High‐resolution spiral real‐time cardiac cine imaging with deep learning‐based rapid image reconstruction and quantification
- 5 November 2023
- journal article
- research article
- Published by Wiley in NMR in Biomedicine
- Vol. 37 (2) , e5051
Abstract
The objective of the current study was to develop and evaluate a DEep learning‐based rapid Spiral Image REconstruction (DESIRE) and deep learning (DL)‐based segmentation approach to quantify the left ventricular ejection fraction (LVEF) for high‐resolution spiral real‐time cine imaging, including 2D balanced steady‐state free precession imaging at 1.5 T and gradient echo (GRE) imaging at 1.5 and 3 T. A 3D U‐Net–based image reconstruction network and 2D U‐Net–based image segmentation network were proposed and evaluated. Low‐rank plus sparse (L+S) served as the reference for the image reconstruction network and manual contouring of the left ventricle was the reference of the segmentation network. To assess the image reconstruction quality, structural similarity index, peak signal‐to‐noise ratio, normalized root‐mean‐square error, and blind grading by two experienced cardiologists (5: excellent; 1: poor) were performed. To assess the segmentation performance, quantification of the LVEF on GRE imaging at 3 T was compared with the quantification from manual contouring. Excellent performance was demonstrated by the proposed technique. In terms of image quality, there was no difference between L+S and the proposed DESIRE technique. For quantification analysis, the proposed DL method was not different to the manual segmentation method (p > 0.05) in terms of quantification of LVEF. The reconstruction time for DESIRE was ~32 s (including nonuniform fast Fourier transform [NUFFT]) per dynamic series (40 frames), while the reconstruction time of L+S with GPU acceleration was approximately 3 min. The DL segmentation takes less than 5 s. In conclusion, the proposed DL‐based image reconstruction and quantification techniques enabled 1‐min image reconstruction for the whole heart and quantification with automatic reconstruction and quantification of the left ventricle function for high‐resolution spiral real‐time cine imaging with excellent performance.Keywords
Funding Information
- Wallace H. Coulter Foundation
- National Institutes of Health (R01 HL131919, HL155962)
This publication has 29 references indexed in Scilit:
- U-Net: Convolutional Networks for Biomedical Image Segmentation2015
- Low-rank plus sparse matrix decomposition for accelerated dynamic MRI with separation of background and dynamic componentsMagnetic Resonance in Medicine, 2014
- Highly accelerated real‐time cardiac cine MRI using k–t SPARSE‐SENSEMagnetic Resonance in Medicine, 2012
- Real‐time MRI at a resolution of 20 msNMR in Biomedicine, 2010
- Image quality assessment: from error visibility to structural similarityIEEE Transactions on Image Processing, 2004
- Assessment of Myocardial Function with Interactive Non–Breath-hold Real-time MR Imaging: Comparison with Echocardiography and Breath-hold Cine MR ImagingRadiology, 2004
- Real‐time cardiac MRI at 3 teslaMagnetic Resonance in Medicine, 2004
- Self‐gated cardiac cine MRIMagnetic Resonance in Medicine, 2003
- Cardiac Function: MR Evaluation in One Breath Hold with Real-time True Fast Imaging with Steady-State PrecessionRadiology, 2002
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986