INIgor M. Narozhnyy

Igor M. Narozhnyy

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Igor M. Narozhnyy has a total of 18 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Thermodynamics and Electrochemistry of the Interaction of Sphalerite with Iron (II)-Bearing Compounds in Relation to Flotation

    by Kyaw Zay Ya, Boris Goryachev, Arkadiy Adigamov, Karina Nurgalieva, Igor Narozhnyy

    The flotation recovery of sphalerite depends on the inorganic reagents concentrations in the liquid phase of suspension and pH. This paper presents the results of studies of the interactions of iron (II) containing ions with the sphalerite surface in water solutions at different pH levels. The thermodynamic and electrochemical studies were carried out to analyze possible interactions of sphalerite with iron (II) sulfate in a water environment and relate them to sphalerite flotation with potassium butyl xanthate and sodium dibutyl dithiophosphate. The results of the thermodynamic calculations revealed the possibility of interaction of the sphalerite surface with iron (II) hydrolysis products. The effect of the hydroxide ions concentration on precipitation of iron (II) hydroxides was examined. The findings showed that at pH = 8 there were no precipitates observed in water solutions of FeSO4. Increasing pH of the solutions from 8 to 12 resulted in the formation of iron (II) hydroxides. The potentiometric studies revealed that in slightly alkaline solutions the Fe2+ and FeOH+ cations are potential-determining. In conclusion, the flotation tests with thiol collectors show the activation effect of iron (II) sulphate on sphalerite at low dosage and pH 12. This is evident by a higher flotation recovery of sphalerite at these conditions.


  • Open Access

    Application of Neural Network and Dual-Energy Radiation-Based Detection Techniques to Measure Scale Layer Thickness in Oil Pipelines Containing a Stratified Regime of Three-Phase Flow

    by Abdulilah Mohammad Mayet, Tzu-Chia Chen, Ijaz Ahmad, Elsayed Tag Eldin, Ali Awadh Al-Qahtani, Igor M. Narozhnyy, John William Grimaldo Guerrero, Hala H. Alhashim

    Over time, oil pipes are scaled, which causes problems such as a reduction in the effective diameter of the oil pipe, an efficiency reduction, waste of energy, etc. Determining the exact value of the scale inside the pipe is very important in order to take timely action and to prevent the mentioned problems. One accurate detection methodology is the use of non-invasive systems based on gamma-ray attenuation. For this purpose, in this research, a scale thickness detection system consisting of a test pipe, a dual-energy gamma source (241Am and 133Ba radioisotopes), and two sodium iodide detectors were simulated using the Monte Carlo N Particle (MCNP) code. In the test pipe, three-phase flow consisting of water, gas, and oil was simulated in a stratified flow regime in volume percentages in the range from 10% to 80%. In addition, a scale with different thicknesses from 0 to 3 cm was placed inside the pipe, and gamma rays were irradiated onto the pipe; on the other side of the pipe, the photon intensity was recorded by the detectors. A total of 252 simulations were performed. From the signal received by the detectors, four characteristics were extracted, named the Photopeaks of 241Am and 133Ba for the first and second detectors. After training many different Multi-Layer Perceptron(MLP) neural networks with various architectures, it was found that a structure with two hidden layers could predict the connection between the input, extracted features, and the output, scale thickness, with a Root Mean Square Error (RMSE) of less than 0.06. This low error value guarantees the effectiveness of the proposed method and the usefulness of this method for the oil and petrochemical industry.


  • Open Access

    Proposing a High-Precision Petroleum Pipeline Monitoring System for Identifying the Type and Amount of Oil Products Using Extraction of Frequency Characteristics and a MLP Neural Network

    by Abdulilah Mohammad Mayet, Karina Shamilyevna Nurgalieva, Ali Awadh Al-Qahtani, Igor M. Narozhnyy, Hala H. Alhashim, Ehsan Nazemi, Ilya M. Indrupskiy

    Setting up pipelines in the oil industry is very costly and time consuming. For this reason, a pipe is usually used to transport various petroleum products, so it is very important to use an accurate and reliable control system to determine the type and amount of oil product. In this research, using a system based on the gamma-ray attenuation technique and the feature extraction technique in the frequency domain combined with a Multilayer Perceptron (MLP) neural network, an attempt has been made to determine the type and amount of four petroleum products. The implemented system consists of a dual-energy gamma source, a test pipe to simulate petroleum products, and a sodium iodide detector. The signals received from the detector were transmitted to the frequency domain, and the amplitudes of the first to fourth dominant frequency were extracted from them. These characteristics were given to an MLP neural network as input. The designed neural network has four outputs, which is the percentage of the volume ratio of each product. The proposed system has the ability to predict the volume ratio of products with a maximum root mean square error (RMSE) of 0.69, which is a strong reason for the use of this system in the oil industry.


