GSGen-Cai Shen

Gen-Cai Shen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Gen-Cai Shen has a total of 15 co-authors. Here are the top co-authors by number of shared publications:

  • Chunpeng Jiang

    National Key Laboratory of Advanced Micro and Nano Manufacture Technology, Shanghai Jiao Tong University, Shanghai, China

    5 shared publications
  • Jingquan Liu

    National Key Laboratory of Advanced Micro and Nano Manufacture Technology, Shanghai Jiao Tong University 1 , Shanghai 200240

    5 shared publications
  • Nan Zhao

    National Key Laboratory of Advanced Micro and Nano Manufacture Technology, Shanghai Jiao Tong University, Shanghai, China

    4 shared publications
  • Bin Yang

    Shanghai Jiao Tong University

    2 shared publications
  • Zhuang-Zhuang Wang

    Department of Micro/Nano Electronics, National Key Lab of MicroNanofabrication Technology and the DCI Joint Team, Collaborative Innovation Center of IFSA, School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai, China

    2 shared publications
  • Han-Jia Yang

    Department of Micro/Nano Electronics, National Key Lab of MicroNanofabrication Technology and the DCI Joint Team, Collaborative Innovation Center of IFSA, School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai, China

    1 shared publication

Latest Publications

  • A Super-Adhesive and Electromagnetically Shielded Flexible Chip-Selectable and Selectable Wearable HD-sEMG Sensor

    by Nan Zhao, Gen-Cai Shen, Chun-Peng Jiang, Huimin Wen, Zude Lin, Minmin You, Xiaolin Wang, Bin Yang, Jing-Quan Liu

    High-density surface electromyography (HD-sEMG) is a non-invasive technique that covers a limited skin area with HD-sEMG sensors to measure muscle electrical activity. Therefore, HD-sEMG sensors are crucial, especially in clinical settings, and at least three areas need further improvement. Firstly, the complex electromagnetic environment in clinical practice can overwhelm the effective HD-sEMG. Secondly, the lack of adhesion between the electrode and the skin can lead to severe motion artifacts in HD-sEMG. Thirdly, different individuals have different physiological structures, especially the mandible and neck, and a single design of HD-sEMG sensors cannot adapt to many individuals, affecting subsequent clinical promotion. For this reason, we use the gel doped with poly (3,4-ethylenedioxythiophene)/poly (styrene sulfonate) (PEDOT:PSS) and MXenes mixed conductive materials that have electromagnetic shielding effect of improving the electromagnetic shielding effect of the HD-sEMG sensor so that the effective HD-sEMG signal of the individual dry swallow is unmistakable. We added a viscous agent to prepare a super adhesive gel to meet the super viscosity between the small area electrode and the skin and eliminate motion artifacts. Then, we also designed the HD-sEMG sensor as a chip selectable and optional, making the entire set of HD-sEMG sensors more suitable for subsequent clinical promotion. Finally, we collected and analyzed the multiple coughing and swallowing patterns of patients with swallowing disorders, verifying the reliability of the HD-sEMG sensor. Therefore, the HD-sEMG sensor proposed in this article can contribute to developing precision medicine and rehabilitation fields.


  • A Gelatin-Based Hydrogel Electrode With High Moisturizing Ability for Wearable EEG Recording

    by Gencai Shen, Kunyu Zheng, Chunpeng Jiang, Shuihan Shao, Nan Zhao, Jingquan Liu

    Clinically, an excellent electrode is of great significance for obtaining high-fidelity electroencephalogram (EEG) signals, which is a valuable tool for diagnosing brain-related diseases and exploring human brain activity. However, traditional wet electrode encounters a natural drawback in moisturizing ability due to the lack of water-locking ability to the electrolyte, unsuitable for long-term EEG acquisition. Hence, we propose a gelatin-based ionic conductive hydrogel electrode with a high moisturizing ability for wearable EEG acquisition. The gelatin material, derived mainly from animal collagen, is highly biocompatible and user-friendly. The gelatin-based hydrogel electrode is easy to prepare, possesses strong moisturizing ability, and performs relatively stable interfacial contact impedance. Remarkably, the gelatin-based hydrogel electrode modified by glycerol can still work normally even after 60 days. Additionally, the gelatin-based hydrogel electrode exhibits a low potential drift (1.863 μV min -1 ) and a low short-circuit noise level. This work can lead to a new era of wearable EEG acquisition and provide an effective strategy for the convenient preparation of highly moisturizing hydrogel electrodes.


