Satoshi Kohjiro
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Satoshi Kohjiro has a total of 230 co-authors. Here are the top co-authors by number of shared publications:
- Hirotake Yamamori
National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Japan
19 shared publications - Fuminori Hirayama
National Institute of Advanced Industrial Science and Technology
17 shared publications - Shuuichi Nagasawa
National Institute of Advanced Industrial Science and Technology (AIST)
12 shared publications Atsushi Wakatsuki
NTT Photonics Laboratories, NTT, Atsugi Kanagawa Japan
11 shared publicationsA. Shoji
National Institute of Advanced Industrial Science and Technology, AIST Tsukuba Central 2, 1-1-1 Umezono, Ibaraki 305-8568, Japan
10 shared publications- Akira Sato
National Institute of Advanced Industrial Science and Technology, Tsukuba, Japan
10 shared publications
Latest Publications
- 11 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 35 (5) , 1-4
Development of Transition Edge Sensor Array for Wide Energy Range Gamma-Ray Spectroscopy
We have developed a gamma-ray spectrometer based on 8-pixel superconducting transition edge sensor (TES) microcalorimeter which can detect gamma rays with energies up to 0.8 MeV. We applied 0.8 mm × 0.8 mm × 0.8 mm Sn absorbers which provide sufficient saturation energies and absorption efficiencies for gamma rays with energies more than 0.2 MeV. We used a mixed source of 137Cs and 22Na which emits 32 keV X-rays, 511 keV annihilation radiations and 662 keV gamma rays. Signals from our detector were simultaneously readout using microwave multiplexing. The energy resolution of our 8-pixel TES microcalorimeters were ${\text{330}}\,{\text{ eV}} \leq \ \Delta {{E}_{\text{FWHM}}} \leq {\text{7.2}}\ \text{keV}$, and 3 pixels showed better energy resolution than 400 eV for 662 keV gamma rays. The 511 keV annihilation peaks were $\Delta E > {\text{1}}\ \text{keV}$, which are most likely caused by the Doppler broadening effect.
- 11 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 35 (5) , 1-4
Development of Transition Edge Sensor Array for Wide Energy Range Gamma-Ray Spectroscopy
We have developed a gamma-ray spectrometer based on 8-pixel superconducting transition edge sensor (TES) microcalorimeter which can detect gamma rays with energies up to 0.8 MeV. We applied 0.8 mm × 0.8 mm × 0.8 mm Sn absorbers which provide sufficient saturation energies and absorption efficiencies for gamma rays with energies more than 0.2 MeV. We used a mixed source of 137Cs and 22Na which emits 32 keV X-rays, 511 keV annihilation radiations and 662 keV gamma rays. Signals from our detector were simultaneously readout using microwave multiplexing. The energy resolution of our 8-pixel TES microcalorimeters were ${\text{330}}\,{\text{ eV}} \leq \ \Delta {{E}_{\text{FWHM}}} \leq {\text{7.2}}\ \text{keV}$, and 3 pixels showed better energy resolution than 400 eV for 662 keV gamma rays. The 511 keV annihilation peaks were $\Delta E > {\text{1}}\ \text{keV}$, which are most likely caused by the Doppler broadening effect.
