Daniel Drebinger
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Daniel Drebinger has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- Anna Chorschew
Experimental and Clinical Research Center, Max Delbrück Center for Molecular Medicine, Charité – Universitätsmedizin Berlin, 13125 Berlin, Germany
3 shared publications - Friedemann Paul
Max Delbrück Centrum für Molekulare Medizin und Charité – Universitätsmedizin Berlin
3 shared publications - Max Emanuel Liebl
Charité – Universitätsmedizin Berlin, Arbeitsbereich Physikalische Medizin, Berlin, Deutschland
3 shared publications - Patrik Althoff
Experimental and Clinical Research Center, Max Delbrück Center for Molecular Medicine, Charité – Universitätsmedizin Berlin, 13125 Berlin, Germany
3 shared publications - Sina Cathérine Rosenkranz
Institute of Neuroimmunology and Multiple Sclerosis, University Medical Center Hamburg-Eppendorf Center for Molecular Neurobiology Hamburg, Hamburg, Germany
3 shared publications - Tanja Schmitz-Hübsch
Experimental and Clinical Research Center, a cooperation between Max Delbrueck Center (MDC) for Molecular Medicine in the Helmholtz Association, Charite - Universitaetsmedizin Berlin, Berlin, Germany
3 shared publications
Latest Publications
- 6 August 2026
- Published by Georg Thieme Verlag KG in Physikalische Medizin, Rehabilitationsmedizin, Kurortmedizin
Diaphragm Stretch-Relaxation Technique Reduces End-Expiratory Stiffness and Enhances Inspiration: Insights from Shear Wave Elastography
Manual therapy techniques aim to enhance respiratory function by reducing diaphragmatic tension. Clinicians often report a palpable softening of the diaphragm following treatment. However, it remains unclear whether this perceived change reflects an actual alteration in tissue properties or a subjective impression. Advances in ultrasound and shear wave elastography offer the potential to objectively quantify diaphragmatic elasticity.To assess diaphragmatic elasticity using ultrasonographic shear wave elastography before and after a brief diaphragm stretch to relax technique (D-SRT). Control group participants of a post-COVID-19 condition observational study with prior (>3 months), uncomplicated COVID-19 infection were exploratively assessed for elasticity and stiffness of the diaphragm. D-SRT is a therapeutically guided self-mobilization of the diaphragm with the aim of stretching it. Ultrasound with shear wave elastography was performed before and after diaphragm stretch-relax technique to release tension of the diaphragm All participants (n=14) performed a diaphragmatic stretch technique to relax the diaphragm. In the pre-post analysis, mean stiffness (2.02 m/s vs. 1.64 m/s, p<0.001) and mean elasticity (11.9 kPa vs. 7.5kPA, p<0.001) were lower at the end of expiration, while the elasticity and stiffness at the end of inspiration remained similar (3.07m/s vs. 2.97m/s, p=0.582; 28.3 kPa vs. 26.1 kPa, p=0.469). A short and simple manual diaphragmatic stretch-relax technique may reduce end-expiratory stiffness although confirmation in population without a history of COVID-19 is warranted. This may correspond to a temporarily softer and more elastic diaphragm, facilitating greater subsequent stiffness increases. The post-stretch reduction in end-expiratory stiffness may enhance the diaphragm’s physiological biomechanics – supported by its dome-shaped architecture – and improve contraction efficiency.
