S. B. Ryutin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
S. B. Ryutin has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Pavel V. Skripov
Institute of Thermal Physics Ural Branch of Russian Academy Sciences, Ekaterinburg, Russia
5 shared publications - Alexander A. Igolnikov
Department of Physics and Technology, Ural Federal University, 620002 Ekaterinburg, Russia
3 shared publications A. A. Igol’NIkov
Institute of Thermophysics, Ural Branch, Russian Academy of Sciences, Yekaterinburg, Russia
1 shared publication- Alexander I. Lipchak
Institute of Electrophysics, Ural Branch, Russian Academy of Sciences, Yekaterinburg, Russia
1 shared publication P. V. Skripov
Russian Academy of Sciences
1 shared publication
Latest Publications
- 1 October 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (10)
Experimental setup for comprehensive study of non-stationary heat transfer in complex liquid media
This paper presents a setup for studying non-stationary heat exchange in liquid media on a scale of small times and sizes at high heat flux densities created using a high-speed precision power controller. A platinum wire with a diameter of 20 μm and a length from 0.5 to 1 cm is used as a probe. The heating time ranged from 1 to 300 ms, and the heat flux densities from 1 to 20 MW/m2 were achieved in the experiments. Strictly specified conditions for heat release in the probe are confirmed by maintaining a constant power in a series of pulses with an accuracy of 0.05%. Acquiring a primary electrical signal of thermograms is synchronized with high-speed video recording, allowing an accurate relationship between the applied thermal load and the mechanics of processes in the studied liquid. The setup capabilities were shown by comparing the boiling patterns of a simple substance, such as ethanol, and a solution with a lower critical solution temperature, a 30 vol. % solution of polypropylene glycol-425 in water, which have similar thermograms. As a result, a qualitative difference between the heating and boiling patterns observed using high-speed video and the presented setup fitting its purpose has been shown.
- 1 October 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (10)
Experimental setup for comprehensive study of non-stationary heat transfer in complex liquid media
This paper presents a setup for studying non-stationary heat exchange in liquid media on a scale of small times and sizes at high heat flux densities created using a high-speed precision power controller. A platinum wire with a diameter of 20 μm and a length from 0.5 to 1 cm is used as a probe. The heating time ranged from 1 to 300 ms, and the heat flux densities from 1 to 20 MW/m2 were achieved in the experiments. Strictly specified conditions for heat release in the probe are confirmed by maintaining a constant power in a series of pulses with an accuracy of 0.05%. Acquiring a primary electrical signal of thermograms is synchronized with high-speed video recording, allowing an accurate relationship between the applied thermal load and the mechanics of processes in the studied liquid. The setup capabilities were shown by comparing the boiling patterns of a simple substance, such as ethanol, and a solution with a lower critical solution temperature, a 30 vol. % solution of polypropylene glycol-425 in water, which have similar thermograms. As a result, a qualitative difference between the heating and boiling patterns observed using high-speed video and the presented setup fitting its purpose has been shown.
- 1 August 2024
- Published by Pleiades Publishing Ltd in Journal of Applied Mechanics and Technical Physics
- Vol. 65 (4) , 771-783
RESPONSE OF A MICROHEATER–SOLUTION SYSTEM WITH A LOWER CRITICAL SOLUTION TEMPERATURE UNDER A POWERFUL LOCAL HEAT IMPACT. EXPERIMENTAL METHODOLOGY
The paper describes a methodology for the experimental study of a powerful heat release in a microsized probe immersed in a two-component solution with a lower critical solution temperature. Experimental data on superheating relative to the liquid–liquid spinodal and thermal impact on the stability of the system for a water–PPG-425 solution are presented. The following conclusion is made for a solution whose near-critical mass fraction of PPG-425 is 30%: despite the high density of the heat flux through the heater surface (9.2–13.7 MW/m2), its temperature stabilizes at a value exceeding the equilibrium temperature of the liquid–liquid system by approximately 150 K. It is shown that the heat exchange process is stable against changes in the heating parameters: the nature of heat transfer by the solution remains the same. It is revealed that the heat transfer coefficient is several times greater than the corresponding value obtained for water.
