Ana Catarina Ângelo
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ana Catarina Ângelo has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Carlos Quental
IDMEC, Instituto Superior Técnico, Universidade de Lisboa, Lisbon, Portugal
2 shared publications - Clara de Campos Azevedo
Shoulder and Elbow Unit Department of Orthopaedic Surgery Hospital dos SAMS de Lisboa Lisbon Portugal
2 shared publications - João Folgado
IDMEC, Instituto Superior Técnico, Universidade de Lisboa, Lisbon, Portugal
2 shared publications - Madalena Antunes
IDMEC, Instituto Superior Técnico, Universidade de Lisboa, Lisbon, Portugal, Lisbon, Portugal
1 shared publication - Rita Martins
IDMEC, Instituto Superior Técnico, Universidade de Lisboa, Av. Rovisco Pais, 1049-001 Lisboa, Portugal
1 shared publication
Latest Publications
- Open Access
Influence of Graft Positioning during the Latarjet Procedure on Shoulder Stability and Articular Contact Pressure: Computational Analysis of the Bone Block Effect
The Latarjet procedure is the most popular surgical procedure to treat anterior glenohumeral (GH) instability in the presence of large anterior glenoid bone defects. Even though the placement of the bone graft has a considerable influence on its efficacy, no clear indications exist for the best graft position. The aim of this study was to investigate the influence of the medial–lateral positioning of the bone graft on the contact mechanics and GH stability due to the bone block effect. Four finite element (FE) models of a GH joint, with a 20% glenoid bone defect, treated by the Latarjet procedure were developed. The FE models differed in the medial–lateral positioning of the bone graft, ranging from a flush position to a 4.5 mm lateral position with respect to the flush position. All graft placement options were evaluated for two separate shoulder positions. Anterior GH instability was simulated by translating the humeral head in the anterior direction, under a permanent compressive force, until the peak translation force was reached. Joint stability was computed as the ratio between the shear and the compressive components of the force. The lateralization of the bone graft increased GH stability due to the bone block effect after a 3 mm lateralization with respect to the flush position. The increase in GH stability was associated with a concerning increase in peak contact pressure due to the incongruous contact between the articulating surfaces. The sensitivity of the contact pressures to the medial–lateral positioning of the bone graft suggests a trade-off between GH stability due to the bone block effect and the risk of osteoarthritis, especially considering that an accurate and consistent placement of the bone graft is difficult in vivo.
Open AccessInfluence of Graft Positioning during the Latarjet Procedure on Shoulder Stability and Articular Contact Pressure: Computational Analysis of the Bone Block Effect
The Latarjet procedure is the most popular surgical procedure to treat anterior glenohumeral (GH) instability in the presence of large anterior glenoid bone defects. Even though the placement of the bone graft has a considerable influence on its efficacy, no clear indications exist for the best graft position. The aim of this study was to investigate the influence of the medial–lateral positioning of the bone graft on the contact mechanics and GH stability due to the bone block effect. Four finite element (FE) models of a GH joint, with a 20% glenoid bone defect, treated by the Latarjet procedure were developed. The FE models differed in the medial–lateral positioning of the bone graft, ranging from a flush position to a 4.5 mm lateral position with respect to the flush position. All graft placement options were evaluated for two separate shoulder positions. Anterior GH instability was simulated by translating the humeral head in the anterior direction, under a permanent compressive force, until the peak translation force was reached. Joint stability was computed as the ratio between the shear and the compressive components of the force. The lateralization of the bone graft increased GH stability due to the bone block effect after a 3 mm lateralization with respect to the flush position. The increase in GH stability was associated with a concerning increase in peak contact pressure due to the incongruous contact between the articulating surfaces. The sensitivity of the contact pressures to the medial–lateral positioning of the bone graft suggests a trade-off between GH stability due to the bone block effect and the risk of osteoarthritis, especially considering that an accurate and consistent placement of the bone graft is difficult in vivo.
- Open Access
Shoulder Positioning during Superior Capsular Reconstruction: Computational Analysis of Graft Integrity and Shoulder Stability
The shoulder position during fixation of the graft may be a key factor impacting the outcome of arthroscopic superior capsular reconstruction (ASCR) in irreparable rotator cuff tears (IRCTs). However, biomechanical evidence regarding this effect is lacking. The aim of this study was to evaluate the influence of the shoulder position during fixation of the graft on shoulder stability and graft tear risk in ASCR. A 3-D musculoskeletal model of the upper limb was modified to account for the fixation of the graft in ASCR, assuming a full-thickness tear of the supraspinatus tendon. The concomitant tenotomy of the long head of the biceps (LHB) tendon was also studied. The biomechanical parameters evaluated included the strain of the graft and the glenohumeral joint reaction force (GH JRF), which were used to evaluate graft integrity and shoulder stability, respectively. Fixation of the graft considering abduction angles greater than 15° resulted in a high risk for graft tearing when the arm was adducted to the side of the trunk. For abduction angles below 15°, the mean shoulder stability improved significantly, ranging between 6% and 20% (p < 0.001), compared with that in the preoperative condition. The concomitant tenotomy of the LHB tendon resulted in loss of stability when compared to ASCR with an intact LHB tendon. The position of the shoulder during fixation of the graft has a significant effect on shoulder stability and graft tear risk after ASCR in IRCTs. This study provides new and important information regarding the role of shoulder positioning during fixation of the graft.
Open AccessShoulder Positioning during Superior Capsular Reconstruction: Computational Analysis of Graft Integrity and Shoulder Stability
The shoulder position during fixation of the graft may be a key factor impacting the outcome of arthroscopic superior capsular reconstruction (ASCR) in irreparable rotator cuff tears (IRCTs). However, biomechanical evidence regarding this effect is lacking. The aim of this study was to evaluate the influence of the shoulder position during fixation of the graft on shoulder stability and graft tear risk in ASCR. A 3-D musculoskeletal model of the upper limb was modified to account for the fixation of the graft in ASCR, assuming a full-thickness tear of the supraspinatus tendon. The concomitant tenotomy of the long head of the biceps (LHB) tendon was also studied. The biomechanical parameters evaluated included the strain of the graft and the glenohumeral joint reaction force (GH JRF), which were used to evaluate graft integrity and shoulder stability, respectively. Fixation of the graft considering abduction angles greater than 15° resulted in a high risk for graft tearing when the arm was adducted to the side of the trunk. For abduction angles below 15°, the mean shoulder stability improved significantly, ranging between 6% and 20% (p < 0.001), compared with that in the preoperative condition. The concomitant tenotomy of the LHB tendon resulted in loss of stability when compared to ASCR with an intact LHB tendon. The position of the shoulder during fixation of the graft has a significant effect on shoulder stability and graft tear risk after ASCR in IRCTs. This study provides new and important information regarding the role of shoulder positioning during fixation of the graft.