  • Open Access

    Extraction of Time-Domain Characteristics and Selection of Effective Features Using Correlation Analysis to Increase the Accuracy of Petroleum Fluid Monitoring Systems

    by Abdulilah Mohammad Mayet, Seyed Mehdi Alizadeh, Karina Shamilyevna Nurgalieva, Robert Hanus, Ehsan Nazemi, Igor M. Narozhnyy

    In the current paper, a novel technique is represented to control the liquid petrochemical and petroleum products passing through a transmitting pipe. A simulation setup, including an X-ray tube, a detector, and a pipe, was conducted by Monte Carlo N Particle-X version (MCNPX) code to examine a two-by-two mixture of four diverse petroleum products (ethylene glycol, crude oil, gasoline, and gasoil) in various volumetric ratios. As the feature extraction system, twelve time characteristics were extracted from the received signal, and the most effective ones were selected using correlation analysis to present reasonable inputs for neural network training. Three Multilayers perceptron (MLP) neural networks were applied to indicate the volume ratio of three kinds of petroleum products, and the volume ratio of the fourth product can be feasibly achieved through the results of the three aforementioned networks. In this study, increasing accuracy was placed on the agenda, and an RMSE < 1.21 indicates this high accuracy. Increasing the accuracy of predicting volume ratio, which is due to the use of appropriate characteristics as the neural network input, is the most important innovation in this study, which is why the proposed system can be used as an efficient method in the oil industry.


  • Open Access

    Application of Neural Network and Time-Domain Feature Extraction Techniques for Determining Volumetric Percentages and the Type of Two Phase Flow Regimes Independent of Scale Layer Thickness

    by Abdullah K. Alanazi, Seyed Mehdi Alizadeh, Karina Shamilyevna Nurgalieva, Slavko Nesic, John William Grimaldo Guerrero, Hala M. Abo-Dief, Ehsan Eftekhari-Zadeh, Ehsan Nazemi, Igor M. Narozhnyy

    One of the factors that significantly affects the efficiency of oil and gas industry equipment is the scales formed in the pipelines. In this innovative, non-invasive system, the inclusion of a dual-energy gamma source and two sodium iodide detectors was investigated with the help of artificial intelligence to determine the flow pattern and volume percentage in a two-phase flow by considering the thickness of the scale in the tested pipeline. In the proposed structure, a dual-energy gamma source consisting of barium-133 and cesium-137 isotopes emit photons, one detector recorded transmitted photons and a second detector recorded the scattered photons. After simulating the mentioned structure using Monte Carlo N-Particle (MCNP) code, time characteristics named 4th order moment, kurtosis and skewness were extracted from the recorded data of both the transmission detector (TD) and scattering detector (SD). These characteristics were considered as inputs of the multilayer perceptron (MLP) neural network. Two neural networks that were able to determine volume percentages with high accuracy, as well as classify all flow regimes correctly, were trained.


  • Open Access

    Optimization of X-ray Tube Voltage to Improve the Precision of Two Phase Flow Meters Used in Petroleum Industry

    by Abdullah K. Alanazi, Seyed Mehdi Alizadeh, Karina Shamilyevna Nurgalieva, John William Grimaldo Guerrero, Hala M. Abo-Dief, Ehsan Eftekhari-Zadeh, Ehsan Nazemi, Igor M. Narozhnyy

    To the best knowledge of the authors, in all the former studies, a fixed value of X-ray tube voltage has been used for investigating gas–liquid two-phase flow characteristics, while the energy of emitted X-ray radiations that depends on the tube voltage can significantly affect the measurement precision of the system. The purpose of present study is to find the optimum tube voltage to increase the accuracy and efficiency of an intelligent X-ray radiation-based two-phase flow meter. The detection system consists of an industrial X-ray tube and one detector located on either side of a steel pipe. Tube voltages in the range of 125–300 kV with a step of 25 kV were investigated. For each tube voltage, different gas volume percentages (GVPs) in the range of 10–90% with a step of 5% were modeled. A feature extraction method was performed on the output signals of the detector in every case, and the obtained matrixes were applied to the designed radial basis function neural networks (RBFNNs). The desired output of the networks was GVP. The precision of the networks in every voltage and every number of neurons in the hidden layer were obtained. The results showed that 225 kV tube voltage is the optimum voltage for this purpose. The obtained mean absolute error (MAE) for this case is less than 0.05, which demonstrates the very high precision of the metering system with an optimum X-ray tube voltage.