Hao Sun
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Hao Sun has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Xuandong Liu
State Key Laboratory of Electrical Insulation and Power Equipment, Xi’an Jiaotong University
8 shared publications Hao Tang
4 shared publications- Minjie Li
State Key Laboratory of Electrical Insulation and Power Equipment, Xi’an Jiaotong University
4 shared publications Gaoyi Shang
3 shared publicationsXueyang Bai
3 shared publicationsYi Zhang
3 shared publications
Latest Publications
- 4 November 2026
- Published by Elsevier in Computers & Mathematics with Applications
- Vol. 224, 412-424
Fast computation of electro-thermal-ion transport coupling field of ±800kV valve-side bushing based on improved SUPG method
- 4 November 2026
- Published by Elsevier in Computers & Mathematics with Applications
- Vol. 224, 412-424
Fast computation of electro-thermal-ion transport coupling field of ±800kV valve-side bushing based on improved SUPG method
- 30 September 2026
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 59 (39) , 395301
Analytical model for surface charge accumulation at the gas–solid interface considering the effect of bulk space charge
Electric field distortions caused by charge accumulation at the gas-solid interface have long posed a serious threat to the safe and stable operation of power systems. To further investigate the surface charge accumulation characteristics of dry bushing, this paper established an experimental platform for measuring surface charge on dry bushing. The study determined the patterns of surface charge accumulation under three types of voltage conditions and developed a simulation model for charge accumulation at the gas-solid interface that accounts for the influence of space charge on the core side. The results show that charge accumulation on the surface of the dry bushing is primarily of opposite polarity, with the most severe charge accumulation occurring near the end of the high-voltage shield along the surface. The superposition of harmonic components leads to a further increase in the surface charge density, with an increase of up to 15.6%. The multi-layer capacitive screen structure of dry-type bushing is prone to the accumulation of space charge between the screens and at the edges, primarily in the form of trapped charge carriers. The accumulation of space charge causes conduction on the solid side to become the dominant factor, significantly exacerbating the accumulation of surface charge on the bushing. The intervention of space charge effects caused the maximum charge density on the bushing surface to increase from −0.07 μ C m −2 to −0.96 μ C m −2 . For electrical equipment such as dry-type bushing, which are prone to space charge accumulation, the influence of space charge on the solid side must not be overlooked when studying surface charge characteristics. The findings of this study can provide insights and serve as a reference for research into the charge accumulation characteristics and mechanisms at the gas-solid interface.
- 30 September 2026
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 59 (39) , 395301
Analytical model for surface charge accumulation at the gas–solid interface considering the effect of bulk space charge
Electric field distortions caused by charge accumulation at the gas-solid interface have long posed a serious threat to the safe and stable operation of power systems. To further investigate the surface charge accumulation characteristics of dry bushing, this paper established an experimental platform for measuring surface charge on dry bushing. The study determined the patterns of surface charge accumulation under three types of voltage conditions and developed a simulation model for charge accumulation at the gas-solid interface that accounts for the influence of space charge on the core side. The results show that charge accumulation on the surface of the dry bushing is primarily of opposite polarity, with the most severe charge accumulation occurring near the end of the high-voltage shield along the surface. The superposition of harmonic components leads to a further increase in the surface charge density, with an increase of up to 15.6%. The multi-layer capacitive screen structure of dry-type bushing is prone to the accumulation of space charge between the screens and at the edges, primarily in the form of trapped charge carriers. The accumulation of space charge causes conduction on the solid side to become the dominant factor, significantly exacerbating the accumulation of surface charge on the bushing. The intervention of space charge effects caused the maximum charge density on the bushing surface to increase from −0.07 μ C m −2 to −0.96 μ C m −2 . For electrical equipment such as dry-type bushing, which are prone to space charge accumulation, the influence of space charge on the solid side must not be overlooked when studying surface charge characteristics. The findings of this study can provide insights and serve as a reference for research into the charge accumulation characteristics and mechanisms at the gas-solid interface.
