Xiangbo Bu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Xiangbo Bu has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
Zigang Xu
4 shared publications- Francisco López Almansa
Universitat Politècnica de Catalunya, Barcelona, Spain, Spain
3 shared publications - Albert Albareda-Valls
Department of Architectural Technology, Universitat Politècnica de Catalunya-BarcelonaTech (UPC), 08028 Barcelona, Spain
2 shared publications Alberto Ledesma
2 shared publications- Chao Luo
School of Civil Engineering, Shijiazhuang Tiedao University, Shijiazhuang, China
2 shared publications Francisco López-Almansa
2 shared publications
Latest Publications
- 14 September 2026
- Published by Seismological Society of America (SSA) in Bulletin of the Seismological Society of America
A Method for Consistent Decomposition of Regional Near-Fault Ground Motions into Dynamic and Fault-Slip-Induced Components
Reliable separation of dynamic and fault-slip-induced components in near-fault ground motions remains a critical challenge for regional seismic analysis because existing approaches have been primarily developed for individual records and lack spatial consistency. This study proposes a unified frequency-based framework in which a single optimal cutoff frequency is determined through a global objective function evaluated over all spatial locations. The results indicate that an optimal cutoff frequency of 0.29 Hz provides the best overall decomposition, corresponding to a mean objective function value of 0.208 and a standard deviation of 0.078, reflecting both good decomposition performance and limited spatial variability. The proposed framework enables consistent separation of acceleration-dominated dynamic motion and displacement-dominated fault-slip-induced deformation across the regional ground-motion field. Based on the decomposed components, spatial distributions of peak ground-motion parameters and response spectra are analyzed to quantify their respective contributions. The results show that dynamic components control acceleration-related responses, whereas fault-slip-induced components dominate permanent displacement and long-period spectral behavior. Directional spectral analysis further reveals a clear difference between the fault-parallel and fault-normal directions. In the fault-parallel direction, the fault-slip-induced component becomes dominant at long periods, leading to a pronounced transition from dynamic to fault-slip-controlled response. In contrast, in the fault-normal direction, the dynamic component remains significant even at long periods, and the contribution of the fault-slip-induced component is comparatively limited. These results indicate that the influence of fault slip on seismic response is strongly direction dependent, with a much greater impact in the fault-parallel direction than in the fault-normal direction. These findings demonstrate that a unified cutoff frequency can effectively ensure consistent decomposition across a regional ground-motion field while revealing the distinct and direction-dependent roles of dynamic motion and fault-slip-induced deformation in near-fault seismic response.
- 14 September 2026
- Published by Seismological Society of America (SSA) in Bulletin of the Seismological Society of America
A Method for Consistent Decomposition of Regional Near-Fault Ground Motions into Dynamic and Fault-Slip-Induced Components
Reliable separation of dynamic and fault-slip-induced components in near-fault ground motions remains a critical challenge for regional seismic analysis because existing approaches have been primarily developed for individual records and lack spatial consistency. This study proposes a unified frequency-based framework in which a single optimal cutoff frequency is determined through a global objective function evaluated over all spatial locations. The results indicate that an optimal cutoff frequency of 0.29 Hz provides the best overall decomposition, corresponding to a mean objective function value of 0.208 and a standard deviation of 0.078, reflecting both good decomposition performance and limited spatial variability. The proposed framework enables consistent separation of acceleration-dominated dynamic motion and displacement-dominated fault-slip-induced deformation across the regional ground-motion field. Based on the decomposed components, spatial distributions of peak ground-motion parameters and response spectra are analyzed to quantify their respective contributions. The results show that dynamic components control acceleration-related responses, whereas fault-slip-induced components dominate permanent displacement and long-period spectral behavior. Directional spectral analysis further reveals a clear difference between the fault-parallel and fault-normal directions. In the fault-parallel direction, the fault-slip-induced component becomes dominant at long periods, leading to a pronounced transition from dynamic to fault-slip-controlled response. In contrast, in the fault-normal direction, the dynamic component remains significant even at long periods, and the contribution of the fault-slip-induced component is comparatively limited. These results indicate that the influence of fault slip on seismic response is strongly direction dependent, with a much greater impact in the fault-parallel direction than in the fault-normal direction. These findings demonstrate that a unified cutoff frequency can effectively ensure consistent decomposition across a regional ground-motion field while revealing the distinct and direction-dependent roles of dynamic motion and fault-slip-induced deformation in near-fault seismic response.