- 6 August 2026
- Published by Georg Thieme Verlag KG in Physikalische Medizin, Rehabilitationsmedizin, Kurortmedizin
Diaphragm Stretch-Relaxation Technique Reduces End-Expiratory Stiffness and Enhances Inspiration: Insights from Shear Wave Elastography
Manual therapy techniques aim to enhance respiratory function by reducing diaphragmatic tension. Clinicians often report a palpable softening of the diaphragm following treatment. However, it remains unclear whether this perceived change reflects an actual alteration in tissue properties or a subjective impression. Advances in ultrasound and shear wave elastography offer the potential to objectively quantify diaphragmatic elasticity.To assess diaphragmatic elasticity using ultrasonographic shear wave elastography before and after a brief diaphragm stretch to relax technique (D-SRT). Control group participants of a post-COVID-19 condition observational study with prior (>3 months), uncomplicated COVID-19 infection were exploratively assessed for elasticity and stiffness of the diaphragm. D-SRT is a therapeutically guided self-mobilization of the diaphragm with the aim of stretching it. Ultrasound with shear wave elastography was performed before and after diaphragm stretch-relax technique to release tension of the diaphragm All participants (n=14) performed a diaphragmatic stretch technique to relax the diaphragm. In the pre-post analysis, mean stiffness (2.02 m/s vs. 1.64 m/s, p<0.001) and mean elasticity (11.9 kPa vs. 7.5kPA, p<0.001) were lower at the end of expiration, while the elasticity and stiffness at the end of inspiration remained similar (3.07m/s vs. 2.97m/s, p=0.582; 28.3 kPa vs. 26.1 kPa, p=0.469). A short and simple manual diaphragmatic stretch-relax technique may reduce end-expiratory stiffness although confirmation in population without a history of COVID-19 is warranted. This may correspond to a temporarily softer and more elastic diaphragm, facilitating greater subsequent stiffness increases. The post-stretch reduction in end-expiratory stiffness may enhance the diaphragm’s physiological biomechanics – supported by its dome-shaped architecture – and improve contraction efficiency.
- 24 October 2025
- Published by Springer Nature in Deutsche Zeitschrift für Akupunktur
- Vol. 68 (4) , 237-238
Ein Tag auf TAO
- 24 October 2025
- Published by Springer Nature in Deutsche Zeitschrift für Akupunktur
- Vol. 68 (4) , 237-238
Ein Tag auf TAO
- 6 February 2025
- Published by Georg Thieme Verlag KG in Physikalische Medizin, Rehabilitationsmedizin, Kurortmedizin
- Vol. 36 (01) , 22-29
Post COVID-19 Condition Patients with Dyspnea Show Diaphragm Dysfunction in Sonographic Imaging – a Prospective Observational Study
Around 6.2% of patients report symptoms as fatigue, muscle pain and dyspnea more than three months after SARS-CoV-2 infection, defined as post COVID-19 condition (PCC). Non-hospitalized patients with PCC often show normal pulmonary functioning tests and imaging but suffer from respiratory symptoms. On clinical examination, PCC with dyspnea show signs of diaphragmatic dysfunction. The study aimed to objectively visualize and quantify the diaphragmatic function using sonographic parameters in PCC patients with and without dyspnea. Adult PCC patients were prospectively assessed for dysfunctional breathing and diaphragmatic stiffness using sonographic imaging. Multiparametric sonography evaluated diaphragm thickness, mobility, stiffness and elasticity in different breathing cycles using B-mode imaging, M-mode and quantitative shear wave elastography. PCC patients were stratified into two groups with and without dyspnea. Fifty-four post-COVID patients were assessed, of whom n=24 (44.4%) reported dyspnea and presented dysfunctional breathing, while 30 PCC without dyspnea served as control. PCC with dyspnea compared to PCC without dyspnea showed a less deep first breath (5.8 mm vs. 6.5 mm, p=0.044), reduced diaphragm thickness on inspiration (3.4 mm vs. 3.9 mm, p=0.030), as well as less increase of diaphragmatic elasticity (108% vs. 146%; p=0.027) and diaphragmatic stiffness (40% vs. 53%; p=0.022) during inspiration. Diaphragm dysfunction as a possible origin of dyspnea in PCC can be assessed and objectively quantified using multiparametric sonography and may help evaluate therapeutic interventions that are otherwise overlooked.