- 1 August 2024
- Published by Pleiades Publishing Ltd in Journal of Applied Mechanics and Technical Physics
- Vol. 65 (4) , 771-783
RESPONSE OF A MICROHEATER–SOLUTION SYSTEM WITH A LOWER CRITICAL SOLUTION TEMPERATURE UNDER A POWERFUL LOCAL HEAT IMPACT. EXPERIMENTAL METHODOLOGY
The paper describes a methodology for the experimental study of a powerful heat release in a microsized probe immersed in a two-component solution with a lower critical solution temperature. Experimental data on superheating relative to the liquid–liquid spinodal and thermal impact on the stability of the system for a water–PPG-425 solution are presented. The following conclusion is made for a solution whose near-critical mass fraction of PPG-425 is 30%: despite the high density of the heat flux through the heater surface (9.2–13.7 MW/m2), its temperature stabilizes at a value exceeding the equilibrium temperature of the liquid–liquid system by approximately 150 K. It is shown that the heat exchange process is stable against changes in the heating parameters: the nature of heat transfer by the solution remains the same. It is revealed that the heat transfer coefficient is several times greater than the corresponding value obtained for water.
- 1 December 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (12) , 124708
Voltage-controlled precision electronic power regulator
The architecture of a novel electronic power regulator, which allows a set value of constant power on a wire probe to be maintained, is presented. A gain in the negative feedback loop of ≈2 · 103 allows the set power value in the series of pulses to be accurately maintained at the level of 99.95% (proximity 0.05). In order to study short term processes, the response time of the described regulator is in the order of 2 μs. The created architecture is easily scalable for various tasks, ranging from the well-known transient hot-wire method to other applications, examples of which are given in this article (unsteady heat transfer in supercritical-pressure fluids and unstable mixtures having lower critical solution temperature). A comparison of the presented controller architecture with the previously described solutions from the point of view of operational stability is given.
- 1 December 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (12) , 124708
Voltage-controlled precision electronic power regulator
The architecture of a novel electronic power regulator, which allows a set value of constant power on a wire probe to be maintained, is presented. A gain in the negative feedback loop of ≈2 · 103 allows the set power value in the series of pulses to be accurately maintained at the level of 99.95% (proximity 0.05). In order to study short term processes, the response time of the described regulator is in the order of 2 μs. The created architecture is easily scalable for various tasks, ranging from the well-known transient hot-wire method to other applications, examples of which are given in this article (unsteady heat transfer in supercritical-pressure fluids and unstable mixtures having lower critical solution temperature). A comparison of the presented controller architecture with the previously described solutions from the point of view of operational stability is given.
- 14 September 2021
- Published by Pleiades Publishing Ltd in Instruments and Experimental Techniques
- Vol. 64 (5) , 781-784
An Apparatus for Studying Nonstationary Heat Exchange in Liquid Media
An apparatus is described for studying unsteady heat transfer in various liquid media by the method of controlled heating of a thin wire probe. The main link of the setup is a high-speed electronic regulator that controls the power dissipated by the probe depending on the control voltage at the regulator input. The main parameters of the apparatus are: the probe is a 1-cm-long 20-μm platinum wire and the controller response time is ≈1–2 μs, the accuracy of maintaining the power value is 0.05%, the heating time is 1–500 ms, and the heat flux density from the probe surface is up to 20 MW/m2. A measurement technique is presented and an example of using a setup for studying the spinodal decomposition of an aqueous solution of polypropylene glycol (PPG-425), which has a lower critical dissolution temperature, is provided.
- 14 September 2021
- Published by Pleiades Publishing Ltd in Instruments and Experimental Techniques
- Vol. 64 (5) , 781-784
An Apparatus for Studying Nonstationary Heat Exchange in Liquid Media
An apparatus is described for studying unsteady heat transfer in various liquid media by the method of controlled heating of a thin wire probe. The main link of the setup is a high-speed electronic regulator that controls the power dissipated by the probe depending on the control voltage at the regulator input. The main parameters of the apparatus are: the probe is a 1-cm-long 20-μm platinum wire and the controller response time is ≈1–2 μs, the accuracy of maintaining the power value is 0.05%, the heating time is 1–500 ms, and the heat flux density from the probe surface is up to 20 MW/m2. A measurement technique is presented and an example of using a setup for studying the spinodal decomposition of an aqueous solution of polypropylene glycol (PPG-425), which has a lower critical dissolution temperature, is provided.
- Open Access
Investigation of Binary Liquids in Unstable States—An Experimental Approach
In this article, we present a methodology for conducting measurements based on pulse heating of a wire probe in partially soluble binary liquids. These liquids, which can be rapidly transferred to the region of unstable states above the diffusional spinodal, are novel research objects for the thermophysics of extreme states. Using the example of aqueous solutions of polypropylene glycol and glycol monobutyl ether having a lower critical solution temperature, the key hypothesis of the study on the general measurability of the properties of unstable solutions has been confirmed. The characteristic heating times from 1 to 15 milliseconds corresponded to the thickness of the heated layer comprising a few micrometers. The pressure was varied from units of MPa to 100 MPa. The conditions for the transition from measurements on pure components to those on solutions are formulated. The characteristic thermal patterns of the decay of unstable states depending on pressure and heating rate are revealed. The general possibility of using partially soluble binary liquids as a promising coolant in processes involving powerful local heat release is demonstrated.
