Mohamed Taha Amen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Mohamed Taha Amen has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Benjamin Thierry
Future Industries Institute, University of South Australia, Mawson Lakes Campus, Adelaide, SA 5095, Australia
2 shared publications - Edward Cheah
Future Industries Institute, University of South Australia, Mawson Lakes Campus, Adelaide, SA 5095, Australia
2 shared publications Ahmed S. Yasin
Bio-Nanosystem Engineering Department, Chonbuk National University, Jeonju 561-756, Republic of South Korea
1 shared publication- Asad Feroze
Future Industries Institute, University of South Australia, Mawson Lakes Campus, Adelaide, SA 5095, Australia
1 shared publication - Duy Phu Tran
Future Industries Institute, University of South Australia, Mawson Lakes Campus, Adelaide, SA 5000, Australia
1 shared publication - Duy Phu Tran
Future Industries Institute, University of South Australia, Mawson Lakes Campus, Adelaide, SA 5095, Australia
1 shared publication
Latest Publications
- Open Access
- 2 December 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (23) , 12751
Exploring the Effects of Barrier Thickness and Channel Length on Performance of AlGaN/GaN HEMT Sensors Using Off-the-Shelf AlGaN/GaN Wafers
AlGaN/GaN heterostructure high electron mobility transistors (HEMTs) have exceptional characteristics, but the structure-function relationship remains to be experimentally fully studied. This study presents a systematic experimental investigation of the synergistic effects of AlGaN barrier thickness and channel length on device performance, a critical gap in the literature, which is often dominated by simulation studies. We experimentally investigated how barrier thickness and channel length influence AlGaN/GaN FET performance. We observed that the transconductance increases with decreasing AlGaN barrier thickness for shorter channel lengths (15 and 50 µm) but showed the opposite trend for the longest channel length (100 µm). Meanwhile, the subthreshold swing was predominantly influenced by the barrier thickness, with thinner barriers generally yielding lower values. These results highlight the intricate interplay between barrier thickness and channel length, providing foundational insights into the design–performance relationship of AlGaN/GaN HEMTs and guiding the development of optimized sensors for different applications.
- 2 December 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (23) , 12751
Open AccessExploring the Effects of Barrier Thickness and Channel Length on Performance of AlGaN/GaN HEMT Sensors Using Off-the-Shelf AlGaN/GaN Wafers
AlGaN/GaN heterostructure high electron mobility transistors (HEMTs) have exceptional characteristics, but the structure-function relationship remains to be experimentally fully studied. This study presents a systematic experimental investigation of the synergistic effects of AlGaN barrier thickness and channel length on device performance, a critical gap in the literature, which is often dominated by simulation studies. We experimentally investigated how barrier thickness and channel length influence AlGaN/GaN FET performance. We observed that the transconductance increases with decreasing AlGaN barrier thickness for shorter channel lengths (15 and 50 µm) but showed the opposite trend for the longest channel length (100 µm). Meanwhile, the subthreshold swing was predominantly influenced by the barrier thickness, with thinner barriers generally yielding lower values. These results highlight the intricate interplay between barrier thickness and channel length, providing foundational insights into the design–performance relationship of AlGaN/GaN HEMTs and guiding the development of optimized sensors for different applications.
- Open Access
Metal-Oxide FET Biosensor for Point-of-Care Testing: Overview and Perspective
Metal-oxide semiconducting materials are promising for building high-performance field-effect transistor (FET) based biochemical sensors. The existence of well-established top-down scalable manufacturing processes enables the reliable production of cost-effective yet high-performance sensors, two key considerations toward the translation of such devices in real-life applications. Metal-oxide semiconductor FET biochemical sensors are especially well-suited to the development of Point-of-Care testing (PoCT) devices, as illustrated by the rapidly growing body of reports in the field. Yet, metal-oxide semiconductor FET sensors remain confined to date, mainly in academia. Toward accelerating the real-life translation of this exciting technology, we review the current literature and discuss the critical features underpinning the successful development of metal-oxide semiconductor FET-based PoCT devices that meet the stringent performance, manufacturing, and regulatory requirements of PoCT.
