Eduardo Rodriguez Montero
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Eduardo Rodriguez Montero has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Markus Vogelsberger
Rolling Stock PlatformComponents DivisionDRIVES, ALSTOM Transport Austria GmbH, Vienna, Austria
4 shared publications - Thomas M. Wolbank
Vienna University of Technology,Department of Energy Systems and Electrical Drives,Vienna,Austria
4 shared publications Felix Baumgartner
Institute of Energy Systems and Electrical Drives, Technical University of Vienna, Vienna, Austria
1 shared publicationMarkus Vogelsberger
Rolling Stock Platform/Components Division , ALSTOM Transport Austria GmbH, Vienna , Austria
1 shared publicationThomas Wolbank
Institute of Energy Systems and Electrical Drives , Technische Universität Wien , Vienna , Austria
1 shared publicationWolfram Teppan
LEM Advisory Services SA,Fribourg,Switzerland
1 shared publication
Latest Publications
- Open Access
- 15 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 11 (2) , 6119-6131
Low-Speed Rotor Angle Estimation of Multi-Salient Railway Propulsion Motors at Any Torque
Providing reliable and efficient electric drives for rolling stocks are two key objectives within the railway industry. Accordingly, industries are putting relentless efforts in increasing drives’ reliability and reducing their cost and volume. In this sense, encoderless motor drives can notably contribute to these targets. While high-speed encoderless operation can be successfully ensured by fundamental-wave models, stable control at speeds around zero speed is still challenging and, as yet, not standard. At near-zero speeds, the use of spatial saliencies of induction motors (IMs) opens up new horizons of encoderless control methods since saliencies provide information on the rotor angle or flux. In particular, the standard design of railway propulsion IMs occasionally involves the creation of three dominant spatial saliencies: saturation, slotting and intermodulation. This intermodulation saliency has been previously compensated in available literature. In this work, the intermodulation saliency is used to obtain a rotor position, harnessing its distinct characteristics of high signal strength and high estimation accuracy even at the challenging point of overload. Two standard railway traction motors with different ratings serve to experimentally validate the suitability of the intermodulation saliency for high-precision rotor position extraction at near-zero speeds under a wide torque range even beyond rated load.
- 15 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 11 (2) , 6119-6131
Open AccessLow-Speed Rotor Angle Estimation of Multi-Salient Railway Propulsion Motors at Any Torque
Providing reliable and efficient electric drives for rolling stocks are two key objectives within the railway industry. Accordingly, industries are putting relentless efforts in increasing drives’ reliability and reducing their cost and volume. In this sense, encoderless motor drives can notably contribute to these targets. While high-speed encoderless operation can be successfully ensured by fundamental-wave models, stable control at speeds around zero speed is still challenging and, as yet, not standard. At near-zero speeds, the use of spatial saliencies of induction motors (IMs) opens up new horizons of encoderless control methods since saliencies provide information on the rotor angle or flux. In particular, the standard design of railway propulsion IMs occasionally involves the creation of three dominant spatial saliencies: saturation, slotting and intermodulation. This intermodulation saliency has been previously compensated in available literature. In this work, the intermodulation saliency is used to obtain a rotor position, harnessing its distinct characteristics of high signal strength and high estimation accuracy even at the challenging point of overload. Two standard railway traction motors with different ratings serve to experimentally validate the suitability of the intermodulation saliency for high-precision rotor position extraction at near-zero speeds under a wide torque range even beyond rated load.
- Open Access
- 2 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 70 (12) , 12093-12101
Sensorless Saliency-Based Control of Dual Induction Machines Under Dynamic Load Imbalances Using Three Current Sensors
To perform vector control of single-inverter dual induction motors, drives are standardly equipped with current and position sensors. In medium-power railway applications, a shaft encoder is usually mounted on each motor, and the inverter output current is measured using two current sensors. Yet, this configuration features some disadvantages. First, torque-sharing cannot be computed because stator current of each motor is unknown. Similarly, saliency extraction of each motor is not achievable since individual current drawn by each motor is not measured. An option that achieves torque-sharing calculation is to attach two current sensors to each motor, provided that both rotor positions are known. However, industrial inverter/control platforms considered offer a maximum of three input channels for current sensors. Besides, some industry fields tend towards encoderless speed control. Therefore, this article proposes to use three current sensors in total and no shaft encoders. Thanks to a special current sensor arrangement and a voltage step excitation method, saliency-based encoderless control is achieved. In addition, a method is presented to estimate torque-sharing. Experimental measurements, taken on a dual induction motor test bench, will show the capability of the proposed methodology to identify individual loading as well as excellent encoderless control performance.
