Oğuz Gürses
Oğuz Gürses has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Mert Şener
BALIKESIR UNIVERSITY, FACULTY OF ENGINEERING, DEPARTMENT OF MECHANICAL ENGINEERING, MECHANICAL ENGINEERING PR
4 shared publications - Gökhan Gürlek
Ege University
3 shared publications - Aysun Baltaci
Ege Üniversitesi, Mühendislik Fakültesi, Makine Mühendisliği
2 shared publications - Levent Cetin
Izmir Katip Celebi University
2 shared publications - Aylin Sendemir Urkmez
Ege University
1 shared publication - Bekir Boyacı
R&D Department , Sun Tekstil San. ve Tic. A.Ş. , İzmir , Türkiye
1 shared publication
Latest Publications
- 5 March 2026
- Published by Field Crops Central Research Institute in Tarla Bitkileri Merkez Arastirma Enstitusu
- No. 35,p. 35-1849443
Examination of the effects of dimethyl sulfoxide on PEDOT: PSS-based materials used in thermoelectric power systems developed for intracorporeal active implanted devices
With the increasing use of active implantable medical devices (IMDs), studies to meet their energy needs have focused on wireless energy transfer and thermoelectric generators. Materials, which are one of the most critical research topics in thermoelectric power systems, are expected to have low thermal conductivity and high electrical conductivity. Recently, organic polymers, especially poly (3,4-ethylenedioxythiophene) poly styrene sulfonate, have been preferred due to concerns over the toxicity of inorganic materials. However, using solvents such as dimethyl sulfoxide to prepare high-concentration solutions of poly (3,4-ethylenedioxythiophene) poly styrene sulfonate (PEDOT: PSS) may raise biocompatibility issues. This study investigates the effects on electrical conductivity, Seebeck coefficient, and biocompatibility after mixing different dimethyl sulfoxide solutions with PEDOT: PSS. As a result of these analyses, the highest electrical conductivity, 156.15 S/cm, was achieved with a 15/85 (v/v) dimethyl sulfoxide-water solution. The highest Seebeck coefficient was obtained at 26.27 µV/K for the film prepared with a 10/90 (v/v) dimethyl sulfoxide-water solution. Biocompatibility tests were performed according to ISO 10993-5 and ISO 10993-12 standards with the L929 cell line. It revealed that higher dimethyl sulfoxide (DMSO) ratios lead to increased toxicity in PEDOT: PSS samples. Furthermore, the group with the highest biocompatibility, which shows over 70% cell viability even at a 1:1 (v/v) extract ratio, was found as the group with a 1:1 extract ratio that contains 1% PEDOT: PSS. These findings provide insights into optimizing PEDOT: PSS formulations for enhanced electrical performance while maintaining biocompatibility, contributing to the development of safer and more efficient thermoelectric power sources for implantable medical devices.
- 5 March 2026
- Published by Field Crops Central Research Institute in Tarla Bitkileri Merkez Arastirma Enstitusu
- No. 35,p. 35-1849443
Examination of the effects of dimethyl sulfoxide on PEDOT: PSS-based materials used in thermoelectric power systems developed for intracorporeal active implanted devices
With the increasing use of active implantable medical devices (IMDs), studies to meet their energy needs have focused on wireless energy transfer and thermoelectric generators. Materials, which are one of the most critical research topics in thermoelectric power systems, are expected to have low thermal conductivity and high electrical conductivity. Recently, organic polymers, especially poly (3,4-ethylenedioxythiophene) poly styrene sulfonate, have been preferred due to concerns over the toxicity of inorganic materials. However, using solvents such as dimethyl sulfoxide to prepare high-concentration solutions of poly (3,4-ethylenedioxythiophene) poly styrene sulfonate (PEDOT: PSS) may raise biocompatibility issues. This study investigates the effects on electrical conductivity, Seebeck coefficient, and biocompatibility after mixing different dimethyl sulfoxide solutions with PEDOT: PSS. As a result of these analyses, the highest electrical conductivity, 156.15 S/cm, was achieved with a 15/85 (v/v) dimethyl sulfoxide-water solution. The highest Seebeck coefficient was obtained at 26.27 µV/K for the film prepared with a 10/90 (v/v) dimethyl sulfoxide-water solution. Biocompatibility tests were performed according to ISO 10993-5 and ISO 10993-12 standards with the L929 cell line. It revealed that higher dimethyl sulfoxide (DMSO) ratios lead to increased toxicity in PEDOT: PSS samples. Furthermore, the group with the highest biocompatibility, which shows over 70% cell viability even at a 1:1 (v/v) extract ratio, was found as the group with a 1:1 extract ratio that contains 1% PEDOT: PSS. These findings provide insights into optimizing PEDOT: PSS formulations for enhanced electrical performance while maintaining biocompatibility, contributing to the development of safer and more efficient thermoelectric power sources for implantable medical devices.