- 6 February 2025
- Published by Georg Thieme Verlag KG in Physikalische Medizin, Rehabilitationsmedizin, Kurortmedizin
- Vol. 36 (01) , 22-29
Post COVID-19 Condition Patients with Dyspnea Show Diaphragm Dysfunction in Sonographic Imaging – a Prospective Observational Study
Around 6.2% of patients report symptoms as fatigue, muscle pain and dyspnea more than three months after SARS-CoV-2 infection, defined as post COVID-19 condition (PCC). Non-hospitalized patients with PCC often show normal pulmonary functioning tests and imaging but suffer from respiratory symptoms. On clinical examination, PCC with dyspnea show signs of diaphragmatic dysfunction. The study aimed to objectively visualize and quantify the diaphragmatic function using sonographic parameters in PCC patients with and without dyspnea. Adult PCC patients were prospectively assessed for dysfunctional breathing and diaphragmatic stiffness using sonographic imaging. Multiparametric sonography evaluated diaphragm thickness, mobility, stiffness and elasticity in different breathing cycles using B-mode imaging, M-mode and quantitative shear wave elastography. PCC patients were stratified into two groups with and without dyspnea. Fifty-four post-COVID patients were assessed, of whom n=24 (44.4%) reported dyspnea and presented dysfunctional breathing, while 30 PCC without dyspnea served as control. PCC with dyspnea compared to PCC without dyspnea showed a less deep first breath (5.8 mm vs. 6.5 mm, p=0.044), reduced diaphragm thickness on inspiration (3.4 mm vs. 3.9 mm, p=0.030), as well as less increase of diaphragmatic elasticity (108% vs. 146%; p=0.027) and diaphragmatic stiffness (40% vs. 53%; p=0.022) during inspiration. Diaphragm dysfunction as a possible origin of dyspnea in PCC can be assessed and objectively quantified using multiparametric sonography and may help evaluate therapeutic interventions that are otherwise overlooked.
- Open Access
- 16 July 2024
- Published by Springer Nature in European Archives of Psychiatry and Clinical Neuroscience
- Vol. 274 (8) , 1993-2001
Functional outcome after interdisciplinary, acute rehabilitation in COVID-19 patients: a retrospective study
Background: Survivors of severe COVID-19 often exhibit a variety of sequelae including loss of mobility and ADL (activities of daily living) capacity. Acute rehabilitation (AR) is an interdisciplinary rehabilitation intervention applied early while still in a hospital setting. The goal of AR is to improve functional limitations and to increase functional independence at discharge. It is established in the treatment of patients with other severe diseases such as sepsis, polytrauma, or stroke. Data concerning AR in COVID-19 are sparse. Aim: To evaluate the changes in physical function during AR in patients after severe COVID-19. Methods: This monocentric, retrospective observational study examined the functional outcomes of a sample of COVID-19-patients who received interdisciplinary AR at a university hospital. Inclusion criteria were a positive SARS-CoV-2 test in 05/2020–01/2022 and transfer to AR after intensive care treatment. 87 patients were elegible for evaluation, 3 of whom were excluded because of death during AR. Data were extracted from the hospital information system. In a pre-post analysis, mobility (Charité Mobility Index), ADL (Barthel Index), and oxygen demand were assessed. In addition, discharge location after AR, factors associated with AR unit length of stay, and functional improvements were analyzed. Results: Data of 84 patients were analyzed. Mobility increased significantly from a median of 4 [1.25-6] CHARMI points at admission to a median of 9 [8.25-9] at discharge (p < 0.001). ADL increased significantly from a median of 52.5 [35.0-68.75] Barthel Index points at admission to a median of 92.5 [85–95] at discharge (p < 0.001). Oxygen demand decreased from 80.7 to 30.5% of patients. The majority (55.9%) of patients were discharged home, while 36.9% received direct follow-up rehabilitation. Older age correlated significantly with lower scores on the discharge assessment for mobility (Spearman’s ϱ = -0.285, p = 0.009) and ADL (Spearman’s ϱ = -0.297, p = 0.006). Conclusion: Acute rehabilitation is a viable option for COVID-19 patients with severe functional deficits after ICU treatment to achieve functional progress in mobility and ADL, reduce oxygen requirements and enable follow-up rehabilitation. Trial registration number and date of registration for prospectively registered trials: Trial registration number: DRKS00025239. Date of registration: 08 Sep 2021.
