PWPeng Wang

Peng Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Peng Wang has a total of 7 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Random Error Suppression Method Based on IGWPSO-ELM for Micromachined Silicon Resonant Accelerometers

    by Peng Wang, Libin Huang, Peng Wang, Liye Zhao, Xukai Ding

    There are various errors in practical applications of micromachined silicon resonant accelerometers (MSRA), among which the composition of random errors is complex and uncertain. In order to improve the output accuracy of MSRA, this paper proposes an MSRA random error suppression method based on an improved grey wolf and particle swarm optimized extreme learning machine (IGWPSO-ELM). A modified wavelet threshold function is firstly used to separate the white noise from the useful signal. The output frequency at the previous sampling point and the sequence value are then added to the current output frequency to form a three-dimensional input. Additional improvements are made on the particle swarm optimized extreme learning machine (PSO-ELM): the grey wolf optimization (GWO) is fused into the algorithm and the three factors (inertia, acceleration and convergence) are non-linearized to improve the convergence efficiency and accuracy of the algorithm. The model trained offline using IGWPSO-ELM is applied to predicting compensation experiments, and the results show that the method is able to reduce velocity random walk from the original 4.3618 μg/√Hz to 2.1807 μg/√Hz, bias instability from the original 2.0248 μg to 1.3815 μg, and acceleration random walk from the original 0.53429 μg·√Hz to 0.43804 μg·√Hz, effectively suppressing the random error in the MSRA output.


  • Open Access

    Enhancing the Shock Response Performance of Micromachined Silicon Resonant Accelerometers by Electrostatic Active Damping Control

    by Libin Huang, Kai Jiang, Peng Wang, Meimei Zhang, Xukai Ding, Hongsheng Li

    This paper presents a micromachined silicon resonant accelerometer based on electrostatic active damping control, which can improve the shock response performance of the accelerometer. In the accelerometer, an electrostatic active damping structure and damping control circuit are designed to improve the equivalent damping coefficient of the system. System-level Simulink modeling and simulation of the accelerometer with an electrostatic active damping closed-loop control link were carried out. The simulation results indicate that the system can quickly return to normal output without an obvious vibration process after the shock. The fabricated and packaged accelerometer was connected to an external test circuit for shock performance testing. The stabilization time of the accelerometer after a 100 g, 3–5 ms half-sine shock was reduced from 19.8 to 5.6 s through use of the damping control. Furthermore, the change in deviation before and after the shock without damping control was 0.8197 mg, whereas it was 0.1715 mg with damping control. The experimental results demonstrate that the electrostatic active damping control can effectively improve the dynamic performance of the micromachined silicon resonant accelerometer.