TSTyler Z. Sodia

Tyler Z. Sodia

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Tyler Z. Sodia has a total of 29 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Coupling Organic Ultralong Lifetime Phosphorescence Materials with Paper-Based Bioanalytical Architectures for Autofluorescence-Free Sensing

    by Tyler Z. Sodia, Kyra E. Frank, Adrian A. Mendonsa, John M. Branning, Kevin J. Cash

    Minimizing autofluorescence is a crucial step for enhancing fluorescence-based bioanalytical assays. Although inorganic "glow-in-the-dark" persistent luminescence phosphors are commonly used to achieve this, they require rare earth elements and complex synthetic procedures. In this work, we introduce a suite of chemo- and biosensors that leverage the ultralong phosphorescence of pyrene-doped benzophenone, a fully organic host-guest material. By melt-casting the material onto cellulose, we created a modular sensor platform in which the emission is dependent on the variable absorption of the receptor-based sensor architectures. Three distinct sensing mechanisms were demonstrated: optode membranes were cast onto the paper scaffold to link ion-dependent color changes with the output, enabling "glow-in-the-dark" K+ and Na+ detection. Second, we adapted a multistep enzymatic platform for hydrogen peroxide, glucose, or lactate sensing using the peroxidase-driven oxidation of a colorimetric substrate to modulate the emission. Finally, we show that this approach also works for immunorecognition approaches by developing a paper-based enzyme-linked immunosorbent assay (ELISA) based on the same platform. The simplicity, adaptability, and low-cost fabrication of this platform highlight its potential for integrating organic ultralong phosphorescent materials into bioanalytical sensor devices for autofluorescence-free quantification. Overall, this work provides a practical framework for integrating these materials into receptor-based sensor designs.


  • Open Access

    Mini Winnies: scaled down and transparent Winogradsky columns for microscopy in microbiology education

    by Mara R. Fink, Tyler Z. Sodia, Kevin J. Cash

    Winogradsky columns were invented by Sergei Winogradsky in the 1880s and have commonly been used as a microbiology classroom learning tool in K-12 and collegiate education. However, they can be challenging to examine with microscopy. We scaled down Winogradsky columns into nuclear magnetic resonance (NMR) tubes and replaced the natural sediment with a transparent soil substitute toward the goal of observing the microbial growth under a bright-field microscope without column disassembly. Using this “Mini Winnie” approach, students can practice their microscopy skills while observing microbial growth inside the column after only days of incubation on the laboratory windowsill. Overall, we believe that the Mini Winnies provide a simple method for maximizing student engagement while giving them a greater understanding of how microorganisms interact in the environment.


  • Open Access

    The impact of zwitterionic surfactants on optode-based nanosensors via different fabrication approaches and sensing mechanisms

    by Adrian A. Mendonsa, Tyler Z. Sodia, Kevin J. Cash

    In this work, we explored the impact of zwitterionic surfactants, sulfobetaine 16 (SB-16) and a PEG-phospholipid conjugate (DSPE-PEG), on nanosensor performance. We fabricated four sensors (for Na+, K+, Al3+, and O2) and examined how these surfactants influenced various aspects, including fabrication methods, sensing mechanisms, and the incorporation of nanomaterials. Our results highlighted SB-16's role in enhancing selectivity in ion-exchange sensors (Na+ and K+) while maintaining sensitivity akin to its PEG counterpart. The liquid–liquid extraction based sensors (Al3+) were unaffected by surfactant choice, while the O2 sensors that operate via collisional quenching exhibited reduced sensitivity with SB-16 when compared to its PEG-based counterpart. Additionally, the SB-16 sensors proved adaptable to different fabrication approaches (SESE – single emulsion solvent evaporation and FNP – flash nanoprecipitation), showcased good cell viability and maintained a functional lifetime of at least five days. Furthermore, via the use of quantum dots, we showed that it is possible to incorporate other nanomaterials into the sensing phase of SB-16 sensors. Future investigations could target enhancing the pH stability of zwitterionic surfactants to further advance their applicability in sensor technologies.


