Takahiro Kikuchi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Takahiro Kikuchi has a total of 63 co-authors. Here are the top co-authors by number of shared publications:
- Akira Sato
National Institute of Advanced Industrial Science and Technology, Tsukuba, Japan
6 shared publications - Daiji Fukuda
National Institute of Advanced Industrial Science and Technology
6 shared publications - Fuminori Hirayama
National Institute of Advanced Industrial Science and Technology
6 shared publications - Satoshi Kohjiro
National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Japan
5 shared publications - Ryan Smith
National Institute of Advanced Industrial Science and Technology (AIST)
4 shared publications - Tetsuya Tsuruta
National Institute of Advanced Industrial Science and Technology, Tsukuba, Ibaraki, Japan
4 shared publications
Latest Publications
- Open Access
- 2 September 2026
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 26 (3)
Direct observation of photon-induced vortices in superconducting films
Nucleation of vortex-antivortex pairs (VAPs) is believed to play a central role in the photon detection mechanism of superconducting detectors; however, their direct dynamic observation has remained challenging. Here, we report the direct observation of photon-induced VAP dynamics in a current-carrying superconductor as quantized voltage signals following photon absorption. The observed signals are interpreted as discrete phase-slip events, where each vortex traversal induces a 2 π phase change of the superconducting order parameter, resulting in a quantized voltage pulse whose time integral is given by the magnetic flux quantum Φ 0 . We analyze the resulting quantized signals as a function of bias current, base temperature, and input photon-number states and find that the number of VAPs generated per absorbed photon becomes effectively stabilized under specific conditions. Under these conditions, we demonstrate photon-number-resolving capability by directly counting phase-slip-induced voltage quanta. Our results reveal a detection mechanism governed by phase dynamics rather than conventional resistive transitions and represent the first demonstration of photon-number resolution based on VAP counting, enabling fast multi-photon-resolving superconducting detectors for quantum optics.
- 2 September 2026
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 26 (3)
Open AccessDirect observation of photon-induced vortices in superconducting films
Nucleation of vortex-antivortex pairs (VAPs) is believed to play a central role in the photon detection mechanism of superconducting detectors; however, their direct dynamic observation has remained challenging. Here, we report the direct observation of photon-induced VAP dynamics in a current-carrying superconductor as quantized voltage signals following photon absorption. The observed signals are interpreted as discrete phase-slip events, where each vortex traversal induces a 2 π phase change of the superconducting order parameter, resulting in a quantized voltage pulse whose time integral is given by the magnetic flux quantum Φ 0 . We analyze the resulting quantized signals as a function of bias current, base temperature, and input photon-number states and find that the number of VAPs generated per absorbed photon becomes effectively stabilized under specific conditions. Under these conditions, we demonstrate photon-number-resolving capability by directly counting phase-slip-induced voltage quanta. Our results reveal a detection mechanism governed by phase dynamics rather than conventional resistive transitions and represent the first demonstration of photon-number resolution based on VAP counting, enabling fast multi-photon-resolving superconducting detectors for quantum optics.
- Open Access
- 1 July 2026
- Published by AIP Publishing in APL Photonics
- Vol. 11 (7)
Development of transition-edge sensors with high detection efficiency and fast response time
This study developed transition-edge sensors (TESs), which can achieve high detection efficiency and fast response time through an optimized optical cavity design. Their suitability for optical quantum information processing was confirmed. Furthermore, we developed TESs with two different sensitive area sizes—8 × 7 ţm2, 12 × 11 ţm2—and systematically evaluated their performances. By employing a titanium (Ti)/gold (Au) bilayer with a relatively high transition temperature as the sensitive element, we achieved a fast total response time—defined as the sum of the rise and decay times—of ∼160 ns. Furthermore, the optical cavity structure—predicted by simulations to achieve a photon absorptance of 99.9% at 1550 nm—yielded measured system detection efficiencies of 94.7% ± 0.62% for the 8 × 7 ţm2 TES and 99.0% ± 0.60% for the 12 × 11 ţm2 TES. Photon response measurements indicate an energy resolution of 0.20 eV for the 8 × 7 ţm2 TES and 0.37 eV for the 12 × 11 ţm2 TES. These results establish that the proposed TESs are the fastest and most efficient devices reported to date. The proposed devices offer a high detection efficiency, high count rate, and accurate photon-number resolution. Therefore, they provide a breakthrough platform for scalable fault-tolerant quantum information processing and enable significant advances in experimental quantum optics.
