Xiaoqi Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Xiaoqi Zhang has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Guoyuan Li
Department of Orthopedics, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, 230001, Anhui, China
2 shared publications Xiaofeng Ji
Department of Orthopedics, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, 230001, Anhui, China
2 shared publications- Xifu Shang
Cheeloo College of Medicine, Shandong University, Jinan, 250012, Shandong, China.
2 shared publications - Zhengliang Luo
Department of Orthopedics, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, 230001, Anhui, China
2 shared publications - Chen Zhu
Department of Orthopedics, Centre for Leading Medicine and Advanced Technologies of IHM, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, China
1 shared publication Fei Hu
Department of Orthopaedics, Affiliated Provincial Hospital of Anhui Medical University, Hefei, Anhui, China
1 shared publication
Latest Publications
- Open Access
- 7 August 2025
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 26 (1) , 758
Biomechanical evaluation of bispherical augments in acetabular defect reconstruction and comparative study of different fixation methods
Novel bispherical augments developed for acetabular defect reconstruction, which combined with acetabular components, have shown excellent results in clinical follow-up. This study aims to evaluate the primary stability of them in severe acetabular defect reconstruction and biomechanical effect using different combine methods in the component-augment interface, and to further explain their value in clinical applications. Nine composite hemipelvis specimens were prepared with a Paprosky II defect. A porous titanium acetabular shell and bispherical augment were combined and implanted for acetabular defect reconstruction. The augment was fixed to the hemipelvis using screws, while three specimens per groups of three groups were varied by different fixation techniques between the augments and acetabular components: (1) screw fixation only, (2) cement fixation only, and (3) screw and cement fixation. The combined components and hemi pelvic specimens were cyclically loaded (500 cycles) with three different levels of loads (maximum 0.5 kN, 0.9 kN, and 1.8 kN). All constructs had micromotions of less than 99 μm, and bony ingrowth could be achieved between the prostheses and the bone in 3-30% and 5-50% loads. The cement groups showed the maximum relative movement in the interface between the bone and combined prosthesis, especially when the load was increased to 1.8 kN (100%), while in which the hybrid groups had the minimum value. The study indicates that acetabular defect reconstruction utilizing the bispherical augments can achieve excellent primary stability, which provides the mechanical condition of bone ingrowth for prostheses and augments. The hybrid fixation is the most reliable of them, even under full loads.
- 7 August 2025
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 26 (1) , 758
Open AccessBiomechanical evaluation of bispherical augments in acetabular defect reconstruction and comparative study of different fixation methods
Novel bispherical augments developed for acetabular defect reconstruction, which combined with acetabular components, have shown excellent results in clinical follow-up. This study aims to evaluate the primary stability of them in severe acetabular defect reconstruction and biomechanical effect using different combine methods in the component-augment interface, and to further explain their value in clinical applications. Nine composite hemipelvis specimens were prepared with a Paprosky II defect. A porous titanium acetabular shell and bispherical augment were combined and implanted for acetabular defect reconstruction. The augment was fixed to the hemipelvis using screws, while three specimens per groups of three groups were varied by different fixation techniques between the augments and acetabular components: (1) screw fixation only, (2) cement fixation only, and (3) screw and cement fixation. The combined components and hemi pelvic specimens were cyclically loaded (500 cycles) with three different levels of loads (maximum 0.5 kN, 0.9 kN, and 1.8 kN). All constructs had micromotions of less than 99 μm, and bony ingrowth could be achieved between the prostheses and the bone in 3-30% and 5-50% loads. The cement groups showed the maximum relative movement in the interface between the bone and combined prosthesis, especially when the load was increased to 1.8 kN (100%), while in which the hybrid groups had the minimum value. The study indicates that acetabular defect reconstruction utilizing the bispherical augments can achieve excellent primary stability, which provides the mechanical condition of bone ingrowth for prostheses and augments. The hybrid fixation is the most reliable of them, even under full loads.
- 15 June 2020
- Vol. 34 (6) , 683-688
[Effectiveness of proximal femur reconstruction combined with total hip arthroplasty for Crowe type Ⅳ developmental dysplasia of hip].
