Zihao Song
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Zihao Song has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Ning Zhu
Center for Combustion Energy, Department of Energy and Power Engineering and Key Laboratory for Thermal Science and Power Engineering of Ministry of Education, Tsinghua University, Beijing 100084, People’s Republic of China
3 shared publications - Weitian Wang
Center for Combustion Energy, Tsinghua University, Beijing 100084, People’s Republic of China
3 shared publications - Xing Chao
New Cornerstone Science Laboratory, Center for Combustion Energy, Key Laboratory for Thermal Science and Power Engineering of MoE, Department of Energy and Power Engineering, Tsinghua University, Beijing, China
3 shared publications - Anna-Lena Sahlberg
Department of Physics Lund University Lund Sweden
2 shared publications - Changshuo Yan
National Astronomical Observatories, Chinese Academy of Sciences , 20A Datun Road, Beijing 100101
1 shared publication - Junqiang Ge
National Astronomical Observatories, Chinese Academy of Sciences, Beijing 100101, China
1 shared publication
Latest Publications
- 1 July 2024
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 35 (9) , 095208
Directly-excited laser-induced thermal grating spectroscopy and thermometry with carbon dioxide vibrational transition
Laser-induced thermal grating spectroscopy (LITGS) has been proved for accurate thermometry and measurement of energy transfer processes in molecules. While electronic transitions are often used for excitation in previous LITGS works, here we report laser-induced thermal gratings formed by direct excitation of CO2 with an infrared (IR) laser at wavelength near 2 μm, with which high signal-to-noise ratio LITGS signals are generated (SNR ∼ 300 at room temperature). A theoretical LITGS model assuming a ‘two-steps’ energy transfer process is used to describe the recorded signal waveform, with relative fitting residuals of less than 10%. Quantitative thermometry is performed in CO2 gas flows between 293 K and 420 K, with a relative uncertainty of 1.6% and a precision of 1.1% defined as the 1-σ standard deviation of 30 repeated measurement. Furthermore, the time constants of vibrational energy transfer at different temperatures are extracted from the temporal signal waveform with a precision better than 80 ns, and the measured results are consistent with the simulation using a detailed vibrational energy transfer model. These results demonstrate IR LITGS as a potential tool for spatially-resolved measurement of the thermophysical properties of fluids, as well as molecular vibrational energy transfer processes.
- 1 July 2024
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 35 (9) , 095208
Directly-excited laser-induced thermal grating spectroscopy and thermometry with carbon dioxide vibrational transition
Laser-induced thermal grating spectroscopy (LITGS) has been proved for accurate thermometry and measurement of energy transfer processes in molecules. While electronic transitions are often used for excitation in previous LITGS works, here we report laser-induced thermal gratings formed by direct excitation of CO2 with an infrared (IR) laser at wavelength near 2 μm, with which high signal-to-noise ratio LITGS signals are generated (SNR ∼ 300 at room temperature). A theoretical LITGS model assuming a ‘two-steps’ energy transfer process is used to describe the recorded signal waveform, with relative fitting residuals of less than 10%. Quantitative thermometry is performed in CO2 gas flows between 293 K and 420 K, with a relative uncertainty of 1.6% and a precision of 1.1% defined as the 1-σ standard deviation of 30 repeated measurement. Furthermore, the time constants of vibrational energy transfer at different temperatures are extracted from the temporal signal waveform with a precision better than 80 ns, and the measured results are consistent with the simulation using a detailed vibrational energy transfer model. These results demonstrate IR LITGS as a potential tool for spatially-resolved measurement of the thermophysical properties of fluids, as well as molecular vibrational energy transfer processes.