  • Persistent Luminescence Nanosensors: A Generalized Optode-Based Platform for Autofluorescence-Free Sensing in Biological Systems

    by Tyler Z. Sodia, Hanna L. Tetu, Samuel C. Saccomano, Elizabeth G. Letch, John M. Branning, Adrian A. Mendonsa, Shubham Vyas, Kevin J. Cash

    Fluorescent nanosensors have revolutionized diagnostics and our ability to monitor cellular dynamics. Yet, distinguishing sensor signals from autofluorescence remains a challenge. Here, we merged optode-based sensing with near-infrared-emitting ZnGa2O4:Cr3+ persistent luminescence nanoparticles (PLNPs) to create nanocomposites for autofluorescence-free "glow-in-the-dark" sensing. Hydrophobic modification and incorporation of the persistent luminescence nanoparticles into an optode-based nanoparticle core yielded persistent luminescence nanosensors (PLNs) for five analytes (K+, Na+, Ca2+, pH, and O2) via two distinct mechanisms. We demonstrated the viability of the PLNs by quantifying K+ in fetal bovine serum, calibrating the pH PLNs in the same, and ratiometrically monitoring O2 metabolism in cultures of Saccharomyces cerevisiae, all the while overcoming their respective autofluorescence signatures. This highly modular platform allows for facile tuning of the sensing functionality, optical properties, and surface chemistry and promises high signal-to-noise ratios in complex optical environments.


  • Open Access

    Persistent Luminescence Nanosensors: A Generalized Optode-based Platform for Autofluorescence-free Sensing in Biological Systems

    by Tyler Z. Sodia, Hanna L. Tetu, Samuel C. Saccomano, Elizabeth G. Letch, Jr. John M. Branning, Adrian A. Mendonsa, Shubham Vyas, Kevin J. Cash

    Fluorescent nanosensors have drastically progressed our ability to accelerate diagnostics and quantify cellular dynamics in real time. Their modular assembly allows for facile sensor tuning, leading to a large expansion of analytes and systems that can be analyzed. Still, separating sensor signals from background optical signatures remains a major hurdle in the field. Exploiting this modular synthesis, we merged optode-based sensing with near-infrared emitting ZnGa2O4:Cr3+ persistent luminescence nanoparticles (PLNPs) to create functional nanocompo- sites for autofluorescence-free “glow-in-the-dark” sensing. We hydrophobically modified the PLNP surface with covalently bound ligands and incorporated the PLNPs into the polymeric core of optode-based nanoparticles. We demonstrate persistent luminescence nanosensors (PLNs) for five different analytes (K+, Na+, Ca2+, pH, and O2) based on two different sensing mechanisms. The PLNs allowed us to achieve autofluorescence-free quantification of K+ in fetal bovine serum and ratiometric metabolic monitoring of microbial samples with time-resolved luminescence acquisition. We foresee that this approach will allow for high signal-to-noise ratios while sensing in optically challenging samples.


  • Open Access

    Editors’ Choice—Luminescent Oxygen Sensors: Valuable Tools for Spatiotemporal Exploration of Metabolism in In Vitro Systems

    by Tyler Z. Sodia, Kevin J. Cash

    A common biological theme on Earth is the importance of oxygen, regardless of an organism’s metabolic capabilities. This commonality makes the quantification of O2 essential in understanding life as we know it. There are many sensing methods that enable researchers to measure this important analyte, but not all sensors are compatible with every system. This perspective highlights common O2 sensing formats (and recent innovations) with the goal of guiding the reader towards a sensor choice for their desired application. We emphasize the importance of exploring unfamiliar metabolic processes, commercializing new sensors, and establishing collaborations for maximizing innovation and accelerating discovery.