- 6 April 2024
- Published by Springer Nature in Journal of Low Temperature Physics
- Vol. 215 (3-4) , 170-176
Demonstration of Simultaneous Optical Transition-Edge Sensors Readout Using Microwave SQUID Multiplexer with 5 MHz Flux Ramp Modulation
- 6 April 2024
- Published by Springer Nature in Journal of Low Temperature Physics
- Vol. 215 (3-4) , 170-176
Demonstration of Simultaneous Optical Transition-Edge Sensors Readout Using Microwave SQUID Multiplexer with 5 MHz Flux Ramp Modulation
- 20 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33 (5) , 1-6
A 320-keV Spectrometer Based on 8-Pixel Transition Edge Sensor With Trilayer Membrane and Novel Numerical Analysis
A 320-keV spectrometer based on an 8-pixel transition edge sensor (TES) has been developed. It involves a unique 7-μm thick membrane consisting of silicon dioxide (SiO 2 ), silicon nitride (Si x N y ), and SiO 2 . This membrane supports a 0.8-mm thick Sn absorber with suitable stopping power for photon energy E=320 keV and is applicable up to E≈0.7 MeV. Our trilayer membrane exhibits the same thermal conductance as conventional 1-μm thick Si x N y one, i.e., G≈1.2 nW/K at the critical temperature of 115 mK. We carryoutthe spectroscopy using a 51 Cr radiationsourceand simultaneously read out the 8 pixels with a microwave SQUID multiplexer. We find a linear broadening trend be-tween the pulse peak and pulse area, even after a correction of the baseline drift due to time-varied temperature of our cryocooler. Based on the relationship, we analyze the data and succeed in avoiding degradation of the energy resolu-tion in spectra. The resultant full-width-half-maximum (FWHM) energy resolution ΔEFWHM of the measured 6 pix-els satisfies ΔE FWHM 220 keV to our knowledge.
- 20 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33 (5) , 1-6
A 320-keV Spectrometer Based on 8-Pixel Transition Edge Sensor With Trilayer Membrane and Novel Numerical Analysis
A 320-keV spectrometer based on an 8-pixel transition edge sensor (TES) has been developed. It involves a unique 7-μm thick membrane consisting of silicon dioxide (SiO 2 ), silicon nitride (Si x N y ), and SiO 2 . This membrane supports a 0.8-mm thick Sn absorber with suitable stopping power for photon energy E=320 keV and is applicable up to E≈0.7 MeV. Our trilayer membrane exhibits the same thermal conductance as conventional 1-μm thick Si x N y one, i.e., G≈1.2 nW/K at the critical temperature of 115 mK. We carryoutthe spectroscopy using a 51 Cr radiationsourceand simultaneously read out the 8 pixels with a microwave SQUID multiplexer. We find a linear broadening trend be-tween the pulse peak and pulse area, even after a correction of the baseline drift due to time-varied temperature of our cryocooler. Based on the relationship, we analyze the data and succeed in avoiding degradation of the energy resolu-tion in spectra. The resultant full-width-half-maximum (FWHM) energy resolution ΔEFWHM of the measured 6 pix-els satisfies ΔE FWHM 220 keV to our knowledge.
- 29 November 2021
- Published by AIP Publishing in Applied Physics Letters
- Vol. 119 (22) , 222602
Gamma-ray transition edge sensor with a thick SiO2/SixNy/SiO2 membrane
Thick membranes of the gamma-ray transition-edge sensor ( -TES) generally exhibit great mechanical strength and can support a bulk metal absorber typical for -TES. However, for conventional silicon-nitride (SixNy) membranes, thermal conductance (G) is proportional to the thickness, indicating that thicker membranes provide larger thermal-fluctuation noise in TESs. We propose a thick-trilayer membrane consisting of the silicon oxide (SiO2), SixNy, and SiO2 layers. The SixNy layer accounts for 5.8 μm of the total 6.9 μm, and thus, it is expected to be hard compared with conventional SixNy membranes with a typical thickness below 1 μm. G of the trilayer membrane is characterized as a function of heat-transport distance (L), and the G-L relation follows that of the intermediate model between ballistic and diffusive transports. Resulting G of the thick-trilayer membrane is 1.1–1.7 nW/K, which is not far from the one reported by conventional SixNy membranes. Gamma-ray spectroscopy around 93 keV is carried out based on series biased 5-pixels TES. The best full-width-half-maximum energy resolution among all pixels under characterization is 43.1 1.6 eV for 93-keV, which is close to the median value of a state-of-the-art 236-pixels -TES in the literature. The measured low-frequency noise can be represented by theoretical phonon noise and its excess component with the same order as conventional ones. The thick-trilayer membrane is demonstrated to be able to work without any problems in a -TES regime.- 29 November 2021
