A. V. Arefiev
A. V. Arefiev has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- A. V. Dagaev2 shared publications
- E. E. Maiorov
Saint-Petersburg State University of Aerospace Instrumentation
2 shared publications - R. B. Guliyev2 shared publications
- I. S. Tayurskaya
St. Petersburg University of Management Technologies and Economics
1 shared publication - O. V. Gromov
Санкт-Петербургский политехнический университет Петра Великого
1 shared publication - V. B. Kotskovich1 shared publication
Latest Publications
- 30 May 2022
- Published by Institute for Analytical Instrumentation of the Russian Academy of Sciences in NAUCHNOE PRIBOROSTROENIE
- Vol. 32 (2) , 65-74
INVESTIGATION OF OPTICAL FLAT SURFACES OF BEAM-SPLITTING PLATES BY MEANS OF COHERENT OPTICS
The article presents an experimental setup for measuring the geometric parameters of optical surfaces of details. The relevance of the work is shown since obtaining high-precision and reliable information about the geometric parameters of surfaces has always been an important task of metrology. The paper highlights the optical layout of the interferometer, as well as the technical and operational characteristics of the experimental setup. The objects and method of research are determined. Interferograms were obtained from the surfaces of beam splitters from various manufacturers. The images of interference fields were analyzed, and the main parameters of wave fronts were revealed. The optical surfaces were controlled by an experimental setup with an accuracy of not worse than 0.05 λ. The reflective coatings of beam splitters were studied, and the dependences of the reflection coefficient on the x and y coordinates were obtained. Comparative analysis revealed the preferable option for modern automated interferometers.
- 30 May 2022
- Published by Institute for Analytical Instrumentation of the Russian Academy of Sciences in NAUCHNOE PRIBOROSTROENIE
- Vol. 32 (2) , 65-74
INVESTIGATION OF OPTICAL FLAT SURFACES OF BEAM-SPLITTING PLATES BY MEANS OF COHERENT OPTICS
The article presents an experimental setup for measuring the geometric parameters of optical surfaces of details. The relevance of the work is shown since obtaining high-precision and reliable information about the geometric parameters of surfaces has always been an important task of metrology. The paper highlights the optical layout of the interferometer, as well as the technical and operational characteristics of the experimental setup. The objects and method of research are determined. Interferograms were obtained from the surfaces of beam splitters from various manufacturers. The images of interference fields were analyzed, and the main parameters of wave fronts were revealed. The optical surfaces were controlled by an experimental setup with an accuracy of not worse than 0.05 λ. The reflective coatings of beam splitters were studied, and the dependences of the reflection coefficient on the x and y coordinates were obtained. Comparative analysis revealed the preferable option for modern automated interferometers.
- 30 May 2022
- Published by Institute for Analytical Instrumentation of the Russian Academy of Sciences in NAUCHNOE PRIBOROSTROENIE
- Vol. 32 (2) , 75-83
REFRACTOMETRIC MEANS OF CONTROL OF AQUEOUS SOLUTIONS OF TETRACHLOROETHYLENE
The paper a refractometric device (URL-1) for measuring the concentration dependence of the refractive index in aqueous solutions of tetrachloroethylene is considered. The presented study is relevant and promising, since the identification of optical parameters in these media is important for chemical industries. The article the appearance of a laboratory refractometric installation, as well as technical and operational characteristics of refractometers used in measurements are presented. The results of measurements of the concentration dependence of the refractive index of the studied substances were obtained experimentally, which were compared with reference values from the scientific literature. The data of experimental measurements and reference values are compared with the results obtained on the K-Patents OY PR-03-M refractometer. The error of the experiment did not exceed k ≤ 0.4%.
- 30 May 2022
- Published by Institute for Analytical Instrumentation of the Russian Academy of Sciences in NAUCHNOE PRIBOROSTROENIE
- Vol. 32 (2) , 75-83
REFRACTOMETRIC MEANS OF CONTROL OF AQUEOUS SOLUTIONS OF TETRACHLOROETHYLENE
The paper a refractometric device (URL-1) for measuring the concentration dependence of the refractive index in aqueous solutions of tetrachloroethylene is considered. The presented study is relevant and promising, since the identification of optical parameters in these media is important for chemical industries. The article the appearance of a laboratory refractometric installation, as well as technical and operational characteristics of refractometers used in measurements are presented. The results of measurements of the concentration dependence of the refractive index of the studied substances were obtained experimentally, which were compared with reference values from the scientific literature. The data of experimental measurements and reference values are compared with the results obtained on the K-Patents OY PR-03-M refractometer. The error of the experiment did not exceed k ≤ 0.4%.