- 16 July 2024
- Published by Springer Nature in European Archives of Psychiatry and Clinical Neuroscience
- Vol. 274 (8) , 1993-2001
Open AccessFunctional outcome after interdisciplinary, acute rehabilitation in COVID-19 patients: a retrospective study
Background: Survivors of severe COVID-19 often exhibit a variety of sequelae including loss of mobility and ADL (activities of daily living) capacity. Acute rehabilitation (AR) is an interdisciplinary rehabilitation intervention applied early while still in a hospital setting. The goal of AR is to improve functional limitations and to increase functional independence at discharge. It is established in the treatment of patients with other severe diseases such as sepsis, polytrauma, or stroke. Data concerning AR in COVID-19 are sparse. Aim: To evaluate the changes in physical function during AR in patients after severe COVID-19. Methods: This monocentric, retrospective observational study examined the functional outcomes of a sample of COVID-19-patients who received interdisciplinary AR at a university hospital. Inclusion criteria were a positive SARS-CoV-2 test in 05/2020–01/2022 and transfer to AR after intensive care treatment. 87 patients were elegible for evaluation, 3 of whom were excluded because of death during AR. Data were extracted from the hospital information system. In a pre-post analysis, mobility (Charité Mobility Index), ADL (Barthel Index), and oxygen demand were assessed. In addition, discharge location after AR, factors associated with AR unit length of stay, and functional improvements were analyzed. Results: Data of 84 patients were analyzed. Mobility increased significantly from a median of 4 [1.25-6] CHARMI points at admission to a median of 9 [8.25-9] at discharge (p < 0.001). ADL increased significantly from a median of 52.5 [35.0-68.75] Barthel Index points at admission to a median of 92.5 [85–95] at discharge (p < 0.001). Oxygen demand decreased from 80.7 to 30.5% of patients. The majority (55.9%) of patients were discharged home, while 36.9% received direct follow-up rehabilitation. Older age correlated significantly with lower scores on the discharge assessment for mobility (Spearman’s ϱ = -0.285, p = 0.009) and ADL (Spearman’s ϱ = -0.297, p = 0.006). Conclusion: Acute rehabilitation is a viable option for COVID-19 patients with severe functional deficits after ICU treatment to achieve functional progress in mobility and ADL, reduce oxygen requirements and enable follow-up rehabilitation. Trial registration number and date of registration for prospectively registered trials: Trial registration number: DRKS00025239. Date of registration: 08 Sep 2021.
- Open Access
- 12 June 2024
- Published by Open Exploration Publishing
- Vol. 4, 273-287
Cognitive-motor interference in multiple sclerosis and healthy controls: results from single, dual, and triple task posturography
Aim: This article is based on our previous research, which was presented as a poster at the ECTRIMS Congress 2018 and published as a conference abstract (https://www.professionalabstracts.com/ectrims2018/iplanner/#/presentation/1698). Cognitive-motor interference (CMI) has been observed in both healthy controls (HC) and persons with multiple sclerosis (pwMS), but limited and contradictory data is making it difficult to assess the impact of motor and cognitive functioning levels on CMI. The aim of this study was to investigate CMI in pwMS and HC by means of a dual task postural paradigm, to compare them between groups and to analyse the influence of motor and cognitive functioning levels assessed with complementary instruments on observed CMI. Methods: The dual task posturography paradigm serves to quantify the impact of a cognitive (i.e., performing serial subtractions), a motor challenge (closing eyes), or both challenges combined (triple task) on body sway during standing in an upright position feet closed. The data analysed were acquired in one interventional and four observational studies and selected based on predefined criteria and by systematic quality control. A total of 113 pwMS and 42 HC were selected for analysis. Results: Comparable changes in motor and cognitive performance due to cognitive or combined cognitive-motor challenges were observed in both HC and pwMS. Combining both tasks did not result in further changes in motor performance but resulted in a decrease in cognitive performance. This reduction in cognitive performance with an additional motor challenge correlated with lower levels of cognitive and motor functioning in pwMS. Unexpectedly, an increase in body sway due to a cognitive or combined cognitive-motor challenges was primarily observed in pwMS and HC with better cognitive and motor functioning. Conclusions: The results suggest that dual-task effects are not disease-specific but rather reflect individually different adaptation strategies depending on the specific motor and cognitive functioning levels.