- Open Access
- 26 February 2024
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 78 (5) , 538-550
Temperature and Thermal Diffusivity Diagnostics in Laminar Methane Flames Using Infrared Four-Wave Mixing Techniques
Four-wave mixing techniques, such as coherent anti-Stokes Raman spectroscopy (CARS), laser-induced grating spectroscopy (LIGS), and degenerate four-wave mixing (DFWM), have been widely used in combustion diagnostics due to their advantages of high signal-to-noise ratio (S/N), coherent signal, and spatial resolution. In this work, a nano-second pulsed laser is utilized to generate mid-infrared (near 3 µm) pump beams, exciting the rovibrational transitions of nascent water in flames. Combined LIGS and DFWM measurements are demonstrated in premixed laminar CH 4 /O 2 /N 2 flames with equivalence ratios from 0.6 to 1.5, to achieve precise thermometry in a wide range of flame conditions. The flame temperatures were also measured by thermocouple as a reference, and the results from LIGS and DFWM align well with the trends shown in the thermocouple measurements. In fuel-lean flames, where the mass-to-specific-heat ratio variation is minimal, LIGS provides temperature data with a precision better than 16 K (0.8%). In fuel-rich flames, where the increased H 2 concentration in the flame introduces uncertainty in gas constants thus affecting the accuracy of LIGS thermometry, DFWM is instead employed for temperature measurement since it is less sensitive to the gas composition within the measured volume. The high-precision LIGS temperatures in lean flames serve as temperature reference during the DFWM calibration of the degree of saturation, and a precision better than 90 K (4.5%) is achieved for DFWM thermometry. In addition to temperature, a theoretical model is employed to fit LIGS signal time waveforms, extracting the local speed of sound and thermal diffusivity with precisions better than 0.5% and 1.3%, respectively. These high-precision measurements contribute additional data for flame research and simulation calculations. This way, the combined use of DFWM and LIGS proves the potential for accurate thermometry and diagnostics of other thermodynamic parameters across a wide range of flame conditions.
- 26 February 2024
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 78 (5) , 538-550
Open AccessTemperature and Thermal Diffusivity Diagnostics in Laminar Methane Flames Using Infrared Four-Wave Mixing Techniques
Four-wave mixing techniques, such as coherent anti-Stokes Raman spectroscopy (CARS), laser-induced grating spectroscopy (LIGS), and degenerate four-wave mixing (DFWM), have been widely used in combustion diagnostics due to their advantages of high signal-to-noise ratio (S/N), coherent signal, and spatial resolution. In this work, a nano-second pulsed laser is utilized to generate mid-infrared (near 3 µm) pump beams, exciting the rovibrational transitions of nascent water in flames. Combined LIGS and DFWM measurements are demonstrated in premixed laminar CH 4 /O 2 /N 2 flames with equivalence ratios from 0.6 to 1.5, to achieve precise thermometry in a wide range of flame conditions. The flame temperatures were also measured by thermocouple as a reference, and the results from LIGS and DFWM align well with the trends shown in the thermocouple measurements. In fuel-lean flames, where the mass-to-specific-heat ratio variation is minimal, LIGS provides temperature data with a precision better than 16 K (0.8%). In fuel-rich flames, where the increased H 2 concentration in the flame introduces uncertainty in gas constants thus affecting the accuracy of LIGS thermometry, DFWM is instead employed for temperature measurement since it is less sensitive to the gas composition within the measured volume. The high-precision LIGS temperatures in lean flames serve as temperature reference during the DFWM calibration of the degree of saturation, and a precision better than 90 K (4.5%) is achieved for DFWM thermometry. In addition to temperature, a theoretical model is employed to fit LIGS signal time waveforms, extracting the local speed of sound and thermal diffusivity with precisions better than 0.5% and 1.3%, respectively. These high-precision measurements contribute additional data for flame research and simulation calculations. This way, the combined use of DFWM and LIGS proves the potential for accurate thermometry and diagnostics of other thermodynamic parameters across a wide range of flame conditions.
- Open Access
- 1 December 2023
- Published by AIP Publishing in Physics of Fluids
- Vol. 35 (12)
Full-field vapor concentration and temperature field measurement of an evaporating ethanol–water binary sessile drop by tomographic laser absorption spectroscopy
Quantitative measurement of full-field, spatially resolved temperature and concentration field of pure water and ethanol–water binary evaporating drop is realized, in which the gas-phase and interfacial temperature and concentration are accurately captured. By studying the vapor field of evaporating drop under different heating temperatures, it is demonstrated that the method can achieve a spatial resolution below 100 μm and a time resolution of <10 s. Simultaneous gas-phase temperature and concentration field measurements reveal the occurrence of buoyancy convection in the gas phase. Through the analysis of interfacial temperature and concentration distribution, it is observed that in the process of pure water drop evaporation, both buoyancy-driven convection and thermal Marangoni convection exist, while in the ethanol–water binary drop evaporation, the solutal Marangoni flow convection and thermal Marangoni convection are coupled, and the buoyancy convection is suppressed. The interfacial temperature and gas-phase water vapor concentration can be obtained from the water vapor measurement, and combined with the activity coefficient models. The liquid-phase mole fraction of water at the interface and its distribution are also obtained, such that the liquid-phase mole fraction distribution of ethanol at the interface can be obtained, and finally, the concentration of ethanol vapor near the interface is obtained. The full-field, high-resolution measurement of evaporated drops is of substantial significance for in-depth understanding of the evaporation process. The measurement of ethanol–water binary drop evaporation provides a new research perception and method exploiting the spectral dimension, providing both quantitative and qualitative observations for the study of multi-component drop evaporation.