  • Open Access

    Nanoparticle-Based Liquid–Liquid Extraction for the Determination of Metal Ions

    by Tyler Z. Sodia, Alexa A. David, Ashley P. Chesney, Juliana N. Perri, Gwendolyn E. Gutierrez, Cecilia M. Nepple, Sydney M. Isbell, Kevin J. Cash

    Traditional liquid phase extraction techniques that use optically responsive ligands provide benefits that enable cost-efficient and rapid measurements. However, these approaches have limitations in their excessive use of organic solvents and multistep procedures. Here, we developed a simple, nanoscale extraction approach by replacing the macroscopic organic phase with hydrophobic polymeric nanoparticles that are dispersed in an aqueous feed. The concentration of analytes in polymeric nanoparticle suspensions is governed by similar partition principles to liquid–liquid phase extraction techniques. By encasing optically responsive metal ligands inside polymeric nanoparticles, we introduce a one-step metal quantification assay based on traditional two-phase extraction methodologies. As an initial proof of concept, we encapsulated bathophenanthroline (BP) inside the particles to extract then quantify Fe2+ with colorimetry in a dissolved supplement tablet and creek water. These Fe2+ nanosensors are sensitive and selective and report out with fluorescence by adding a fluorophore (DiO) into the particle core. To show that this new rapid extraction assay is not exclusive to measuring Fe2+, we replaced BP with either 8-hydroxyquinoline or bathocuproine to measure Al3+ or Cu+, respectively, in water samples. Utilizing this nanoscale extraction approach will allow users to rapidly quantify metals of interest without the drawbacks of larger-scale phase extraction approaches while also allowing for the expansion of phase extraction methodologies into areas of biological research.


  • Open Access

    Electrochemical DNA Biosensor That Detects Early Celiac Disease Autoantibodies

    by Anna B. N. Nguyen, Marcos Maldonado, Dylan Poch, Tyler Sodia, Andrew Smith, Teisha J. Rowland, Andrew J. Bonham

    Although it is estimated that more than one million Americans have celiac disease (CD), it remains challenging to diagnose. CD, an autoimmune and inflammatory response following the ingestion of gluten-containing foods, has symptoms overlapping with other diseases and requires invasive diagnostics. The gold standard for CD diagnosis involves serologic blood tests followed by invasive confirmatory biopsies. Here, we propose a less invasive method using an electrochemical DNA (E-DNA) biosensor for CD-specific autoantibodies (AABs) circulating in blood. In our approach, CD-specific AABs bind a synthetic neoepitope, causing a conformational change in the biosensor, as well as a change in the environment of an attached redox reporter, producing a measurable current reduction. We assessed the biosensor’s ability to detect CD-specific patient-derived AABs in physiological buffer as well as buffer supplemented with bovine serum. Our biosensor was able to detect AABs in a dose-dependent manner; increased signal change correlated with increased AAB concentration with an apparent dissociation constant of 0.09 ± 0.03 units/mL of AABs. Furthermore, we found our biosensor to be target-specific, with minimal off-target binding of multiple unrelated biomarkers. Future efforts aimed at increasing sensitivity in complex media may build upon the biosensor design presented here to further improve CD AAB detection and CD diagnostic tools.


  • Open Access

    LipiSensors: Exploiting Lipid Nanoemulsions to Fabricate Ionophore-Based Nanosensors

    by Alexandra L. Dailey, Meredith D. Greer, Tyler Z. Sodia, Megan P. Jewell, Tabitha A. Kalin, Kevin J. Cash

    Ionophore-based nanosensors (IBNS) are tools that enable quantification of analytes in complex chemical and biological systems. IBNS methodology is adopted from that of bulk optodes where an ion exchange event is converted to a change in optical output. While valuable, an important aspect for application is the ability to intentionally tune their size with simple approaches, and ensure that they contain compounds safe for application. Lipidots are a platform of size tunable lipid nanoemulsions with a hydrophobic lipid core typically used for imaging and drug delivery. Here, we present LipiSensors as size tunable IBNS by exploiting the Lipidot model as a hydrophobic structural support for the sensing moieties that are traditionally encased in plasticized PVC nanoparticles. The LipiSensors we demonstrate here are sensitive and selective for calcium, reversible, and have a lifetime of approximately one week. By changing the calcium sensing components inside the hydrophobic core of the LipiSensors to those sensitive for oxygen, they are also able to be used as ratiometric O2 sensitive nanosensors via a quenching-based mechanism. LipiSensors provide a versatile, general platform nanosensing with the ability to directly tune the size of the sensors while including biocompatible materials as the structural support by merging sensing approaches with the Lipidot platform.