- Published by AIP Publishing in Applied Physics Letters
- Vol. 119 (22) , 222602
Gamma-ray transition edge sensor with a thick SiO2/SixNy/SiO2 membrane
Thick membranes of the gamma-ray transition-edge sensor ( -TES) generally exhibit great mechanical strength and can support a bulk metal absorber typical for -TES. However, for conventional silicon-nitride (SixNy) membranes, thermal conductance (G) is proportional to the thickness, indicating that thicker membranes provide larger thermal-fluctuation noise in TESs. We propose a thick-trilayer membrane consisting of the silicon oxide (SiO2), SixNy, and SiO2 layers. The SixNy layer accounts for 5.8 μm of the total 6.9 μm, and thus, it is expected to be hard compared with conventional SixNy membranes with a typical thickness below 1 μm. G of the trilayer membrane is characterized as a function of heat-transport distance (L), and the G-L relation follows that of the intermediate model between ballistic and diffusive transports. Resulting G of the thick-trilayer membrane is 1.1–1.7 nW/K, which is not far from the one reported by conventional SixNy membranes. Gamma-ray spectroscopy around 93 keV is carried out based on series biased 5-pixels TES. The best full-width-half-maximum energy resolution among all pixels under characterization is 43.1 1.6 eV for 93-keV, which is close to the median value of a state-of-the-art 236-pixels -TES in the literature. The measured low-frequency noise can be represented by theoretical phonon noise and its excess component with the same order as conventional ones. The thick-trilayer membrane is demonstrated to be able to work without any problems in a -TES regime.- 25 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 31 (5) , 1-4
Optimization for Device Structure of Superconducting Transition Edge Sensor Coupled With Heavy Metal Absorber
We are currently developing transition edge sensors (TES) for the gamma-ray spectroscopy using a single gold bump post to connect the bulk metal absorber to the superconducting thin film. In order to develop a multi-pixel TES array for the gamma-ray spectroscopy, a stable and feasible method of mounting gamma-ray absorbers is indispensable. However, mounting gamma-ray absorbers on a single gold bump post is difficult from a structural stability and process development perspective. To overcome this problem, we have established a method to improve the structural stability in mounting gamma-ray absorbers by using 4 gold bump posts. We developed a TES array coupled with a Sn absorber which was mounted with our newly established method and used it to collect gamma-ray spectrum from an Am 241 source. The rise time of the signal waveform was shorter than 200 μs and showed a favorable energy resolution considering the high transition temperature of the Ir/Au superconducting film. This new method to mount gamma-ray absorbers on TES will contribute to the development of multi-pixel TES arrays using bulk metal for gamma-ray absorbers.
- 25 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 31 (5) , 1-4
Optimization for Device Structure of Superconducting Transition Edge Sensor Coupled With Heavy Metal Absorber
We are currently developing transition edge sensors (TES) for the gamma-ray spectroscopy using a single gold bump post to connect the bulk metal absorber to the superconducting thin film. In order to develop a multi-pixel TES array for the gamma-ray spectroscopy, a stable and feasible method of mounting gamma-ray absorbers is indispensable. However, mounting gamma-ray absorbers on a single gold bump post is difficult from a structural stability and process development perspective. To overcome this problem, we have established a method to improve the structural stability in mounting gamma-ray absorbers by using 4 gold bump posts. We developed a TES array coupled with a Sn absorber which was mounted with our newly established method and used it to collect gamma-ray spectrum from an Am 241 source. The rise time of the signal waveform was shorter than 200 μs and showed a favorable energy resolution considering the high transition temperature of the Ir/Au superconducting film. This new method to mount gamma-ray absorbers on TES will contribute to the development of multi-pixel TES arrays using bulk metal for gamma-ray absorbers.
