AMAdrian A. Mendonsa

Adrian A. Mendonsa

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Adrian A. Mendonsa has a total of 21 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Modular Europium-Based Nanosensors for the Detection of Sodium and Potassium Ions

    by Adrian A. Mendonsa, Cameron L. Lyman, Logan C. Ruthardt, Raphael Lengacher, M. Andrey Joaqui-Joaqui, Mohammad Al Mesfer, Matt J. Kipper, Eszter Boros, Kevin J. Cash

    In this work, we demonstrate a modular approach to ion detection using europium (Eu) chelates as luminescent reporters in Na+- and K+-selective nanosensors. We evaluated a commercially available option (Eu­(DBM)3Phen) and synthetically derived options (Eu­(tacn-PEPA3) and Eu­(DBM)3Bipy). The sensors exhibited reversible, tunable, and selective responses to their target ions, even in the presence of biologically relevant competing species. Furthermore, Eu­(DBM)3Phen showed no degradation when the O2 concentration was varied (0–21%) but showed limitations, including a shorter luminescence lifetime (131 μs), pH sensitivity, and susceptibility to interference from divalent cations. In contrast, Eu­(tacn-PEPA3) offered a longer lifetime (549 μs), greater pH stability, and reduced ionic interference. To validate platform modularity, the chromoionophore in the sodium sensor was successfully replaced with an alternative dye (BB-dye), confirming that the gating mechanism depends on the chromoionophore selection. These findings underscore the potential of Eu-chelates for biocompatible, time-gated ion sensing, with future work focused on enhancing stability, minimizing pH sensitivity, and shifting excitation wavelengths into the NIR-II region to support in vivo imaging applications.


  • Coupling Organic Ultralong Lifetime Phosphorescence Materials with Paper-Based Bioanalytical Architectures for Autofluorescence-Free Sensing

    by Tyler Z. Sodia, Kyra E. Frank, Adrian A. Mendonsa, John M. Branning, Kevin J. Cash

    Minimizing autofluorescence is a crucial step for enhancing fluorescence-based bioanalytical assays. Although inorganic "glow-in-the-dark" persistent luminescence phosphors are commonly used to achieve this, they require rare earth elements and complex synthetic procedures. In this work, we introduce a suite of chemo- and biosensors that leverage the ultralong phosphorescence of pyrene-doped benzophenone, a fully organic host-guest material. By melt-casting the material onto cellulose, we created a modular sensor platform in which the emission is dependent on the variable absorption of the receptor-based sensor architectures. Three distinct sensing mechanisms were demonstrated: optode membranes were cast onto the paper scaffold to link ion-dependent color changes with the output, enabling "glow-in-the-dark" K+ and Na+ detection. Second, we adapted a multistep enzymatic platform for hydrogen peroxide, glucose, or lactate sensing using the peroxidase-driven oxidation of a colorimetric substrate to modulate the emission. Finally, we show that this approach also works for immunorecognition approaches by developing a paper-based enzyme-linked immunosorbent assay (ELISA) based on the same platform. The simplicity, adaptability, and low-cost fabrication of this platform highlight its potential for integrating organic ultralong phosphorescent materials into bioanalytical sensor devices for autofluorescence-free quantification. Overall, this work provides a practical framework for integrating these materials into receptor-based sensor designs.


  • Oxygen-Sensitive Optical Nanosensors: Current Advances and Future Perspectives

    by Adrian A. Mendonsa, Kevin J. Cash

    Oxygen sensing is essential across a wide range of fields, from understanding cellular metabolism and disease mechanisms to optimizing industrial and environmental processes. In this Perspective, we highlight key developments in optical architectures (at the nanometer to sub-micrometer scale), including their transduction methods and applications to in vitro, in vivo/in situ, and nonbiological systems. We also discuss future directions for the field in the domain of expanding extra/intracellular and nonbiological sensing. We address improving accessibility for nonexpert users through the need for standardized protocols and scalable production methods. Furthermore, we advocate for fostering interdisciplinary collaborations through academic incubators, conference networking, and strategic citation practices to bridge gaps between fundamental research and applied science to expand the impact of these tools to researchers outside the sensing field. Addressing these challenges will help drive the development of more versatile and widely accessible oxygen sensors, thus advancing innovation across diverse disciplines.


