Henrik Feuk
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Henrik Feuk has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
Mattias Richter
Combustion Physics, Lund University, Lund, Sweden
5 shared publications- Mattias Richter
Division of Combustion Physics, Lund University, Sweden
3 shared publications Sebastian Nilsson
Combustion Physics, Lund University, Lund, Sweden
3 shared publications- Sebastian Nilsson
Division of Combustion Physics, Department of Physics, Lund University, Lund, Sweden
3 shared publications Marcus Aldén
Combustion Physics, Lund University , Professorsgatan 1, SE-223 63 Lund, Sweden
2 shared publicationsAlexandre F. Carvalho
1 shared publication
Latest Publications
- 3 July 2025
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 36 (7) , 075203
Minimizing the angle of incidence errors in intensity ratio phosphor thermometry
Intensity ratio–based phosphor thermometry is a promising technique for instantaneous temperature measurement of fast-moving objects. However, its accuracy is limited by the blueshift effects of interference filters induced by angle of incidence (AOI) variations. This is especially problematic for phosphors with significant temperature-dependent emission band shifts. To address this issue, we propose the following two-step method. First, a simulation procedure is developed to evaluate measurement errors induced by AOI variations under different filter sets using the BaMgAl10O17:Eu2+ (BAM:Eu) phosphor. Simulation results are carefully analyzed, and a filter set is selected that generates low AOI errors and high temperature sensitivity. Second, an experimental temperature–AOI calibration method is developed by fitting the intensity ratio distribution under different AOIs and temperatures using a bivariate quadratic function. Finally, the intensity ratio–based phosphor thermometry method with the selected filter set and the temperature–AOI calibration is validated via surface temperature measurements on a heated disk. AOI-induced errors up to 25 K and 12 K are effectively removed under stationary and rotating conditions, respectively.
- 3 July 2025
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 36 (7) , 075203
Minimizing the angle of incidence errors in intensity ratio phosphor thermometry
Intensity ratio–based phosphor thermometry is a promising technique for instantaneous temperature measurement of fast-moving objects. However, its accuracy is limited by the blueshift effects of interference filters induced by angle of incidence (AOI) variations. This is especially problematic for phosphors with significant temperature-dependent emission band shifts. To address this issue, we propose the following two-step method. First, a simulation procedure is developed to evaluate measurement errors induced by AOI variations under different filter sets using the BaMgAl10O17:Eu2+ (BAM:Eu) phosphor. Simulation results are carefully analyzed, and a filter set is selected that generates low AOI errors and high temperature sensitivity. Second, an experimental temperature–AOI calibration method is developed by fitting the intensity ratio distribution under different AOIs and temperatures using a bivariate quadratic function. Finally, the intensity ratio–based phosphor thermometry method with the selected filter set and the temperature–AOI calibration is validated via surface temperature measurements on a heated disk. AOI-induced errors up to 25 K and 12 K are effectively removed under stationary and rotating conditions, respectively.
- Open Access
Observation of thickness-independent ultrafast relaxation times in MPCVD few-layer graphene
- Open Access
- 14 March 2023
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 34 (6) , 064003
Upconversion phosphor thermometry for use in thermal barrier coatings
Measuring the temperature below the surface of a thermal barrier coating (TBC) using a thin phosphor layer is challenging primarily due to the absorption and scattering of laser excitation light and phosphor luminescence as they propagate through the coating. One way to increase phosphor luminescence could be to use upconversion phosphor thermometry, which is investigated in the current study. It is attractive because using longer excitation wavelengths reduces the absorption and scattering in TBCs as 8% wt. yttria-stabilize zirconia (8YSZ) generally has lower scattering and absorption coefficients around 1000 nm than at 532 and 355 nm. Therefore, the viability of upconversion to measure the temperature at the bottom of a TBC was evaluated for the first time and was compared with the more conventional downconversion phosphor thermometry. The current work involved an experimental study of several phosphors with lanthanides doped in the 8YSZ host, which were excited through downconversion by pulsed 355 nm and 532 nm laser light and through upconversion with 965 nm laser light. The YSZ:Er,Yb and YSZ:Ho,Yb phosphors show promise for upconversion phosphor thermometry. The experimentally acquired optical phosphor characteristics were used to simulate laser light and phosphor luminescence propagation in TBCs using Kubelka–Munk theory. This was to evaluate the signal strength with upconversion excitation compared to downconversion excitation. Upconversion excitation resulted greater signal strength from an embedded phosphor layer than 532 nm excitation and much higher than 355 nm excitation. Upconversion lifetime phosphor thermometry also resulted in improved phosphor lifetime temperature sensitivity. Coupled with reduced interference from background luminescence from impurities in TBCs with upconversion, it is a promising method for temperature measurements with the thermographic phosphor embedded in or underneath a TBC.
