VRVijaykumar Ramaswamy

Vijaykumar Ramaswamy

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Vijaykumar Ramaswamy has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Application of Counter-Wound Multi-Arm Spirals in HTS Resonator Design

    by Taylor L. Johnston, Arthur S. Edison, Vijaykumar Ramaswamy, Nicolas Freytag, Matthew E. Merritt, Jeremy N. Thomas, Jerris W. Hooker, Ilya M. Litvak, William W. Brey

    Significant sensitivity improvements have been achieved by utilizing high temperature superconducting (HTS) resonators in nuclear magnetic resonance (NMR) probes. Many nuclei such as 13 C benefit from strong excitation fields which cannot be produced by traditional HTS resonator designs. We investigate the use of double-sided, counter-wound multi-arm spiral HTS resonators with the aim of increasing the excitation field at the required nuclear Larmor frequency for 13 C. When compared to double-sided, counter-wound spiral resonators with similar geometry, simulations indicate that the multi-arm spiral version develops a more uniform current distribution. Preliminary tests of a two-arm resonator indicate that it may produce a stronger excitation field.


  • 13C-Optimized HTS NMR RF Coil Design at 21.1 T

    by Omid Sanati, Arthur S. Edison, Lawrence A. Hornak, Ilya M. Litvak, Vijaykumar Ramaswamy, Nicolas Freytag, William W. Brey

    We present the design of a novel high-temperature superconductor double-sided racetrack resonator for a 13 C optimized nuclear magnetic resonance (NMR) transmitter/receiver coil. The coils operate in a 21.1 T magnet and accommodate a 3 mm × 6.2 mm cross-section rectangular sample tube. The design includes the incorporation of revised finger lengths to improve the homogeneity of current density across the fingers, a new laser trimming approach for adjusting the resonance frequency, and improved ability to shift higher-order modes for suitability in 1 H/ 13 C NMR probes. Resonator design methodology, simulations and experimental results are presented.


  • Open Access

    Modeling the Resonance Shifts Due to Coupling Between HTS Coils in NMR Probes

    by J N Thomas, V Ramaswamy, T L Johnston, D C Belc, N Freytag, L A Hornak, A S Edison, W W Brey

    Nuclear magnetic resonance (NMR) probes using thin-film HTS coils offer high sensitivity and are particularly suitable for small-sample applications. Typically, HTS probes are optimized for the detection of multiple nuclei and require several coils to be located within a small volume near the sample. Coupling between the coils shifts coil resonances and complicates coil trimming when tuning HTS probes. We have modeled the magnetic coupling between the coils of a 1.5-mm all-HTS NMR probe with 13C, 1H, and 2H channels. By measuring the magnetic coupling coefficients between individual coils, we solve the general coupling matrix given by KVL for six coupled resonators. Our results indicate that required trims can be accurately predicted by applying single coil trimming simulations to this magnetic coupling model. Use of the magnetic coupling model significantly improves the efficiency of tuning HTS probes.