- Open Access
- 29 August 2026
- Published by Elsevier in SSRN Electronic Journal
Optimization Design of Shielding Cover for Valve-Side Bushings Considering Interface Charge and Electric Field Distributions
Frequent gas-solid interface flashover accidents on valve-side bushings seriously threaten the safe operation of ultra-high voltage direct current (UHVDC) systems. However, optimizing their shielding cover structures still lacks systematic theoretical support. This paper establishes a electric-thermal-ion transport multi-physics coupled model of ±800 kV valve-side bushing. The influence mechanism of the shield cover structure (width, gap distance, and chamfer radius) on charge accumulation and electric field distortion at the core end is studied. Results show that the shield width is the dominant parameter affecting the charge and electric field peaks at the core end. Broadening width from 50 mm to 80 mm suppresses them by over 40% and the peak electric field shift toward the long surface. However, once the electric field peak fully appears on the long surface, further widening offers limited benefit. Meanwhile, gap distance and chamfer radius act locally, suppressing charge density and electric field at gap surface while rebounding the peaks at corner arc. Based on these variation law, a dimensionless design criterion incorporating a corner arc concentration factor (Kc) and a gap non-uniformity factor (Kgap) are proposed, which translate complex electric variation trends into empirical formulas. Ultimately, the optimal shield dimensions for a ±800 kV bushing are identified as w = 80 mm, d = 5–8 mm, and r = 5–30 mm.
- 29 August 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessOptimization Design of Shielding Cover for Valve-Side Bushings Considering Interface Charge and Electric Field Distributions
Frequent gas-solid interface flashover accidents on valve-side bushings seriously threaten the safe operation of ultra-high voltage direct current (UHVDC) systems. However, optimizing their shielding cover structures still lacks systematic theoretical support. This paper establishes a electric-thermal-ion transport multi-physics coupled model of ±800 kV valve-side bushing. The influence mechanism of the shield cover structure (width, gap distance, and chamfer radius) on charge accumulation and electric field distortion at the core end is studied. Results show that the shield width is the dominant parameter affecting the charge and electric field peaks at the core end. Broadening width from 50 mm to 80 mm suppresses them by over 40% and the peak electric field shift toward the long surface. However, once the electric field peak fully appears on the long surface, further widening offers limited benefit. Meanwhile, gap distance and chamfer radius act locally, suppressing charge density and electric field at gap surface while rebounding the peaks at corner arc. Based on these variation law, a dimensionless design criterion incorporating a corner arc concentration factor (Kc) and a gap non-uniformity factor (Kgap) are proposed, which translate complex electric variation trends into empirical formulas. Ultimately, the optimal shield dimensions for a ±800 kV bushing are identified as w = 80 mm, d = 5–8 mm, and r = 5–30 mm.
- Open Access
- 26 June 2026
- Published by Elsevier in SSRN Electronic Journal
Fast computation of electro-thermal-ion transport coupling field of ±800 kV valve-side bushing based on improved SUPG method
The flashover faults of gas-solid interface of converter transformer valve-side bushing have occurred frequently in recent years. However, the existing electro-thermal-ion transport multi-physics coupling model used to guide engineering applications have a poor convergence performance and excessive computational time. This paper first establishes a electro-ion transport model of a scaled-down bushing, and the streamline upwind Petrov–Galerkin (SUPG) method is employed to stabilize the ion convection-diffusion equation. A corresponding experimental platform is built to validate the simulation results. On this basis, an electro-thermal-ion transport multi-physics coupling model of the ±800 kV valve-side bushing is established, and the SUPG method is reformulated and solved in the form of weak-form partial differential equation (PDE). The results show that the PDE can obtain computational results more accurately and faster than the traditional formulation, reducing computational memory and time by 60% and 90%, respectively. Notably, many terms in the PDE have negligible influence on the final results. Based on this observation, a simplified SUPG method is proposed, which further reduces memory usage by 30.20% and computation time by 52.18% while completely preserving the accuracy of the results. Finally, the proposed method is applied to calculate the transient charge and electric field distribution of gas-solid interface of ±800 kV valve-side bushing, achieving satisfactory computational efficiency and accuracy
- 26 June 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessFast computation of electro-thermal-ion transport coupling field of ±800 kV valve-side bushing based on improved SUPG method