Open AccessInvestigation of Binary Liquids in Unstable States—An Experimental Approach
In this article, we present a methodology for conducting measurements based on pulse heating of a wire probe in partially soluble binary liquids. These liquids, which can be rapidly transferred to the region of unstable states above the diffusional spinodal, are novel research objects for the thermophysics of extreme states. Using the example of aqueous solutions of polypropylene glycol and glycol monobutyl ether having a lower critical solution temperature, the key hypothesis of the study on the general measurability of the properties of unstable solutions has been confirmed. The characteristic heating times from 1 to 15 milliseconds corresponded to the thickness of the heated layer comprising a few micrometers. The pressure was varied from units of MPa to 100 MPa. The conditions for the transition from measurements on pure components to those on solutions are formulated. The characteristic thermal patterns of the decay of unstable states depending on pressure and heating rate are revealed. The general possibility of using partially soluble binary liquids as a promising coolant in processes involving powerful local heat release is demonstrated.
- 9 December 2020
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2313 (1) , 030046
Non-stationary heat transfer beyond diffusion spinodal of a solution
In recent years, problems connected with the enhancement of heat transfer have come to the forefront of thermophysical research. One of the current approaches to this problem consists in the search for partially-soluble additives to the liquid heat carrier combined with an optimisation of the thermal conditions in which these additives provide a significant effect. In this report, the thermal response characteristics of a solution of water and polypropylene glycol (PPG-425), having a lower critical solution temperature (LCST), used to facilitate powerful heat dissipation, are discussed. The method of controlled pulse heating of a wire probe was applied. An analysis of the energy values transferred from the probe to the solution in a particular heat release mode showed that, for a solution with 20-30% content of PPG, these values exceed the corresponding values for pure water by an order of magnitude. This result can serve as a basis for the search of a new generation of coolants for processes in which powerful heat generation is possible.
- 9 December 2020
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2313 (1) , 030046
Non-stationary heat transfer beyond diffusion spinodal of a solution
In recent years, problems connected with the enhancement of heat transfer have come to the forefront of thermophysical research. One of the current approaches to this problem consists in the search for partially-soluble additives to the liquid heat carrier combined with an optimisation of the thermal conditions in which these additives provide a significant effect. In this report, the thermal response characteristics of a solution of water and polypropylene glycol (PPG-425), having a lower critical solution temperature (LCST), used to facilitate powerful heat dissipation, are discussed. The method of controlled pulse heating of a wire probe was applied. An analysis of the energy values transferred from the probe to the solution in a particular heat release mode showed that, for a solution with 20-30% content of PPG, these values exceed the corresponding values for pure water by an order of magnitude. This result can serve as a basis for the search of a new generation of coolants for processes in which powerful heat generation is possible.
- 17 February 2020
- Published by Pleiades Publishing Ltd in Journal of Engineering Thermophysics
- Vol. 29 (1) , 67-74
Title High-Power Heat Release in Supercritical Water: Insight into the Heat Transfer Deterioration Problem
The investigation is focused on the phenomenon of heat transfer deterioration (HTD), inhibiting the use of supercritical fluids in the processes in which high-power local heat release is possible. The ordinary discussion is based solely on the data of quasi-stationary measurements. In order to clarify the intrinsic nature of HTD as an essentially non-stationary phenomenon, it is worthwhile to take into account the peculiarities of heat transfer confined in time and space. In the present paper, we briefly discuss the characteristic features of such heat transfer in supercritical water. The characteristic heating time was \(10^{-3}\div 10^{-2}\) s and the heat flux density through the wall increased up to 15 MW/m\(^{2}\). The results provide the heat transfer pattern under conditions of predominance of the heat conduction mode. Exactly this mode most closely corresponds to the regime of high-power local heat release in a viscous sublayer. We also propose that the effect of threshold decrease in the heat transfer intensity (typical of pulse processes in supercritical transitions) may be a fundamental factor for occurrence of the HTD mode.- 17 February 2020
- Published by Pleiades Publishing Ltd in Journal of Engineering Thermophysics
- Vol. 29 (1) , 67-74