- 2 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 70 (12) , 12093-12101
Open AccessSensorless Saliency-Based Control of Dual Induction Machines Under Dynamic Load Imbalances Using Three Current Sensors
To perform vector control of single-inverter dual induction motors, drives are standardly equipped with current and position sensors. In medium-power railway applications, a shaft encoder is usually mounted on each motor, and the inverter output current is measured using two current sensors. Yet, this configuration features some disadvantages. First, torque-sharing cannot be computed because stator current of each motor is unknown. Similarly, saliency extraction of each motor is not achievable since individual current drawn by each motor is not measured. An option that achieves torque-sharing calculation is to attach two current sensors to each motor, provided that both rotor positions are known. However, industrial inverter/control platforms considered offer a maximum of three input channels for current sensors. Besides, some industry fields tend towards encoderless speed control. Therefore, this article proposes to use three current sensors in total and no shaft encoders. Thanks to a special current sensor arrangement and a voltage step excitation method, saliency-based encoderless control is achieved. In addition, a method is presented to estimate torque-sharing. Experimental measurements, taken on a dual induction motor test bench, will show the capability of the proposed methodology to identify individual loading as well as excellent encoderless control performance.
- Open Access
- 13 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 58 (2) , 2097-2106
Induction Machine Sensorless Control Based on Saliency Extraction That Uses One Single SVPWM Active State
Some induction motors present saliencies that periodically modify the air-gap flux following a sinusoidal shape. Consequently, these modulations are reflected in the transient leakage inductance. Therefore, transient leakage inductance can be expressed as a constant term or offset, which comes from the symmetrical machine, plus all motor saliency sinusoids, modulated by the mentioned saliencies. Since saliencies are linked to the rotor position or flux, calculation of transient leakage inductance enables encoderless vector control. A way to calculate transient leakage inductance is to excite the machine with voltage steps and estimate the resulting phase current slopes since they are inversely proportional to phase transient inductance. For creating a vector, only the three current slopes resulting from a single active state are sufficient. The vector sum of the three current slopes leads to the so-called saliency-offset vector, which is a vector composed of an offset, which is created due to the contribution of the transient inductance offset, plus several saliency phasors, superposed to the offset. To access saliencies, it is critical to accurately identify the offset of the saliency-offset vector, especially in induction motors since offset is much bigger than saliencies. This article presents an advanced signal processing scheme that identifies the offset in the saliency-offset vector, assuming offset amplitude differsdepending on the voltage step applied. Using a feedforward scheme, the offset is eliminated, leading to a saliency vector where rotor slotting can be extracted from. A novel excitation is proposed to reduce additional current distortions coming from the one-active excitation.
- 13 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 58 (2) , 2097-2106
Open AccessInduction Machine Sensorless Control Based on Saliency Extraction That Uses One Single SVPWM Active State
Some induction motors present saliencies that periodically modify the air-gap flux following a sinusoidal shape. Consequently, these modulations are reflected in the transient leakage inductance. Therefore, transient leakage inductance can be expressed as a constant term or offset, which comes from the symmetrical machine, plus all motor saliency sinusoids, modulated by the mentioned saliencies. Since saliencies are linked to the rotor position or flux, calculation of transient leakage inductance enables encoderless vector control. A way to calculate transient leakage inductance is to excite the machine with voltage steps and estimate the resulting phase current slopes since they are inversely proportional to phase transient inductance. For creating a vector, only the three current slopes resulting from a single active state are sufficient. The vector sum of the three current slopes leads to the so-called saliency-offset vector, which is a vector composed of an offset, which is created due to the contribution of the transient inductance offset, plus several saliency phasors, superposed to the offset. To access saliencies, it is critical to accurately identify the offset of the saliency-offset vector, especially in induction motors since offset is much bigger than saliencies. This article presents an advanced signal processing scheme that identifies the offset in the saliency-offset vector, assuming offset amplitude differsdepending on the voltage step applied. Using a feedforward scheme, the offset is eliminated, leading to a saliency vector where rotor slotting can be extracted from. A novel excitation is proposed to reduce additional current distortions coming from the one-active excitation.
- 17 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Sensorless Saliency Extraction using Quadratic-Regression-based Current Derivative Estimation
Stable field oriented control of induction machines in the proximity of zero electrical frequency relies on the extraction of machine saliencies for rotor flux/positon acquisition. To obtain such saliency information, voltage step excitation methods can be used. They excite the machine with a voltage step caused by the inverter and calculate the resulting phase current derivative, which contains several terms including the superposition of saliency components. Multiple strategies have been used to calculate the current derivative, such as FFT, neural networks, or linear regression. However, they do not take into account the influence of a curvature of the current response. This paper proposes using a least-square quadratic regression to calculate machine saliency information. In this sense, the linear response of the phase current can be accurately isolated from the inherent curvature. It will be proved by experimental measurements that the different saliencies' components are observed in both the second order and also first order term of the quadratic regression function. A performance comparison between linear regression and quadratic regression will be shown in terms of saliency acquisition.
