Jan Rak
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jan Rak has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Krzysztof Aniołek
Institute of Materials Engineering, University of Silesia in Katowice, 75 Pułku Piechoty Street 1 A, 41-500 Chorzów, Poland
5 shared publications - Adrian Barylski
Institute of Materials Engineering, University of Silesia in Katowice, 41-500 Chorzów, Poland
4 shared publications - Grzegorz Dercz
Institute of Materials Engineering, University of Silesia in Katowice, 75 Pułku Piechoty Street 1 A, 41-500 Chorzów, Poland
3 shared publications - Bożena Łosiewicz
Institute of Materials Engineering, Faculty of Science and Technology, University of Silesia in Katowice, 41-500 Chorzów, Poland
2 shared publications - Izabela Matuła
Institute of Materials Engineering, University of Silesia in Katowice, 75 Pułku Piechoty Street 1 A, 41-500 Chorzów, Poland
2 shared publications - Joanna Maszybrocka
Institute of Materials Engineering, Faculty of Science and Technology, University of Silesia in Katowice, 75 Pułku Piechoty 1A, 41-500 Chorzów, Poland
2 shared publications
Latest Publications
- Open Access
The Impact of Current and Thermal Loads on the Properties of Copper Contact Wires Used in Railway Transport Systems
The paper presents the results of investigations of the effect of current heating on the microstructure and properties of copper profile contact wires used in railway traction networks. The aim of the study was to determine the effect of the contact wire temperature rising as a result of current heating on the occurrence of permanent changes in material characteristics. The tests were conducted in laboratory conditions through controlled heating of samples with a current of approx. 1500–1600 A, reaching temperatures of up to approx. 280 °C. It was found that in the temperature range of 120–200 °C, changes in the mechanical properties of the material were insignificant, while above 200 °C, a marked decrease in microhardness and a reduction in the indentation modulus were observed. The results obtained indicate that long-term current load leading to an increase in the temperature of the contact wire may cause deterioration of the mechanical properties of the material, its increased susceptibility to permanent deformation and an increased risk of damage to the traction network, which has a direct impact on the durability of contact wires and the maintenance costs of the rail transport infrastructure.
Open AccessThe Impact of Current and Thermal Loads on the Properties of Copper Contact Wires Used in Railway Transport Systems
The paper presents the results of investigations of the effect of current heating on the microstructure and properties of copper profile contact wires used in railway traction networks. The aim of the study was to determine the effect of the contact wire temperature rising as a result of current heating on the occurrence of permanent changes in material characteristics. The tests were conducted in laboratory conditions through controlled heating of samples with a current of approx. 1500–1600 A, reaching temperatures of up to approx. 280 °C. It was found that in the temperature range of 120–200 °C, changes in the mechanical properties of the material were insignificant, while above 200 °C, a marked decrease in microhardness and a reduction in the indentation modulus were observed. The results obtained indicate that long-term current load leading to an increase in the temperature of the contact wire may cause deterioration of the mechanical properties of the material, its increased susceptibility to permanent deformation and an increased risk of damage to the traction network, which has a direct impact on the durability of contact wires and the maintenance costs of the rail transport infrastructure.
- Open Access
- 6 November 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (21) , 11830
Hybrid Coatings of Chitosan-Tetracycline-Oxide Layer on Anodized Ti-13Zr-13Nb Alloy as New Drug Delivery System
Titanium alloys are widely used in orthopedic and dental implants, yet their limited bioactivity and bacterial resistance remain critical challenges. This study aimed to enhance the surface performance of a Ti-13Zr-13Nb alloy through the formation of a porous oxide layer and the application of a bioactive, drug-loaded coating. Porous oxide layers composed of Ti, Zr, and Nb oxides with fluoride incorporation were fabricated using a novel anodizing process. The fluoride-assisted electrochemical mechanism controlling oxide growth was elucidated through SEM and EDS analyses. The anodized surface exhibited reduced microhardness, beneficial for minimizing stress-shielding effects. Subsequently, chitosan–tetracycline composite coatings were produced via EPD and compared with dip-coating method. Characterization by ATR-FTIR, optical microscopy, SEM, and UV-VIS spectroscopy confirmed the formation of uniform, adherent, and moderately porous coatings with sustained drug release when produced by EPD, while dip-coated layers were less homogeneous and released the drug faster. Microhardness testing revealed improved mechanical integrity of EPD coatings. The developed chitosan–tetracycline–oxide layer system provides tunable nano/microgram-scale drug release and enhanced surface functionality, offering promising perspectives for acute and medium-term regenerative and antibacterial biomedical applications.
