Everton Rodrigues Da Silva
Research Subjects
Everton Rodrigues Da Silva has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Claudia Lucia de Pinho Mauricio
Instituto de Radioproteção e Dosimetria - IRD/CNEN
2 shared publications Ana Laura Garcia
Laboratorio Personal de Dosimetría Externa (LPDE/MIEM) , Uruguay
1 shared publicationAndrea Castillo
Laboratorio de Física de Radiaciones y Metrología (LAF-RAM/UNAN-Managua) , Nicaragua
1 shared publicationBruno M Freitas
Programa de Engenharia Nuclear/COPPE, Universidade Federal do Rio de Janeiro, 2030 Horácio Macedo Avenue, Rio de Janeiro, Brazil
1 shared publicationByron Bastidas
Subsecretaria de Control y Aplicaciones Nucleares (SCAN) , Ecuador
1 shared publication- Charles N. Grant
University of the West Indies International Centre for Environmental and Nuclear Sciences Jamaica
1 shared publication
Latest Publications
- 11 October 2023
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 199 (15-16) , 1739-1742
Results and analysis of an intercomparisons study for individual monitoring services of Latin American and Caribbean regions
The aim of this paper is to present the results obtained by the Latin-American and Caribbean personal dosimetry services that participated, with the support of IAEA, in the 2020-Eurados whole-body dosemeter intercomparison for photon radiation. All participant services in this study use thermoluminescent dosimetry (TLD) systems except one that uses optically stimulated luminescence (OSL) dosemeters. Data analysis shows that 93.4% of the results are within the acceptance range, according to International ISO Standard ISO 14146: 2018. The evaluation of the trumpet curves shows that only three laboratories presented a few dosemeters results outside the limits of acceptability. Participation in this Eurados intercomparison exercise gave the Latin American and Caribbean laboratories the opportunity to show compliance with their own quality management system, to compare results with other participants and to develop plans for improving their dosimetry systems. It also gave the assurance that occupational doses are being measured properly and following the international standards in the regions.
- 11 October 2023
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 199 (15-16) , 1739-1742
Results and analysis of an intercomparisons study for individual monitoring services of Latin American and Caribbean regions
The aim of this paper is to present the results obtained by the Latin-American and Caribbean personal dosimetry services that participated, with the support of IAEA, in the 2020-Eurados whole-body dosemeter intercomparison for photon radiation. All participant services in this study use thermoluminescent dosimetry (TLD) systems except one that uses optically stimulated luminescence (OSL) dosemeters. Data analysis shows that 93.4% of the results are within the acceptance range, according to International ISO Standard ISO 14146: 2018. The evaluation of the trumpet curves shows that only three laboratories presented a few dosemeters results outside the limits of acceptability. Participation in this Eurados intercomparison exercise gave the Latin American and Caribbean laboratories the opportunity to show compliance with their own quality management system, to compare results with other participants and to develop plans for improving their dosimetry systems. It also gave the assurance that occupational doses are being measured properly and following the international standards in the regions.
- Open Access
- 19 July 2018
- Published by Sociedade Brasileira de Proteção Radiológica - SBPR in Brazilian Journal of Radiation Sciences
- Vol. 6 (2A (Suppl.)
Teste de tipo de um sistema de dosimetria TL para monitoração individual de fótons em Hp(10)
Although regulated, the use of HP(10) to estimate the effective dose of photons has not yet been implemented in Brazil. The operational quantity used in the country, temporarily, is the photon dose equivalent (Hx). For the external monitoring of individuals exposed to photons, the IRD uses an automatic TL dosimetry system with individual MTS-N monitors from the RADOS manufacturer, which contains LiF: Mg, Ti TLDs. The objective of this work was to characterize this system for the evaluation of the operational quantity HP(10). The measuring range is 0.2 mSv to 2 Sv, for photon energies from 20 keV to 1250 keV. The type test was done through performance tests for the following characteristics: homogeneity of the monitors, system reproducibility, linearity, temperature and humidity effect, energy and angular dependence, and fading. The acceptance requirements were taken from IEC 62387 standard and IRD-RT 002.01/95 technical regulation. The results show that all requirements have been met, except for the N-25 quality, at the angle of 60°.
- 19 July 2018
- Published by Sociedade Brasileira de Proteção Radiológica - SBPR in Brazilian Journal of Radiation Sciences
- Vol. 6 (2A (Suppl.)
Open AccessTeste de tipo de um sistema de dosimetria TL para monitoração individual de fótons em Hp(10)
Although regulated, the use of HP(10) to estimate the effective dose of photons has not yet been implemented in Brazil. The operational quantity used in the country, temporarily, is the photon dose equivalent (Hx). For the external monitoring of individuals exposed to photons, the IRD uses an automatic TL dosimetry system with individual MTS-N monitors from the RADOS manufacturer, which contains LiF: Mg, Ti TLDs. The objective of this work was to characterize this system for the evaluation of the operational quantity HP(10). The measuring range is 0.2 mSv to 2 Sv, for photon energies from 20 keV to 1250 keV. The type test was done through performance tests for the following characteristics: homogeneity of the monitors, system reproducibility, linearity, temperature and humidity effect, energy and angular dependence, and fading. The acceptance requirements were taken from IEC 62387 standard and IRD-RT 002.01/95 technical regulation. The results show that all requirements have been met, except for the N-25 quality, at the angle of 60°.
- 13 April 2018
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 180 (1-4) , 89-93
ALGORITHM BASED ON ARTIFICIAL BEE COLONY FOR UNFOLDING OF NEUTRON SPECTRA OBTAINED WITH BONNER SPHERES
Occupational neutron fields usually have energies from the thermal range to some MeV and the characterization of the spectra is essential for estimation of the radioprotection quantities. Thus, the spectrum must be unfolded based on a limited number of measurements. This study implemented an algorithm based on the bee colonies behavior, named Artificial Bee Colony (ABC), where the intelligent behavior of the bees in search of food is reproduced to perform the unfolding of neutron spectra. The experimental measurements used Bonner spheres and 6LiI (Eu) detector, with irradiations using a thermal neutron flux and three reference fields: 241Am–Be, 252Cf and 252Cf (D2O). The ABC obtained good estimation of the expected spectrum even without previous information and its results were closer to expected spectra than those obtained by the SPUNIT algorithm.
- 13 April 2018
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 180 (1-4) , 89-93
ALGORITHM BASED ON ARTIFICIAL BEE COLONY FOR UNFOLDING OF NEUTRON SPECTRA OBTAINED WITH BONNER SPHERES
Occupational neutron fields usually have energies from the thermal range to some MeV and the characterization of the spectra is essential for estimation of the radioprotection quantities. Thus, the spectrum must be unfolded based on a limited number of measurements. This study implemented an algorithm based on the bee colonies behavior, named Artificial Bee Colony (ABC), where the intelligent behavior of the bees in search of food is reproduced to perform the unfolding of neutron spectra. The experimental measurements used Bonner spheres and 6LiI (Eu) detector, with irradiations using a thermal neutron flux and three reference fields: 241Am–Be, 252Cf and 252Cf (D2O). The ABC obtained good estimation of the expected spectrum even without previous information and its results were closer to expected spectra than those obtained by the SPUNIT algorithm.