Tatsuhiro Horii
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Tatsuhiro Horii has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Toshinori Fujie
School of Life Science and Technology, Institute of Science Tokyo, B-50, 4259 Nagatsuta-cho, Midori-ku, Yokohama 226-8501, Japan
4 shared publications - Shingo Maeda
Institute of Science Tokyo, Tokyo, Japan
2 shared publications - Ai Ueno
Department of Mechanical Systems Engineering, Graduate School of Engineering Nagoya University Nagoya Aichi Japan
1 shared publication Aoi Koishikawa
Department of Mechanical Engineering Yokohama National University Yokohama Kanagawa Japan
1 shared publication- Ardi Wiranata
Department of Mechanical and Industrial Engineering Universitas Gadjah Mada Yogyakarta Indonesia
1 shared publication - Daishi Shiojiri
Kanagawa Institute of Industrial Science and Technology, Ebina, Kanagawa 243-0435, Japan
1 shared publication
Latest Publications
- Open Access
- 2 February 2026
- Published by Wiley in Advanced Functional Materials
- Vol. 36 (36)
Nanolayer‐Encapsulated Stretchable Liquid‐Metal Sheets for Thermal Management
Efficient thermal management in stretchable electronics demands materials that seamlessly integrate high thermal conductivity, mechanical flexibility, and reliable interface stability. This paper presents a stretchable, thermally conductive, biphasic, liquid‐metal sheet (LM sheet)—formed by dispersing copper particles in gallium‐based liquid metal—encapsulated between nanoscale styrene–butadiene–styrene elastomer layers. This trilayer architecture establishes continuous thermal‐conduction pathways while providing excellent electrical insulation and corrosion resistance. The LM sheet achieves impressive in‐plane and through‐plane thermal conductivities (40.4 and 16.7 W m −1 K −1 , respectively), with an elongation at break >200%. Notably, it retains 96% of its thermal conductivity even under 100% tensile strain. It adheres strongly to various substrates without adhesives, excellently spreading heat in flexible heaters and stretchable LED devices under both static and stretched conditions. This paper presents a compelling strategy for developing next‐generation thermal‐interface materials for deformable and skin‐integrated electronic systems.
- 2 February 2026
- Published by Wiley in Advanced Functional Materials
- Vol. 36 (36)
Open AccessNanolayer‐Encapsulated Stretchable Liquid‐Metal Sheets for Thermal Management
Efficient thermal management in stretchable electronics demands materials that seamlessly integrate high thermal conductivity, mechanical flexibility, and reliable interface stability. This paper presents a stretchable, thermally conductive, biphasic, liquid‐metal sheet (LM sheet)—formed by dispersing copper particles in gallium‐based liquid metal—encapsulated between nanoscale styrene–butadiene–styrene elastomer layers. This trilayer architecture establishes continuous thermal‐conduction pathways while providing excellent electrical insulation and corrosion resistance. The LM sheet achieves impressive in‐plane and through‐plane thermal conductivities (40.4 and 16.7 W m −1 K −1 , respectively), with an elongation at break >200%. Notably, it retains 96% of its thermal conductivity even under 100% tensile strain. It adheres strongly to various substrates without adhesives, excellently spreading heat in flexible heaters and stretchable LED devices under both static and stretched conditions. This paper presents a compelling strategy for developing next‐generation thermal‐interface materials for deformable and skin‐integrated electronic systems.
- Open Access
- 12 September 2025
- Published by Wiley in Advanced Robotics Research
Soft Robotic Excretory Care Simulator for Nursing Education: Functional and Perceptual Biomimetics Approach
Despite rapid advances in soft robotics for biomedical applications, little attention has been paid to its potential for simulating interactive nursing procedures that involve complex human responses. In this study, the first soft robotic simulator was specifically designed for training in the digital removal of feces (DRF)—a delicate, discomfort‐sensitive nursing technique frequently performed in home care settings in Japan. Existing DRF training relies on static models that fail to replicate the physiological responses of patients, often leading to inadequate skill acquisition and patient discomfort. To address this gap, we implement a novel simulator incorporating two soft actuators (a pouch‐type actuator for anal sphincter contraction and a McKibben muscle for puborectalis relaxation) and two soft sensors for detecting anal and rectal massage. These are embedded into a multilayer rectal model and integrated with a real‐time feedback interface. Our design uniquely prioritizes both functional fidelity and perceptual realism, enabling trainees to learn from physiological reactions that mimic actual patient responses. Validation with experienced and novice nurses confirms the simulator's effectiveness in improving procedural understanding and confidence. This study demonstrates a new application of soft robotics—not only for anatomical replication, but also as a practical training tool for hands‐on nursing procedures.
- 12 September 2025
- Published by Wiley in Advanced Robotics Research
Open AccessSoft Robotic Excretory Care Simulator for Nursing Education: Functional and Perceptual Biomimetics Approach
Despite rapid advances in soft robotics for biomedical applications, little attention has been paid to its potential for simulating interactive nursing procedures that involve complex human responses. In this study, the first soft robotic simulator was specifically designed for training in the digital removal of feces (DRF)—a delicate, discomfort‐sensitive nursing technique frequently performed in home care settings in Japan. Existing DRF training relies on static models that fail to replicate the physiological responses of patients, often leading to inadequate skill acquisition and patient discomfort. To address this gap, we implement a novel simulator incorporating two soft actuators (a pouch‐type actuator for anal sphincter contraction and a McKibben muscle for puborectalis relaxation) and two soft sensors for detecting anal and rectal massage. These are embedded into a multilayer rectal model and integrated with a real‐time feedback interface. Our design uniquely prioritizes both functional fidelity and perceptual realism, enabling trainees to learn from physiological reactions that mimic actual patient responses. Validation with experienced and novice nurses confirms the simulator's effectiveness in improving procedural understanding and confidence. This study demonstrates a new application of soft robotics—not only for anatomical replication, but also as a practical training tool for hands‐on nursing procedures.