The flashover faults of gas-solid interface of converter transformer valve-side bushing have occurred frequently in recent years. However, the existing electro-thermal-ion transport multi-physics coupling model used to guide engineering applications have a poor convergence performance and excessive computational time. This paper first establishes a electro-ion transport model of a scaled-down bushing, and the streamline upwind Petrov–Galerkin (SUPG) method is employed to stabilize the ion convection-diffusion equation. A corresponding experimental platform is built to validate the simulation results. On this basis, an electro-thermal-ion transport multi-physics coupling model of the ±800 kV valve-side bushing is established, and the SUPG method is reformulated and solved in the form of weak-form partial differential equation (PDE). The results show that the PDE can obtain computational results more accurately and faster than the traditional formulation, reducing computational memory and time by 60% and 90%, respectively. Notably, many terms in the PDE have negligible influence on the final results. Based on this observation, a simplified SUPG method is proposed, which further reduces memory usage by 30.20% and computation time by 52.18% while completely preserving the accuracy of the results. Finally, the proposed method is applied to calculate the transient charge and electric field distribution of gas-solid interface of ±800 kV valve-side bushing, achieving satisfactory computational efficiency and accuracy
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- p. 1
Correlation study on the initiation characteristics of epoxy resin degradation under multi-harmonic composite voltages in relation to space charge distribution
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- p. 1
Correlation study on the initiation characteristics of epoxy resin degradation under multi-harmonic composite voltages in relation to space charge distribution
- Open Access
- 24 November 2025
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 138 (20)
Analysis of pseudo-breakdown phenomena and phase-field simulation during epoxy resin insulation degradation
Insulation failure in solid dielectrics poses a great challenge to the safe operation of power equipment. In order to analyze the causes and mechanisms of different degradation processes in insulation materials, this paper builds an experimental platform to simulate the degradation of epoxy resin insulation defects. The degradation of conductive and non-conductive electrical trees under alternating current superimposed direct current voltage was studied. Experimental results show that conductive electrical trees have faster insulation failure times. Non-conductive electrical trees do not lead to insulation failure immediately after developing contact with the ground electrode, and still maintain insulation of the order of 102 s. Partial discharges are the cause of the growth of conductive trees, but not the non-conductive ones. A dimensionless phase-field simulation method is proposed to regulate the electrical tree development process through state parameters. The simulation results indicated that the development of two types of electrical trees is influenced by the strength of the electric field. When the electrostatic energy is not sufficient to cross the body free energy barrier, insulation degradation occurs as a non-conductive electrical tree. This paper provides new ideas for simulating insulation material degradation, which helps to understand the mechanisms of different insulation degradation types from an energy standpoint.
- 24 November 2025
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 138 (20)
Open AccessAnalysis of pseudo-breakdown phenomena and phase-field simulation during epoxy resin insulation degradation
Insulation failure in solid dielectrics poses a great challenge to the safe operation of power equipment. In order to analyze the causes and mechanisms of different degradation processes in insulation materials, this paper builds an experimental platform to simulate the degradation of epoxy resin insulation defects. The degradation of conductive and non-conductive electrical trees under alternating current superimposed direct current voltage was studied. Experimental results show that conductive electrical trees have faster insulation failure times. Non-conductive electrical trees do not lead to insulation failure immediately after developing contact with the ground electrode, and still maintain insulation of the order of 102 s. Partial discharges are the cause of the growth of conductive trees, but not the non-conductive ones. A dimensionless phase-field simulation method is proposed to regulate the electrical tree development process through state parameters. The simulation results indicated that the development of two types of electrical trees is influenced by the strength of the electric field. When the electrostatic energy is not sufficient to cross the body free energy barrier, insulation degradation occurs as a non-conductive electrical tree. This paper provides new ideas for simulating insulation material degradation, which helps to understand the mechanisms of different insulation degradation types from an energy standpoint.
- 25 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. PP (00189456) , 1
The Resonant Optimization and Inverse Analysis of Vibration Capacitance Electrostatic Probe
The phenomenon of charge accumulation poses a significant threat to the electrical and aerospace industries. The accurate measurement and inverse analysis of surface charge has been a topic of great interest among scholars. To enhance the performance of electrostatic sensors, this paper proposes a mechanical vibration structure with a double resonator resonance driving method. A new vibration structure has been designed and its vibration stability is analyzed based on modal analysis. According to test results, using the new driving mode and vibration plate can significantly improve the stability and accuracy of the sensor, and the measurement error is better than 0.5 %. The simulation analysis shows that intervention of the probe leads to the accumulation of surface charge, which is intensified with decreasing probe distance. An inverse calculation method based on the charge of the annular region has been proposed, which can be used to calculate the initial potential before probe intervention.
- 25 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. PP (00189456) , 1
The Resonant Optimization and Inverse Analysis of Vibration Capacitance Electrostatic Probe
The phenomenon of charge accumulation poses a significant threat to the electrical and aerospace industries. The accurate measurement and inverse analysis of surface charge has been a topic of great interest among scholars. To enhance the performance of electrostatic sensors, this paper proposes a mechanical vibration structure with a double resonator resonance driving method. A new vibration structure has been designed and its vibration stability is analyzed based on modal analysis. According to test results, using the new driving mode and vibration plate can significantly improve the stability and accuracy of the sensor, and the measurement error is better than 0.5 %. The simulation analysis shows that intervention of the probe leads to the accumulation of surface charge, which is intensified with decreasing probe distance. An inverse calculation method based on the charge of the annular region has been proposed, which can be used to calculate the initial potential before probe intervention.
- 13 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 32 (5) , 2906-2914
Influence of Multiorder Harmonic Voltage on Degradation in Epoxy Resin Layer of High-Voltage Valve Side Bushing
The internal insulation characteristics of dry-type valve-side bushings in converter transformers under electrical and thermal complex stresses in ultra-high voltage direct current (UHVDC) transmission system are important for ensuring safe and stable operation. In this paper, an UHVDC transmission model is established to simulate the composite voltage waveform containing multiple high-frequency harmonic components. The insulation degradation experiments are conducted by using the harmonic voltage superimposed on the negative polarity DC voltage at 100 °C environment. The experimental results show that the initiation voltage of the electrical tree under multi-harmonic voltage reduces by 44%, and the insulation failure time shortens from 104 s level to 102 s level, compared to the results under direct current (DC) superimposed on a fundamental frequency alternating current (AC) voltage. The morphology of the electrical tree gradually develops from branching to clumping. The phase of the partial discharge signal during the growth of the electrical tree shows "multi-peak" characteristics with the composite waveform, and the partial discharge exhibits periodic saturation behavior. The actual operating waveform of dry-type valve-side bushing causes more serious damage to the insulating properties of epoxy resin material, and the composite effect of high harmonics and high temperature should be taken into account when considering the design and operation of converter transformers.
- 13 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 32 (5) , 2906-2914
Influence of Multiorder Harmonic Voltage on Degradation in Epoxy Resin Layer of High-Voltage Valve Side Bushing
The internal insulation characteristics of dry-type valve-side bushings in converter transformers under electrical and thermal complex stresses in ultra-high voltage direct current (UHVDC) transmission system are important for ensuring safe and stable operation. In this paper, an UHVDC transmission model is established to simulate the composite voltage waveform containing multiple high-frequency harmonic components. The insulation degradation experiments are conducted by using the harmonic voltage superimposed on the negative polarity DC voltage at 100 °C environment. The experimental results show that the initiation voltage of the electrical tree under multi-harmonic voltage reduces by 44%, and the insulation failure time shortens from 104 s level to 102 s level, compared to the results under direct current (DC) superimposed on a fundamental frequency alternating current (AC) voltage. The morphology of the electrical tree gradually develops from branching to clumping. The phase of the partial discharge signal during the growth of the electrical tree shows "multi-peak" characteristics with the composite waveform, and the partial discharge exhibits periodic saturation behavior. The actual operating waveform of dry-type valve-side bushing causes more serious damage to the insulating properties of epoxy resin material, and the composite effect of high harmonics and high temperature should be taken into account when considering the design and operation of converter transformers.
