Mert Şener has a total of 24 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Examination of the effects of dimethyl sulfoxide on PEDOT: PSS-based materials used in thermoelectric power systems developed for intracorporeal active implanted devices

    by Şeyma Özkan, Mert Şener, Gökhan Gürlek, Şeyma Taşdemir, Dilara Sabırtaş, Oğuz Gürses, Yoldas Seki

    With the increasing use of active implantable medical devices (IMDs), studies to meet their energy needs have focused on wireless energy transfer and thermoelectric generators. Materials, which are one of the most critical research topics in thermoelectric power systems, are expected to have low thermal conductivity and high electrical conductivity. Recently, organic polymers, especially poly (3,4-ethylenedioxythiophene) poly styrene sulfonate, have been preferred due to concerns over the toxicity of inorganic materials. However, using solvents such as dimethyl sulfoxide to prepare high-concentration solutions of poly (3,4-ethylenedioxythiophene) poly styrene sulfonate (PEDOT: PSS) may raise biocompatibility issues. This study investigates the effects on electrical conductivity, Seebeck coefficient, and biocompatibility after mixing different dimethyl sulfoxide solutions with PEDOT: PSS. As a result of these analyses, the highest electrical conductivity, 156.15 S/cm, was achieved with a 15/85 (v/v) dimethyl sulfoxide-water solution. The highest Seebeck coefficient was obtained at 26.27 µV/K for the film prepared with a 10/90 (v/v) dimethyl sulfoxide-water solution. Biocompatibility tests were performed according to ISO 10993-5 and ISO 10993-12 standards with the L929 cell line. It revealed that higher dimethyl sulfoxide (DMSO) ratios lead to increased toxicity in PEDOT: PSS samples. Furthermore, the group with the highest biocompatibility, which shows over 70% cell viability even at a 1:1 (v/v) extract ratio, was found as the group with a 1:1 extract ratio that contains 1% PEDOT: PSS. These findings provide insights into optimizing PEDOT: PSS formulations for enhanced electrical performance while maintaining biocompatibility, contributing to the development of safer and more efficient thermoelectric power sources for implantable medical devices.

  • Open Access

    Evaluation of Proximal Contact Tightness and Contact Area of Posterior Composite Resin Restorations

    by Cem Peskersoy, Mert Sener, Oguz Baris Gurses, Eda Erbil, Murat Turkun

    The purpose of this study is to evaluate the influence of the matrix system on proximal contact tightness (PCT) of posterior composite resin restorations. Standardized class II cavities on 180 first lower molar dentiform model teeth (Frasaco GmbH, Tettnang, Germany) were prepared. Three groups were formed considering the matrix system: Group-IM: Ivory matrix (Hahnenkratt GmbH, Königsbach-Stein, Germany), Group-OM: Omni matrix (Ultradent, South Jordan, UT, USA), and Group-PM: Palodent V3 sectional matrix (Dentsply, Charlotte, NC, USA). Teeth were restored with resin composite mounted in a manikin head to simulate the clinical environment. Proximal contact tightness (PCT) was measured using a custom-made portable dental pressure meter (PDPM), and the validation of the PCT results was performed with a histogram analysis acquired from bite-wing radiography. All data were statistically analyzed by ANOVA and t-test in SPSS software (v.27.0) (p < 0.05). PM group showed statistically tighter contacts on both mesial (PCTm: 228.28 ± 59.17 N) and distal surfaces (PCTd: 254.91 ± 65.69 N) (p > 0.05). Mesial contacts were found to be significantly tighter than distal contacts among all (p < 0.05). According to the histogram results, only in the PM group, the difference between the mesial and distal areas is significant (p < 0.05). Histogram results confirmed that the tightest contact values were achieved in the PM group, followed by the OM and IM groups, respectively (p < 0.05). The use of sectional matrix systems and separation rings is more effective in creating tighter contact than conventional matrix systems. The use of anatomical wedges will help to create a more natural approximal contour and narrow contact area.


  • Experimental Investigation of Thermoelectric Self-Cooling System for the Cooling of Ultrasonic Transducer Drivers

    by Mert Şener, F.Mertkan Arslan, Oğuz Gürses, Gökhan Gürlek

    Electronic driver circuits are used for the driving of ultrasonic transducer systems. Due to the high frequency switching, thermal management is the main problem that has a significant effect on the reliability of the driver. Different applications are being studied to solve such overheating problems. In this study, the designed thermoelectric self-cooling system dissipates the excess heat generated in the push-pull drive circuit and improves system performance. Thermoelectric self-cooling (TSC) is a new thermoelectric application which provide the cooling of any heat-generating device without electricity consumption. This paper presents the experimental analysis of a TSC system. An experimental setup is designed on a 275W push-pull ultrasonic driver circuit. In this study, it has been shown how the performance of the thermoelectric system changes with the use of cold extender of different thicknesses. 5 and 10 mm thickness cold extenders have had a positive effect on the cooling performance of both the hot and cold surfaces of the self-cooling system. However, when the thickness of the cold extender is increased beyond the threshold, the heat capacity of the cold extender has prevented the temperature between the cold and hot surfaces to reach critical temperature differences which enables the fan to operate.


  • Magnetic Catheter Navigation Systems

    by Özge Akbülbül, Mert Şener, Gökhan Özdemi̇r, Aylin Şendemi̇r, Ece Bayir, Tuncay Goksel, Haydar Soydaner Karakuş, Mutlu Boztepe, Levent Çeti̇n, Gökmen Atakan Türkmen, et al.

    Son 10 yılda biyopsi ve tanı işlemleri esnasında doktor vasıtasıyla manuel ve robotik olarak gerçekleştirilen endoskopi, kolonoskopi, bronkoskopi gibi işlemlerde oluşabilecek komplikasyonları en aza indirmeye yarayacak sistemlerin üzerine çalışılmaya başlanmıştır. Bu sistemlerin en önemli özelliği yönlendirilecek kateterin manyetik özelliğe sahip olması ve elektromanyetik sistemler ile kateterin temassız bir şekilde yönlendirilmesidir. Bunun yanı sıra tedaviye yönelik başka işlemler için de manyetik özelliğe sahip kapsül, robot, ilaç taşıma sistemleri vb. araçlar geliştirilmektedir. Bu araçların yönlendirilmesi de bahsedilen sistemler aracılığıyla temassız bir şekilde gerçekleştirilebilmektedir. Bu çalışmada temassız yönlendirmeyi sağlayan manyetik kateter navigasyon sistemleri hakkında bilgi verilmektedir.