Abstract
Frequent gas-solid interface flashover accidents on valve-side bushings seriously threaten the safe operation of ultra-high voltage direct current (UHVDC) systems. However, optimizing their shielding cover structures still lacks systematic theoretical support. This paper establishes a electric-thermal-ion transport multi-physics coupled model of ±800 kV valve-side bushing. The influence mechanism of the shield cover structure (width, gap distance, and chamfer radius) on charge accumulation and electric field distortion at the core end is studied. Results show that the shield width is the dominant parameter affecting the charge and electric field peaks at the core end. Broadening width from 50 mm to 80 mm suppresses them by over 40% and the peak electric field shift toward the long surface. However, once the electric field peak fully appears on the long surface, further widening offers limited benefit. Meanwhile, gap distance and chamfer radius act locally, suppressing charge density and electric field at gap surface while rebounding the peaks at corner arc. Based on these variation law, a dimensionless design criterion incorporating a corner arc concentration factor (Kc) and a gap non-uniformity factor (Kgap) are proposed, which translate complex electric variation trends into empirical formulas. Ultimately, the optimal shield dimensions for a ±800 kV bushing are identified as w = 80 mm, d = 5–8 mm, and r = 5–30 mm.

This publication has 8 references indexed in Scilit: