Sebastian Nilsson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Sebastian Nilsson has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
Andreas Ehn
Division of Combustion Physics, Department of Physics, Lund University, Lund, Sweden
5 shared publicationsMarcus Aldén
4 shared publications- Mattias Richter
Division of Combustion Physics, Lund University, Sweden
4 shared publications Elias Kristensson
Division of Combustion Physics, Department of Physics, Lund University, Lund, Sweden
3 shared publications- Henrik Feuk
Combustion Physics, Lund University, Lund, Sweden
3 shared publications - Andreas Ehn
Lund University
2 shared publications
Latest Publications
- Open Access
- 13 January 2026
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 59 (2) , 025214
Correlation of temperature fields and OH radical distributions in a gliding arc plasma
Gliding arc discharges offer a promising pathway for sustainable, electrified chemical conversion, but their complex, transient nature presents significant diagnostic challenges. Understanding the interplay between key reactive species, such as the hydroxyl (OH) radical, and the underlying temperature field is crucial for optimizing plasma chemistry, yet remains difficult to measure experimentally. This work addresses this challenge through simultaneous, single-shot structured laser illumination Rayleigh thermometry (SLIRT) and OH planar laser-induced fluorescence, quantitatively mapping both temperature and OH distributions within an atmospheric pressure air gliding arc. A key aspect of this work is the accurate determination of gas temperature via SLIRT, which requires accounting for the strong temperature dependence of the gas composition and the effective Rayleigh scattering cross-section. This correction was achieved using an iterative procedure based on local chemical equilibrium calculations, significantly refining the temperature measurement from an apparent peak near 4000 K to a corrected true temperature. The results reveal a hot, OH-depleted core with gas temperatures reaching approximately 3100 K, surrounded by a ring-like OH distribution peaking at 1500 K. This distinct spatial separation is explained by a combination of thermal and non-thermal effects: the hot core acts as a source for OH via H 2 O dissociation, while efficient non-thermal electron-impact reactions within the plasma channel create a localized sink with atoms and excited species. This integrated diagnostic approach, incorporating the rigorous temperature correction, provides unambiguous, spatially correlated data essential for validating kinetic models and advancing the understanding of non-equilibrium plasma chemistry.
- 13 January 2026
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 59 (2) , 025214
Open AccessCorrelation of temperature fields and OH radical distributions in a gliding arc plasma
Gliding arc discharges offer a promising pathway for sustainable, electrified chemical conversion, but their complex, transient nature presents significant diagnostic challenges. Understanding the interplay between key reactive species, such as the hydroxyl (OH) radical, and the underlying temperature field is crucial for optimizing plasma chemistry, yet remains difficult to measure experimentally. This work addresses this challenge through simultaneous, single-shot structured laser illumination Rayleigh thermometry (SLIRT) and OH planar laser-induced fluorescence, quantitatively mapping both temperature and OH distributions within an atmospheric pressure air gliding arc. A key aspect of this work is the accurate determination of gas temperature via SLIRT, which requires accounting for the strong temperature dependence of the gas composition and the effective Rayleigh scattering cross-section. This correction was achieved using an iterative procedure based on local chemical equilibrium calculations, significantly refining the temperature measurement from an apparent peak near 4000 K to a corrected true temperature. The results reveal a hot, OH-depleted core with gas temperatures reaching approximately 3100 K, surrounded by a ring-like OH distribution peaking at 1500 K. This distinct spatial separation is explained by a combination of thermal and non-thermal effects: the hot core acts as a source for OH via H 2 O dissociation, while efficient non-thermal electron-impact reactions within the plasma channel create a localized sink with atoms and excited species. This integrated diagnostic approach, incorporating the rigorous temperature correction, provides unambiguous, spatially correlated data essential for validating kinetic models and advancing the understanding of non-equilibrium plasma chemistry.
