micro and Nano Manufacture Technology, Shanghai Jiao Tong University 1 , Shanghai 200240

    9 shared publications
  • Gen-Cai Shen

    National Key Laboratory of Advanced Micro and Nano Manufacture Technology, Shanghai Jiao Tong University, Shanghai, China

    5 shared publications
  • Bin Yang

    Shanghai Jiao Tong University

    4 shared publications
  • Nan Zhao

    National Key Laboratory of Advanced Micro and Nano Manufacture Technology, Shanghai Jiao Tong University, Shanghai, China

    4 shared publications
  • Bin Yang

    National Key Laboratory of Advanced Micro and Nano Manufacture Technology, Shanghai Jiao Tong University, Shanghai, China

    2 shared publications
  • Nan Zhao

    Department of Micro/Nano-Electronics, National Key Laboratory of Science and Technology on Micro/Nano Fabrication, Collaborative Innovation Center of IFSA, Shanghai Jiao Tong University, Shanghai, China

    2 shared publications

Latest Publications

  • Open Access

    Assessing Cumulative Mental Fatigue via EEG-Based Machine Learning in a Multiday High-Intensity Contest

    by Xiaodong Yang, Jie Zhou, Zhan Chen, Yufei Jing, Yawei Xie, Hao Yu, Yongjie Yao, Chunpeng Jiang, Chuantao Li

    Background:Cumulative mental fatigue poses a significant threat to safety, productivity, and health in the workplace. In this study, we aimed to establish a robust machine learning framework using optimized resting-state electroencephalography (rs-EEG) features to detect such fatigue and to validate a 4-day high-stress cognitive competition paradigm for its induction.Methods:EEG signals were recorded from participants under eyes-closed (EC) and eyes-open (EO) conditions during fatigue and recovery phases. We extracted 544 features spanning power spectral density, entropy, and nonlinear complexity. Support Vector Machine Recursive Feature Elimination (SVM-RFE) was used for feature selection. The derived model index (Mean Model Result, MMR) was correlated with a subjective sleepiness index (the Stanford Sleepiness Scale, SSS) and sleep duration.Results:Analysis of participant data identified a discriminative subset of 65 features from the EC EEG. The model achieved an accuracy of 90.37% in classifying deeply fatigued versus fully recovered states, significantly outperforming the EO-based model (86.54%). The MMR demonstrated a significant negative correlation with SSS scores (rs = –0.358, p = 0.020) and a positive correlation with sleep duration (rs = 0.494, p < 0.001).Conclusions:The results of this study demonstrate the superior efficacy of EC rs-EEG for monitoring cumulative fatigue, establishing a quantifiable EEG-sleep relationship and supporting the practical feasibility of this framework for occupational fatigue risk assessment.

  • A Concentric Ring Microneedle Electrode With Low Contact Impedance for Close Sources Laplacian EEG Recording

    by Kunyu Zheng, Chunpeng Jiang, Qingda Xu, Shuihan Shao, Mengfei Xu, Bin Yang, Jingquan Liu

    Objective: Microneedle electrodes are a promising solution to the long-term collection of high-quality electroencephalography (EEG) signals without skin preparation. However, conventional microneedle electrodes still suffer from poor spatial resolution due to the volume conduction effect, which results in signal aliasing from adjacent electrodes and interference from remote sources. Methods: Here, we introduce the design, fabrication, and application of an iridium oxide (IrOx) concentric ring microneedle electrode (CRME) for surface Laplacian EEG (SLEEG) signals recording. The fabrication of a concentric ring structure with microneedles distributed on every ring is realized through high-precision 3D printing, replica molding, laser cutting, and sputtering technology, which can improve spatial resolution. Results: The contact impedance density of the IrOx CRME reduces by about 13 times compared to a common-used AgCl dry electrode and is lower than that of a standard wet electrode. Meanwhile, the IrOx CRME can acquire signals with a higher signal-noise ratio (SNR) and lower background noise. Besides, the mutual information between signals from adjacent IrOx CRMEs is lower than that from traditional microneedle electrodes (reduced from 0.8-0.9 to 0.1-0.2). The signal tests on the forehead reveal that the proposed electrodes can overcome the interference and are sensitive to close frontal lobe theta wave sources. Conclusion: The IrOx CRME shows low contact impedance, high SNR, and selectivity to close sources. Significance: This work improves traditional microneedle electrodes with combining concentric ring structure and can potentially promote the detection of the theta wave benefiting applications such as the monitoring of fatigue and stress.


  • Open Access

    Capturing forceful interaction with deformable objects using a deep learning-powered stretchable tactile array

    by Chunpeng Jiang, Wenqiang Xu, Yutong Li, Zhenjun Yu, Longchun Wang, Xiaotong Hu, Zhengyi Xie, Qingkun Liu, Bin Yang, Xiaolin Wang, et al.

    Capturing forceful interaction with deformable objects during manipulation benefits applications like virtual reality, telemedicine, and robotics. Replicating full hand-object states with complete geometry is challenging because of the occluded object deformations. Here, we report a visual-tactile recording and tracking system for manipulation featuring a stretchable tactile glove with 1152 force-sensing channels and a visual-tactile joint learning framework to estimate dynamic hand-object states during manipulation. To overcome the strain interference caused by contact with deformable objects, an active suppression method based on symmetric response detection and adaptive calibration is proposed and achieves 97.6% accuracy in force measurement, contributing to an improvement of 45.3%. The learning framework processes the visual-tactile sequence and reconstructs hand-object states. We experiment on 24 objects from 6 categories including both deformable and rigid ones with an average reconstruction error of 1.8 cm for all sequences, demonstrating a universal ability to replicate human knowledge in manipulating objects with varying degrees of deformability.


  • A Super-Adhesive and Electromagnetically Shielded Flexible Chip-Selectable and Selectable Wearable HD-sEMG Sensor

    by Nan Zhao, Gen-Cai Shen, Chun-Peng Jiang, Huimin Wen, Zude Lin, Minmin You, Xiaolin Wang, Bin Yang, Jing-Quan Liu

    High-density surface electromyography (HD-sEMG) is a non-invasive technique that covers a limited skin area with HD-sEMG sensors to measure muscle electrical activity. Therefore, HD-sEMG sensors are crucial, especially in clinical settings, and at least three areas need further improvement. Firstly, the complex electromagnetic environment in clinical practice can overwhelm the effective HD-sEMG. Secondly, the lack of adhesion between the electrode and the skin can lead to severe motion artifacts in HD-sEMG. Thirdly, different individuals have different physiological structures, especially the mandible and neck, and a single design of HD-sEMG sensors cannot adapt to many individuals, affecting subsequent clinical promotion. For this reason, we use the gel doped with poly (3,4-ethylenedioxythiophene)/poly (styrene sulfonate) (PEDOT:PSS) and MXenes mixed conductive materials that have electromagnetic shielding effect of improving the electromagnetic shielding effect of the HD-sEMG sensor so that the effective HD-sEMG signal of the individual dry swallow is unmistakable. We added a viscous agent to prepare a super adhesive gel to meet the super viscosity between the small area electrode and the skin and eliminate motion artifacts. Then, we also designed the HD-sEMG sensor as a chip selectable and optional, making the entire set of HD-sEMG sensors more suitable for subsequent clinical promotion. Finally, we collected and analyzed the multiple coughing and swallowing patterns of patients with swallowing disorders, verifying the reliability of the HD-sEMG sensor. Therefore, the HD-sEMG sensor proposed in this article can contribute to developing precision medicine and rehabilitation fields.


  • A Gelatin-Based Hydrogel Electrode With High Moisturizing Ability for Wearable EEG Recording

    by Gencai Shen, Kunyu Zheng, Chunpeng Jiang, Shuihan Shao, Nan Zhao, Jingquan Liu

    Clinically, an excellent electrode is of great significance for obtaining high-fidelity electroencephalogram (EEG) signals, which is a valuable tool for diagnosing brain-related diseases and exploring human brain activity. However, traditional wet electrode encounters a natural drawback in moisturizing ability due to the lack of water-locking ability to the electrolyte, unsuitable for long-term EEG acquisition. Hence, we propose a gelatin-based ionic conductive hydrogel electrode with a high moisturizing ability for wearable EEG acquisition. The gelatin material, derived mainly from animal collagen, is highly biocompatible and user-friendly. The gelatin-based hydrogel electrode is easy to prepare, possesses strong moisturizing ability, and performs relatively stable interfacial contact impedance. Remarkably, the gelatin-based hydrogel electrode modified by glycerol can still work normally even after 60 days. Additionally, the gelatin-based hydrogel electrode exhibits a low potential drift (1.863 μV min -1 ) and a low short-circuit noise level. This work can lead to a new era of wearable EEG acquisition and provide an effective strategy for the convenient preparation of highly moisturizing hydrogel electrodes.


  • A MEMS-Based Wearable, Flexible Embedded High-Density Sensor With Self-Adhesive PEDOT:PSS Gel for HD-sEMG Monitoring

    by Nan Zhao, Han-Jia Yang, Gen-Cai Shen, Zhuang-Zhuang Wang, Chun-Peng Jiang, Bin Yang, Jing-Quan Liu

    The gold standard for dysphagia detection is the videofluoroscopic swallowing study (VFSS), which is expensive equipment, radioactive, and carries the risk of inadvertent aspiration of contrast agents. Surface electromyography (sEMG) provides low-cost, noninvasive access to electrophysiological information and accurate temporal resolution but does not provide good spatial resolution. Five-point and nine-point Laplacian methods (FPM and NPM) can improve spatial resolution. However, metallic interfaces have high impedance and motion artifacts, especially for skin with similar neck curvature, and suffer from modulus mismatch. We designed an embedded high-density sEMG (EWHD-sEMG) sensor and reported a self-adhesive poly(3,4-ethylenedioxythiophene)/poly(styrene-sulfonate) (PEDOT:PSS) gel that can withstand 250 g of adhesion with low modulus, low contact impedance (5 kΩ) and motion artifacts, and high signal-to-noise ratio (SNR, 26 dB). The sensor is made of biocompatible materials and is structured to wear comfortably. FPM and NPM improve the SNR and reduce the correlation from 1 to 0.01. In addition, the sensor can stretch 76.9% of the strain in one thousand repetitions and withstand multiple repetitions and long-term use of numerous sterilization methods. The sensor proposed in this thesis contributes to advancing and developing an sEMG-based clinical assessment of dysphagia.