  • Open Access

    The impact of zwitterionic surfactants on optode-based nanosensors via different fabrication approaches and sensing mechanisms

    by Adrian A. Mendonsa, Tyler Z. Sodia, Kevin J. Cash

    In this work, we explored the impact of zwitterionic surfactants, sulfobetaine 16 (SB-16) and a PEG-phospholipid conjugate (DSPE-PEG), on nanosensor performance. We fabricated four sensors (for Na+, K+, Al3+, and O2) and examined how these surfactants influenced various aspects, including fabrication methods, sensing mechanisms, and the incorporation of nanomaterials. Our results highlighted SB-16's role in enhancing selectivity in ion-exchange sensors (Na+ and K+) while maintaining sensitivity akin to its PEG counterpart. The liquid–liquid extraction based sensors (Al3+) were unaffected by surfactant choice, while the O2 sensors that operate via collisional quenching exhibited reduced sensitivity with SB-16 when compared to its PEG-based counterpart. Additionally, the SB-16 sensors proved adaptable to different fabrication approaches (SESE – single emulsion solvent evaporation and FNP – flash nanoprecipitation), showcased good cell viability and maintained a functional lifetime of at least five days. Furthermore, via the use of quantum dots, we showed that it is possible to incorporate other nanomaterials into the sensing phase of SB-16 sensors. Future investigations could target enhancing the pH stability of zwitterionic surfactants to further advance their applicability in sensor technologies.


  • Persistent Luminescence Nanosensors: A Generalized Optode-Based Platform for Autofluorescence-Free Sensing in Biological Systems

    by Tyler Z. Sodia, Hanna L. Tetu, Samuel C. Saccomano, Elizabeth G. Letch, John M. Branning, Adrian A. Mendonsa, Shubham Vyas, Kevin J. Cash

    Fluorescent nanosensors have revolutionized diagnostics and our ability to monitor cellular dynamics. Yet, distinguishing sensor signals from autofluorescence remains a challenge. Here, we merged optode-based sensing with near-infrared-emitting ZnGa2O4:Cr3+ persistent luminescence nanoparticles (PLNPs) to create nanocomposites for autofluorescence-free "glow-in-the-dark" sensing. Hydrophobic modification and incorporation of the persistent luminescence nanoparticles into an optode-based nanoparticle core yielded persistent luminescence nanosensors (PLNs) for five analytes (K+, Na+, Ca2+, pH, and O2) via two distinct mechanisms. We demonstrated the viability of the PLNs by quantifying K+ in fetal bovine serum, calibrating the pH PLNs in the same, and ratiometrically monitoring O2 metabolism in cultures of Saccharomyces cerevisiae, all the while overcoming their respective autofluorescence signatures. This highly modular platform allows for facile tuning of the sensing functionality, optical properties, and surface chemistry and promises high signal-to-noise ratios in complex optical environments.


  • Open Access

    Persistent Luminescence Nanosensors: A Generalized Optode-based Platform for Autofluorescence-free Sensing in Biological Systems

    by Tyler Z. Sodia, Hanna L. Tetu, Samuel C. Saccomano, Elizabeth G. Letch, Jr. John M. Branning, Adrian A. Mendonsa, Shubham Vyas, Kevin J. Cash

    Fluorescent nanosensors have drastically progressed our ability to accelerate diagnostics and quantify cellular dynamics in real time. Their modular assembly allows for facile sensor tuning, leading to a large expansion of analytes and systems that can be analyzed. Still, separating sensor signals from background optical signatures remains a major hurdle in the field. Exploiting this modular synthesis, we merged optode-based sensing with near-infrared emitting ZnGa2O4:Cr3+ persistent luminescence nanoparticles (PLNPs) to create functional nanocompo- sites for autofluorescence-free “glow-in-the-dark” sensing. We hydrophobically modified the PLNP surface with covalently bound ligands and incorporated the PLNPs into the polymeric core of optode-based nanoparticles. We demonstrate persistent luminescence nanosensors (PLNs) for five different analytes (K+, Na+, Ca2+, pH, and O2) based on two different sensing mechanisms. The PLNs allowed us to achieve autofluorescence-free quantification of K+ in fetal bovine serum and ratiometric metabolic monitoring of microbial samples with time-resolved luminescence acquisition. We foresee that this approach will allow for high signal-to-noise ratios while sensing in optically challenging samples.


  • Triplet–Triplet Annihilation Upconversion-Based Oxygen Sensors to Overcome the Limitation of Autofluorescence

    by Adrian A. Mendonsa, Cassandra C. Soeldner, Natalie E. Mudd, Samuel C. Saccomano, Kevin J. Cash

    Autofluorescence is one of the many challenges in bioimaging as it can mask the emission from fluorescent probes or markers, a limitation that can be overcome via upconversion. Herein, we have developed a nanosensor that uses triplet-triplet annihilation upconversion to optically report changes in the dissolved oxygen concentration. Using a sensitizer-annihilator dye pairing of platinum(II) octaethylporphyrin and 9,10-diphenylanthracene, we monitored the oxygen consumption (as a proxy for metabolic activity) over time in a biological system─Saccharomyces cerevisiae (brewing yeast). The nanosensor demonstrated good reversibility over multiple cycles and showed good signal and colloidal stability when tested over the course of 7 days, and it was sensitive to dissolved oxygen from 0.00 to 3.17 mg/L O2. Additionally, there was no signal overlap between the nanosensor emission and S. cerevisiae autofluorescence, thus underscoring the utility of upconversion as a facile and economical means of overcoming autofluorescence.