- 12 June 2024
- Published by Open Exploration Publishing
- Vol. 4, 273-287
Open AccessCognitive-motor interference in multiple sclerosis and healthy controls: results from single, dual, and triple task posturography
Aim: This article is based on our previous research, which was presented as a poster at the ECTRIMS Congress 2018 and published as a conference abstract (https://www.professionalabstracts.com/ectrims2018/iplanner/#/presentation/1698). Cognitive-motor interference (CMI) has been observed in both healthy controls (HC) and persons with multiple sclerosis (pwMS), but limited and contradictory data is making it difficult to assess the impact of motor and cognitive functioning levels on CMI. The aim of this study was to investigate CMI in pwMS and HC by means of a dual task postural paradigm, to compare them between groups and to analyse the influence of motor and cognitive functioning levels assessed with complementary instruments on observed CMI. Methods: The dual task posturography paradigm serves to quantify the impact of a cognitive (i.e., performing serial subtractions), a motor challenge (closing eyes), or both challenges combined (triple task) on body sway during standing in an upright position feet closed. The data analysed were acquired in one interventional and four observational studies and selected based on predefined criteria and by systematic quality control. A total of 113 pwMS and 42 HC were selected for analysis. Results: Comparable changes in motor and cognitive performance due to cognitive or combined cognitive-motor challenges were observed in both HC and pwMS. Combining both tasks did not result in further changes in motor performance but resulted in a decrease in cognitive performance. This reduction in cognitive performance with an additional motor challenge correlated with lower levels of cognitive and motor functioning in pwMS. Unexpectedly, an increase in body sway due to a cognitive or combined cognitive-motor challenges was primarily observed in pwMS and HC with better cognitive and motor functioning. Conclusions: The results suggest that dual-task effects are not disease-specific but rather reflect individually different adaptation strategies depending on the specific motor and cognitive functioning levels.
- 21 September 2023
- Published by Springer Nature in Deutsche Zeitschrift für Akupunktur
- Vol. 66 (4) , 219-221
Mit 10 Punkten zur Schmerzfreiheit bei akuter Lumbago
- 21 September 2023
- Published by Springer Nature in Deutsche Zeitschrift für Akupunktur
- Vol. 66 (4) , 219-221
Mit 10 Punkten zur Schmerzfreiheit bei akuter Lumbago
- Open Access
- 1 April 2022
- Published by JMIR Publications Inc. in JMIR Human Factors
- Vol. 9 (2) , e26825
Proposal for Post Hoc Quality Control in Instrumented Motion Analysis Using Markerless Motion Capture: Development and Usability Study
Background: Instrumented assessment of motor symptoms has emerged as a promising extension to the clinical assessment of several movement disorders. The use of mobile and inexpensive technologies such as some markerless motion capture technologies is especially promising for large-scale application but has not transitioned into clinical routine to date. A crucial step on this path is to implement standardized, clinically applicable tools that identify and control for quality concerns. Objective: The main goal of this study comprises the development of a systematic quality control (QC) procedure for data collected with markerless motion capture technology and its experimental implementation to identify specific quality concerns and thereby rate the usability of recordings. Methods: We developed a post hoc QC pipeline that was evaluated using a large set of short motor task recordings of healthy controls (2010 recordings from 162 subjects) and people with multiple sclerosis (2682 recordings from 187 subjects). For each of these recordings, 2 raters independently applied the pipeline. They provided overall usability decisions and identified technical and performance-related quality concerns, which yielded respective proportions of their occurrence as a main result. Results: The approach developed here has proven user-friendly and applicable on a large scale. Raters’ decisions on recording usability were concordant in 71.5%-92.3% of cases, depending on the motor task. Furthermore, 39.6%-85.1% of recordings were concordantly rated as being of satisfactory quality whereas in 5.0%-26.3%, both raters agreed to discard the recording. Conclusions: We present a QC pipeline that seems feasible and useful for instant quality screening in the clinical setting. Results confirm the need of QC despite using standard test setups, testing protocols, and operator training for the employed system and by extension, for other task-based motor assessment technologies. Results of the QC process can be used to clean existing data sets, optimize quality assurance measures, as well as foster the development of automated QC approaches and therefore improve the overall reliability of kinematic data sets.