- 14 March 2023
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 34 (6) , 064003
Open AccessUpconversion phosphor thermometry for use in thermal barrier coatings
Measuring the temperature below the surface of a thermal barrier coating (TBC) using a thin phosphor layer is challenging primarily due to the absorption and scattering of laser excitation light and phosphor luminescence as they propagate through the coating. One way to increase phosphor luminescence could be to use upconversion phosphor thermometry, which is investigated in the current study. It is attractive because using longer excitation wavelengths reduces the absorption and scattering in TBCs as 8% wt. yttria-stabilize zirconia (8YSZ) generally has lower scattering and absorption coefficients around 1000 nm than at 532 and 355 nm. Therefore, the viability of upconversion to measure the temperature at the bottom of a TBC was evaluated for the first time and was compared with the more conventional downconversion phosphor thermometry. The current work involved an experimental study of several phosphors with lanthanides doped in the 8YSZ host, which were excited through downconversion by pulsed 355 nm and 532 nm laser light and through upconversion with 965 nm laser light. The YSZ:Er,Yb and YSZ:Ho,Yb phosphors show promise for upconversion phosphor thermometry. The experimentally acquired optical phosphor characteristics were used to simulate laser light and phosphor luminescence propagation in TBCs using Kubelka–Munk theory. This was to evaluate the signal strength with upconversion excitation compared to downconversion excitation. Upconversion excitation resulted greater signal strength from an embedded phosphor layer than 532 nm excitation and much higher than 355 nm excitation. Upconversion lifetime phosphor thermometry also resulted in improved phosphor lifetime temperature sensitivity. Coupled with reduced interference from background luminescence from impurities in TBCs with upconversion, it is a promising method for temperature measurements with the thermographic phosphor embedded in or underneath a TBC.
- Open Access
- 1 March 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (3) , 034901
Temperature resolved decay time components of Mg4FGeO6:Mn using the maximum entropy method
A thermographic phosphor’s decay time distribution over its temperature-sensitive range was retrieved with the Maximum Entropy Method (MEM). A decay time distribution consists of a range of decay times, each with an associated weighting for the decay time component’s prevalence in the analyzed decay curve. With the MEM, significant decay time contributions of a decay curve have high weighting and are therefore found as peaks in the decay time distribution, where the width and peak value are correlated with the relative weight of the decay time components. These peaks in the decay time distribution give increased insight into a phosphor’s lifetime behavior, which often cannot accurately be represented by a single or even two decay time components. The changes in the location of peaks in the decay time distribution with temperature can be used for thermometry, and this method has the benefit of being less sensitive to the multi-exponentiality of phosphor decay than mono-exponential decay time fitting. The method also resolves the underlying decay components with no assumptions of the number of significant decay time components. Initially, when the decay time distribution of Mg4FGeO6:Mn was captured, the collected decay included decaying luminescence from the alumina oxide tube in the tube furnace. Therefore, a second calibration was performed where the luminescence from the alumina oxide tube was minimized. These two calibration datasets were used to demonstrate that the MEM could characterize decays from two separate sources simultaneously.
- 1 March 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (3) , 034901
Open AccessTemperature resolved decay time components of Mg4FGeO6:Mn using the maximum entropy method
A thermographic phosphor’s decay time distribution over its temperature-sensitive range was retrieved with the Maximum Entropy Method (MEM). A decay time distribution consists of a range of decay times, each with an associated weighting for the decay time component’s prevalence in the analyzed decay curve. With the MEM, significant decay time contributions of a decay curve have high weighting and are therefore found as peaks in the decay time distribution, where the width and peak value are correlated with the relative weight of the decay time components. These peaks in the decay time distribution give increased insight into a phosphor’s lifetime behavior, which often cannot accurately be represented by a single or even two decay time components. The changes in the location of peaks in the decay time distribution with temperature can be used for thermometry, and this method has the benefit of being less sensitive to the multi-exponentiality of phosphor decay than mono-exponential decay time fitting. The method also resolves the underlying decay components with no assumptions of the number of significant decay time components. Initially, when the decay time distribution of Mg4FGeO6:Mn was captured, the collected decay included decaying luminescence from the alumina oxide tube in the tube furnace. Therefore, a second calibration was performed where the luminescence from the alumina oxide tube was minimized. These two calibration datasets were used to demonstrate that the MEM could characterize decays from two separate sources simultaneously.