- 1 July 2026
- Published by AIP Publishing in APL Photonics
- Vol. 11 (7)
Open AccessDevelopment of transition-edge sensors with high detection efficiency and fast response time
This study developed transition-edge sensors (TESs), which can achieve high detection efficiency and fast response time through an optimized optical cavity design. Their suitability for optical quantum information processing was confirmed. Furthermore, we developed TESs with two different sensitive area sizes—8 × 7 ţm2, 12 × 11 ţm2—and systematically evaluated their performances. By employing a titanium (Ti)/gold (Au) bilayer with a relatively high transition temperature as the sensitive element, we achieved a fast total response time—defined as the sum of the rise and decay times—of ∼160 ns. Furthermore, the optical cavity structure—predicted by simulations to achieve a photon absorptance of 99.9% at 1550 nm—yielded measured system detection efficiencies of 94.7% ± 0.62% for the 8 × 7 ţm2 TES and 99.0% ± 0.60% for the 12 × 11 ţm2 TES. Photon response measurements indicate an energy resolution of 0.20 eV for the 8 × 7 ţm2 TES and 0.37 eV for the 12 × 11 ţm2 TES. These results establish that the proposed TESs are the fastest and most efficient devices reported to date. The proposed devices offer a high detection efficiency, high count rate, and accurate photon-number resolution. Therefore, they provide a breakthrough platform for scalable fault-tolerant quantum information processing and enable significant advances in experimental quantum optics.
- Open Access
- 18 March 2026
- Published by American Physical Society (APS) in Physical Review D
- Vol. 113 (5)
Probing internal conversion and dark-matter-induced deexcitation of Ta 180 m with a γ -ray TES array
We propose and evaluate a source-equals-detector search for the deexcitation of the long-lived isomer Ta 180 m in natural tantalum (Ta), using a γ -ray transition-edge-sensor (TES) array. Two capabilities absent in conventional high-purity germanium (HPGe) searches are exploited: (i) near-unity containment of low-energy secondaries [internal-conversion (IC) electrons and characteristic x-rays] and of the nuclear recoil, enabling a calorimetric, event-by-event measurement of the total deposited energy in the absorber; and (ii) a delayed-coincidence tag using the subsequent Ta 180 electron-capture (EC) decay to Hf 180 . We evaluate the 3 σ discovery reach for IC and for dark-matter (DM)-induced deexcitation in two benchmark scenarios: a strongly interacting DM subcomponent and inelastic DM with off diagonal couplings. Using a background model based on intrinsic radioactivity in the Ta absorber and realistic detector performance, we show that arrays with N TES = 256 and 1,000 pixels can reach the theoretically expected IC half-life within 2.6 yr and 0.66 yr, respectively. For an array with N TES = 10 4 and a five-year exposure, the projected sensitivity to DM-induced de-excitation surpasses limits inferred from HPGe nonobservations of Ta 180 m and probes regions of parameter space not covered by current direct-detection experiments.
- 18 March 2026
- Published by American Physical Society (APS) in Physical Review D
- Vol. 113 (5)
Open AccessProbing internal conversion and dark-matter-induced deexcitation of Ta 180 m with a γ -ray TES array
We propose and evaluate a source-equals-detector search for the deexcitation of the long-lived isomer Ta 180 m in natural tantalum (Ta), using a γ -ray transition-edge-sensor (TES) array. Two capabilities absent in conventional high-purity germanium (HPGe) searches are exploited: (i) near-unity containment of low-energy secondaries [internal-conversion (IC) electrons and characteristic x-rays] and of the nuclear recoil, enabling a calorimetric, event-by-event measurement of the total deposited energy in the absorber; and (ii) a delayed-coincidence tag using the subsequent Ta 180 electron-capture (EC) decay to Hf 180 . We evaluate the 3 σ discovery reach for IC and for dark-matter (DM)-induced deexcitation in two benchmark scenarios: a strongly interacting DM subcomponent and inelastic DM with off diagonal couplings. Using a background model based on intrinsic radioactivity in the Ta absorber and realistic detector performance, we show that arrays with N TES = 256 and 1,000 pixels can reach the theoretically expected IC half-life within 2.6 yr and 0.66 yr, respectively. For an array with N TES = 10 4 and a five-year exposure, the projected sensitivity to DM-induced de-excitation surpasses limits inferred from HPGe nonobservations of Ta 180 m and probes regions of parameter space not covered by current direct-detection experiments.