- 1 April 2022
- Published by JMIR Publications Inc. in JMIR Human Factors
- Vol. 9 (2) , e26825
Open AccessProposal for Post Hoc Quality Control in Instrumented Motion Analysis Using Markerless Motion Capture: Development and Usability Study
Background: Instrumented assessment of motor symptoms has emerged as a promising extension to the clinical assessment of several movement disorders. The use of mobile and inexpensive technologies such as some markerless motion capture technologies is especially promising for large-scale application but has not transitioned into clinical routine to date. A crucial step on this path is to implement standardized, clinically applicable tools that identify and control for quality concerns. Objective: The main goal of this study comprises the development of a systematic quality control (QC) procedure for data collected with markerless motion capture technology and its experimental implementation to identify specific quality concerns and thereby rate the usability of recordings. Methods: We developed a post hoc QC pipeline that was evaluated using a large set of short motor task recordings of healthy controls (2010 recordings from 162 subjects) and people with multiple sclerosis (2682 recordings from 187 subjects). For each of these recordings, 2 raters independently applied the pipeline. They provided overall usability decisions and identified technical and performance-related quality concerns, which yielded respective proportions of their occurrence as a main result. Results: The approach developed here has proven user-friendly and applicable on a large scale. Raters’ decisions on recording usability were concordant in 71.5%-92.3% of cases, depending on the motor task. Furthermore, 39.6%-85.1% of recordings were concordantly rated as being of satisfactory quality whereas in 5.0%-26.3%, both raters agreed to discard the recording. Conclusions: We present a QC pipeline that seems feasible and useful for instant quality screening in the clinical setting. Results confirm the need of QC despite using standard test setups, testing protocols, and operator training for the employed system and by extension, for other task-based motor assessment technologies. Results of the QC process can be used to clean existing data sets, optimize quality assurance measures, as well as foster the development of automated QC approaches and therefore improve the overall reliability of kinematic data sets.