- 17 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Sensorless Saliency Extraction using Quadratic-Regression-based Current Derivative Estimation
Stable field oriented control of induction machines in the proximity of zero electrical frequency relies on the extraction of machine saliencies for rotor flux/positon acquisition. To obtain such saliency information, voltage step excitation methods can be used. They excite the machine with a voltage step caused by the inverter and calculate the resulting phase current derivative, which contains several terms including the superposition of saliency components. Multiple strategies have been used to calculate the current derivative, such as FFT, neural networks, or linear regression. However, they do not take into account the influence of a curvature of the current response. This paper proposes using a least-square quadratic regression to calculate machine saliency information. In this sense, the linear response of the phase current can be accurately isolated from the inherent curvature. It will be proved by experimental measurements that the different saliencies' components are observed in both the second order and also first order term of the quadratic regression function. A performance comparison between linear regression and quadratic regression will be shown in terms of saliency acquisition.
- Open Access
- 1 January 2021
- Published by Walter de Gruyter GmbH in Power Electronics and Drives
- Vol. 6 (1) , 301-313
Initial Rotor Position Detection of Induction Machines Using Feedforward Sensorless Saliency Separation
The use of induction machine spatial saliencies for sensorless vector control in the proximity of zero electrical frequency has been extensively researched over the last few decades. A robust technique to extract machine saliencies is called voltage step excitation, and it computes a saliency phasor out of phase current derivatives resulting from specific voltage steps generated by the inverter switching. Within the saliency phasor, all machine saliencies appear superposed. For some machine constructions, multiple saliencies are present, containing information about the spatial, magnetic and geometric state of the machine. Due to its direct relation with the rotor angle and its high accuracy, rotor slotting saliency is often chosen as the sensorless control signal. In order to exclusively access rotor slotting, saliency separation needs to be carried out, with the goal of eliminating all non-control saliencies from the saliency phasor. In this research, feedforward harmonic compensation based on look-up tables (LUTs) is chosen. The idea is to estimate each saliency in relation to amplitude and phase shift once, store such information in a torque-dependent LUT and use it for feedforward compensation. Yet, several saliencies are linked to the rotor position and, thus, the stored phase shift in the LUT is fixed to a defined rotor position at which the saliency estimation was performed. For the feedforward compensation to work during each sensorless start-up, an initial rotor slot detection must be carried out. This paper presents a technique to estimate initial rotor angle based only on the inherent characteristics of the induction machine multi-saliencies and an iterative feedforward compensation process that requires no extra resources and only a few PWM (Pulse Width Modulation) periods to achieve initial slot rotor angle. Experimental results measured at two different test benches prove the high accuracy of the method.
- 1 January 2021
- Published by Walter de Gruyter GmbH in Power Electronics and Drives
- Vol. 6 (1) , 301-313
Open AccessInitial Rotor Position Detection of Induction Machines Using Feedforward Sensorless Saliency Separation
The use of induction machine spatial saliencies for sensorless vector control in the proximity of zero electrical frequency has been extensively researched over the last few decades. A robust technique to extract machine saliencies is called voltage step excitation, and it computes a saliency phasor out of phase current derivatives resulting from specific voltage steps generated by the inverter switching. Within the saliency phasor, all machine saliencies appear superposed. For some machine constructions, multiple saliencies are present, containing information about the spatial, magnetic and geometric state of the machine. Due to its direct relation with the rotor angle and its high accuracy, rotor slotting saliency is often chosen as the sensorless control signal. In order to exclusively access rotor slotting, saliency separation needs to be carried out, with the goal of eliminating all non-control saliencies from the saliency phasor. In this research, feedforward harmonic compensation based on look-up tables (LUTs) is chosen. The idea is to estimate each saliency in relation to amplitude and phase shift once, store such information in a torque-dependent LUT and use it for feedforward compensation. Yet, several saliencies are linked to the rotor position and, thus, the stored phase shift in the LUT is fixed to a defined rotor position at which the saliency estimation was performed. For the feedforward compensation to work during each sensorless start-up, an initial rotor slot detection must be carried out. This paper presents a technique to estimate initial rotor angle based only on the inherent characteristics of the induction machine multi-saliencies and an iterative feedforward compensation process that requires no extra resources and only a few PWM (Pulse Width Modulation) periods to achieve initial slot rotor angle. Experimental results measured at two different test benches prove the high accuracy of the method.