MSMichael Salerno

Michael Salerno

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Michael Salerno has a total of 30 co-authors. Here are the top co-authors by number of shared publications:

  • Christopher M. Kramer

    2 Cardiovascular Division, Department of Medicine, University of Virginia Health System, Charlottesville, VA, United States

    4 shared publications
  • Yang Yang

    4 BioMedical Engineering and Imaging Institute, Icahn School of Medicine at Mount Sinai, New York, NY, United States

    3 shared publications
  • Junyu Wang

    Department of Cardiovascular Medicine Stanford University Stanford California USA

    2 shared publications
  • Adrián I. Löffler

    3 UCHealth Heart and Vascular Clinic, Greeley Medical Center, Greeley, CO, United States

    1 shared publication
  • Angela M. Taylor

    Department of Medicine, Cardiovascular Division, University of Virginia Health System, Charlottesville, Virginia, USA

    1 shared publication
  • Connor Siggins

    1 Department of Chemistry, University of Virginia, Charlottesville, VA, United States

    1 shared publication

Latest Publications

  • Ironing It Out

    by Kevin Kai Li, Michael Salerno

  • Open Access

    Cardiometabolic biomarker patterns associated with cardiac MRI defined fibrosis and microvascular dysfunction in patients with heart failure with preserved ejection fraction

    by Connor Siggins, Jonathan A. Pan, Adrián I. Löffler, Yang Yang, Peter W. Shaw, Pelbreton C. Balfour, Frederick H. Epstein, Li-Ming Gan, Christopher M. Kramer, Ellen C. Keeley, et al.

    Introduction: Heart failure with preserved ejection fraction (HFpEF) is a complex disease process influenced by metabolic disorders, systemic inflammation, myocardial fibrosis, and microvascular dysfunction. The goal of our study is to identify potential relationships between plasma biomarkers and cardiac magnetic resonance (CMR) imaging markers in patients with HFpEF.Methods: Nineteen subjects with HFpEF and 15 age-matched healthy controls were enrolled and underwent multiparametric CMR and plasma biomarker analysis using the Olink® Cardiometabolic Panel (Olink Proteomics, Uppsala, Sweden). Partial least squares discriminant analysis (PLS-DA) was used to characterize CMR and biomarker variables that differentiate the subject groups into two principal components. Orthogonal projection to latent structures by partial least squares (OPLS) analysis was used to identify biomarker patterns that correlate with myocardial perfusion reserve (MPR) and extracellular volume (ECV) mapping.Results: A PLS-DA could differentiate between HFpEF and normal controls with two significant components explaining 79% (Q2 = 0.47) of the differences. For OPLS, there were 7 biomarkers that significantly correlated with ECV (R2 = 0.85, Q = 0.53) and 6 biomarkers that significantly correlated with MPR (R2 = 0.92, Q2 = 0.32). Only 1 biomarker significantly correlated with both ECV and MPR.Discussion: Patients with HFpEF have unique imaging and biomarker patterns that suggest mechanisms associated with metabolic disease, inflammation, fibrosis and microvascular dysfunction.


  • High‐resolution spiral real‐time cardiac cine imaging with deep learning‐based rapid image reconstruction and quantification

    by Junyu Wang, Marina Awad, Ruixi Zhou, Zhixing Wang, Xitong Wang, Xue Feng, Yang Yang, Craig Meyer, Christopher M. Kramer, Michael Salerno

    The objective of the current study was to develop and evaluate a DEep learning‐based rapid Spiral Image REconstruction (DESIRE) and deep learning (DL)‐based segmentation approach to quantify the left ventricular ejection fraction (LVEF) for high‐resolution spiral real‐time cine imaging, including 2D balanced steady‐state free precession imaging at 1.5 T and gradient echo (GRE) imaging at 1.5 and 3 T. A 3D U‐Net–based image reconstruction network and 2D U‐Net–based image segmentation network were proposed and evaluated. Low‐rank plus sparse (L+S) served as the reference for the image reconstruction network and manual contouring of the left ventricle was the reference of the segmentation network. To assess the image reconstruction quality, structural similarity index, peak signal‐to‐noise ratio, normalized root‐mean‐square error, and blind grading by two experienced cardiologists (5: excellent; 1: poor) were performed. To assess the segmentation performance, quantification of the LVEF on GRE imaging at 3 T was compared with the quantification from manual contouring. Excellent performance was demonstrated by the proposed technique. In terms of image quality, there was no difference between L+S and the proposed DESIRE technique. For quantification analysis, the proposed DL method was not different to the manual segmentation method (p > 0.05) in terms of quantification of LVEF. The reconstruction time for DESIRE was ~32 s (including nonuniform fast Fourier transform [NUFFT]) per dynamic series (40 frames), while the reconstruction time of L+S with GPU acceleration was approximately 3 min. The DL segmentation takes less than 5 s. In conclusion, the proposed DL‐based image reconstruction and quantification techniques enabled 1‐min image reconstruction for the whole heart and quantification with automatic reconstruction and quantification of the left ventricle function for high‐resolution spiral real‐time cine imaging with excellent performance.