- Open Access
- 29 December 2020
- Published by JMIR Publications Inc. in JMIR Preprints
Proposal for Post Hoc Quality Control in Instrumented Motion Analysis Using Markerless Motion Capture: Development and Usability Study (Preprint)
Journal of Medical Internet Research - International Scientific Journal for Medical Research, Information and Communication on the Internet #Preprint #PeerReviewMe: Warning: This is a unreviewed preprint. Readers are warned that the document has not been peer-reviewed by expert/patient reviewers or an academic editor, may contain misleading claims, and is likely to undergo changes before final publication, if accepted, or may have been rejected/withdrawn. Readers with interest and expertise are encouraged to sign up as peer-reviewer, if the paper is within an open peer-review period. Please cite this preprint only for review purposes or for grant applications and CVs (if you are the author). Background: Instrumented assessment of motor symptoms has emerged as a promising extension to the clinical assessment of several movement disorders. The use of mobile and inexpensive technologies such as some markerless motion capture technologies is especially promising for large-scale application but has not transitioned into clinical routine to date. A crucial step on this path is to implement standardized, clinically applicable tools that identify and control for quality concerns. Objective: The main goal of this study comprises the development of a systematic quality control (QC) procedure for data collected with markerless motion capture technology and its experimental implementation to identify specific quality concerns and thereby rate the usability of recordings. Methods: We developed a post hoc QC pipeline that was evaluated using a large set of short motor task recordings of healthy controls (2010 recordings from 162 subjects) and people with multiple sclerosis (2682 recordings from 187 subjects). For each of these recordings, 2 raters independently applied the pipeline. They provided overall usability decisions and identified technical and performance-related quality concerns, which yielded respective proportions of their occurrence as a main result. Results: The approach developed here has proven user-friendly and applicable on a large scale. Raters’ decisions on recording usability were concordant in 71.5%-92.3% of cases, depending on the motor task. Furthermore, 39.6%-85.1% of recordings were concordantly rated as being of satisfactory quality whereas in 5.0%-26.3%, both raters agreed to discard the recording. Conclusions: We present a QC pipeline that seems feasible and useful for instant quality screening in the clinical setting. Results confirm the need of QC despite using standard test setups, testing protocols, and operator training for the employed system and by extension, for other task-based motor assessment technologies. Results of the QC process can be used to clean existing data sets, optimize quality assurance measures, as well as foster the development of automated QC approaches and therefore improve the overall reliability of kinematic data sets.
- 29 December 2020
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessProposal for Post Hoc Quality Control in Instrumented Motion Analysis Using Markerless Motion Capture: Development and Usability Study (Preprint)
Journal of Medical Internet Research - International Scientific Journal for Medical Research, Information and Communication on the Internet #Preprint #PeerReviewMe: Warning: This is a unreviewed preprint. Readers are warned that the document has not been peer-reviewed by expert/patient reviewers or an academic editor, may contain misleading claims, and is likely to undergo changes before final publication, if accepted, or may have been rejected/withdrawn. Readers with interest and expertise are encouraged to sign up as peer-reviewer, if the paper is within an open peer-review period. Please cite this preprint only for review purposes or for grant applications and CVs (if you are the author). Background: Instrumented assessment of motor symptoms has emerged as a promising extension to the clinical assessment of several movement disorders. The use of mobile and inexpensive technologies such as some markerless motion capture technologies is especially promising for large-scale application but has not transitioned into clinical routine to date. A crucial step on this path is to implement standardized, clinically applicable tools that identify and control for quality concerns. Objective: The main goal of this study comprises the development of a systematic quality control (QC) procedure for data collected with markerless motion capture technology and its experimental implementation to identify specific quality concerns and thereby rate the usability of recordings. Methods: We developed a post hoc QC pipeline that was evaluated using a large set of short motor task recordings of healthy controls (2010 recordings from 162 subjects) and people with multiple sclerosis (2682 recordings from 187 subjects). For each of these recordings, 2 raters independently applied the pipeline. They provided overall usability decisions and identified technical and performance-related quality concerns, which yielded respective proportions of their occurrence as a main result. Results: The approach developed here has proven user-friendly and applicable on a large scale. Raters’ decisions on recording usability were concordant in 71.5%-92.3% of cases, depending on the motor task. Furthermore, 39.6%-85.1% of recordings were concordantly rated as being of satisfactory quality whereas in 5.0%-26.3%, both raters agreed to discard the recording. Conclusions: We present a QC pipeline that seems feasible and useful for instant quality screening in the clinical setting. Results confirm the need of QC despite using standard test setups, testing protocols, and operator training for the employed system and by extension, for other task-based motor assessment technologies. Results of the QC process can be used to clean existing data sets, optimize quality assurance measures, as well as foster the development of automated QC approaches and therefore improve the overall reliability of kinematic data sets.