- 6 November 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (21) , 11830
Open AccessHybrid Coatings of Chitosan-Tetracycline-Oxide Layer on Anodized Ti-13Zr-13Nb Alloy as New Drug Delivery System
Titanium alloys are widely used in orthopedic and dental implants, yet their limited bioactivity and bacterial resistance remain critical challenges. This study aimed to enhance the surface performance of a Ti-13Zr-13Nb alloy through the formation of a porous oxide layer and the application of a bioactive, drug-loaded coating. Porous oxide layers composed of Ti, Zr, and Nb oxides with fluoride incorporation were fabricated using a novel anodizing process. The fluoride-assisted electrochemical mechanism controlling oxide growth was elucidated through SEM and EDS analyses. The anodized surface exhibited reduced microhardness, beneficial for minimizing stress-shielding effects. Subsequently, chitosan–tetracycline composite coatings were produced via EPD and compared with dip-coating method. Characterization by ATR-FTIR, optical microscopy, SEM, and UV-VIS spectroscopy confirmed the formation of uniform, adherent, and moderately porous coatings with sustained drug release when produced by EPD, while dip-coated layers were less homogeneous and released the drug faster. Microhardness testing revealed improved mechanical integrity of EPD coatings. The developed chitosan–tetracycline–oxide layer system provides tunable nano/microgram-scale drug release and enhanced surface functionality, offering promising perspectives for acute and medium-term regenerative and antibacterial biomedical applications.
- Open Access
Effect of Temperature on Thermal Oxidation Behavior of Ti-6Al-4V ELI Alloy
In this paper, the morphological, micromechanical and tribological characteristics of the Ti-6Al-4V ELI alloy after thermal oxidation (TO) were identified. TO was carried out at temperatures of 848 K, 898 K and 948 K over a period of 50 h. Microscopic examination revealed that an increase in temperature resulted in an improved uniformity of coverage and an increased oxide grain size. Micromechanical tests showed that TO of the Ti-6Al-4V ELI alloy led to an increase in hardness and deformation resistance. Following oxidation, a decrease (by approximately 10–22%) was observed in the total mechanical work of indentation, Wtotal, compared to the as-received material. The formation of protective oxide films on the Ti-6Al-4V ELI alloy also led to the improvement of tribological characteristics, both when tested under dry friction conditions and in Ringer’s solution. The sliding wear resistance increased with an increase in the oxidation temperature. However, a greater degree of wear reduction (by approximately 30–50%) was found for the lubricated contact in comparison with the dry friction tests. Surface roughness also increased with the increase in temperature.
Open AccessEffect of Temperature on Thermal Oxidation Behavior of Ti-6Al-4V ELI Alloy
In this paper, the morphological, micromechanical and tribological characteristics of the Ti-6Al-4V ELI alloy after thermal oxidation (TO) were identified. TO was carried out at temperatures of 848 K, 898 K and 948 K over a period of 50 h. Microscopic examination revealed that an increase in temperature resulted in an improved uniformity of coverage and an increased oxide grain size. Micromechanical tests showed that TO of the Ti-6Al-4V ELI alloy led to an increase in hardness and deformation resistance. Following oxidation, a decrease (by approximately 10–22%) was observed in the total mechanical work of indentation, Wtotal, compared to the as-received material. The formation of protective oxide films on the Ti-6Al-4V ELI alloy also led to the improvement of tribological characteristics, both when tested under dry friction conditions and in Ringer’s solution. The sliding wear resistance increased with an increase in the oxidation temperature. However, a greater degree of wear reduction (by approximately 30–50%) was found for the lubricated contact in comparison with the dry friction tests. Surface roughness also increased with the increase in temperature.
- Open Access
Improving the Tribological Properties of WE43 and WE54 Magnesium Alloys by Deep Cryogenic Treatment with Precipitation Hardening in Linear Reciprocating Motion
This paper presents the results of tribological tests on WE43 and WE54 magnesium alloys with rare earth metals performed in linear reciprocating motion for four different material couples (AISI 316-L steel, silicon nitride—Si3N4, WC tungsten carbide, and zirconium dioxide—ZrO2). Additionally, magnesium alloys were subjected to a complex heat treatment consisting of precipitation hardening combined with a deep cryogenic treatment. The study presents the effect of deep cryogenic treatment combined with precipitation hardening on the tribological properties of WE43 and WE54 alloys. Tribological tests revealed the most advantageous results for the magnesium alloy—AISI 316-L steel friction node. For both alloys tested after heat treatment, a nearly 2-fold reduction in specific wear rate has been achieved. Furthermore, microscopic examinations of the wear track areas and wear products were performed, and the wear mechanisms and types of wear products occurring in linear reciprocating friction were determined. Wear measurements were taken using the 3D profilometric method and compared with the results obtained from calculations performed in accordance with ASTM G133 and ASTM D7755, which were modified to improve the accuracy of the calculation results (the number of measured profiles was increased from four to eight). Appropriately selected calculation methods allow for obtaining reliable tribological test results and enabling the verification of both the most advantageous heat treatment variant and material couple, which results in an increase in the durability of the tested alloys.