- 1 January 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (1) , 013103
Broadband high-energy resolution hard x-ray spectroscopy using transition edge sensors at SPring-8
We have succeeded in operating a transition-edge sensor (TES) spectrometer and evaluating its performance at the SPring-8 synchrotron x-ray light source. The TES spectrometer consists of a 240 pixel National Institute of Standards and Technology (NIST) TES system, and 220 pixels are operated simultaneously with an energy resolution of 4 eV at 6 keV at a rate of ∼1 c/s pixel−1. The tolerance for high count rates is evaluated in terms of energy resolution and live time fraction, leading to an empirical compromise of ∼2 × 103 c/s (all pixels) with an energy resolution of 5 eV at 6 keV. By utilizing the TES’s wideband spectroscopic capability, simultaneous multi-element analysis is demonstrated for a standard sample. We conducted x-ray absorption near-edge structure (XANES) analysis in fluorescence mode using the TES spectrometer. The excellent energy resolution of the TES enabled us to detect weak fluorescence lines from dilute samples and trace elements that have previously been difficult to resolve due to the nearly overlapping emission lines of other dominant elements. The neighboring lines of As Kα and Pb Lα2 of the standard sample were clearly resolved, and the XANES of Pb Lα2 was obtained. Moreover, the x-ray spectrum from the small amount of Fe in aerosols was distinguished from the spectrum of a blank target, which helps us to understand the targets and the environment. These results are the first important step for the application of high resolution TES-based spectroscopy at hard x-ray synchrotron facilities.
- 1 January 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (1) , 013103
Broadband high-energy resolution hard x-ray spectroscopy using transition edge sensors at SPring-8
We have succeeded in operating a transition-edge sensor (TES) spectrometer and evaluating its performance at the SPring-8 synchrotron x-ray light source. The TES spectrometer consists of a 240 pixel National Institute of Standards and Technology (NIST) TES system, and 220 pixels are operated simultaneously with an energy resolution of 4 eV at 6 keV at a rate of ∼1 c/s pixel−1. The tolerance for high count rates is evaluated in terms of energy resolution and live time fraction, leading to an empirical compromise of ∼2 × 103 c/s (all pixels) with an energy resolution of 5 eV at 6 keV. By utilizing the TES’s wideband spectroscopic capability, simultaneous multi-element analysis is demonstrated for a standard sample. We conducted x-ray absorption near-edge structure (XANES) analysis in fluorescence mode using the TES spectrometer. The excellent energy resolution of the TES enabled us to detect weak fluorescence lines from dilute samples and trace elements that have previously been difficult to resolve due to the nearly overlapping emission lines of other dominant elements. The neighboring lines of As Kα and Pb Lα2 of the standard sample were clearly resolved, and the XANES of Pb Lα2 was obtained. Moreover, the x-ray spectrum from the small amount of Fe in aerosols was distinguished from the spectrum of a blank target, which helps us to understand the targets and the environment. These results are the first important step for the application of high resolution TES-based spectroscopy at hard x-ray synchrotron facilities.
- 21 September 2020
- Published by AIP Publishing in Applied Physics Letters
- Vol. 117 (12) , 122601
Low-noise microwave SQUID multiplexed readout of 38 x-ray transition-edge sensor microcalorimeters
We report very-low-noise, fast-response, middle-scale multiplexing in a microwave superconducting quantum interference device multiplexer (MW-Mux) as a transition-edge sensor (TES) readout. Our MW-Mux is able to read 40 channels with 500 kHz sampling and has a low readout noise of (where is the magnetic flux quantum), equivalent to . By contrast, a multiplexer of less than 10 pixels with 500 kHz sampling and readout noise has so far been reported in the literature. Owing to the 500 kHz sampling, our MW-Mux exhibits a fast response to detect a TES pulse with a rise time around . We demonstrated simultaneous readout of 38 pixels from an array of x-ray TES microcalorimeters. The measured full-width values at half-maximum spectral resolution ranged from 2.79 to 4.56 eV, with a median value of 3.30 eV at 5.9 keV, including a contribution of readout noise, i.e., 0.9–1.7 eV.- 21 September 2020