- 1 December 2023
- Published by AIP Publishing in Physics of Fluids
- Vol. 35 (12)
Open AccessFull-field vapor concentration and temperature field measurement of an evaporating ethanol–water binary sessile drop by tomographic laser absorption spectroscopy
Quantitative measurement of full-field, spatially resolved temperature and concentration field of pure water and ethanol–water binary evaporating drop is realized, in which the gas-phase and interfacial temperature and concentration are accurately captured. By studying the vapor field of evaporating drop under different heating temperatures, it is demonstrated that the method can achieve a spatial resolution below 100 μm and a time resolution of <10 s. Simultaneous gas-phase temperature and concentration field measurements reveal the occurrence of buoyancy convection in the gas phase. Through the analysis of interfacial temperature and concentration distribution, it is observed that in the process of pure water drop evaporation, both buoyancy-driven convection and thermal Marangoni convection exist, while in the ethanol–water binary drop evaporation, the solutal Marangoni flow convection and thermal Marangoni convection are coupled, and the buoyancy convection is suppressed. The interfacial temperature and gas-phase water vapor concentration can be obtained from the water vapor measurement, and combined with the activity coefficient models. The liquid-phase mole fraction of water at the interface and its distribution are also obtained, such that the liquid-phase mole fraction distribution of ethanol at the interface can be obtained, and finally, the concentration of ethanol vapor near the interface is obtained. The full-field, high-resolution measurement of evaporated drops is of substantial significance for in-depth understanding of the evaporation process. The measurement of ethanol–water binary drop evaporation provides a new research perception and method exploiting the spectral dimension, providing both quantitative and qualitative observations for the study of multi-component drop evaporation.
- 1 December 2021
- Published by AIP Publishing in Physics of Fluids
- Vol. 33 (12) , 125126
Gas velocimetry based on infrared laser-induced fluorescence
A novel method for gas velocity field measurements by means of infrared molecular tagging velocimetry is reported with proof-of-principle demonstration in a carbon dioxide (CO2) axisymmetric turbulent jet. Infrared laser-induced fluorescence utilizes the resonant vibrational energy level transitions of small gas molecules, such as CO2, to “tag” and trace the flow of the molecules by taking subsequent images of the infrared emission. Spectroscopic model of the molecular vibrational energy transfer processes is taken into account to design and optimize the measurement scheme. The infrared images are then analyzed, with detailed consideration of molecular diffusion, lateral velocity, and fluorescence lifetime, to yield quantitative velocity field distribution. The radial velocity distributions in the jet main region, with velocities ranging from 7 to 50 m/s, are obtained and shown to be in excellent agreement with theoretical predication and previous experimental works. Velocity uncertainties are discussed and estimated to be 7.7%, 6.7%, 6.1% for Re = 104, (maximum velocity m/s), respectively. Spatial resolution along the laser beam is estimated to be 107 μm. To the best of the authors' knowledge, this is the first work of infrared molecular tagging velocimetry. With powerful excitation lasers targeting strong infrared molecular absorption transitions, this technique presents great potential for simultaneous flow-scalar field measurements at much-improved accuracy, spatial and temporal resolution, that can be used for the study of low-speed micro-flows, or instantaneous snapshots of turbulent flows.- 1 December 2021
- Published by AIP Publishing in Physics of Fluids
- Vol. 33 (12) , 125126
Gas velocimetry based on infrared laser-induced fluorescence
