EME. E. Maiorov

E. E. Maiorov

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


E. E. Maiorov has a total of 34 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Investigation of the microrelief of the surfaces of dental instruments for finishing restorations made of composite materials with a low-coherence interference installation

    by L.I. Shalamai, E.Y. Mendosa, E.E. Maiorov, V.B. Lampusova, N.S. Oksas, E.Y. Nechai

    A study of the microrelief of the surfaces of dental polishes for finishing composite and compomeric restorations with a low-coherence interference installation has been carried out. The study of the surface of instruments by optical methods and means is an objective, new and economically feasible method of research in medicine, applicable including in dentistry, therefore the work is relevant and promising. The paper defines the purpose of the research, sets the task and provides the objects and method of measurement. A functional diagram of a low-coherence interference installation is presented. The values of the distances to the surface of the working surfaces of polishes are obtained with linear movement of the surface of the polish along the OX and OY axes. The distribution of the reflection coefficient from the surface of the diameter (surface of the main cylindrical working part) and height of the working part (cone-shaped tip) of polishes is investigated, which objectively characterizes the grain size of the abrasive filler and the polishing ability of the tools. Material and methods. The research material was domestic and foreign products designed for step-by-step mechanical finishing of the surface of restorations — cone-shaped polishes for an angular tip based on urethane and silicone: Kagayaki Ensmart Pin 125, Kagayaki Ensmart Pin 70, Kagayaki Ensmart Pin 32 (Kagayaki, Russia); Enhance (Dentsply Sirona, USA); Comprehol Plus Diatech 2303RA, Composhine Plus Diatech 2403RA (Coltene, Switzerland). A developed low-coherence interference installation was used to conduct experimental studies. Results and discussion. The distances to the surface of the working surfaces of polishes when the surface of the polish is linearly moved along the OX and OY axes in increments of 100 microns relative to the light beam are obtained. It was revealed that the Kagayaki, Dentsply Sirona, Coltene polishes have a greater abrasion of the surface of the diameter of the working part than the surface of the height of the working part. Conclusion. The distributions of the reflection coefficient from the surface of the diameter and height of the working part of the polishes are analyzed.

  • Study of the penetration depth into dentin of sealers based on epoxy resins and eugenol during root canal filling using the partially coherent interference method

    by L.I. Shalamai, E.YU. Mendosa, E.E. Maiorov, V.YU. Vashneva, A.V. Yartseva, S.S. Ermaeva

    Objective. To study the depth of penetration into the dentin of root canals of teeth sealer for filling root canals partially coherent interferential tomograph. Material and methods. Studied instrumentally and medicamentally treated root canals of seven removed according to clinical indications permanent teeth before obturations and after their filling by the method of lateral compaction of gutta-percha pins with the use of sealer based on epoxy resins and eugenol. The teeth were divided into 3 groups. In group 1, root canal obturation was performed using the AN Plus sealer (based on epoxy resins); in group 2, using the Vyadent sealer (based on epoxy resins); and in group 3, using the Tiedent zinc oxide eugenol cement as the sealer. The reflection coefficient was measured in 20 root canals. A partially coherent interferometric tomograph was used to study the penetration of the dental sealer into the hard tissues of the tooth roots. The study involved. sections of tooth roots corresponding to the boundaries of the mouth and middle third of the root canals. Results. The dependence of the reflection coefficient on the depth of the hard tissues of each sample’s root was obtained after instrumental and medicamentous treatment of the root canal before and after obturation. It has been established that the AH-Plus epoxy-amine sealer from Dentsply penetrates 50 to 100 microns deeper into the hard tissues of the tooth root canal than the Vyadent and Tiedent sealer from VladMiVa. The Tiedent zinc oxide eugenol filling material demonstrated better penetration into the dentin structure of the root canal compared to the Vyadent epoxy-based sealer. All of the tested sealants had a penetration depth of at least 200 microns. Conclusion. All the presented samples can be used to fill root canals without compromising the quality of restoration.

