Guorong Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Guorong Li has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Xiangyu Meng
School of Electrical Engineering, Southwest Jiaotong University, Chengdu, China
2 shared publications - Zhigang Liu
Southwest Jiaotong University
2 shared publications - Heng Zhou
School of Electrical Engineering, Southwest Jiaotong University, Chengdu, China
1 shared publication - Jiawei Liu
State Grid Sichuan Economic Research Institute, Chengdu 610041, China
1 shared publication - Keting Hu
School of Electrical Engineering, Southwest Jiaotong University, Chengdu, China
1 shared publication - Siqi Wu
School of Electrical Engineering, Southwest Jiaotong University, Chengdu, China
1 shared publication
Latest Publications
- 7 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 8 (3) , 3848-3858
A Multi-Frequency Input-Admittance Model of Locomotive Rectifier Considering PWM Sideband Harmonic Coupling in Electrical Railways
Electrical railway harmonic instability issues are common in the high-frequency range. The effective frequency of the traditional converter’s small-signal averaging model is below 1/2 switching frequency since the pulse width modulation (PWM) sideband harmonic components are ignored. In this article, the dynamic propagations of perturbation frequency and the generated PWM sideband components are constructed first. Then the locomotive rectifier’s multi-frequency input-admittance model is derived appropriately. Afterward, an admittance conversion approach is used to convert the multi-frequency model into the single-input–single-output (SISO) model whereas retaining the sideband frequency couplings. The proposed SISO model is more accurate than the traditional small-signal averaging model in the frequency range higher than 1/2 switching frequency. It is found that PWM sideband harmonics dominate the locomotive rectifier’s input-admittance characteristic higher than 1/2 switching frequency. Finally, based on the proposed model, the influence of different switching frequencies, control bandwidths, and traction network impedance on system harmonic stability is revealed by the hardware-in-the-loop (HIL) results.
- 7 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 8 (3) , 3848-3858
A Multi-Frequency Input-Admittance Model of Locomotive Rectifier Considering PWM Sideband Harmonic Coupling in Electrical Railways
Electrical railway harmonic instability issues are common in the high-frequency range. The effective frequency of the traditional converter’s small-signal averaging model is below 1/2 switching frequency since the pulse width modulation (PWM) sideband harmonic components are ignored. In this article, the dynamic propagations of perturbation frequency and the generated PWM sideband components are constructed first. Then the locomotive rectifier’s multi-frequency input-admittance model is derived appropriately. Afterward, an admittance conversion approach is used to convert the multi-frequency model into the single-input–single-output (SISO) model whereas retaining the sideband frequency couplings. The proposed SISO model is more accurate than the traditional small-signal averaging model in the frequency range higher than 1/2 switching frequency. It is found that PWM sideband harmonics dominate the locomotive rectifier’s input-admittance characteristic higher than 1/2 switching frequency. Finally, based on the proposed model, the influence of different switching frequencies, control bandwidths, and traction network impedance on system harmonic stability is revealed by the hardware-in-the-loop (HIL) results.
- 14 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Vehicular Technology
- Vol. 71 (2) , 1372-1383
A Multi-Frequency DQ Impedance Measurement Algorithm for Single-Phase Vehicle-Grid System in Electrified Railways
Dq impedance measurement is of great importance as a part of the impedance-based analysis. At present, impedance of objects in single-phase vehicle-grid system are mainly obtained by injecting the voltage or current disturbance of one single frequency into the system circularly. However, as the number of measurement frequency points increases, there will produce much time-consuming of measurement. In this paper, a quick dq impedance measurement algorithm for single-phase vehicle-grid system based on multi-frequency sweep is proposed. First, pseudo-random binary sequences (PRBS) and ternary sequences are modified as the driving signals rather than directly injecting into the control link. Then three types of disturbance with specific frequency characteristics are introduced into the system and their parameters setting principle are given for the first time. According to the different characteristics of measurement objects, the proposed algorithms are also different to ensure the maximum specificity and sensitivity. Finally, for different objects in vehicle-grid system like traction network, single-phase converter and dual-interleaved converter, simulation and experimental results based on the hardware in the loop real-time simulation platform both show the correctness of the proposed algorithm, and the possible causes of errors are also analyzed in detail. Moreover, the proposed algorithm makes it possible to quickly measure the dq impedance of the single-phase vehicle-grid system, and the correctness of the theoretical and measured value can be judged and used for the stability analysis of electrical systems.
- 14 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Vehicular Technology
- Vol. 71 (2) , 1372-1383
A Multi-Frequency DQ Impedance Measurement Algorithm for Single-Phase Vehicle-Grid System in Electrified Railways
Dq impedance measurement is of great importance as a part of the impedance-based analysis. At present, impedance of objects in single-phase vehicle-grid system are mainly obtained by injecting the voltage or current disturbance of one single frequency into the system circularly. However, as the number of measurement frequency points increases, there will produce much time-consuming of measurement. In this paper, a quick dq impedance measurement algorithm for single-phase vehicle-grid system based on multi-frequency sweep is proposed. First, pseudo-random binary sequences (PRBS) and ternary sequences are modified as the driving signals rather than directly injecting into the control link. Then three types of disturbance with specific frequency characteristics are introduced into the system and their parameters setting principle are given for the first time. According to the different characteristics of measurement objects, the proposed algorithms are also different to ensure the maximum specificity and sensitivity. Finally, for different objects in vehicle-grid system like traction network, single-phase converter and dual-interleaved converter, simulation and experimental results based on the hardware in the loop real-time simulation platform both show the correctness of the proposed algorithm, and the possible causes of errors are also analyzed in detail. Moreover, the proposed algorithm makes it possible to quickly measure the dq impedance of the single-phase vehicle-grid system, and the correctness of the theoretical and measured value can be judged and used for the stability analysis of electrical systems.