Open AccessImproving the Tribological Properties of WE43 and WE54 Magnesium Alloys by Deep Cryogenic Treatment with Precipitation Hardening in Linear Reciprocating Motion
This paper presents the results of tribological tests on WE43 and WE54 magnesium alloys with rare earth metals performed in linear reciprocating motion for four different material couples (AISI 316-L steel, silicon nitride—Si3N4, WC tungsten carbide, and zirconium dioxide—ZrO2). Additionally, magnesium alloys were subjected to a complex heat treatment consisting of precipitation hardening combined with a deep cryogenic treatment. The study presents the effect of deep cryogenic treatment combined with precipitation hardening on the tribological properties of WE43 and WE54 alloys. Tribological tests revealed the most advantageous results for the magnesium alloy—AISI 316-L steel friction node. For both alloys tested after heat treatment, a nearly 2-fold reduction in specific wear rate has been achieved. Furthermore, microscopic examinations of the wear track areas and wear products were performed, and the wear mechanisms and types of wear products occurring in linear reciprocating friction were determined. Wear measurements were taken using the 3D profilometric method and compared with the results obtained from calculations performed in accordance with ASTM G133 and ASTM D7755, which were modified to improve the accuracy of the calculation results (the number of measured profiles was increased from four to eight). Appropriately selected calculation methods allow for obtaining reliable tribological test results and enabling the verification of both the most advantageous heat treatment variant and material couple, which results in an increase in the durability of the tested alloys.
- Open Access
The Effect of Changes in the Aging Temperature Combined with Deep Cryogenic Treatment on the Structure, Phase Composition, and Micromechanical Properties of the WE43 Magnesium Alloy
This paper examines the optimal aging temperature of WE43 alloy that has undergone precipitation hardening in conjunction with deep cryogenic treatment. The microstructure and phase composition were investigated, a microanalysis of the chemical composition was performed, and instrumental indentation tests were performed to determine the parameters of the micro-mechanical properties of the alloy after different heat treatment variants. It has been proven that a decrease in the aging temperature from 250 °C to 225 °C and the introduction of a deep cryogenic treatment lead to favorable changes in the microstructure of the alloy (reduction in grain size, increase in the number, and change in the type of β-phase precipitates). The changes in the alloy structure achieved by lowering the aging temperature contribute to the improvement of the micromechanical properties of the test material. The most advantageous results were recorded for an alloy subjected to solution treatment and aged at 225 °C for 24 h with deep cryogenic treatment: a 30% increase in hardness, a 10% increase in Young’s modulus, an improvement in elastic properties, and increased resistance to deformation of the alloy were shown compared to the initial (as-received) state. Raising the aging temperature to 250 °C leads to a phenomenon known as alloy overaging for both alloys after classical precipitation hardening and after deep cryogenic treatment. The results indicate the significant effectiveness of the proposed heat treatment in improving the service life of the Mg-Y-Nd-Zr (WE43) alloy.
Open AccessThe Effect of Changes in the Aging Temperature Combined with Deep Cryogenic Treatment on the Structure, Phase Composition, and Micromechanical Properties of the WE43 Magnesium Alloy
This paper examines the optimal aging temperature of WE43 alloy that has undergone precipitation hardening in conjunction with deep cryogenic treatment. The microstructure and phase composition were investigated, a microanalysis of the chemical composition was performed, and instrumental indentation tests were performed to determine the parameters of the micro-mechanical properties of the alloy after different heat treatment variants. It has been proven that a decrease in the aging temperature from 250 °C to 225 °C and the introduction of a deep cryogenic treatment lead to favorable changes in the microstructure of the alloy (reduction in grain size, increase in the number, and change in the type of β-phase precipitates). The changes in the alloy structure achieved by lowering the aging temperature contribute to the improvement of the micromechanical properties of the test material. The most advantageous results were recorded for an alloy subjected to solution treatment and aged at 225 °C for 24 h with deep cryogenic treatment: a 30% increase in hardness, a 10% increase in Young’s modulus, an improvement in elastic properties, and increased resistance to deformation of the alloy were shown compared to the initial (as-received) state. Raising the aging temperature to 250 °C leads to a phenomenon known as alloy overaging for both alloys after classical precipitation hardening and after deep cryogenic treatment. The results indicate the significant effectiveness of the proposed heat treatment in improving the service life of the Mg-Y-Nd-Zr (WE43) alloy.