- 12 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (6) , 1-7
Real-Time Signal Processing on Transition-Edge Sensor for Confocal Spectral Microscopy
Broadband confocal spectral imaging in life-science microscopy often requires high excitation power to secure sufficient signal-to-noise ratio, which can induce phototoxicity and photobleaching. A transition-edge sensor (TES) offers high-efficiency, low-dark-count, single-photon energy-resolving detection; however, under continuous-wave excitation, the microsecond-scale TES pulse decay makes the readout susceptible to pulse pile-up, degrading both energy resolution and throughput. Here we developed a practical TES-based confocal spectral imaging platform by implementing a trapezoidal filtering algorithm as a linear time-invariant convolution on a field-programmable gate array (FPGA) for real-time pulse-height analysis. The FPGA synchronizes TES pulse-height information with scan metadata and streams the data to a host PC to assemble a spectral image cube. Using an 848 nm pulsed laser, we calibrated the pulse-height bin to photon energy with a third-order polynomial and converted energy histograms to wavelength via a Jacobian transformation. The proposed TES laser-scanning microscope (TES-LSM) successfully acquired spectroscopic images of fixed bovine pulmonary artery endothelial cells stained with Alexa Fluor 488 at an excitation power of 112 nW, achieving an image signal-to-noise ratio exceeding 30. In repetition-rate tests, the trapezoidal filter maintains nearly constant performance ($E/\Delta E \approx 5$) up to 100 kHz and enables photon-number discrimination up to 120 kHz, outperforming an optimal filter at high count rates. These results demonstrate real-time, pile-up-tolerant TES readout for low-power confocal spectral imaging.
- 12 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (6) , 1-7
Real-Time Signal Processing on Transition-Edge Sensor for Confocal Spectral Microscopy
Broadband confocal spectral imaging in life-science microscopy often requires high excitation power to secure sufficient signal-to-noise ratio, which can induce phototoxicity and photobleaching. A transition-edge sensor (TES) offers high-efficiency, low-dark-count, single-photon energy-resolving detection; however, under continuous-wave excitation, the microsecond-scale TES pulse decay makes the readout susceptible to pulse pile-up, degrading both energy resolution and throughput. Here we developed a practical TES-based confocal spectral imaging platform by implementing a trapezoidal filtering algorithm as a linear time-invariant convolution on a field-programmable gate array (FPGA) for real-time pulse-height analysis. The FPGA synchronizes TES pulse-height information with scan metadata and streams the data to a host PC to assemble a spectral image cube. Using an 848 nm pulsed laser, we calibrated the pulse-height bin to photon energy with a third-order polynomial and converted energy histograms to wavelength via a Jacobian transformation. The proposed TES laser-scanning microscope (TES-LSM) successfully acquired spectroscopic images of fixed bovine pulmonary artery endothelial cells stained with Alexa Fluor 488 at an excitation power of 112 nW, achieving an image signal-to-noise ratio exceeding 30. In repetition-rate tests, the trapezoidal filter maintains nearly constant performance ($E/\Delta E \approx 5$) up to 100 kHz and enables photon-number discrimination up to 120 kHz, outperforming an optimal filter at high count rates. These results demonstrate real-time, pile-up-tolerant TES readout for low-power confocal spectral imaging.
- 21 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (6) , 1-7
High Energy Collection Efficiency in a Ti/Au/Ti/Au Four-Layer Transition Edge Sensor
A superconducting transition edge sensor(TES), a type of photon-number-resolving detector, is essential for quantum information applications that utilize highly non-classical quantum states. For these applications, TES devices must simultaneously achieve high detection efficiency and high energy resolution. Matching the mode field diameter of optical fibers requires a sufficiently large sensitive area, which introduces an alignment tolerance. However, the increased heat capacity associated with a larger area degrades the energy resolution and consequently reduces the accuracy of the photon-number discrimination. Thus, developing a TES with both a large sensitive area and high energy resolution remains highly challenging. To address this issue, we developed a Ti/Au/Ti/Au four-layer structure TES. Theoretically, stacking metal materials with different Debye temperatures confines high-energy phonon within the TES. This suppression of high-energy phonon loss during energy down-conversion improves the energy collection efficiency, thereby enhancing the energy resolution. Furthermore, lowering the transition temperature through the proximity effect provides additional improvement. Consequently, we evaluated the enhancement of energy resolution resulting from phonon confinement and the reduction in transition temperature. As a result, in contrast to conventional Ti/Au bilayer TESs, the four-layer TES with a size of 21 ${\mu }$m × 21 $\mu$m exhibited photon-number-resolving ability at 1550nm, achieving an energy resolution of 0.32eV. While the bilayer TES showed a transition temperature of around 320 mK, the four-layer TES achieved a significantly lower value of 179 mK. Moreover, the energy collection efficiency exhibits no dependence on incident photon wavelengths, resulting in an average value of 97.4 $\pm$ 1.0 % over all measured data points, compared with approximately 80 % for the bilayer TES. These results demonstrate that multilayer TES structures with different Debye temperatures can effectively reduce the transition temperature and confine phonons, thereby improving energy resolution.