- Open Access
- 1 January 2025
- Published by Centre for Evaluation in Education and Science (CEON/CEES)
- No. Session I ,p. 238-247
Protective clothing and thermal stress: Integrating cooling systems for enhanced performance
In recent years, the increase in legal regulations concerning personal protection has been accompanied by a significant growth trend in the protective clothing industry. The primary purpose of protective clothing is to provide a barrier against biological, chemical, physical, and mechanical hazards in the relevant field. However, to support the wearer's performance, these garments are also expected to maintain the body's thermal balance and manage thermal stress, depending on environmental conditions. Research in this area has shown that protective clothing used in various fields often exhibits insufficient heat and moisture transfer ability, indicating deficiencies that need to be addressed based on their intended use. Particularly in products where textile material properties are prominent and effective-such as firefighter suits, CBRN suits, and surgical gowns-there is significant potential for development and application, making them attractive for innovative studies. Within the scope of this study, the active and passive cooling systems engineered to enhance heat transfer and decrease thermal stress will be given in detail.
- 1 January 2025
- Published by Centre for Evaluation in Education and Science (CEON/CEES)
- No. Session I ,p. 238-247
Open AccessProtective clothing and thermal stress: Integrating cooling systems for enhanced performance
In recent years, the increase in legal regulations concerning personal protection has been accompanied by a significant growth trend in the protective clothing industry. The primary purpose of protective clothing is to provide a barrier against biological, chemical, physical, and mechanical hazards in the relevant field. However, to support the wearer's performance, these garments are also expected to maintain the body's thermal balance and manage thermal stress, depending on environmental conditions. Research in this area has shown that protective clothing used in various fields often exhibits insufficient heat and moisture transfer ability, indicating deficiencies that need to be addressed based on their intended use. Particularly in products where textile material properties are prominent and effective-such as firefighter suits, CBRN suits, and surgical gowns-there is significant potential for development and application, making them attractive for innovative studies. Within the scope of this study, the active and passive cooling systems engineered to enhance heat transfer and decrease thermal stress will be given in detail.
- Open Access
- 16 September 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (18) , 8335
Evaluation of Proximal Contact Tightness and Contact Area of Posterior Composite Resin Restorations
The purpose of this study is to evaluate the influence of the matrix system on proximal contact tightness (PCT) of posterior composite resin restorations. Standardized class II cavities on 180 first lower molar dentiform model teeth (Frasaco GmbH, Tettnang, Germany) were prepared. Three groups were formed considering the matrix system: Group-IM: Ivory matrix (Hahnenkratt GmbH, Königsbach-Stein, Germany), Group-OM: Omni matrix (Ultradent, South Jordan, UT, USA), and Group-PM: Palodent V3 sectional matrix (Dentsply, Charlotte, NC, USA). Teeth were restored with resin composite mounted in a manikin head to simulate the clinical environment. Proximal contact tightness (PCT) was measured using a custom-made portable dental pressure meter (PDPM), and the validation of the PCT results was performed with a histogram analysis acquired from bite-wing radiography. All data were statistically analyzed by ANOVA and t-test in SPSS software (v.27.0) (p < 0.05). PM group showed statistically tighter contacts on both mesial (PCTm: 228.28 ± 59.17 N) and distal surfaces (PCTd: 254.91 ± 65.69 N) (p > 0.05). Mesial contacts were found to be significantly tighter than distal contacts among all (p < 0.05). According to the histogram results, only in the PM group, the difference between the mesial and distal areas is significant (p < 0.05). Histogram results confirmed that the tightest contact values were achieved in the PM group, followed by the OM and IM groups, respectively (p < 0.05). The use of sectional matrix systems and separation rings is more effective in creating tighter contact than conventional matrix systems. The use of anatomical wedges will help to create a more natural approximal contour and narrow contact area.