  • MEMS-Based Flexible Wearable Tri-Polar Concentric Ring Electrode Array With Self-Adhesive Graphene Gel for EEG Monitoring

    by Zhuangzhuang Wang, Nan Zhao, Gencai Shen, Chunpeng Jiang, Jingquan Liu

    Electroencephalography (EEG) is widely used to study brain activity and diagnose brain diseases due to its low cost and non-invasiveness. EEG has an excellent temporal resolution, but it does not provide good spatial resolution. The blurring effects of the head volume conductor is considered to be the main reason for the low spatial resolution. Concentric ring electrodes have been shown to provide significantly better spatial resolution than conventional electrodes which usually used silver or gold as contact conductors with the scalp. However, the metallic interfaces have high impedance. Herein, we designed a tri-polar concentric ring electrode (TCRE) array to precisely analyze the EEG signal and report a flexible self-adhesive graphene gel to reduce contact impedance. The electrodes are made of flexible material and are comfortable to wear. The electrode-scalp contact impedance was reduced to below 10 kΩ at 10 Hz and the EEG signal of alpha oscillations was successfully recorded. The average coherence between the original signals recorded by tri-polar concentric ring electrode and the commercial Ag/AgCl gel electrode reached 0.913. The TCRE also shows significantly less mutual information between positions than the disk electrodes, showing high spatial resolution.


  • A Fully Flexible Hydrogel Electrode for Daily EEG Monitoring

    by Gencai Shen, Kunpeng Gao, Nan Zhao, Zhuangzhuang Wang, Chunpeng Jiang, Jingquan Liu

    Electroencephalography (EEG) equipment and data analysis algorithms have made great progress in the field of brain-computer interfaces (BCIs). However, the development of EEG electrodes that directly contact with users is relatively slow, especially in daily EEG monitoring. The installation procedure of wet electrodes widely used in hospitals and clinics is complicated, largely limiting its application in the family. Herein, we report a fully flexible hydrogel electrode for daily EEG monitoring. The materials used in the electrode are all flexible, making it suitable for the curvature of the skin, convenient to install, and comfortable to wear. The addition of glycerol to the hydrogel enhanced its moisturizing performance, and the hydrogel still maintained a strong elasticity after being placed in the air for 90 days. The EEG signals of alpha oscillation during eyes closed were successfully collected, and the average coherence between hydrogel electrodes and Ag/AgCl wet electrodes reached 0.910. The prepared hydrogel electrode shows satisfactory performance, providing an effective strategy for daily EEG monitoring.


  • Open Access

    Self-adaptive cardiac optogenetics device based on negative stretching-resistive strain sensor

    by Wen Hong, Chunpeng Jiang, Mu Qin, Ziliang Song, Pengfei Ji, Longchun Wang, Kejun Tu, Lijun Lu, Zhejun Guo, Bin Yang, et al.

    A closed-loop and self-adaptive cardiac optogenetics is realized by a negative stretching-resistive strain sensor.


  • Tactile Sensor Array With Tertiary Leaf-Vein Structures and Position-Encoded Capacity

    by Chun-Peng Jiang, Nan Zhao, Gen-Cai Shen, Zu-De Lin, Bin Yang, Xiao-Lin Wang, Jing-Quan Liu

    Flexible tactile sensor is a preferred alternative in the development of human-machine interface (HMI) and robotics, which directly influences how we understand and interact with physical world. High density and high sensitivity tactile sensor array are urgently desired to assist people acquire tactile information of multi objects. However, although the existing researches exhibit great perception of tactile signals with different magnitudes and frequencies, they also expose limitation in the retrieval of relative position relationships. Herein, we report a wearable and high density (96 sensors on the fingertip) tactile sensor array based on tertiary leaf-vein inspired piezoresistive film. Particularly, a tertiary microstructure in the direction of height, including mid-vein-mimicking wrinkle (MVW), lateral-vein-mimicking wrinkles (LVW) and minor-vein-mimicking wrinkles (mVW), has been demonstrated an effective method to fabricate rough surface. The highly surface-controllable piezoresistive film dramatically enhances the durability (over 5000 cycles) and improves the sensitivity from 8.44 kPa -1 to 25.80 kPa -1 under 2 kPa. Accordingly, we propose an innovative position-encoded algorithm aimed at high density tactile sensor array, which has been demonstrated an excellent encode capacity of translating the multi-location tactile information caused by Braille characters into human-readable outputs. This study not only provides a map scanning method for Braille recognition, but also has significant implications for position-based information exchange or tactile encryption.