- 21 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (6) , 1-7
High Energy Collection Efficiency in a Ti/Au/Ti/Au Four-Layer Transition Edge Sensor
A superconducting transition edge sensor(TES), a type of photon-number-resolving detector, is essential for quantum information applications that utilize highly non-classical quantum states. For these applications, TES devices must simultaneously achieve high detection efficiency and high energy resolution. Matching the mode field diameter of optical fibers requires a sufficiently large sensitive area, which introduces an alignment tolerance. However, the increased heat capacity associated with a larger area degrades the energy resolution and consequently reduces the accuracy of the photon-number discrimination. Thus, developing a TES with both a large sensitive area and high energy resolution remains highly challenging. To address this issue, we developed a Ti/Au/Ti/Au four-layer structure TES. Theoretically, stacking metal materials with different Debye temperatures confines high-energy phonon within the TES. This suppression of high-energy phonon loss during energy down-conversion improves the energy collection efficiency, thereby enhancing the energy resolution. Furthermore, lowering the transition temperature through the proximity effect provides additional improvement. Consequently, we evaluated the enhancement of energy resolution resulting from phonon confinement and the reduction in transition temperature. As a result, in contrast to conventional Ti/Au bilayer TESs, the four-layer TES with a size of 21 ${\mu }$m × 21 $\mu$m exhibited photon-number-resolving ability at 1550nm, achieving an energy resolution of 0.32eV. While the bilayer TES showed a transition temperature of around 320 mK, the four-layer TES achieved a significantly lower value of 179 mK. Moreover, the energy collection efficiency exhibits no dependence on incident photon wavelengths, resulting in an average value of 97.4 $\pm$ 1.0 % over all measured data points, compared with approximately 80 % for the bilayer TES. These results demonstrate that multilayer TES structures with different Debye temperatures can effectively reduce the transition temperature and confine phonons, thereby improving energy resolution.
- 19 August 2025
- Published by Springer Nature in Journal of Low Temperature Physics
- Vol. 221 (1-6) , 199-208
Array of Optical Transition-Edge Sensors Fabricated by Ion-Milling Process Evaluated with Microwave Multiplexer for 100 or More Sensors
- 19 August 2025
- Published by Springer Nature in Journal of Low Temperature Physics
- Vol. 221 (1-6) , 199-208
Array of Optical Transition-Edge Sensors Fabricated by Ion-Milling Process Evaluated with Microwave Multiplexer for 100 or More Sensors
- 11 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 35 (5) , 1-4
Development of Transition Edge Sensor Array for Wide Energy Range Gamma-Ray Spectroscopy
We have developed a gamma-ray spectrometer based on 8-pixel superconducting transition edge sensor (TES) microcalorimeter which can detect gamma rays with energies up to 0.8 MeV. We applied 0.8 mm × 0.8 mm × 0.8 mm Sn absorbers which provide sufficient saturation energies and absorption efficiencies for gamma rays with energies more than 0.2 MeV. We used a mixed source of 137Cs and 22Na which emits 32 keV X-rays, 511 keV annihilation radiations and 662 keV gamma rays. Signals from our detector were simultaneously readout using microwave multiplexing. The energy resolution of our 8-pixel TES microcalorimeters were ${\text{330}}\,{\text{ eV}} \leq \ \Delta {{E}_{\text{FWHM}}} \leq {\text{7.2}}\ \text{keV}$, and 3 pixels showed better energy resolution than 400 eV for 662 keV gamma rays. The 511 keV annihilation peaks were $\Delta E > {\text{1}}\ \text{keV}$, which are most likely caused by the Doppler broadening effect.