- Open Access
- 6 January 2026
- Published by Elsevier in Optics and Lasers in Engineering
- Vol. 200
Quantitative raman thermometry and N2+ detection in a non-transferred plasma torch
- 6 January 2026
- Published by Elsevier in Optics and Lasers in Engineering
- Vol. 200
Open AccessQuantitative raman thermometry and N2+ detection in a non-transferred plasma torch
- 15 October 2025
- Published by Elsevier in Combustion and Flame
- Vol. 282
CH3 photo-fragmentation laser-induced fluorescence for turbulent flame diagnosis
- 15 October 2025
- Published by Elsevier in Combustion and Flame
- Vol. 282
CH3 photo-fragmentation laser-induced fluorescence for turbulent flame diagnosis
- Open Access
Observation of thickness-independent ultrafast relaxation times in MPCVD few-layer graphene
- Open Access
- 8 July 2024
- Published by Optica Publishing Group in Optics Express
- Vol. 32 (15) , 26492-26499
Photofragmentation laser-induced fluorescence imaging of CH3 by structured illumination in a plasma discharge
Methyl is crucial in plasma-assisted hydrocarbon chemistry, making precise in situ imaging essential for understanding various plasma applications. Its importance in methane chemistry arises from its role as a primary byproduct during the initial phase of methane dehydrogenation. Detecting the CH3 radical is challenging due to its high reactivity and the prevalence of strongly pre-dissociative electronically excited states. To address this, photofragmentation planar laser-induced fluorescence (PF-LIF) techniques have been developed. These involve laser-induced photodissociation of the CH3 radical into CH fragments, which are then probed using another laser. This method allows for both temporally and spatially resolved measurements. However, quantifying the signal from photofragmented species is complicated by the overlap with naturally occurring CH fragments. We employ PF-LIF with structured illumination to distinguish photofragmented species from naturally occurring ones using a frequency-sensitive lock-in technique. This methodology is demonstrated in an atmospheric pressure dielectric barrier discharge (DBD) containing argon and methane, enabling spatially and temporally resolved data acquisition of the CH3 radical. This approach facilitates interference-free PF-LIF measurements of methyl in various applications.
- 8 July 2024
- Published by Optica Publishing Group in Optics Express
- Vol. 32 (15) , 26492-26499
Open AccessPhotofragmentation laser-induced fluorescence imaging of CH3 by structured illumination in a plasma discharge
Methyl is crucial in plasma-assisted hydrocarbon chemistry, making precise in situ imaging essential for understanding various plasma applications. Its importance in methane chemistry arises from its role as a primary byproduct during the initial phase of methane dehydrogenation. Detecting the CH3 radical is challenging due to its high reactivity and the prevalence of strongly pre-dissociative electronically excited states. To address this, photofragmentation planar laser-induced fluorescence (PF-LIF) techniques have been developed. These involve laser-induced photodissociation of the CH3 radical into CH fragments, which are then probed using another laser. This method allows for both temporally and spatially resolved measurements. However, quantifying the signal from photofragmented species is complicated by the overlap with naturally occurring CH fragments. We employ PF-LIF with structured illumination to distinguish photofragmented species from naturally occurring ones using a frequency-sensitive lock-in technique. This methodology is demonstrated in an atmospheric pressure dielectric barrier discharge (DBD) containing argon and methane, enabling spatially and temporally resolved data acquisition of the CH3 radical. This approach facilitates interference-free PF-LIF measurements of methyl in various applications.