To investigate the early effectiveness of proximal femur reconstruction combined with total hip arthroplasty (THA) in the treatment of adult Crowe type Ⅳ developmental dysplasia of the hip (DDH). Between May 2015 and March 2018, 29 cases (33 hips) suffering from Crowe type Ⅳ DDH were treated with proximal femur reconstruction combined with THA. Of the 29 cases, there were 6 males (7 hips) and 23 females (26 hips), aged from 24 to 74 years with an average age of 44.9 years. The preoperative Harris hip score was 44.0±12.0. Gait abnormalities were found in all of the 33 hips with positive Trendelenburg sign, and the lower limb discrepancy was (3.8±1.6) cm. Preoperative X-ray films and CT both indicated serious anatomical abnormalities, including complete dislocation of the affected hip with significant move-up of the greater trochanter, abnormal development of the femoral neck, abnormal anterversion angle and neck-shaft angle, dysplasia of proximal femur and dysplasia of medullary cavity. The operation time, intraoperative blood loss, transfusion rate, and complications were recorded. The Gruen and DeLee-Charnley zoning methods were used to evaluate the aseptic loosening of the prosthesis on X-ray films. The Harris score was used to evaluate hip function. The lower limb discrepancy was calculated and compared with the preoperative value. The operation time ranged from 80 to 240 minutes, with an average of 124.8 minutes. The intraoperative blood loss ranged from 165 to 1 300 mL, with an average of 568.4 mL. Seventeen patients (51.5%) received blood transfusion treatment. All the incisions healed by first intention without infection or deep vein thrombosis. All patients were followed up 19-53 months, with an average of 33 months. One patient had posterior hip dislocation because of falling from the bed at 4 weeks after operation, and was treated with manual reduction and fixation with abduction brace for 4 weeks, and no dislocation occurred during next 12-month follow-up. Two patients developed sciatic nerve palsy of the affected limbs after operation and were treated with mecobalamin, and recovered completely at 12 weeks later. Trendelenburg sign was positive in 3 patients and mild claudication occurred in 4 patients after operation. X-ray films showed that all the osteotomy sites healed at 3-6 months after operation, and no wire fracture was observed during the follow-up. The Harris score was 89.8±2.8 and lower limb discrepancy was (0.6±0.4) cm at last follow-up, both improved significantly ( t=-22.917, P=0.000; t=11.958, P=0.000). The prosthesis of femur and acetabulum showed no obvious loosening and displacement, and achieved good bone ingrowth except 2 patients who had local osteolysis in the area of Gruen 1 and 7 around the femoral prosthesis, but no sign of loosening and sinking was observed. The treatment of Crowe Ⅳ DDH with proximal femur reconstruction and THA was satisfactory in the early postoperative period. The reconstruction technique of proximal femur can effectively restore the anatomical structure of proximal femur, which is one of the effective methods to deal with the deformity of proximal femur.
- 15 June 2020
- Vol. 34 (6) , 683-688
[Effectiveness of proximal femur reconstruction combined with total hip arthroplasty for Crowe type Ⅳ developmental dysplasia of hip].
To investigate the early effectiveness of proximal femur reconstruction combined with total hip arthroplasty (THA) in the treatment of adult Crowe type Ⅳ developmental dysplasia of the hip (DDH). Between May 2015 and March 2018, 29 cases (33 hips) suffering from Crowe type Ⅳ DDH were treated with proximal femur reconstruction combined with THA. Of the 29 cases, there were 6 males (7 hips) and 23 females (26 hips), aged from 24 to 74 years with an average age of 44.9 years. The preoperative Harris hip score was 44.0±12.0. Gait abnormalities were found in all of the 33 hips with positive Trendelenburg sign, and the lower limb discrepancy was (3.8±1.6) cm. Preoperative X-ray films and CT both indicated serious anatomical abnormalities, including complete dislocation of the affected hip with significant move-up of the greater trochanter, abnormal development of the femoral neck, abnormal anterversion angle and neck-shaft angle, dysplasia of proximal femur and dysplasia of medullary cavity. The operation time, intraoperative blood loss, transfusion rate, and complications were recorded. The Gruen and DeLee-Charnley zoning methods were used to evaluate the aseptic loosening of the prosthesis on X-ray films. The Harris score was used to evaluate hip function. The lower limb discrepancy was calculated and compared with the preoperative value. The operation time ranged from 80 to 240 minutes, with an average of 124.8 minutes. The intraoperative blood loss ranged from 165 to 1 300 mL, with an average of 568.4 mL. Seventeen patients (51.5%) received blood transfusion treatment. All the incisions healed by first intention without infection or deep vein thrombosis. All patients were followed up 19-53 months, with an average of 33 months. One patient had posterior hip dislocation because of falling from the bed at 4 weeks after operation, and was treated with manual reduction and fixation with abduction brace for 4 weeks, and no dislocation occurred during next 12-month follow-up. Two patients developed sciatic nerve palsy of the affected limbs after operation and were treated with mecobalamin, and recovered completely at 12 weeks later. Trendelenburg sign was positive in 3 patients and mild claudication occurred in 4 patients after operation. X-ray films showed that all the osteotomy sites healed at 3-6 months after operation, and no wire fracture was observed during the follow-up. The Harris score was 89.8±2.8 and lower limb discrepancy was (0.6±0.4) cm at last follow-up, both improved significantly ( t=-22.917, P=0.000; t=11.958, P=0.000). The prosthesis of femur and acetabulum showed no obvious loosening and displacement, and achieved good bone ingrowth except 2 patients who had local osteolysis in the area of Gruen 1 and 7 around the femoral prosthesis, but no sign of loosening and sinking was observed. The treatment of Crowe Ⅳ DDH with proximal femur reconstruction and THA was satisfactory in the early postoperative period. The reconstruction technique of proximal femur can effectively restore the anatomical structure of proximal femur, which is one of the effective methods to deal with the deformity of proximal femur.
- Open Access
- 1 February 2017
- Published by Elsevier in Arthroplasty Today
- Vol. 3 (4) , 251-252
A simple technique to remove well-fixed acetabular components in revision of total hip arthroplasty
- 1 February 2017
- Published by Elsevier in Arthroplasty Today
- Vol. 3 (4) , 251-252
Open AccessA simple technique to remove well-fixed acetabular components in revision of total hip arthroplasty