- 11 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 35 (5) , 1-4
Development of Transition Edge Sensor Array for Wide Energy Range Gamma-Ray Spectroscopy
We have developed a gamma-ray spectrometer based on 8-pixel superconducting transition edge sensor (TES) microcalorimeter which can detect gamma rays with energies up to 0.8 MeV. We applied 0.8 mm × 0.8 mm × 0.8 mm Sn absorbers which provide sufficient saturation energies and absorption efficiencies for gamma rays with energies more than 0.2 MeV. We used a mixed source of 137Cs and 22Na which emits 32 keV X-rays, 511 keV annihilation radiations and 662 keV gamma rays. Signals from our detector were simultaneously readout using microwave multiplexing. The energy resolution of our 8-pixel TES microcalorimeters were ${\text{330}}\,{\text{ eV}} \leq \ \Delta {{E}_{\text{FWHM}}} \leq {\text{7.2}}\ \text{keV}$, and 3 pixels showed better energy resolution than 400 eV for 662 keV gamma rays. The 511 keV annihilation peaks were $\Delta E > {\text{1}}\ \text{keV}$, which are most likely caused by the Doppler broadening effect.
- 6 April 2024
- Published by Springer Nature in Journal of Low Temperature Physics
- Vol. 215 (3-4) , 170-176
Demonstration of Simultaneous Optical Transition-Edge Sensors Readout Using Microwave SQUID Multiplexer with 5 MHz Flux Ramp Modulation
- 6 April 2024
- Published by Springer Nature in Journal of Low Temperature Physics
- Vol. 215 (3-4) , 170-176
Demonstration of Simultaneous Optical Transition-Edge Sensors Readout Using Microwave SQUID Multiplexer with 5 MHz Flux Ramp Modulation
- 20 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33 (5) , 1-6
A 320-keV Spectrometer Based on 8-Pixel Transition Edge Sensor With Trilayer Membrane and Novel Numerical Analysis
A 320-keV spectrometer based on an 8-pixel transition edge sensor (TES) has been developed. It involves a unique 7-μm thick membrane consisting of silicon dioxide (SiO 2 ), silicon nitride (Si x N y ), and SiO 2 . This membrane supports a 0.8-mm thick Sn absorber with suitable stopping power for photon energy E=320 keV and is applicable up to E≈0.7 MeV. Our trilayer membrane exhibits the same thermal conductance as conventional 1-μm thick Si x N y one, i.e., G≈1.2 nW/K at the critical temperature of 115 mK. We carryoutthe spectroscopy using a 51 Cr radiationsourceand simultaneously read out the 8 pixels with a microwave SQUID multiplexer. We find a linear broadening trend be-tween the pulse peak and pulse area, even after a correction of the baseline drift due to time-varied temperature of our cryocooler. Based on the relationship, we analyze the data and succeed in avoiding degradation of the energy resolu-tion in spectra. The resultant full-width-half-maximum (FWHM) energy resolution ΔEFWHM of the measured 6 pix-els satisfies ΔE FWHM 220 keV to our knowledge.
- 20 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33 (5) , 1-6
A 320-keV Spectrometer Based on 8-Pixel Transition Edge Sensor With Trilayer Membrane and Novel Numerical Analysis
A 320-keV spectrometer based on an 8-pixel transition edge sensor (TES) has been developed. It involves a unique 7-μm thick membrane consisting of silicon dioxide (SiO 2 ), silicon nitride (Si x N y ), and SiO 2 . This membrane supports a 0.8-mm thick Sn absorber with suitable stopping power for photon energy E=320 keV and is applicable up to E≈0.7 MeV. Our trilayer membrane exhibits the same thermal conductance as conventional 1-μm thick Si x N y one, i.e., G≈1.2 nW/K at the critical temperature of 115 mK. We carryoutthe spectroscopy using a 51 Cr radiationsourceand simultaneously read out the 8 pixels with a microwave SQUID multiplexer. We find a linear broadening trend be-tween the pulse peak and pulse area, even after a correction of the baseline drift due to time-varied temperature of our cryocooler. Based on the relationship, we analyze the data and succeed in avoiding degradation of the energy resolu-tion in spectra. The resultant full-width-half-maximum (FWHM) energy resolution ΔEFWHM of the measured 6 pix-els satisfies ΔE FWHM 220 keV to our knowledge.
- 1 January 2023
- Published by Optica Publishing Group
- p. M1B.4
Power Efficient Core Pumped Multicore Erbium Doped Optical Fiber Amplifier
A core pumped 4-core erbium doped optical fiber amplifier with a pump fan-in integrated combiner achieved the highest optical power conversion efficiency of 32.2% among reported C-band multicore erbium doped optical fiber amplifiers.
- 1 January 2023
- Published by Optica Publishing Group
- p. M1B.4
Power Efficient Core Pumped Multicore Erbium Doped Optical Fiber Amplifier
A core pumped 4-core erbium doped optical fiber amplifier with a pump fan-in integrated combiner achieved the highest optical power conversion efficiency of 32.2% among reported C-band multicore erbium doped optical fiber amplifiers.