- 16 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 50 (1) , 79-87
Discharge Characteristics of Fusion Plasma Jet Array and its Influencing Factors
The downstream uniformity of the atmospheric-pressure plasma jet (APPJ) array is a key technical problem with regard to large-scale applications nowadays. However, as the only array that can achieve large uniform plasma action area currently, the discharge characteristics and its influencing factors of the fusion plasma jet array have not been fully studied. In order to solve this problem, this article studies the discharge characteristics of the fusion APPJ array under different parameters, obtains its discharge mode conversion patterns and conversion characteristics, and thus the parameter conditions for achieving the diffused discharge mode. Finally, the influence of the thickness of the discharge dielectric tube and the inner diameter of the secondary tube on the discharge characteristics of the fusion APPJ array is studied. Results show that increasing the voltage amplitude and gas flow rate will both cause the discharge mode of the fusion plasma jet array to experience a conversion from starting discharge to diffused discharge mode to filament discharge mode. For the array with the thickness of the discharge dielectric tube of 1 mm and the inner diameter of the secondary tube of 20 mm, when the gas flow rate is between 1.6 and 2.8 L/min, the array can achieve the diffused discharge mode; reducing the thickness of the discharge dielectric tube will cause the gas flow rate under the diffused discharge mode to decrease; changing the inner diameter of the secondary tube hardly affects the parameter interval distribution of the discharge modes. The results of this article may provide a theoretical foundation for achieving large-scale plasma jet source.
- 16 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 50 (1) , 79-87
Discharge Characteristics of Fusion Plasma Jet Array and its Influencing Factors
The downstream uniformity of the atmospheric-pressure plasma jet (APPJ) array is a key technical problem with regard to large-scale applications nowadays. However, as the only array that can achieve large uniform plasma action area currently, the discharge characteristics and its influencing factors of the fusion plasma jet array have not been fully studied. In order to solve this problem, this article studies the discharge characteristics of the fusion APPJ array under different parameters, obtains its discharge mode conversion patterns and conversion characteristics, and thus the parameter conditions for achieving the diffused discharge mode. Finally, the influence of the thickness of the discharge dielectric tube and the inner diameter of the secondary tube on the discharge characteristics of the fusion APPJ array is studied. Results show that increasing the voltage amplitude and gas flow rate will both cause the discharge mode of the fusion plasma jet array to experience a conversion from starting discharge to diffused discharge mode to filament discharge mode. For the array with the thickness of the discharge dielectric tube of 1 mm and the inner diameter of the secondary tube of 20 mm, when the gas flow rate is between 1.6 and 2.8 L/min, the array can achieve the diffused discharge mode; reducing the thickness of the discharge dielectric tube will cause the gas flow rate under the diffused discharge mode to decrease; changing the inner diameter of the secondary tube hardly affects the parameter interval distribution of the discharge modes. The results of this article may provide a theoretical foundation for achieving large-scale plasma jet source.
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 235-238
Calculation of the Switch Arc in Low Voltage Circuit Breaker Considering the Interaction Between the Contact Movement and the Arc Force
During the interruption, the separation of the contacts plays an important role in different kinds of switch gears since the arc motion or the arc elongation will be affected. The movement of the contact could increase the arc length and then decide the arc behavior. In reverse, the arc current will be changed during the interruption and the Lorentz force will then influence the movement of the contact. It is necessary to consider this phenomenon to make the arc simulation more accurate and universal. In this work, low voltage arc plasma simulation in 3D with contact opening process has been established. Both the sheath and nonlinear magnetic material were taken into consideration. Calculation was based on magneto-hydrodynamic arc model, and a method of coupling different software to separately calculate fluid and electromagnetic field has been developed to fulfill the requirements above. Furthermore, a low voltage circuit breaker has been tested to validate the simulation with U-I characteristics.
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 235-238
Calculation of the Switch Arc in Low Voltage Circuit Breaker Considering the Interaction Between the Contact Movement and the Arc Force
During the interruption, the separation of the contacts plays an important role in different kinds of switch gears since the arc motion or the arc elongation will be affected. The movement of the contact could increase the arc length and then decide the arc behavior. In reverse, the arc current will be changed during the interruption and the Lorentz force will then influence the movement of the contact. It is necessary to consider this phenomenon to make the arc simulation more accurate and universal. In this work, low voltage arc plasma simulation in 3D with contact opening process has been established. Both the sheath and nonlinear magnetic material were taken into consideration. Calculation was based on magneto-hydrodynamic arc model, and a method of coupling different software to separately calculate fluid and electromagnetic field has been developed to fulfill the requirements above. Furthermore, a low voltage circuit breaker has been tested to validate the simulation with U-I characteristics.