- 16 September 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (18) , 8335
Open AccessEvaluation of Proximal Contact Tightness and Contact Area of Posterior Composite Resin Restorations
The purpose of this study is to evaluate the influence of the matrix system on proximal contact tightness (PCT) of posterior composite resin restorations. Standardized class II cavities on 180 first lower molar dentiform model teeth (Frasaco GmbH, Tettnang, Germany) were prepared. Three groups were formed considering the matrix system: Group-IM: Ivory matrix (Hahnenkratt GmbH, Königsbach-Stein, Germany), Group-OM: Omni matrix (Ultradent, South Jordan, UT, USA), and Group-PM: Palodent V3 sectional matrix (Dentsply, Charlotte, NC, USA). Teeth were restored with resin composite mounted in a manikin head to simulate the clinical environment. Proximal contact tightness (PCT) was measured using a custom-made portable dental pressure meter (PDPM), and the validation of the PCT results was performed with a histogram analysis acquired from bite-wing radiography. All data were statistically analyzed by ANOVA and t-test in SPSS software (v.27.0) (p < 0.05). PM group showed statistically tighter contacts on both mesial (PCTm: 228.28 ± 59.17 N) and distal surfaces (PCTd: 254.91 ± 65.69 N) (p > 0.05). Mesial contacts were found to be significantly tighter than distal contacts among all (p < 0.05). According to the histogram results, only in the PM group, the difference between the mesial and distal areas is significant (p < 0.05). Histogram results confirmed that the tightest contact values were achieved in the PM group, followed by the OM and IM groups, respectively (p < 0.05). The use of sectional matrix systems and separation rings is more effective in creating tighter contact than conventional matrix systems. The use of anatomical wedges will help to create a more natural approximal contour and narrow contact area.
- 28 January 2024
- Published by Springer Nature in Journal of the Brazilian Society of Mechanical Sciences and Engineering
- Vol. 46 (2) , 1-14
Review the operating frequency effect of a moving magnet type linear compressor on electrical power and efficiency
- 28 January 2024
- Published by Springer Nature in Journal of the Brazilian Society of Mechanical Sciences and Engineering
- Vol. 46 (2) , 1-14
Review the operating frequency effect of a moving magnet type linear compressor on electrical power and efficiency
- 1 March 2022
- Published by Politeknik Dergisi in Journal of Polytechnic
- Vol. 25 (1) , 169-175
Experimental Investigation of Thermoelectric Self-Cooling System for the Cooling of Ultrasonic Transducer Drivers
Electronic driver circuits are used for the driving of ultrasonic transducer systems. Due to the high frequency switching, thermal management is the main problem that has a significant effect on the reliability of the driver. Different applications are being studied to solve such overheating problems. In this study, the designed thermoelectric self-cooling system dissipates the excess heat generated in the push-pull drive circuit and improves system performance. Thermoelectric self-cooling (TSC) is a new thermoelectric application which provide the cooling of any heat-generating device without electricity consumption. This paper presents the experimental analysis of a TSC system. An experimental setup is designed on a 275W push-pull ultrasonic driver circuit. In this study, it has been shown how the performance of the thermoelectric system changes with the use of cold extender of different thicknesses. 5 and 10 mm thickness cold extenders have had a positive effect on the cooling performance of both the hot and cold surfaces of the self-cooling system. However, when the thickness of the cold extender is increased beyond the threshold, the heat capacity of the cold extender has prevented the temperature between the cold and hot surfaces to reach critical temperature differences which enables the fan to operate.
- 1 March 2022
- Published by Politeknik Dergisi in Journal of Polytechnic
- Vol. 25 (1) , 169-175
Experimental Investigation of Thermoelectric Self-Cooling System for the Cooling of Ultrasonic Transducer Drivers
Electronic driver circuits are used for the driving of ultrasonic transducer systems. Due to the high frequency switching, thermal management is the main problem that has a significant effect on the reliability of the driver. Different applications are being studied to solve such overheating problems. In this study, the designed thermoelectric self-cooling system dissipates the excess heat generated in the push-pull drive circuit and improves system performance. Thermoelectric self-cooling (TSC) is a new thermoelectric application which provide the cooling of any heat-generating device without electricity consumption. This paper presents the experimental analysis of a TSC system. An experimental setup is designed on a 275W push-pull ultrasonic driver circuit. In this study, it has been shown how the performance of the thermoelectric system changes with the use of cold extender of different thicknesses. 5 and 10 mm thickness cold extenders have had a positive effect on the cooling performance of both the hot and cold surfaces of the self-cooling system. However, when the thickness of the cold extender is increased beyond the threshold, the heat capacity of the cold extender has prevented the temperature between the cold and hot surfaces to reach critical temperature differences which enables the fan to operate.