- Open Access
- 31 August 2026
- Published by Elsevier in Case Studies in Construction Materials
- Vol. 25
Preparation technology and mechanical properties of early-strength high-performance sleeve grout
- 31 August 2026
- Published by Elsevier in Case Studies in Construction Materials
- Vol. 25
Open AccessPreparation technology and mechanical properties of early-strength high-performance sleeve grout
- 24 June 2026
- Published by Elsevier in Tunnelling and Underground Space Technology
- Vol. 176
Evaluation of ground-motion intensity measures for seismic response of fault-crossing tunnels
- 24 June 2026
- Published by Elsevier in Tunnelling and Underground Space Technology
- Vol. 176
Evaluation of ground-motion intensity measures for seismic response of fault-crossing tunnels
- Open Access
- 10 May 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (10) , 4077
Research on Seismic Performance of a Two-Story, Two-Span Underground Subway Station with Split Columns Based on the Quasi-Static Method
The behavior of center columns in shallow-buried underground subway station structures resembles that of high-rise buildings. In both cases, these columns experience significant vertical loads during earthquake events and are susceptible to brittle failure due to inadequate deformation capacity. In this study, the design concept of split columns, commonly employed in high-rise structures, is adapted for application in a two-story, two-span subway station. Initially, a comparative analysis was conducted using quasi-static pushover analysis to assess the horizontal deformation characteristics of traditional and split columns under high axial loads. Subsequently, a comprehensive quasi-static pushover analysis model encompassing the soil–structure interaction was formulated. This model was employed to investigate differences in seismic performance between traditional and innovative underground structures, considering internal forces, deformation capacity, and plastic damage of crucial elements. The analysis results demonstrate that the incorporation of split columns in a two-story, two-span subway station enhances the overall seismic performance of the structure. This enhancement arises from the fact that split columns mitigate excessive shear forces while effectively utilizing their vertical support and horizontal deformation capacities.
- 10 May 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (10) , 4077
Open AccessResearch on Seismic Performance of a Two-Story, Two-Span Underground Subway Station with Split Columns Based on the Quasi-Static Method
The behavior of center columns in shallow-buried underground subway station structures resembles that of high-rise buildings. In both cases, these columns experience significant vertical loads during earthquake events and are susceptible to brittle failure due to inadequate deformation capacity. In this study, the design concept of split columns, commonly employed in high-rise structures, is adapted for application in a two-story, two-span subway station. Initially, a comparative analysis was conducted using quasi-static pushover analysis to assess the horizontal deformation characteristics of traditional and split columns under high axial loads. Subsequently, a comprehensive quasi-static pushover analysis model encompassing the soil–structure interaction was formulated. This model was employed to investigate differences in seismic performance between traditional and innovative underground structures, considering internal forces, deformation capacity, and plastic damage of crucial elements. The analysis results demonstrate that the incorporation of split columns in a two-story, two-span subway station enhances the overall seismic performance of the structure. This enhancement arises from the fact that split columns mitigate excessive shear forces while effectively utilizing their vertical support and horizontal deformation capacities.
- Open Access
Numerical Analysis of the Axial-Flexural Behavior of CFST Columns with Active Transverse Prestressing
This paper presents a numerical study on the vertical (axial) and lateral (flexure) behavior of CFST (Concrete-Filled Steel Tube) columns with active hoop prestress achieved by bolting together two steel half-tubes. Twelve prototype CFST column specimens differing in the prestressing force (three levels) and in the gravity loading ratio (four levels) are analyzed; they are selected to represent typical ground columns of mid-rise buildings. Their structural behavior is simulated with a nonlinear model implemented in Abaqus; concrete and steel behavior are described with a damage-plasticity and a plasticity model, respectively. The concrete-steel interaction is represented by a hard (compression-only) surface-to-surface contact model. The calculations involve three consecutive loading steps: (i) transverse prestress, (ii) axial force, and (iii) lateral loading (shear force and bending moment). The calculation results show that the axial-flexural capacity of the prototype CFST columns is adequate. However, the hoop prestress benefit on axial compressive performance is not outstanding because the tube transverse Poisson expansion impairs the concrete confinement. The benefit in the flexural performance is smaller, due to the lack of sectional lateral expansion during bending. Preliminary studies on mid-rise buildings equipped with the prototype CFST columns show that their gravity and wind capacities are largely enough; conversely, their seismic strength is sufficient only for moderate earthquakes.