- Open Access
- 3 June 2022
- Published by Wiley in Advanced Electronic Materials
- Vol. 9 (9)
Ultra‐Thin and Conformable Electrodes Composed of Single‐Walled Carbon Nanotube Networks for Skin‐Contact Dielectric Elastomer Actuators
Skin‐contact dielectric elastomer actuators (DEAs) consisting of skin‐conformable, stretchable electrodes are fabricated using a roll‐to‐roll‐based gravure coating method. In this method, single‐walled carbon nanotubes (SWCNTs) are continuously applied on a free‐standing ultra‐thin film (nanosheet) of poly(styrene‐b‐butadiene‐b‐styrene) (SBS) to produce an SWCNT‐SBS nanosheet of 101‐nm thickness. After the first SWCNT coating, the SWCNT‐SBS nanosheet shows a Young's modulus (i.e., 80.9 MPa) comparable to that of the SBS film and a sheet resistance of 4.6 kΩ sq−1. Using the free‐standing SWCNT‐SBS nanosheets as electrodes, a ten‐layered DEA is fabricated without glue or dielectric elastomer precursors on three substrates with different stiffness, namely glass, Ecoflex 00–30, and a urethane elastomer model skin. The low flexural rigidity of the ten‐layered DEA (105 nN m) ensures conformability to the shape of an index finger. Application of an actuation voltage of 2100 V produces a two‐fold larger displacement of the DEA on the Ecoflex 00–30 substrate compared with that on the glass substrate. The ability of the DEA to conform to the surface of skin will enable its application in skin‐contact haptic devices.
- 3 June 2022
- Published by Wiley in Advanced Electronic Materials
- Vol. 9 (9)
Open AccessUltra‐Thin and Conformable Electrodes Composed of Single‐Walled Carbon Nanotube Networks for Skin‐Contact Dielectric Elastomer Actuators
Skin‐contact dielectric elastomer actuators (DEAs) consisting of skin‐conformable, stretchable electrodes are fabricated using a roll‐to‐roll‐based gravure coating method. In this method, single‐walled carbon nanotubes (SWCNTs) are continuously applied on a free‐standing ultra‐thin film (nanosheet) of poly(styrene‐b‐butadiene‐b‐styrene) (SBS) to produce an SWCNT‐SBS nanosheet of 101‐nm thickness. After the first SWCNT coating, the SWCNT‐SBS nanosheet shows a Young's modulus (i.e., 80.9 MPa) comparable to that of the SBS film and a sheet resistance of 4.6 kΩ sq−1. Using the free‐standing SWCNT‐SBS nanosheets as electrodes, a ten‐layered DEA is fabricated without glue or dielectric elastomer precursors on three substrates with different stiffness, namely glass, Ecoflex 00–30, and a urethane elastomer model skin. The low flexural rigidity of the ten‐layered DEA (105 nN m) ensures conformability to the shape of an index finger. Application of an actuation voltage of 2100 V produces a two‐fold larger displacement of the DEA on the Ecoflex 00–30 substrate compared with that on the glass substrate. The ability of the DEA to conform to the surface of skin will enable its application in skin‐contact haptic devices.
- Open Access
- 8 December 2021
- Published by IOP Publishing in Applied Physics Express
- Vol. 15 (1) , 011002
High-Frequency, low-voltage oscillations of dielectric elastomer actuators
To increase safety and reduce the electric circuit cost, dielectric elastomer actuators (DEAs) must operate below the kV range. The simplest strategy to reduce the voltage operation is to decrease the dielectric elastomer membrane thickness. This research aims to demonstrate DEAs with a nanometric uniform thickness that can operate at a low voltage (below 70 V) and a high frequency. We use the roll-to-roll process to fabricate a 600 nm thick stretchable PDMS (polydimethylsiloxane) nanosheet and a 200 nm thick conductive nanosheet. These nanosheet-DEAs are tested in high-frequency operations of DC voltage below 70 V and in a frequency range of 1–30 kHz.
- 8 December 2021
- Published by IOP Publishing in Applied Physics Express
- Vol. 15 (1) , 011002
Open AccessHigh-Frequency, low-voltage oscillations of dielectric elastomer actuators
To increase safety and reduce the electric circuit cost, dielectric elastomer actuators (DEAs) must operate below the kV range. The simplest strategy to reduce the voltage operation is to decrease the dielectric elastomer membrane thickness. This research aims to demonstrate DEAs with a nanometric uniform thickness that can operate at a low voltage (below 70 V) and a high frequency. We use the roll-to-roll process to fabricate a 600 nm thick stretchable PDMS (polydimethylsiloxane) nanosheet and a 200 nm thick conductive nanosheet. These nanosheet-DEAs are tested in high-frequency operations of DC voltage below 70 V and in a frequency range of 1–30 kHz.