- Open Access
- 1 November 2022
- Published by MDPI AG in International Journal of Turbomachinery, Propulsion and Power
- Vol. 7 (4) , 29
Impact of Methane and Hydrogen-Enriched Methane Pilot Injection on the Surface Temperature of a Scaled-Down Burner Nozzle Measured Using Phosphor Thermometry
The surface temperature of a burner nozzle using three different pilot hardware configurations was measured using lifetime phosphor thermometry with the ZnS:Ag phosphor in a gas turbine model combustor designed to mimic the Siemens DLE (Dry Low Emission) burner. The three pilot hardware configurations included a non-premixed pilot injection setup and two partially premixed pilot injections where one had a relatively higher degree of premixing. For each pilot hardware configuration, the combustor was operated with either methane or hydrogen-enriched methane (H2/CH4: 50/50 in volume %). The local heating from pilot flames was much more significant for hydrogen-enriched methane compared with pure methane due to the pilot flames being in general more closely attached to the pilot nozzles with hydrogen-enriched methane. For the methane fuel, the average surface temperature of the burner nozzle was approximately 40 K higher for the partially premixed pilot injection configuration with a lower degree of mixing as compared to the non-premixed pilot injection configuration. In contrast, with the hydrogen-enriched methane fuel, the differences in surface temperature between the different pilot injection hardware configurations were much smaller due to the close-to-nozzle frame structure.
- 1 November 2022
- Published by MDPI AG in International Journal of Turbomachinery, Propulsion and Power
- Vol. 7 (4) , 29
Open AccessImpact of Methane and Hydrogen-Enriched Methane Pilot Injection on the Surface Temperature of a Scaled-Down Burner Nozzle Measured Using Phosphor Thermometry
The surface temperature of a burner nozzle using three different pilot hardware configurations was measured using lifetime phosphor thermometry with the ZnS:Ag phosphor in a gas turbine model combustor designed to mimic the Siemens DLE (Dry Low Emission) burner. The three pilot hardware configurations included a non-premixed pilot injection setup and two partially premixed pilot injections where one had a relatively higher degree of premixing. For each pilot hardware configuration, the combustor was operated with either methane or hydrogen-enriched methane (H2/CH4: 50/50 in volume %). The local heating from pilot flames was much more significant for hydrogen-enriched methane compared with pure methane due to the pilot flames being in general more closely attached to the pilot nozzles with hydrogen-enriched methane. For the methane fuel, the average surface temperature of the burner nozzle was approximately 40 K higher for the partially premixed pilot injection configuration with a lower degree of mixing as compared to the non-premixed pilot injection configuration. In contrast, with the hydrogen-enriched methane fuel, the differences in surface temperature between the different pilot injection hardware configurations were much smaller due to the close-to-nozzle frame structure.
- Open Access
- 26 September 2022
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 33 (12) , 127003
Automated phosphor thermometry lifetime calibration of multiple phosphors and emission lines to above 1900 K
A method is specified which enables lifetime calibration of multiple phosphors and emission lines at the same time to temperatures above 1900 K. The experimental setup and algorithm used for data collection and experimental equipment control are described. The phosphors were coated on an alumina oxide disc and the reference temperature was measured using three type B thermocouples. The algorithm automates the data collection process such that no input from an operator is required during operation. The potential systematic error in calibration temperature was evaluated and was less than 1% around 1400 K.
- 26 September 2022
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 33 (12) , 127003
Open AccessAutomated phosphor thermometry lifetime calibration of multiple phosphors and emission lines to above 1900 K
A method is specified which enables lifetime calibration of multiple phosphors and emission lines at the same time to temperatures above 1900 K. The experimental setup and algorithm used for data collection and experimental equipment control are described. The phosphors were coated on an alumina oxide disc and the reference temperature was measured using three type B thermocouples. The algorithm automates the data collection process such that no input from an operator is required during operation. The potential systematic error in calibration temperature was evaluated and was less than 1% around 1400 K.
- Open Access
- 4 July 2022
- Published by Elsevier in Journal of Luminescence
- Vol. 250
Laser excitation effects in lifetime-based high-speed phosphor thermometry
- 4 July 2022
- Published by Elsevier in Journal of Luminescence
- Vol. 250
Open AccessLaser excitation effects in lifetime-based high-speed phosphor thermometry
- Open Access
- 1 December 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (12) , 123102
Investigating photomultiplier tube nonlinearities in high-speed phosphor thermometry using light emitting diode simulated decay curves
Photomultiplier tube (PMT) nonlinearities relevant for single shot high-speed lifetime phosphor thermometry were investigated by simulating decay curves with a light emitting diode (LED) at repetition rates between 1 Hz and 10 kHz. The PMT gain, LED decay time, and background radiant flux were also varied to investigate their impact on the measured decay time error. Errors in the measured decay time due to nonlinear PMT performance lead to temperature measurement errors; therefore, having the measured decay time sensitive to only phosphor temperature is highly valuable for more reliable temperature measurements. Photocathode bleaching had a significant impact on the signal level linearity for PMTs with excitation frequency in the kHz regime but had a smaller impact on the decay time error. Space charge effects were most noticeable at high radiant flux levels and high repetition rates. Strong background radiant flux may lead to decay time errors, and a gateable photocathode could be an effective method to reduce decay time errors. The best decay time measurement configuration to maximize precision without sacrificing accuracy is to use PMT gain in the recommended range and the highest radiant flux where the PMT response is still linear. The degree of nonlinearity in the PMT response is partly detector dependent; therefore, the results in this work may differ among detectors; however, the analysis presented in this work provides guidelines for improving the temperature accuracy of kHz lifetime phosphor thermometry measurements.