  • A MEMS-Based Wearable, Flexible Embedded High-Density Sensor With Self-Adhesive PEDOT:PSS Gel for HD-sEMG Monitoring

    by Nan Zhao, Han-Jia Yang, Gen-Cai Shen, Zhuang-Zhuang Wang, Chun-Peng Jiang, Bin Yang, Jing-Quan Liu

    The gold standard for dysphagia detection is the videofluoroscopic swallowing study (VFSS), which is expensive equipment, radioactive, and carries the risk of inadvertent aspiration of contrast agents. Surface electromyography (sEMG) provides low-cost, noninvasive access to electrophysiological information and accurate temporal resolution but does not provide good spatial resolution. Five-point and nine-point Laplacian methods (FPM and NPM) can improve spatial resolution. However, metallic interfaces have high impedance and motion artifacts, especially for skin with similar neck curvature, and suffer from modulus mismatch. We designed an embedded high-density sEMG (EWHD-sEMG) sensor and reported a self-adhesive poly(3,4-ethylenedioxythiophene)/poly(styrene-sulfonate) (PEDOT:PSS) gel that can withstand 250 g of adhesion with low modulus, low contact impedance (5 kΩ) and motion artifacts, and high signal-to-noise ratio (SNR, 26 dB). The sensor is made of biocompatible materials and is structured to wear comfortably. FPM and NPM improve the SNR and reduce the correlation from 1 to 0.01. In addition, the sensor can stretch 76.9% of the strain in one thousand repetitions and withstand multiple repetitions and long-term use of numerous sterilization methods. The sensor proposed in this thesis contributes to advancing and developing an sEMG-based clinical assessment of dysphagia.


  • MEMS-Based Flexible Wearable Tri-Polar Concentric Ring Electrode Array With Self-Adhesive Graphene Gel for EEG Monitoring

    by Zhuangzhuang Wang, Nan Zhao, Gencai Shen, Chunpeng Jiang, Jingquan Liu

    Electroencephalography (EEG) is widely used to study brain activity and diagnose brain diseases due to its low cost and non-invasiveness. EEG has an excellent temporal resolution, but it does not provide good spatial resolution. The blurring effects of the head volume conductor is considered to be the main reason for the low spatial resolution. Concentric ring electrodes have been shown to provide significantly better spatial resolution than conventional electrodes which usually used silver or gold as contact conductors with the scalp. However, the metallic interfaces have high impedance. Herein, we designed a tri-polar concentric ring electrode (TCRE) array to precisely analyze the EEG signal and report a flexible self-adhesive graphene gel to reduce contact impedance. The electrodes are made of flexible material and are comfortable to wear. The electrode-scalp contact impedance was reduced to below 10 kΩ at 10 Hz and the EEG signal of alpha oscillations was successfully recorded. The average coherence between the original signals recorded by tri-polar concentric ring electrode and the commercial Ag/AgCl gel electrode reached 0.913. The TCRE also shows significantly less mutual information between positions than the disk electrodes, showing high spatial resolution.


  • A Fully Flexible Hydrogel Electrode for Daily EEG Monitoring

    by Gencai Shen, Kunpeng Gao, Nan Zhao, Zhuangzhuang Wang, Chunpeng Jiang, Jingquan Liu

    Electroencephalography (EEG) equipment and data analysis algorithms have made great progress in the field of brain-computer interfaces (BCIs). However, the development of EEG electrodes that directly contact with users is relatively slow, especially in daily EEG monitoring. The installation procedure of wet electrodes widely used in hospitals and clinics is complicated, largely limiting its application in the family. Herein, we report a fully flexible hydrogel electrode for daily EEG monitoring. The materials used in the electrode are all flexible, making it suitable for the curvature of the skin, convenient to install, and comfortable to wear. The addition of glycerol to the hydrogel enhanced its moisturizing performance, and the hydrogel still maintained a strong elasticity after being placed in the air for 90 days. The EEG signals of alpha oscillation during eyes closed were successfully collected, and the average coherence between hydrogel electrodes and Ag/AgCl wet electrodes reached 0.910. The prepared hydrogel electrode shows satisfactory performance, providing an effective strategy for daily EEG monitoring.