- Open Access
Influence of Sandblasting Process on Tribological Properties of Titanium Grade 4 in Artificial Saliva for Dentistry Applications
Titanium Grade 4 (Ti G4) is widely used in medicine for dental implants. The failure-free life of implants depends on their properties such as resistance to wear and friction processes. This paper presents an analysis of the influence of sandblasting on tribological wear of commercial dental implants made of TiG4 in artificial saliva. Tribological wear measurements were performed in a reciprocating motion in the ball-on-disc system. The scanning electron microscopy/energy-dispersive X-ray spectroscopy (SEM/EDS) method was used to characterize the surface of the implants before and after the tribological wear test. The microhardness of Ti G4 was measured before and after sandblasting by the Vickers method. The contact angle was determined by the method of sitting drop in air. The residual stress test using the X-Ray Diffraction (XRD) single-{hkl} sin2ψ method was carried out. The compressive residual stress of 324(7) MPa and surface hardening of Ti G4 was revealed after sandblasting with Al2O3 particles of 53–75 μm in diameter. It was found that sandblasting changes the surface wettability of Ti G4. The intermediate wettability of the mechanically polished surface and the hydrophobicity of the sandblasted surface was revealed. Sandblasting reduces the tribological wear and friction coefficient of Ti G4 surface in saliva. The three-body abrasion wear mechanism was proposed to explain the tribological wear of Ti G4 in saliva.
Open AccessInfluence of Sandblasting Process on Tribological Properties of Titanium Grade 4 in Artificial Saliva for Dentistry Applications
Titanium Grade 4 (Ti G4) is widely used in medicine for dental implants. The failure-free life of implants depends on their properties such as resistance to wear and friction processes. This paper presents an analysis of the influence of sandblasting on tribological wear of commercial dental implants made of TiG4 in artificial saliva. Tribological wear measurements were performed in a reciprocating motion in the ball-on-disc system. The scanning electron microscopy/energy-dispersive X-ray spectroscopy (SEM/EDS) method was used to characterize the surface of the implants before and after the tribological wear test. The microhardness of Ti G4 was measured before and after sandblasting by the Vickers method. The contact angle was determined by the method of sitting drop in air. The residual stress test using the X-Ray Diffraction (XRD) single-{hkl} sin2ψ method was carried out. The compressive residual stress of 324(7) MPa and surface hardening of Ti G4 was revealed after sandblasting with Al2O3 particles of 53–75 μm in diameter. It was found that sandblasting changes the surface wettability of Ti G4. The intermediate wettability of the mechanically polished surface and the hydrophobicity of the sandblasted surface was revealed. Sandblasting reduces the tribological wear and friction coefficient of Ti G4 surface in saliva. The three-body abrasion wear mechanism was proposed to explain the tribological wear of Ti G4 in saliva.
- Open Access
Investigation of Micromechanical Properties and Tribological Behavior of WE43 Magnesium Alloy after Deep Cryogenic Treatment Combined with Precipitation Hardening
This study investigated the micromechanical and tribological properties of WE43 alloy (Mg-Y-Nd-Zr) alloy subjected to cryogenic treatment and precipitation hardening. Microindentation tests were carried out in the range of load from 100 to 1000 mN. The introduction of deep cryogenic treatment (DCT) was shown to increase hardness and Young’s modulus, and reduce the total indentation work. As the load set during the tests increased, a gradual decrease in the measured values was observed, indicating a significant relationship between the indent size and the value of the measured parameters. Cryogenic treatment used in conjunction with precipitation hardening (after solutioning and after aging) reduces the tribological wear of the alloy. Tests have shown an almost twofold reduction in the area of the wear trace and in the volumetric wear of the alloy, as well as a more than twofold reduction in linear wear, with relatively small fluctuations in the coefficient of friction. Abrasion was the main mechanism of wear. Areas where microcutting, adhesion and plastic deformation occurred were also observed. The results indicate the significant effectiveness of the applied heat treatment in improving the service life of the WE43 alloy containing rare earth metals.
Open AccessInvestigation of Micromechanical Properties and Tribological Behavior of WE43 Magnesium Alloy after Deep Cryogenic Treatment Combined with Precipitation Hardening
This study investigated the micromechanical and tribological properties of WE43 alloy (Mg-Y-Nd-Zr) alloy subjected to cryogenic treatment and precipitation hardening. Microindentation tests were carried out in the range of load from 100 to 1000 mN. The introduction of deep cryogenic treatment (DCT) was shown to increase hardness and Young’s modulus, and reduce the total indentation work. As the load set during the tests increased, a gradual decrease in the measured values was observed, indicating a significant relationship between the indent size and the value of the measured parameters. Cryogenic treatment used in conjunction with precipitation hardening (after solutioning and after aging) reduces the tribological wear of the alloy. Tests have shown an almost twofold reduction in the area of the wear trace and in the volumetric wear of the alloy, as well as a more than twofold reduction in linear wear, with relatively small fluctuations in the coefficient of friction. Abrasion was the main mechanism of wear. Areas where microcutting, adhesion and plastic deformation occurred were also observed. The results indicate the significant effectiveness of the applied heat treatment in improving the service life of the WE43 alloy containing rare earth metals.