Open AccessMetal-Oxide FET Biosensor for Point-of-Care Testing: Overview and Perspective
Metal-oxide semiconducting materials are promising for building high-performance field-effect transistor (FET) based biochemical sensors. The existence of well-established top-down scalable manufacturing processes enables the reliable production of cost-effective yet high-performance sensors, two key considerations toward the translation of such devices in real-life applications. Metal-oxide semiconductor FET biochemical sensors are especially well-suited to the development of Point-of-Care testing (PoCT) devices, as illustrated by the rapidly growing body of reports in the field. Yet, metal-oxide semiconductor FET sensors remain confined to date, mainly in academia. Toward accelerating the real-life translation of this exciting technology, we review the current literature and discuss the critical features underpinning the successful development of metal-oxide semiconductor FET-based PoCT devices that meet the stringent performance, manufacturing, and regulatory requirements of PoCT.
- Open Access
- 24 November 2021
- Published by The Royal Society in Royal Society Open Science
- Vol. 8 (11)
Rainwater-driven microbial fuel cells for power generation in remote areas
The possibility of using rainwater as a sustainable anolyte in an air-cathode microbial fuel cell (MFC) is investigated in this study. The results indicate that the proposed MFC can work within a wide temperature range (from 0 to 30°C) and under aerobic or anaerobic conditions. However, the rainwater season has a distinct impact. Under anaerobic conditions, the summer rainwater achieves a promised open circuit potential (OCP) of 553 ± 2 mV without addition of nutrients at the ambient temperature, while addition of nutrients leads to an increase in the cell voltage to 763 ± 3 and 588 ± 2 mV at 30°C and ambient temperature, respectively. The maximum OCP for the winter rainwater (492 ± 1.5 mV) is obtained when the reactor is exposed to the air (aerobic conditions) at ambient temperature. Furthermore, the winter rainwater MFC generates a maximum power output of 7 ± 0.1 mWm−2at a corresponding current density value of 44 ± 0.7 mAm−2at 30°C. While, at the ambient temperature, the maximum output power is obtained with the summer rainwater (7.2 ± 0.1 mWm−2at 26 ± 0.5 mAm−2). Moreover, investigation of the bacterial diversity indicates thatLactobacillusspp. is the dominant electroactive genus in the summer rainwater, while in the winter rainwater,Staphylococcusspp. is the main electroactive bacteria. The cyclic voltammetry analysis confirms that the electrons are delivered directly from the bacterial biofilm to the anode surface and without mediators. Overall, this study opens a new avenue for using a novel sustainable type of MFC derived from rainwater.
- 24 November 2021
- Published by The Royal Society in Royal Society Open Science
- Vol. 8 (11)
Open AccessRainwater-driven microbial fuel cells for power generation in remote areas
The possibility of using rainwater as a sustainable anolyte in an air-cathode microbial fuel cell (MFC) is investigated in this study. The results indicate that the proposed MFC can work within a wide temperature range (from 0 to 30°C) and under aerobic or anaerobic conditions. However, the rainwater season has a distinct impact. Under anaerobic conditions, the summer rainwater achieves a promised open circuit potential (OCP) of 553 ± 2 mV without addition of nutrients at the ambient temperature, while addition of nutrients leads to an increase in the cell voltage to 763 ± 3 and 588 ± 2 mV at 30°C and ambient temperature, respectively. The maximum OCP for the winter rainwater (492 ± 1.5 mV) is obtained when the reactor is exposed to the air (aerobic conditions) at ambient temperature. Furthermore, the winter rainwater MFC generates a maximum power output of 7 ± 0.1 mWm−2at a corresponding current density value of 44 ± 0.7 mAm−2at 30°C. While, at the ambient temperature, the maximum output power is obtained with the summer rainwater (7.2 ± 0.1 mWm−2at 26 ± 0.5 mAm−2). Moreover, investigation of the bacterial diversity indicates thatLactobacillusspp. is the dominant electroactive genus in the summer rainwater, while in the winter rainwater,Staphylococcusspp. is the main electroactive bacteria. The cyclic voltammetry analysis confirms that the electrons are delivered directly from the bacterial biofilm to the anode surface and without mediators. Overall, this study opens a new avenue for using a novel sustainable type of MFC derived from rainwater.