Title High-Power Heat Release in Supercritical Water: Insight into the Heat Transfer Deterioration Problem
The investigation is focused on the phenomenon of heat transfer deterioration (HTD), inhibiting the use of supercritical fluids in the processes in which high-power local heat release is possible. The ordinary discussion is based solely on the data of quasi-stationary measurements. In order to clarify the intrinsic nature of HTD as an essentially non-stationary phenomenon, it is worthwhile to take into account the peculiarities of heat transfer confined in time and space. In the present paper, we briefly discuss the characteristic features of such heat transfer in supercritical water. The characteristic heating time was \(10^{-3}\div 10^{-2}\) s and the heat flux density through the wall increased up to 15 MW/m\(^{2}\). The results provide the heat transfer pattern under conditions of predominance of the heat conduction mode. Exactly this mode most closely corresponds to the regime of high-power local heat release in a viscous sublayer. We also propose that the effect of threshold decrease in the heat transfer intensity (typical of pulse processes in supercritical transitions) may be a fundamental factor for occurrence of the HTD mode.- 1 December 2013
- Published by Pleiades Publishing Ltd in Russian Journal of Physical Chemistry B
- Vol. 7 (8) , 943-949
Heat transfer under supercritical parameters of pulse-heated liquid
A technique based on pulse heating of a wire probe (resistance thermometer) in a constant-heating power regime is developed and used for studies of comparative heat-transfer intensity in supercritical fluids (SCFs) in the pressure and temperature ranges from 1p c to 4–6p c and from 0.6T c to 1.6T c , respectively (p c and T c are critical pressure and temperature). The characteristic parameters of the setup used are as follows: heating -pulse length, 1–10 ms; density of heat flux through the probe surface, 1–10 MW/m2; and repeatability of the selected power value in a series of pulses, not worse than 0.1%. A sharp decrease in the heat-transfer intensity in SCFs compared to that observed at subcritical temperatures is revealed.
- 1 December 2013
- Published by Pleiades Publishing Ltd in Russian Journal of Physical Chemistry B
- Vol. 7 (8) , 943-949
Heat transfer under supercritical parameters of pulse-heated liquid
A technique based on pulse heating of a wire probe (resistance thermometer) in a constant-heating power regime is developed and used for studies of comparative heat-transfer intensity in supercritical fluids (SCFs) in the pressure and temperature ranges from 1p c to 4–6p c and from 0.6T c to 1.6T c , respectively (p c and T c are critical pressure and temperature). The characteristic parameters of the setup used are as follows: heating -pulse length, 1–10 ms; density of heat flux through the probe surface, 1–10 MW/m2; and repeatability of the selected power value in a series of pulses, not worse than 0.1%. A sharp decrease in the heat-transfer intensity in SCFs compared to that observed at subcritical temperatures is revealed.
- 4 May 2012
- Published by Pleiades Publishing Ltd in Journal of Engineering Thermophysics
- Vol. 21 (2) , 144-153
Apparatus for studying heat transfer in nanofluids under high-power heating
A technique of electronic control of the probe heating power is developed using the method of controlled pulse heating of a wire probe, that is a resistance thermometer, was developed. An apparatus implementing this technique was fabricated. The characteristic parameters of the apparatus are as follows: the heating pulse length, 1 to 10 ms; the heat flux density through the surface of a 20 µm probe, 1 to 10 MW/m2; repeatability of selected power value in a series of pulses is on a level of 0.05%. As an example, the constant heating power mode is applied for comparing the thermal resistance of nanofluids in the region of stable states of liquid and superheated (with respect to the liquid-vapor equilibrium temperature of the base liquid) ones. The parameter was the content of Al2O3 nanoparticles in the base liquid (isopropanol).
- 4 May 2012
- Published by Pleiades Publishing Ltd in Journal of Engineering Thermophysics
- Vol. 21 (2) , 144-153
Apparatus for studying heat transfer in nanofluids under high-power heating
A technique of electronic control of the probe heating power is developed using the method of controlled pulse heating of a wire probe, that is a resistance thermometer, was developed. An apparatus implementing this technique was fabricated. The characteristic parameters of the apparatus are as follows: the heating pulse length, 1 to 10 ms; the heat flux density through the surface of a 20 µm probe, 1 to 10 MW/m2; repeatability of selected power value in a series of pulses is on a level of 0.05%. As an example, the constant heating power mode is applied for comparing the thermal resistance of nanofluids in the region of stable states of liquid and superheated (with respect to the liquid-vapor equilibrium temperature of the base liquid) ones. The parameter was the content of Al2O3 nanoparticles in the base liquid (isopropanol).