Guillermo Cortela
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Guillermo Cortela has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
- Wagner Coelho de Albuquerque Pereira
Biomedical Engineering Program - COPPE, Federal University of Rio de Janeiro, Rio de Janeiro, RJ, Brazil
8 shared publications C. Negreira
Laboratorio de Acústica Ultrasónica, IFFC, Universidad de la República, MVD, Uruguay
6 shared publicationsCarlos A. Negreira
Laboratory of Ultrasound, Physics Institute, Universidad de la República, Montevideo, Uruguay
5 shared publications- Franco Simini
Universidad de la República
5 shared publications - Marco Antônio von Krüger
Biomedical Engineering Program, COPPE, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil
5 shared publications - Natalia Garay Badenian
Universidad de la República
5 shared publications
Latest Publications
- 16 October 2025
- Published by Springer Nature
- p. 888-898
Ultrasound as Transcranial Neuroablation Tool in Phantoms: Preliminary Experimental Results
- 16 October 2025
- Published by Springer Nature
- p. 888-898
Ultrasound as Transcranial Neuroablation Tool in Phantoms: Preliminary Experimental Results
- 28 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Ultrasound-Induced Temperature Increase in a Brain Phantom Toward Epilepsy Ablation Applications
Approximately 30% of epileptic patients are refractory to medication. This highlighting the need for alternative non-invasive treatments. High-intensity focused ultrasound (HIFU) has been proposed for thermal ablation of epileptic foci. This study aimed to develop a brain tissue phantom and an experimental setup to evaluate HIFU's thermal effects. A phantom composed of agar and egg whites was designed to mimic brain tissue's acoustic properties. Experiments were conducted using a robotic ultrasonic positioning system, with irradiation at transducer excitation power of 11.05 to 25.5 W for 25–40 seconds. Temperature changes were monitored with thermocouples, and coagulation was visually assessed. Results showed a correlation between exposure time, intensity, and temperature increase, confirming the phantom's ability to simulate thermal effects. The study demonstrated that the chosen phantom effectively models brain tissue for ultrasound-induced thermal ablation. These findings contribute to optimizing HIFU parameters for future applications in epilepsy treatment.
- 28 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Ultrasound-Induced Temperature Increase in a Brain Phantom Toward Epilepsy Ablation Applications
Approximately 30% of epileptic patients are refractory to medication. This highlighting the need for alternative non-invasive treatments. High-intensity focused ultrasound (HIFU) has been proposed for thermal ablation of epileptic foci. This study aimed to develop a brain tissue phantom and an experimental setup to evaluate HIFU's thermal effects. A phantom composed of agar and egg whites was designed to mimic brain tissue's acoustic properties. Experiments were conducted using a robotic ultrasonic positioning system, with irradiation at transducer excitation power of 11.05 to 25.5 W for 25–40 seconds. Temperature changes were monitored with thermocouples, and coagulation was visually assessed. Results showed a correlation between exposure time, intensity, and temperature increase, confirming the phantom's ability to simulate thermal effects. The study demonstrated that the chosen phantom effectively models brain tissue for ultrasound-induced thermal ablation. These findings contribute to optimizing HIFU parameters for future applications in epilepsy treatment.
