Jia-Zheng Wan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jia-Zheng Wan has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Guo-Cheng Han
School of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin 541004, China
2 shared publications - Jin-Guang Liu
School of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin 541004, China
1 shared publication - Qing-Min Lin
School of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin 541004, China
1 shared publication - Xiao-Zhen Feng
School of Life and Environmental Sciences, Guangxi Human Physiological Information Non Invasive Detection Engineering Technology Research Center, Guangxi Key Laboratory of Metabolic Reprogramming and Intelligent Medical Engineering for Chronic Diseases, Guangxi Colleges and Universities Key Laboratory of Biomedical Sensors and Intelligent Instruments, Guilin University of Electronic Technology, Guilin 541004, PR China
1 shared publication - Zhencheng Chen
School of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin, 541004, PR China
1 shared publication
Latest Publications
- Open Access
- 25 March 2023
- Published by MDPI AG in Chemosensors
- Vol. 11 (4) , 209
A Facile Sensor for Detection of Lysozyme in Egg White Based on AuNPs and Ferrocene Dicarboxylic Acid
Lysozyme (Lyz) is found in animal and human bodily fluids, and is frequently utilized as a biomarker for various diseases. Even trace amounts of Lyz in food can potentially trigger adverse immune system reactions in sensitive individuals. Therefore, it is very important to monitor Lyz concentration in foods for safety. In this study, a simple and convenient electrochemical sensor for Lyz detection was prepared by modifying gold nanoparticles (AuNPs) and ferrocene dicarboxylic acid (Fc(COOH)2) on a glass carbon electrode (GCE), which was characterized fully by various electrochemical methods and field emission scanning electron microscope (FESEM). The proposed method utilized Fc(COOH)2 as a probe and AuNPs as an electron transfer medium to improve the sensor’s current response performance. Under optimal conditions, the sensor was used to detect Lyz with a linear range from 0.10~0.70 mmol·L−1 with a sensitivity of 50.55 μA·mM−1·cm−2, and a limit of detection (LOD) of 0.07 mmol·L−1. In the standard addition experiment of food samples (egg white), a total R.S.D. of less than 6.75% and an average recovery between 95.45% and 102.62% were obtained.
- 25 March 2023
- Published by MDPI AG in Chemosensors
- Vol. 11 (4) , 209
Open AccessA Facile Sensor for Detection of Lysozyme in Egg White Based on AuNPs and Ferrocene Dicarboxylic Acid
Lysozyme (Lyz) is found in animal and human bodily fluids, and is frequently utilized as a biomarker for various diseases. Even trace amounts of Lyz in food can potentially trigger adverse immune system reactions in sensitive individuals. Therefore, it is very important to monitor Lyz concentration in foods for safety. In this study, a simple and convenient electrochemical sensor for Lyz detection was prepared by modifying gold nanoparticles (AuNPs) and ferrocene dicarboxylic acid (Fc(COOH)2) on a glass carbon electrode (GCE), which was characterized fully by various electrochemical methods and field emission scanning electron microscope (FESEM). The proposed method utilized Fc(COOH)2 as a probe and AuNPs as an electron transfer medium to improve the sensor’s current response performance. Under optimal conditions, the sensor was used to detect Lyz with a linear range from 0.10~0.70 mmol·L−1 with a sensitivity of 50.55 μA·mM−1·cm−2, and a limit of detection (LOD) of 0.07 mmol·L−1. In the standard addition experiment of food samples (egg white), a total R.S.D. of less than 6.75% and an average recovery between 95.45% and 102.62% were obtained.
- Open Access
- 7 December 2021
- Published by MDPI AG in Micromachines
- Vol. 12 (12) , 1519
Convenient Heme Nanorod Modified Electrode for Quercetin Sensing by Two Common Electrochemical Methods
Quercetin (Qu) is one of the most abundant flavonoids in the human diet. High concentrations of Qu can easily cause adverse effects and induce inflammation, joint pain and stiffness. In this study, Heme was used as a sensitive element and deposited and formed nanorods on a glassy carbon electrode (GCE) for the detection of Qu. The Heme/GCE sensor was characterized using scanning electron microscopy (SEM), cyclic voltammetry (CV), differential pulse voltammetry (DPV) and electrochemical impedance spectroscopy (EIS) techniques. Under optimized conditions, the developed sensor presented a linear concentration ranging from 0.1 to 700 μmol·L−1 according to the CV and DPV methods. The detection limit for the sensor was 0.134 μmol·L−1 and its sensitivity was 0.12 μA·μM−1·cm−2, which were obtained from CV analysis. Through DPV analysis we obtained a detection limit of 0.063 μmol·L−1 and a sensitivity of 0.09 μA·μM−1·cm−2. Finally, this sensor was used to detect the Qu concentration in loquat leaf powder extract, with recovery between 98.55–102.89% and total R.S.D. lower than 3.70%. The constructed electrochemical sensor showed good anti-interference, repeatability and stability, indicating that it is also usable for the rapid detection of Qu in actual samples.
- 7 December 2021
- Published by MDPI AG in Micromachines
- Vol. 12 (12) , 1519
Open AccessConvenient Heme Nanorod Modified Electrode for Quercetin Sensing by Two Common Electrochemical Methods
Quercetin (Qu) is one of the most abundant flavonoids in the human diet. High concentrations of Qu can easily cause adverse effects and induce inflammation, joint pain and stiffness. In this study, Heme was used as a sensitive element and deposited and formed nanorods on a glassy carbon electrode (GCE) for the detection of Qu. The Heme/GCE sensor was characterized using scanning electron microscopy (SEM), cyclic voltammetry (CV), differential pulse voltammetry (DPV) and electrochemical impedance spectroscopy (EIS) techniques. Under optimized conditions, the developed sensor presented a linear concentration ranging from 0.1 to 700 μmol·L−1 according to the CV and DPV methods. The detection limit for the sensor was 0.134 μmol·L−1 and its sensitivity was 0.12 μA·μM−1·cm−2, which were obtained from CV analysis. Through DPV analysis we obtained a detection limit of 0.063 μmol·L−1 and a sensitivity of 0.09 μA·μM−1·cm−2. Finally, this sensor was used to detect the Qu concentration in loquat leaf powder extract, with recovery between 98.55–102.89% and total R.S.D. lower than 3.70%. The constructed electrochemical sensor showed good anti-interference, repeatability and stability, indicating that it is also usable for the rapid detection of Qu in actual samples.