A novel method for gas velocity field measurements by means of infrared molecular tagging velocimetry is reported with proof-of-principle demonstration in a carbon dioxide (CO2) axisymmetric turbulent jet. Infrared laser-induced fluorescence utilizes the resonant vibrational energy level transitions of small gas molecules, such as CO2, to “tag” and trace the flow of the molecules by taking subsequent images of the infrared emission. Spectroscopic model of the molecular vibrational energy transfer processes is taken into account to design and optimize the measurement scheme. The infrared images are then analyzed, with detailed consideration of molecular diffusion, lateral velocity, and fluorescence lifetime, to yield quantitative velocity field distribution. The radial velocity distributions in the jet main region, with velocities ranging from 7 to 50 m/s, are obtained and shown to be in excellent agreement with theoretical predication and previous experimental works. Velocity uncertainties are discussed and estimated to be 7.7%, 6.7%, 6.1% for Re = 104, (maximum velocity m/s), respectively. Spatial resolution along the laser beam is estimated to be 107 μm. To the best of the authors' knowledge, this is the first work of infrared molecular tagging velocimetry. With powerful excitation lasers targeting strong infrared molecular absorption transitions, this technique presents great potential for simultaneous flow-scalar field measurements at much-improved accuracy, spatial and temporal resolution, that can be used for the study of low-speed micro-flows, or instantaneous snapshots of turbulent flows.- Open Access
- 1 April 2021
- Published by American Astronomical Society in The Astrophysical Journal
- Vol. 910 (2) , 101
Variation of Broad Emission Lines from QSOs with Optical/UV Periodicity to Test the Interpretation of Supermassive Binary Black Holes
Periodic quasars have been suggested to host supermassive binary black holes (BBHs) in their centers, and their optical/UV periodicities are interpreted as caused by either the Doppler-boosting (DB) effect of continuum emission from the disk around the secondary black hole (BH) or intrinsic accretion rate variation. However, no other definitive evidence has been found to confirm such a BBH interpretation(s). In this paper, we investigate the responses of broad emission lines (BELs) to the continuum variations for these quasars under two BBH scenarios and check whether they can be distinguished from each other and from that of a single BH system. We assume a simple circumbinary broad-line region (BLR) model, compatible with BLR size estimates, with a standard Γ distribution of BLR clouds. We find that BELs may change significantly and periodically under the BBH scenarios due to (1) the position variation of the secondary BH and (2) the DB effect, if significant, and/or intrinsic variation, which is significantly different from the case of a single BH system. For the two BBH scenarios, the responses of BELs to (apparent) continuum variations, caused by the DB effect or intrinsic rate variation, are also significantly different from each other, mainly because the DB effect has a preferred direction along the direction of motion of the secondary BH, while that due to intrinsic variation does not. Such differences in the responses of BELs from different scenarios may offer a robust way to distinguish different interpretations of periodic quasars and to identify BBHs, if any, in these systems.
- 1 April 2021
- Published by American Astronomical Society in The Astrophysical Journal
- Vol. 910 (2) , 101
Open AccessVariation of Broad Emission Lines from QSOs with Optical/UV Periodicity to Test the Interpretation of Supermassive Binary Black Holes
Periodic quasars have been suggested to host supermassive binary black holes (BBHs) in their centers, and their optical/UV periodicities are interpreted as caused by either the Doppler-boosting (DB) effect of continuum emission from the disk around the secondary black hole (BH) or intrinsic accretion rate variation. However, no other definitive evidence has been found to confirm such a BBH interpretation(s). In this paper, we investigate the responses of broad emission lines (BELs) to the continuum variations for these quasars under two BBH scenarios and check whether they can be distinguished from each other and from that of a single BH system. We assume a simple circumbinary broad-line region (BLR) model, compatible with BLR size estimates, with a standard Γ distribution of BLR clouds. We find that BELs may change significantly and periodically under the BBH scenarios due to (1) the position variation of the secondary BH and (2) the DB effect, if significant, and/or intrinsic variation, which is significantly different from the case of a single BH system. For the two BBH scenarios, the responses of BELs to (apparent) continuum variations, caused by the DB effect or intrinsic rate variation, are also significantly different from each other, mainly because the DB effect has a preferred direction along the direction of motion of the secondary BH, while that due to intrinsic variation does not. Such differences in the responses of BELs from different scenarios may offer a robust way to distinguish different interpretations of periodic quasars and to identify BBHs, if any, in these systems.