  • Comparative analysis of domestic and foreign composite materials of light curing by experimental colorimetric installation

    by L.I. Shalamai, E.YU. Mendosa, E.E. Maiorov, V.B. Lampusova, N.S. Oksas, S.A. Kosov

    The paper considers the issues of research of domestic and foreign composite materials of light curing by an experimental colorimetric installation. Obtaining information, reliable and high-precision data on the chromaticity parameters of composite materials has always been a significant task for the aesthetics of restorations on hard tooth tissues, therefore, the work is promising and relevant. The paper defines the purpose of the research, sets the task and presents the objects and method of measurements. The technical characteristics of the digital colorimetric installation are given. The color parameters of the studied composite materials were obtained in the color coordinate systems: XYZ, CIELab, HSL. It is revealed that domestic composite materials are not inferior to foreign analogues in terms of color parameters. Material and methods. The objects of the study were domestic composite materials Dentlight shade EA2 (VladMiVa SEZ, Russia), Estelux NK shade EA2 (Stomadent LLC, Russia) and foreign composite materials Harmonize Univversal shade A2E (Kerr, USA), Palfique estelite paste shade A2 (Tokuyama Dental Corporation, Japan). A developed digital colorimetric device was used to conduct experimental studies. Results. The color parameters of the studied samples from different manufacturers were obtained. A comparative analysis of domestic and foreign composite materials of light curing in different color coordinate systems with a digital colorimetric installation is carried out. The control of materials at the level of visually distinguishable shades of color is ensured.

  • Investigation of the effect of temperature and curing time on the optical properties of composite materials by absorption spectroscopy

    by L.I. Shalamai, E.YU. Mendosa, E.E. Maiorov, V.B. Lampusova, N.S. Oksas, S.A. Kosov

    Relevance. This work is devoted to the study of the effect of temperature and curing time on the optical properties of composite materials by absorption spectroscopy. It is promising to use spectrophotometers to study the optical properties of composite materials, since these devices provide reliable, reliable and highly accurate information about the object under study. The purpose of the research is defined, the task is set and the objects and method of measurements are given. The optical scheme and technical parameters of the device are given. Spectral dependences of the absorption coefficient K(λ) of «Estelite Asteria» samples of the B3B hue were obtained at different exposure times and at different temperatures. It was revealed that the exposure time (t=10 s, t=20 s) and temperature (T=0°C, T=36.5°C, T=47°C) do not affect the quality of restorations. Material and methods. Light-curing X-ray contrast composite materials were measured, designed to create restorations for cavities of all classes of hard dental tissues from Tokuyama Dental (Japan): Estelite Asteria shade B3B at temperatures: T=0°C, T=36.5°C, T=47°C and exposure time: 10 s and 20 s. A UV-3600i Plus spectrophotometer from Shimadzu (Japan) was used to conduct experimental studies. Results and discussion. The obtained optical parameters for the Estelite Asteria material of B3B shade at exposure time t=10 s, t=20 s and temperature: T=0°C, T=36.5°C, T=47°C are significant for therapeutic dentistry. Conclusion. These data show how the structure of the material (crystal lattice) changes and what happens at the atomic and molecular level.

  • Experimental measuring system for control of aircraft hull surfaces

    by E.E. Maiorov, G.A. Kostin, T.A. Chernyak

    EXPERIMENTAL MEASURING SYSTEM FOR CONTROL OF AIRCRAFT HULL SURFACES

  • INVESTIGATION OF OPTICAL FLAT SURFACES OF BEAM-SPLITTING PLATES BY MEANS OF COHERENT OPTICS

    by E. E. Maiorov, V. B. Kotskovich, V. P. Pushkina, A. V. Arefiev, R. B. Guliyev, A. V. Dagaev

    The article presents an experimental setup for measuring the geometric parameters of optical surfaces of details. The relevance of the work is shown since obtaining high-precision and reliable information about the geometric parameters of surfaces has always been an important task of metrology. The paper highlights the optical layout of the interferometer, as well as the technical and operational characteristics of the experimental setup. The objects and method of research are determined. Interferograms were obtained from the surfaces of beam splitters from various manufacturers. The images of interference fields were analyzed, and the main parameters of wave fronts were revealed. The optical surfaces were controlled by an experimental setup with an accuracy of not worse than 0.05 λ. The reflective coatings of beam splitters were studied, and the dependences of the reflection coefficient on the x and y coordinates were obtained. Comparative analysis revealed the preferable option for modern automated interferometers.

  • REFRACTOMETRIC MEANS OF CONTROL OF AQUEOUS SOLUTIONS OF TETRACHLOROETHYLENE

    by A. V. Arefiev, R. B. Guliyev, O. V. Gromov, A. V. Dagaev, V. V. Kurlov, E. E. Maiorov, I. S. Tayurskaya

    The paper a refractometric device (URL-1) for measuring the concentration dependence of the refractive index in aqueous solutions of tetrachloroethylene is considered. The presented study is relevant and promising, since the identification of optical parameters in these media is important for chemical industries. The article the appearance of a laboratory refractometric installation, as well as technical and operational characteristics of refractometers used in measurements are presented. The results of measurements of the concentration dependence of the refractive index of the studied substances were obtained experimentally, which were compared with reference values from the scientific literature. The data of experimental measurements and reference values are compared with the results obtained on the K-Patents OY PR-03-M refractometer. The error of the experiment did not exceed k ≤ 0.4%.

  • EXAMINATION OF DISINFECTANTS USING AN AUTOMATED SPECTROMETER OPERATING IN THE VISIBLE RANGE OF THE SPECTRUM

    by E. E. Maiorov, S. V. Kolesnichenko, G. A. Tsygankova, A. C. Mashek, A. A. Konstantinova, Saint Petersburg Military Academy Of Telecommunications Named. S.M. Budyonny, E. A. Pisareva, Saint Petersburg Mikhailovskaya Military Artillery Academy

    The paper highlights a modern spectral device for measuring the optical parameters of solid-state materials in liquid-phase. The development of these devices is promising for optical instrumentation and science in general, since these devices are informative, highly accurate and provide reliable information. In the paper the appearance, block diagram and lighting system of the spectrometer are presented. The spectral dependences of the transmission on the wavelength in the visible range of the spectrum for disinfectants Like, Grand, Aqualite (1% solutions) are obtained. For the analysis of the studied substances, specialized cuvettes with a working length from 0.1 to 0.5 mm and leucosapfir optical pads were used. The cuvettes were 0.05 mm thick. The spectrometer provided measurement of the transmission of disinfectants in the wavelength range of 380–760 nm with an error not worse than ΔТ ≤ 2%.


  • STUDY OF DE-ICING LIQUID WITH AN OPTOELECTRONIC REFRACTOMETER

    by Y. Y. Mikhalchevsky, E. E. Maiorov, A. V. Arefiev, M. V. Khokhlova, Saint Petersburg Military Space Academy Named After A.F. Mozhaisky, S. V. Udachina

    This work highlights the development of optoelectronic refractometer to study anti-icing liquids. Determining the composition authenticity and the flow rate of these liquids has always been a relevant task for the airport maintenance units, engaged in the processing of the aircraft body. The paper presents the objects of research: aqueous solutions of ethylene glycol and propylene glycol, which make up 95% of the composition of liquids of TYPE I, TYPE II, TYPE IV. The structural diagram and appearance of an optoelectronic refractometer are given. The results of measurements of the temperature dependences of the refractive index n(t) for solutions of ethylene glycol and propylene glycol in the temperature range from 12 °C to 100 °C and for concentrations from 0% to 100% are obtained. The spectra of ultraviolet optical transmission in ethylene glycol and propylene glycol of high purity in the wavelength range λ 210–320 nm with an error not worse than T = 0.5% are studied. The technical characteristics of an optoelectronic refractometer are given.