  • Seeing the Unseen in Cardiac Remodeling

    by Daniel B. Ennis, Michael Salerno

  • Open Access

    Free‐breathing self‐gated continuous‐IR spiral T1 mapping: Comparison of dual flip‐angle and Bloch‐Siegert B1‐corrected techniques

    by Ruixi Zhou, Junyu Wang, Daniel S. Weller, Yang Yang, John P. Mugler, Michael Salerno

    Purpose: To develop a B1‐corrrected single flip‐angle continuous acquisition strategy with free‐breathing and cardiac self‐gating for spiral T1 mapping, and compare it to a previous dual flip‐angle technique.Methods: Data were continuously acquired using a spiral‐out trajectory, rotated by the golden angle in time. During the first 2 s, off‐resonance Fermi RF pulses were applied to generate a Bloch‐Siegert shift B1 map, and the subsequent data were acquired with an inversion RF pulse applied every 4 s to create a T1* map. The final T1 map was generated from the B1 and the T1* maps by using a look‐up table that accounted for slice profile effects, yielding more accurate T1 values. T1 values were compared to those from inversion recovery (IR) spin echo (phantom only), MOLLI, SAturation‐recovery single‐SHot Acquisition (SASHA), and previously proposed dual flip‐angle results. This strategy was evaluated in a phantom and 25 human subjects.Results: The proposed technique showed good agreement with IR spin‐echo results in the phantom experiment. For in‐vivo studies, the proposed technique and the previously proposed dual flip‐angle method were more similar to SASHA results than to MOLLI results.Conclusions: B1‐corrected single flip‐angle T1 mapping successfully acquired B1 and T1 maps in a free‐breathing, continuous‐IR spiral acquisition, providing a method with improved accuracy to measure T1 using a continuous Look‐Locker acquisition, as compared to the previously proposed dual excitation flip‐angle technique.


  • Cardiovascular Imaging for Ischemic Heart Disease in Women

    by Patricia F. Rodriguez Lozano, Elona Rrapo Kaso, Jamieson M. Bourque, Mohamed Morsy, Angela M. Taylor, Todd C. Villines, Christopher M. Kramer, Michael Salerno


  • DEep learning‐based rapid Spiral Image REconstruction (DESIRE) for high‐resolution spiral first‐pass myocardial perfusion imaging

    by Junyu Wang, Daniel S. Weller, Christopher M. Kramer, Michael Salerno

    The objective of the current study was to develop and evaluate a DEep learning‐based rapid Spiral Image REconstruction (DESIRE) technique for high‐resolution spiral first‐pass myocardial perfusion imaging with whole‐heart coverage, to provide fast and accurate image reconstruction for both single‐slice (SS) and simultaneous multislice (SMS) acquisitions. Three‐dimensional U‐Net–based image enhancement architectures were evaluated for high‐resolution spiral perfusion imaging at 3 T. The SS and SMS MB = 2 networks were trained on SS perfusion images from 156 slices from 20 subjects. Structural similarity index (SSIM), peak signal‐to‐noise ratio (PSNR), and normalized root mean square error (NRMSE) were assessed, and prospective images were blindly graded by two experienced cardiologists (5: excellent; 1: poor). Excellent performance was demonstrated for the proposed technique. For SS, SSIM, PSNR, and NRMSE were 0.977 [0.972, 0.982], 42.113 [40.174, 43.493] dB, and 0.102 [0.080, 0.125], respectively, for the best network. For SMS MB = 2 retrospective data, SSIM, PSNR, and NRMSE were 0.961 [0.950, 0.969], 40.834 [39.619, 42.004] dB, and 0.107 [0.086, 0.133], respectively, for the best network. The image quality scores were 4.5 [4.1, 4.8], 4.5 [4.3, 4.6], 3.5 [3.3, 4], and 3.5 [3.3, 3.8] for SS DESIRE, SS L1‐SPIRiT, MB = 2 DESIRE, and MB = 2 SMS‐slice‐L1‐SPIRiT, respectively, showing no statistically significant difference (p = 1 and p = 1 for SS and SMS, respectively) between L1‐SPIRiT and the proposed DESIRE technique. The network inference time was ~100 ms per dynamic perfusion series with DESIRE, while the reconstruction time of L1‐SPIRiT with GPU acceleration was ~ 30 min. It was concluded that DESIRE enabled fast and high‐quality image reconstruction for both SS and SMS MB = 2 whole‐heart high‐resolution spiral perfusion imaging.