- 3 May 2025
- Published by Springer Nature in Research on Biomedical Engineering
- Vol. 41 (2) , 1-16
Singular spectrum analysis – an automatic detection technique for mean scatterer spacing estimation using ultrasound signals
- 3 May 2025
- Published by Springer Nature in Research on Biomedical Engineering
- Vol. 41 (2) , 1-16
Singular spectrum analysis – an automatic detection technique for mean scatterer spacing estimation using ultrasound signals
- 31 May 2024
- Published by Springer Nature
- p. 263-269
Brain Tissue Phantom Review to Study Ultrasound Energy Delivery Towards Epileptic Foci Inhibition with CENEPSIA
- 31 May 2024
- Published by Springer Nature
- p. 263-269
Brain Tissue Phantom Review to Study Ultrasound Energy Delivery Towards Epileptic Foci Inhibition with CENEPSIA
- 4 January 2024
- Published by Springer Nature
- p. 403-408
Review of Ultrasound as Neurological Treatment
- 19 June 2023
- Published by Elsevier in Ultrasonics
- Vol. 134, 107077
Quadratic versus linear models to estimate the mean scattering spacing as a function of temperature in ex-vivo tissue
- 19 June 2023
- Published by Elsevier in Ultrasonics
- Vol. 134, 107077
Quadratic versus linear models to estimate the mean scattering spacing as a function of temperature in ex-vivo tissue
- 13 May 2023
- Published by Springer Nature in Research on Biomedical Engineering
- Vol. 39 (2) , 427-436
CENEPSIA: feasibility of an ultrasound device to treat epileptic refractory foci
- 13 May 2023
- Published by Springer Nature in Research on Biomedical Engineering
- Vol. 39 (2) , 427-436
CENEPSIA: feasibility of an ultrasound device to treat epileptic refractory foci
- 1 March 2020
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 147 (3) , 1531-1545
Durability study of a gellan gum-based tissue-mimicking phantom for ultrasonic thermal therapy
Stability and duration of ultrasonic phantoms are still subjects of research. This work presents a tissue-mimicking material (TMM) to evaluate high-intensity therapeutic ultrasound (HITU) devices, composed of gellan gum (matrix), microparticles (scatterers), and chemicals. The ultrasonic velocity and attenuation coefficient were characterized as a function of temperature (range 20 °C–85 °C). The nonlinear parameter B/A was determined by the finite amplitude insertion substitution (FAIS) method, and the shear modulus was determined by a transient elastography technique. The thermal conductivity and specific heat were determined by the line source method. The attenuation was stable for 60 days, and in an almost linear frequency dependence (0.51f0.96 dB cm−1), at 20 °C (1–10 MHz). All other evaluated physical parameters are also close to typical soft tissue values. Longitudinal ultrasonic velocities were between 1.49 and 1.75 mm μs−1, the B/A parameter was 7.8 at 30 °C, and Young's modulus was 23.4 kPa. The thermal conductivity and specific heat values were 0.7 W(m K)−1 and 4.7 kJ(kg K)−1, respectively. Consistent temperature increases and thermal doses occurred under identical HITU exposures. Low cost, longevity, thermal stability, and thermal repeatability make TMM an excellent material for ultrasonic thermal applications. The TMM developed has the potential to assess the efficacy of hyperthermia devices and could be used to adjust the ultrasonic emission of HITU devices.
- 1 March 2020
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 147 (3) , 1531-1545
Durability study of a gellan gum-based tissue-mimicking phantom for ultrasonic thermal therapy
Stability and duration of ultrasonic phantoms are still subjects of research. This work presents a tissue-mimicking material (TMM) to evaluate high-intensity therapeutic ultrasound (HITU) devices, composed of gellan gum (matrix), microparticles (scatterers), and chemicals. The ultrasonic velocity and attenuation coefficient were characterized as a function of temperature (range 20 °C–85 °C). The nonlinear parameter B/A was determined by the finite amplitude insertion substitution (FAIS) method, and the shear modulus was determined by a transient elastography technique. The thermal conductivity and specific heat were determined by the line source method. The attenuation was stable for 60 days, and in an almost linear frequency dependence (0.51f0.96 dB cm−1), at 20 °C (1–10 MHz). All other evaluated physical parameters are also close to typical soft tissue values. Longitudinal ultrasonic velocities were between 1.49 and 1.75 mm μs−1, the B/A parameter was 7.8 at 30 °C, and Young's modulus was 23.4 kPa. The thermal conductivity and specific heat values were 0.7 W(m K)−1 and 4.7 kJ(kg K)−1, respectively. Consistent temperature increases and thermal doses occurred under identical HITU exposures. Low cost, longevity, thermal stability, and thermal repeatability make TMM an excellent material for ultrasonic thermal applications. The TMM developed has the potential to assess the efficacy of hyperthermia devices and could be used to adjust the ultrasonic emission of HITU devices.
- 25 September 2019
- Published by Springer Nature
- p. 780-786
Backscattered Ultrasound Periodicity Characterization on Trabecular Bone-Mimicking Phantoms: A Spectral and Wavelets Approach
- 25 September 2019
- Published by Springer Nature
- p. 780-786
Backscattered Ultrasound Periodicity Characterization on Trabecular Bone-Mimicking Phantoms: A Spectral and Wavelets Approach
- 25 September 2019
- Published by Springer Nature
- p. 1307-1314
Effect of Continuous Application of Heating-Cooling Cycles on Ultrasonic Attenuation of Muscle Tissue
- 25 September 2019
- Published by Springer Nature
- p. 1307-1314
Effect of Continuous Application of Heating-Cooling Cycles on Ultrasonic Attenuation of Muscle Tissue