PLPeng Li

Peng Li

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Peng Li has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Dose-efficient X-ray Bragg ptychography imaging via a mixed sparse sampling strategy

    by Tingyou Li, Jizhou Li, Peng Li

    X-ray Bragg ptychography is a powerful coherent diffraction imaging technique capable of resolving nanoscale structural and strain information in crystalline materials. The technique typically requires repetitive positional scans of the sample across a series of sample rocking angles, followed by a computational inversion process for image reconstruction. However, the prolonged data acquisition imposes stringent requirements on experimental stability and poses significant challenges to achieving high-quality imaging. To address these issues, we propose a dose-efficient Bragg ptychography framework that sparsifies the scan positions in a rolling-shifting manner across different rocking angles. This approach enables a substantial reduction in the number of scan positions while largely preserving reconstruction fidelity. Experimental results demonstrate the effectiveness of the proposed method even when the data volume is reduced by an order of magnitude. Consequently, the framework alleviates the stringent stability constraints, mitigates radiation damage concerns, and enhances the practical applicability of Bragg ptychography.

  • Crystallisation in biomineral mollusc shell studied by 3D Bragg ptychography

    by Tilman A. Grünewald, Peng Li, Julien Duboisset, Julius Nouet, Oier Bikondoa, Jeremie Vidal-Dupiol, Denis Saulnier, Manfred Burghammer, Virginie Chamard

    Biomineralisation integrates complex biologically assisted physico-chemical processes leading to an extraordinary diversity of calcareous biomineral crystalline architectures, in intriguing contrast with the consistent presence of a submicrometric granular structure. While the repeated observation of amorphous calcium carbonate is interpreted as a precursor to the crystalline phase, the crystalline transition mechanisms are poorly understood. Access to the crystalline architecture at the mesoscale, i.e., over a few granules, is key to building realistic crystallisation models. Here we exploit three-dimensional X-ray Bragg ptychography microscopy to provide a series of nanoscale maps of the crystalline structure within the “single-crystalline” prism of the prismatic layer of a Pinctada margaritifera shell. The mesocrystalline organisation exhibits several micrometre-sized iso-oriented/iso-strained crystalline domains, the detailed studies of which reveal the presence of crystalline coherence domains ranging from 130 to 550 nm in size. The further increase in the lattice parameter with the size of the coherence domain likely results from the crystallisation mechanism, pointing towards a maturation process occurring after the initial amorphous-to-crystalline transition.


  • Open Access

    4th generation synchrotron source boosts crystalline imaging at the nanoscale

    by Peng Li, Marc Allain, Tilman A. Grünewald, Marcus Rommel, Andrea Campos, Dina Carbone, Virginie Chamard

    New 4th-generation synchrotron sources, with their increased brilliance, promise to greatly improve the performances of coherent X-ray microscopy. This perspective is of major interest for crystal microscopy, which aims at revealing the 3D crystalline structure of matter at the nanoscale, an approach strongly limited by the available coherent flux. Our results, based on Bragg ptychography experiments performed at the first 4th-generation synchrotron source, demonstrate the possibility of retrieving a high-quality image of the crystalline sample, with unprecedented quality. Importantly, the larger available coherent flux produces datasets with enough information to overcome experimental limitations, such as strongly deteriorated scanning conditions. We show this achievement would not be possible with 3rd-generation sources, a limit that has inhibited the development of this otherwise powerful microscopy method, so far. Hence, the advent of next-generation synchrotron sources not only makes Bragg ptychography suitable for high throughput studies but also strongly relaxes the associated experimental constraints, making it compatible with a wider range of experimental set-ups at the new synchrotrons.


  • Open Access

    Revealing nano-scale lattice distortions in implanted material with 3D Bragg ptychography

    by Peng Li, Nicholas W. Phillips, Steven Leake, Marc Allain, Felix Hofmann, Virginie Chamard

    Small ion-irradiation-induced defects can dramatically alter material properties and speed up degradation. Unfortunately, most of the defects irradiation creates are below the visibility limit of state-of-the-art microscopy. As such, our understanding of their impact is largely based on simulations with major unknowns. Here we present an x-ray crystalline microscopy approach, able to image with high sensitivity, nano-scale 3D resolution and extended field of view, the lattice strains and tilts in crystalline materials. Using this enhanced Bragg ptychography tool, we study the damage helium-ion-irradiation produces in tungsten, revealing a series of crystalline details in the 3D sample. Our results lead to the conclusions that few-atom-large ‘invisible’ defects are likely isotropic in orientation and homogeneously distributed. A partially defect-denuded region is observed close to a grain boundary. These findings open up exciting perspectives for the modelling of irradiation damage and the detailed analysis of crystalline properties in complex materials.


  • Lensless LED matrix ptychographic microscope: problems and solutions

    by Peng Li, Andrew Maiden

    In this paper, a lensless microscope based on ptychography is presented. It disposes of the mechanic movement necessary for conventional ptychography, instead using an LED matrix to obtain a diverse set of diffraction data. This data is subject to multiple experimental factors that deviate from the standard version of ptychography: namely, imprecise knowledge of the LED positions, partial temporal and spatial coherence, and varying brightness and illumination distribution between individual LEDs. Despite these difficulties, we show here that the diversity in the ptychographic data allows an iterative phase retrieval algorithm to recover excellent, high-resolution images of a resolution test target and a biological sample.


  • Open Access

    Multi-slice ptychographic tomography

    by Peng Li, Andrew Maiden

    Ptychography is a form of Coherent Diffractive Imaging, where diffraction patterns are processed by iterative algorithms to recover an image of a specimen. Although mostly applied in two dimensions, ptychography can be extended to produce three dimensional images in two ways: via multi-slice ptychography or ptychographic tomography. Ptychographic tomography relies on 2D ptychography to supply projections to conventional tomographic algorithms, whilst multi-slice ptychography uses the redundancy in ptychographic data to split the reconstruction into a series of axial slices. Whilst multi-slice ptychography can handle multiple-scattering thick specimens and has a much smaller data requirement than ptychographic tomography, its depth resolution is relatively poor. Here we propose an imaging modality that combines the benefits of the two approaches, enabling isotropic 3D resolution imaging of thick specimens with a small number of angular measurements. Optical experiments validate our proposed method.


  • Open Access

    Optical ptychography with extended depth of field

    by Peng Li, Andrew Maiden

    Ptychography is an increasingly popular phase imaging technique. However, like any imaging technique it has a depth of field that limits the volume of a thick specimen that can be imaged in focus. Here, we have proposed to extend the depth of field using a multislice calculation model; an optical experiment successfully demonstrates our proposal.


  • Ten implementations of ptychography

    by Peng Li, Andrew M. Maiden

    Summary: Ptychography is an increasingly popular phase retrieval imaging technique, able to routinely deliver quantitative phase images with extended field of view at diffraction limited resolution. Different variants of this technique, like Bragg ptychography and Fourier ptychography, have also been developed and applied to various fields. Here we experimentally demonstrate 10 ways to implement the conventional real space transmission ptychography, and compare their properties to provide a guide to choosing the optimal setup for a specific application.