Meimei Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Meimei Zhang has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Libin Huang
School of Instrument Science and Engineering, Southeast University, Nanjing 210096, China
2 shared publications - Xukai Ding
School of Instrument Science and Engineering, Southeast University, Nanjing, China
2 shared publications - Hongsheng Li
School of Instrument Science and Engineering and the Key Laboratory of Micro-lnertial Instrument and Advanced Navigation Technology, Ministry of Education, Southeast University, Nanjing, China
1 shared publication - Kai Jiang
School of Instrument Science and Engineering, Southeast University, Nanjing 210096, China
1 shared publication - Liye Zhao
School of Instrument Science and Engineering, Southeast University, Nanjing, China
1 shared publication - Peng Wang
School of Instrument Science and Engineering, Southeast University, Nanjing 210096, China
1 shared publication
Latest Publications
- Open Access
- 28 December 2021
- Published by MDPI AG in Micromachines
- Vol. 13 (1) , 38
Structural Design and Optimization of a Resonant Micro-Accelerometer Based on Electrostatic Stiffness by an Improved Differential Evolution Algorithm
This study designed an in-plane resonant micro-accelerometer based on electrostatic stiffness. The accelerometer adopts a one-piece proof mass structure; two double-folded beam resonators are symmetrically distributed inside the proof mass, and only one displacement is introduced under the action of acceleration, which reduces the influence of processing errors on the performance of the accelerometer. The two resonators form a differential structure that can diminish the impact of common-mode errors. This accelerometer realizes the separation of the introduction of electrostatic stiffness and the detection of resonant frequency, which is conducive to the decoupling of accelerometer signals. An improved differential evolution algorithm was developed to optimize the scale factor of the accelerometer. Through the final elimination principle, excellent individuals are preserved, and the most suitable parameters are allocated to the surviving individuals to stimulate the offspring to find the globally optimal ability. The algorithm not only maintains the global optimality but also reduces the computational complexity of the algorithm and deterministically realizes the optimization of the accelerometer scale factor. The electrostatic stiffness resonant micro-accelerometer was fabricated by deep dry silicon-on-glass (DDSOG) technology. The unloaded resonant frequency of the accelerometer resonant beam was between 24 and 26 kHz, and the scale factor of the packaged accelerometer was between 54 and 59 Hz/g. The average error between the optimization result and the actual scale factor was 7.03%. The experimental results verified the rationality of the structural design.
- 28 December 2021
- Published by MDPI AG in Micromachines
- Vol. 13 (1) , 38
Open AccessStructural Design and Optimization of a Resonant Micro-Accelerometer Based on Electrostatic Stiffness by an Improved Differential Evolution Algorithm
This study designed an in-plane resonant micro-accelerometer based on electrostatic stiffness. The accelerometer adopts a one-piece proof mass structure; two double-folded beam resonators are symmetrically distributed inside the proof mass, and only one displacement is introduced under the action of acceleration, which reduces the influence of processing errors on the performance of the accelerometer. The two resonators form a differential structure that can diminish the impact of common-mode errors. This accelerometer realizes the separation of the introduction of electrostatic stiffness and the detection of resonant frequency, which is conducive to the decoupling of accelerometer signals. An improved differential evolution algorithm was developed to optimize the scale factor of the accelerometer. Through the final elimination principle, excellent individuals are preserved, and the most suitable parameters are allocated to the surviving individuals to stimulate the offspring to find the globally optimal ability. The algorithm not only maintains the global optimality but also reduces the computational complexity of the algorithm and deterministically realizes the optimization of the accelerometer scale factor. The electrostatic stiffness resonant micro-accelerometer was fabricated by deep dry silicon-on-glass (DDSOG) technology. The unloaded resonant frequency of the accelerometer resonant beam was between 24 and 26 kHz, and the scale factor of the packaged accelerometer was between 54 and 59 Hz/g. The average error between the optimization result and the actual scale factor was 7.03%. The experimental results verified the rationality of the structural design.
- Open Access
- 12 December 2021
- Published by MDPI AG in Micromachines
- Vol. 12 (12) , 1548
Enhancing the Shock Response Performance of Micromachined Silicon Resonant Accelerometers by Electrostatic Active Damping Control
This paper presents a micromachined silicon resonant accelerometer based on electrostatic active damping control, which can improve the shock response performance of the accelerometer. In the accelerometer, an electrostatic active damping structure and damping control circuit are designed to improve the equivalent damping coefficient of the system. System-level Simulink modeling and simulation of the accelerometer with an electrostatic active damping closed-loop control link were carried out. The simulation results indicate that the system can quickly return to normal output without an obvious vibration process after the shock. The fabricated and packaged accelerometer was connected to an external test circuit for shock performance testing. The stabilization time of the accelerometer after a 100 g, 3–5 ms half-sine shock was reduced from 19.8 to 5.6 s through use of the damping control. Furthermore, the change in deviation before and after the shock without damping control was 0.8197 mg, whereas it was 0.1715 mg with damping control. The experimental results demonstrate that the electrostatic active damping control can effectively improve the dynamic performance of the micromachined silicon resonant accelerometer.
- 12 December 2021
- Published by MDPI AG in Micromachines
- Vol. 12 (12) , 1548
Open AccessEnhancing the Shock Response Performance of Micromachined Silicon Resonant Accelerometers by Electrostatic Active Damping Control
This paper presents a micromachined silicon resonant accelerometer based on electrostatic active damping control, which can improve the shock response performance of the accelerometer. In the accelerometer, an electrostatic active damping structure and damping control circuit are designed to improve the equivalent damping coefficient of the system. System-level Simulink modeling and simulation of the accelerometer with an electrostatic active damping closed-loop control link were carried out. The simulation results indicate that the system can quickly return to normal output without an obvious vibration process after the shock. The fabricated and packaged accelerometer was connected to an external test circuit for shock performance testing. The stabilization time of the accelerometer after a 100 g, 3–5 ms half-sine shock was reduced from 19.8 to 5.6 s through use of the damping control. Furthermore, the change in deviation before and after the shock without damping control was 0.8197 mg, whereas it was 0.1715 mg with damping control. The experimental results demonstrate that the electrostatic active damping control can effectively improve the dynamic performance of the micromachined silicon resonant accelerometer.