- 1 December 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (12) , 123102
Open AccessInvestigating photomultiplier tube nonlinearities in high-speed phosphor thermometry using light emitting diode simulated decay curves
Photomultiplier tube (PMT) nonlinearities relevant for single shot high-speed lifetime phosphor thermometry were investigated by simulating decay curves with a light emitting diode (LED) at repetition rates between 1 Hz and 10 kHz. The PMT gain, LED decay time, and background radiant flux were also varied to investigate their impact on the measured decay time error. Errors in the measured decay time due to nonlinear PMT performance lead to temperature measurement errors; therefore, having the measured decay time sensitive to only phosphor temperature is highly valuable for more reliable temperature measurements. Photocathode bleaching had a significant impact on the signal level linearity for PMTs with excitation frequency in the kHz regime but had a smaller impact on the decay time error. Space charge effects were most noticeable at high radiant flux levels and high repetition rates. Strong background radiant flux may lead to decay time errors, and a gateable photocathode could be an effective method to reduce decay time errors. The best decay time measurement configuration to maximize precision without sacrificing accuracy is to use PMT gain in the recommended range and the highest radiant flux where the PMT response is still linear. The degree of nonlinearity in the PMT response is partly detector dependent; therefore, the results in this work may differ among detectors; however, the analysis presented in this work provides guidelines for improving the temperature accuracy of kHz lifetime phosphor thermometry measurements.
- Open Access
- 13 May 2021
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 32 (8) , 084003
Sources of error for single-shot PMT-based phosphor thermometry in harsh conditions
This study investigates photomultiplier tube (PMT) nonlinearities, relevant for lifetime phosphor thermometry, at various decay times to assess and minimize the impact on temperature measurement accuracy. The focus is single-shot measurements performed in harsh environments where phosphor signal attenuation often is a concern. The sensitivity of decay time measurements to changing phosphorescence intensity is therefore investigated. The experimental results show that for the studied phosphors and detectors, shorter decay times between 20 ns and 6 µs, saturation effects in the PMTs decreased the measured decay time with increasing signal attenuation. For longer phosphorescence decay times, in the millisecond regime, nonlinearity effects led to an increase in the measured decay time with increasing signal attenuation. The specific detector nonlinearity response will vary among detectors, but the introduced methodology for detector analysis is a useful resource for assessing and improving accuracy in lifetime phosphor thermometry measurements.
- 13 May 2021
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 32 (8) , 084003
Open AccessSources of error for single-shot PMT-based phosphor thermometry in harsh conditions
This study investigates photomultiplier tube (PMT) nonlinearities, relevant for lifetime phosphor thermometry, at various decay times to assess and minimize the impact on temperature measurement accuracy. The focus is single-shot measurements performed in harsh environments where phosphor signal attenuation often is a concern. The sensitivity of decay time measurements to changing phosphorescence intensity is therefore investigated. The experimental results show that for the studied phosphors and detectors, shorter decay times between 20 ns and 6 µs, saturation effects in the PMTs decreased the measured decay time with increasing signal attenuation. For longer phosphorescence decay times, in the millisecond regime, nonlinearity effects led to an increase in the measured decay time with increasing signal attenuation. The specific detector nonlinearity response will vary among detectors, but the introduced methodology for detector analysis is a useful resource for assessing and improving accuracy in lifetime phosphor thermometry measurements.
- Open Access
- 1 January 2021
- Published by Elsevier in Proceedings of the Combustion Institute
- Vol. 38 (3) , 3929-3938
Temporal temperature measurement on burning biomass pellets using phosphor thermometry and two-line atomic fluorescence
- 1 January 2021
- Published by Elsevier in Proceedings of the Combustion Institute
- Vol. 38 (3) , 3929-3938
Open AccessTemporal temperature measurement on burning biomass pellets using phosphor thermometry and two-line atomic fluorescence