- Open Access
- 21 March 2024
- Published by Elsevier in Combustion and Flame
- Vol. 263
Application of emission spectroscopy in plasma-assisted NH3/air combustion using nanosecond pulsed discharge
- 21 March 2024
- Published by Elsevier in Combustion and Flame
- Vol. 263
Open AccessApplication of emission spectroscopy in plasma-assisted NH3/air combustion using nanosecond pulsed discharge
- Open Access
- 14 August 2023
- Published by AIP Publishing in Applied Physics Letters
- Vol. 123 (7)
3D-tomographic reconstruction of gliding arc plasma
This study presents three-dimensional (3D) emission tomography on gliding arc discharge for volumetric measurements of plasma luminosity fields. The 3D tomography of the plasma luminosity field enables quantification and characterization of 3D plasma features, which are not easily accessible in two-dimensional measurements. Simultaneous projections of the plasma discharge were imaged using multiple CMOS cameras, and an in-house developed tomographic method was used for the 3D reconstruction of the luminosity fields. Results show good field reconstruction quality and expected gliding arc topologies. Comparisons between arc 3D length and 2D projected length displayed that 2D measurements underestimated length by around 15% at the highest tested flow case. The mean 3D length initially increased with increasing air flow, while later decreasing at even higher flows. The standard deviation of 3D length increased with increasing flow. Arc curvature and overlap were generally seen to increase with higher flows in contrast to arc volume that was seen to decrease with increasing flow rates. This study aims to facilitate instantaneous 3D tomographic measurements of plasma luminosity fields to provide a detailed quantification of 3D characteristics and correlations of typical plasma features, thereby providing paths to remove line-of-sight effects and compensate for loss of information that may occur during two-dimensional measurements. The presented technique is applicable not only to gliding arcs but also to various other plasma systems.
- 14 August 2023
- Published by AIP Publishing in Applied Physics Letters
- Vol. 123 (7)
Open Access3D-tomographic reconstruction of gliding arc plasma
This study presents three-dimensional (3D) emission tomography on gliding arc discharge for volumetric measurements of plasma luminosity fields. The 3D tomography of the plasma luminosity field enables quantification and characterization of 3D plasma features, which are not easily accessible in two-dimensional measurements. Simultaneous projections of the plasma discharge were imaged using multiple CMOS cameras, and an in-house developed tomographic method was used for the 3D reconstruction of the luminosity fields. Results show good field reconstruction quality and expected gliding arc topologies. Comparisons between arc 3D length and 2D projected length displayed that 2D measurements underestimated length by around 15% at the highest tested flow case. The mean 3D length initially increased with increasing air flow, while later decreasing at even higher flows. The standard deviation of 3D length increased with increasing flow. Arc curvature and overlap were generally seen to increase with higher flows in contrast to arc volume that was seen to decrease with increasing flow rates. This study aims to facilitate instantaneous 3D tomographic measurements of plasma luminosity fields to provide a detailed quantification of 3D characteristics and correlations of typical plasma features, thereby providing paths to remove line-of-sight effects and compensate for loss of information that may occur during two-dimensional measurements. The presented technique is applicable not only to gliding arcs but also to various other plasma systems.
- Open Access
- 17 July 2023
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 34 (10) , 104003
Fiber-coupled phosphor thermometry for wall temperature measurements in a full-scale hydrogen gas turbine combustor
Online wall temperatures were measured with fiber-coupled phosphor thermometry in a full-scale gas turbine combustor. The combustor was operated with natural gas and up to 100 vol% hydrogen at engine-relevant conditions. Two phosphors were tested for this application, namely YAG:Dy and YAG:Tm;Li. Although YAG:Tm;Li seemed to be the most promising phosphor for this application, it turned out to be incompatible with the used setup due to a strong interfering signal generated by the laser in the used fiber setup. A strategy to compensate for interferences from flame emissions during natural gas operation was developed. With this strategy it was possible to obtain single-shot temperature measurements at 15 Hz and a precision of 2–7 K for a 1 s average.
- 17 July 2023
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 34 (10) , 104003
Open AccessFiber-coupled phosphor thermometry for wall temperature measurements in a full-scale hydrogen gas turbine combustor
Online wall temperatures were measured with fiber-coupled phosphor thermometry in a full-scale gas turbine combustor. The combustor was operated with natural gas and up to 100 vol% hydrogen at engine-relevant conditions. Two phosphors were tested for this application, namely YAG:Dy and YAG:Tm;Li. Although YAG:Tm;Li seemed to be the most promising phosphor for this application, it turned out to be incompatible with the used setup due to a strong interfering signal generated by the laser in the used fiber setup. A strategy to compensate for interferences from flame emissions during natural gas operation was developed. With this strategy it was possible to obtain single-shot temperature measurements at 15 Hz and a precision of 2–7 K for a 1 s average.