Open AccessNumerical Analysis of the Axial-Flexural Behavior of CFST Columns with Active Transverse Prestressing
This paper presents a numerical study on the vertical (axial) and lateral (flexure) behavior of CFST (Concrete-Filled Steel Tube) columns with active hoop prestress achieved by bolting together two steel half-tubes. Twelve prototype CFST column specimens differing in the prestressing force (three levels) and in the gravity loading ratio (four levels) are analyzed; they are selected to represent typical ground columns of mid-rise buildings. Their structural behavior is simulated with a nonlinear model implemented in Abaqus; concrete and steel behavior are described with a damage-plasticity and a plasticity model, respectively. The concrete-steel interaction is represented by a hard (compression-only) surface-to-surface contact model. The calculations involve three consecutive loading steps: (i) transverse prestress, (ii) axial force, and (iii) lateral loading (shear force and bending moment). The calculation results show that the axial-flexural capacity of the prototype CFST columns is adequate. However, the hoop prestress benefit on axial compressive performance is not outstanding because the tube transverse Poisson expansion impairs the concrete confinement. The benefit in the flexural performance is smaller, due to the lack of sectional lateral expansion during bending. Preliminary studies on mid-rise buildings equipped with the prototype CFST columns show that their gravity and wind capacities are largely enough; conversely, their seismic strength is sufficient only for moderate earthquakes.
- Open Access
- 16 August 2023
- Published by MDPI AG in Preprints.org
Numerical Analysis of the Axial-Flexural Behavior of CFST Columns with Active Transverse Prestressing
This paper presents a numerical study on the vertical (axial) and lateral (flexure) behavior of CFST (Concrete-Filled Steel Tube) columns with active hoop prestress; this transverse prestressing effect is achieved by bolting together two steel half-tubes. This study refers to new construction only (i.e., no retrofit). 12 prototype CFST column specimens (segments) are analyzed. These specimens differ in the prestressing force (3 levels) and in the gravity loading ratio (4 levels); they are selected to represent typical ground columns of mid-rise buildings. The structural behavior of these column specimens is simulated with a nonlinear model implemented in Abaqus; the concrete and steel behavior are described with a damage-plasticity and a plasticity model, respectively. Finally, the interface concrete-steel interaction is represented by a hard (compression-only) surface-to-surface contact model. The calculations involve three consecutive loading steps: (i) transverse prestress, (ii) axial force, and (iii) lateral loading (shear force and bending moment). The structural behavior of the CFST columns is deeply examined and discussed; the results show that their axial-flexural capacity is adequate. Noticeably, it is concluded that the overall benefits of prestressing the columns are only modest. Preliminary studies on the aforementioned mid-rise buildings equipped with the CFST columns show that their gravity and wind capacities are largely enough; conversely, their seismic capacity is sufficient for moderate seismic ground motions only.
- 16 August 2023
- Published by MDPI AG in Preprints.org
Open AccessNumerical Analysis of the Axial-Flexural Behavior of CFST Columns with Active Transverse Prestressing
This paper presents a numerical study on the vertical (axial) and lateral (flexure) behavior of CFST (Concrete-Filled Steel Tube) columns with active hoop prestress; this transverse prestressing effect is achieved by bolting together two steel half-tubes. This study refers to new construction only (i.e., no retrofit). 12 prototype CFST column specimens (segments) are analyzed. These specimens differ in the prestressing force (3 levels) and in the gravity loading ratio (4 levels); they are selected to represent typical ground columns of mid-rise buildings. The structural behavior of these column specimens is simulated with a nonlinear model implemented in Abaqus; the concrete and steel behavior are described with a damage-plasticity and a plasticity model, respectively. Finally, the interface concrete-steel interaction is represented by a hard (compression-only) surface-to-surface contact model. The calculations involve three consecutive loading steps: (i) transverse prestress, (ii) axial force, and (iii) lateral loading (shear force and bending moment). The structural behavior of the CFST columns is deeply examined and discussed; the results show that their axial-flexural capacity is adequate. Noticeably, it is concluded that the overall benefits of prestressing the columns are only modest. Preliminary studies on the aforementioned mid-rise buildings equipped with the CFST columns show that their gravity and wind capacities are largely enough; conversely, their seismic capacity is sufficient for moderate seismic ground motions only.
- Open Access
- 10 June 2023
- Published by Elsevier in Engineering Structures
- Vol. 291
Low lateral stiffness underground structures for improved seismic performance. Application to the Kobe Daikai station
- 10 June 2023
- Published by Elsevier in Engineering Structures
- Vol. 291
Open AccessLow lateral stiffness underground structures for improved seismic performance. Application to the Kobe Daikai station