- 1 December 2021
- Published by Adnan Menderes University in Meandros Medical and Dental Journal
- Vol. 22 (3) , 263-273
Is Manual Segmentation the Real Gold Standard for Tooth Segmentation? A Preliminary in vivo Study Using Cone-beam Computed Tomography Images
- 1 December 2021
- Published by Adnan Menderes University in Meandros Medical and Dental Journal
- Vol. 22 (3) , 263-273
Is Manual Segmentation the Real Gold Standard for Tooth Segmentation? A Preliminary in vivo Study Using Cone-beam Computed Tomography Images
- 30 June 2021
- Published by Celal Bayar Universitesi Saglık Bilimleri Enstitusu Dergisi in Celal Bayar Üniversitesi Sağlık Bilimleri Enstitüsü Dergisi
- Vol. 8 (2) , 358-365
Magnetic Catheter Navigation Systems
Son 10 yılda biyopsi ve tanı işlemleri esnasında doktor vasıtasıyla manuel ve robotik olarak gerçekleştirilen endoskopi, kolonoskopi, bronkoskopi gibi işlemlerde oluşabilecek komplikasyonları en aza indirmeye yarayacak sistemlerin üzerine çalışılmaya başlanmıştır. Bu sistemlerin en önemli özelliği yönlendirilecek kateterin manyetik özelliğe sahip olması ve elektromanyetik sistemler ile kateterin temassız bir şekilde yönlendirilmesidir. Bunun yanı sıra tedaviye yönelik başka işlemler için de manyetik özelliğe sahip kapsül, robot, ilaç taşıma sistemleri vb. araçlar geliştirilmektedir. Bu araçların yönlendirilmesi de bahsedilen sistemler aracılığıyla temassız bir şekilde gerçekleştirilebilmektedir. Bu çalışmada temassız yönlendirmeyi sağlayan manyetik kateter navigasyon sistemleri hakkında bilgi verilmektedir.
- 30 June 2021
- Published by Celal Bayar Universitesi Saglık Bilimleri Enstitusu Dergisi in Celal Bayar Üniversitesi Sağlık Bilimleri Enstitüsü Dergisi
- Vol. 8 (2) , 358-365
Magnetic Catheter Navigation Systems
Son 10 yılda biyopsi ve tanı işlemleri esnasında doktor vasıtasıyla manuel ve robotik olarak gerçekleştirilen endoskopi, kolonoskopi, bronkoskopi gibi işlemlerde oluşabilecek komplikasyonları en aza indirmeye yarayacak sistemlerin üzerine çalışılmaya başlanmıştır. Bu sistemlerin en önemli özelliği yönlendirilecek kateterin manyetik özelliğe sahip olması ve elektromanyetik sistemler ile kateterin temassız bir şekilde yönlendirilmesidir. Bunun yanı sıra tedaviye yönelik başka işlemler için de manyetik özelliğe sahip kapsül, robot, ilaç taşıma sistemleri vb. araçlar geliştirilmektedir. Bu araçların yönlendirilmesi de bahsedilen sistemler aracılığıyla temassız bir şekilde gerçekleştirilebilmektedir. Bu çalışmada temassız yönlendirmeyi sağlayan manyetik kateter navigasyon sistemleri hakkında bilgi verilmektedir.
- 1 May 2019
- Published by Elsevier in Composites Part B: Engineering
- Vol. 165, 747-753
The effect of gold electrode thicknesses on electromechanical performance of Nafion-based Ionic Polymer Metal Composite actuators
- 1 May 2019
- Published by Elsevier in Composites Part B: Engineering
- Vol. 165, 747-753
The effect of gold electrode thicknesses on electromechanical performance of Nafion-based Ionic Polymer Metal Composite actuators