- Published by AIP Publishing in Applied Physics Letters
- Vol. 117 (12) , 122601
Low-noise microwave SQUID multiplexed readout of 38 x-ray transition-edge sensor microcalorimeters
We report very-low-noise, fast-response, middle-scale multiplexing in a microwave superconducting quantum interference device multiplexer (MW-Mux) as a transition-edge sensor (TES) readout. Our MW-Mux is able to read 40 channels with 500 kHz sampling and has a low readout noise of (where is the magnetic flux quantum), equivalent to . By contrast, a multiplexer of less than 10 pixels with 500 kHz sampling and readout noise has so far been reported in the literature. Owing to the 500 kHz sampling, our MW-Mux exhibits a fast response to detect a TES pulse with a rise time around . We demonstrated simultaneous readout of 38 pixels from an array of x-ray TES microcalorimeters. The measured full-width values at half-maximum spectral resolution ranged from 2.79 to 4.56 eV, with a median value of 3.30 eV at 5.9 keV, including a contribution of readout noise, i.e., 0.9–1.7 eV.- 24 February 2020
- Published by Springer Nature in Journal of Low Temperature Physics
- Vol. 199 (3-4) , 1012-1017
Microcalorimetry of Carbon Ion Beam for Medical Treatment by Transition Edge Sensor
- 24 February 2020
- Published by Springer Nature in Journal of Low Temperature Physics
- Vol. 199 (3-4) , 1012-1017
Microcalorimetry of Carbon Ion Beam for Medical Treatment by Transition Edge Sensor
- 20 December 2019
- Published by Springer Nature in Journal of Low Temperature Physics
- Vol. 199 (1-2) , 206-211
Microwave SQUID Multiplexer for Readout of Optical Transition Edge Sensor Array
- 20 December 2019
- Published by Springer Nature in Journal of Low Temperature Physics
- Vol. 199 (1-2) , 206-211
Microwave SQUID Multiplexer for Readout of Optical Transition Edge Sensor Array
- 18 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 29 (5) , 1-5
Investigation of Large Coupling Between TES X-Ray Microcalorimeter and Microwave Multiplexer Based on Microstrip SQUID
We report on the study of a microwave superconducting quantum interference device (SQUID) multiplexer (MW-Mux) with current noise lower than that of our typical transition-edge sensor (TES) X-ray microcalorimeter. A large mutual inductance, between SQUID loop and input inductor connected to a TES X-ray microcalorimeter in series, realizes such low current noise referred to the SQUID input, but also can cause undesirable resonances which affect the SQUID performances. In this paper, we developed the MW-Mux with mutual inductance of about 370 pH, which is six times larger than that of the previous one, by adopting a spiral input coil longer than a half wavelength at the readout microwave frequency. Its characteristics were evaluated, and the results showed that the distortion of the SQUID characteristics and the degradation of its noise performance were not clearly observed. Finally, we have developed a MW-Mux microstrip SQUID with a low current noise of $\rm \lt 20 pA/\sqrt{Hz}$ which is below the typical noise of our TES X-ray microcalorimeter, $\rm 30 pA/\sqrt{Hz}$ .- 18 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 29 (5) , 1-5
Investigation of Large Coupling Between TES X-Ray Microcalorimeter and Microwave Multiplexer Based on Microstrip SQUID
We report on the study of a microwave superconducting quantum interference device (SQUID) multiplexer (MW-Mux) with current noise lower than that of our typical transition-edge sensor (TES) X-ray microcalorimeter. A large mutual inductance, between SQUID loop and input inductor connected to a TES X-ray microcalorimeter in series, realizes such low current noise referred to the SQUID input, but also can cause undesirable resonances which affect the SQUID performances. In this paper, we developed the MW-Mux with mutual inductance of about 370 pH, which is six times larger than that of the previous one, by adopting a spiral input coil longer than a half wavelength at the readout microwave frequency. Its characteristics were evaluated, and the results showed that the distortion of the SQUID characteristics and the degradation of its noise performance were not clearly observed. Finally, we have developed a MW-Mux microstrip SQUID with a low current noise of $\rm \lt 20 pA/\sqrt{Hz}$ which is below the typical noise of our TES X-ray microcalorimeter, $\rm 30 pA/\sqrt{Hz}$ .