- Open Access
- 1 March 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (3) , 034901
Temperature resolved decay time components of Mg4FGeO6:Mn using the maximum entropy method
A thermographic phosphor’s decay time distribution over its temperature-sensitive range was retrieved with the Maximum Entropy Method (MEM). A decay time distribution consists of a range of decay times, each with an associated weighting for the decay time component’s prevalence in the analyzed decay curve. With the MEM, significant decay time contributions of a decay curve have high weighting and are therefore found as peaks in the decay time distribution, where the width and peak value are correlated with the relative weight of the decay time components. These peaks in the decay time distribution give increased insight into a phosphor’s lifetime behavior, which often cannot accurately be represented by a single or even two decay time components. The changes in the location of peaks in the decay time distribution with temperature can be used for thermometry, and this method has the benefit of being less sensitive to the multi-exponentiality of phosphor decay than mono-exponential decay time fitting. The method also resolves the underlying decay components with no assumptions of the number of significant decay time components. Initially, when the decay time distribution of Mg4FGeO6:Mn was captured, the collected decay included decaying luminescence from the alumina oxide tube in the tube furnace. Therefore, a second calibration was performed where the luminescence from the alumina oxide tube was minimized. These two calibration datasets were used to demonstrate that the MEM could characterize decays from two separate sources simultaneously.
- 1 March 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (3) , 034901
Open AccessTemperature resolved decay time components of Mg4FGeO6:Mn using the maximum entropy method
A thermographic phosphor’s decay time distribution over its temperature-sensitive range was retrieved with the Maximum Entropy Method (MEM). A decay time distribution consists of a range of decay times, each with an associated weighting for the decay time component’s prevalence in the analyzed decay curve. With the MEM, significant decay time contributions of a decay curve have high weighting and are therefore found as peaks in the decay time distribution, where the width and peak value are correlated with the relative weight of the decay time components. These peaks in the decay time distribution give increased insight into a phosphor’s lifetime behavior, which often cannot accurately be represented by a single or even two decay time components. The changes in the location of peaks in the decay time distribution with temperature can be used for thermometry, and this method has the benefit of being less sensitive to the multi-exponentiality of phosphor decay than mono-exponential decay time fitting. The method also resolves the underlying decay components with no assumptions of the number of significant decay time components. Initially, when the decay time distribution of Mg4FGeO6:Mn was captured, the collected decay included decaying luminescence from the alumina oxide tube in the tube furnace. Therefore, a second calibration was performed where the luminescence from the alumina oxide tube was minimized. These two calibration datasets were used to demonstrate that the MEM could characterize decays from two separate sources simultaneously.
- Open Access
- 21 February 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-9
Fluorescence lifetime imaging through scattering media
Fluorescence lifetime determination has proven to be useful, e.g. identification of molecules, quantitative estimation of species concentration and determination of temperatures. Lifetime determination of exponentially decaying signals is challenging if signals of different decay rates are being mixed, resulting in erroneous results. Such issues occur when the contrast of the measurement object is low, which can be limiting in applied measurements due to spurious light scattering. A solution is presented here where structured illumination is used to enhance image contrast in fluorescence lifetime wide-field imaging. Lifetime imaging determination was carried out using Dual Imaging Modeling Evaluation (DIME), and spatial lock-in analysis was used for removing spurious scattered signal to enable fluorescence lifetime imaging through scattering media.
- 21 February 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-9
Open AccessFluorescence lifetime imaging through scattering media
Fluorescence lifetime determination has proven to be useful, e.g. identification of molecules, quantitative estimation of species concentration and determination of temperatures. Lifetime determination of exponentially decaying signals is challenging if signals of different decay rates are being mixed, resulting in erroneous results. Such issues occur when the contrast of the measurement object is low, which can be limiting in applied measurements due to spurious light scattering. A solution is presented here where structured illumination is used to enhance image contrast in fluorescence lifetime wide-field imaging. Lifetime imaging determination was carried out using Dual Imaging Modeling Evaluation (DIME), and spatial lock-in analysis was used for removing spurious scattered signal to enable fluorescence lifetime imaging through scattering media.