Biomechanical evaluation of bispherical augments in acetabular defect reconstruction and comparative study of different fixation methods
Open Access
- 7 August 2025
- journal article
- research article
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 26 (1) , 758
Abstract
Novel bispherical augments developed for acetabular defect reconstruction, which combined with acetabular components, have shown excellent results in clinical follow-up. This study aims to evaluate the primary stability of them in severe acetabular defect reconstruction and biomechanical effect using different combine methods in the component-augment interface, and to further explain their value in clinical applications. Nine composite hemipelvis specimens were prepared with a Paprosky II defect. A porous titanium acetabular shell and bispherical augment were combined and implanted for acetabular defect reconstruction. The augment was fixed to the hemipelvis using screws, while three specimens per groups of three groups were varied by different fixation techniques between the augments and acetabular components: (1) screw fixation only, (2) cement fixation only, and (3) screw and cement fixation. The combined components and hemi pelvic specimens were cyclically loaded (500 cycles) with three different levels of loads (maximum 0.5 kN, 0.9 kN, and 1.8 kN). All constructs had micromotions of less than 99 μm, and bony ingrowth could be achieved between the prostheses and the bone in 3-30% and 5-50% loads. The cement groups showed the maximum relative movement in the interface between the bone and combined prosthesis, especially when the load was increased to 1.8 kN (100%), while in which the hybrid groups had the minimum value. The study indicates that acetabular defect reconstruction utilizing the bispherical augments can achieve excellent primary stability, which provides the mechanical condition of bone ingrowth for prostheses and augments. The hybrid fixation is the most reliable of them, even under full loads.Keywords
Funding Information
- the Joint Fund for Medical Artificial Intelligence (MAI2023Q027)
- the Natural Science Foundation of Anhui Province (2308085MH251)
- Hefei Comprehensive National Science Center (2023IHM01075)
- The National Natural Science Foundation of China (82072408)
This publication has 36 references indexed in Scilit:
- Promising Mid-term Results With a Cup-cage Construct for Large Acetabular Defects and Pelvic DiscontinuityClinical Orthopaedics and Related Research, 2016
- Continued Good Results With Modular Trabecular Metal Augments for Acetabular Defects in Hip Arthroplasty at 7 to 11 YearsClinical Orthopaedics and Related Research, 2015
- Effect of High Hip Center on Stress for Dysplastic HipOrthopedics, 2014
- Mechanical properties of a cemented porous implant interfaceActa Orthopaedica, 2014
- Composite Bone Models in Orthopaedic Surgery Research and EducationJournal of the American Academy of Orthopaedic Surgeons, 2014
- Loosening After Acetabular Revision: Comparison of Trabecular Metal and Reinforcement Rings. A Systematic ReviewThe Journal of Arthroplasty, 2014
- Realistic loads for testing hip implantsBio-Medical Materials and Engineering, 2010
- The operation of the century: total hip replacementThe Lancet, 2007
- Hip contact forces and gait patterns from routine activitiesJournal of Biomechanics, 2001
- The fate of massive allografts in total hip acetabular revision surgeryThe Journal of Arthroplasty, 1992