Zeqian Wu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Zeqian Wu has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Jinxing Cheng
Tsinghua University
3 shared publications - Qingbo Wang
Beijing High-Tech Institute, Beijing 100094, China
3 shared publications - Ai Yu
Beijing New-High Technology Academy, Beijing 100094, China
2 shared publications - Fang Liu
Beijing Key Laboratory of Passive Safety Technology for Nuclear Energy, School of Nuclear Science and Engineering, North China Electric Power University, Beijing, 102206, China
2 shared publications - Weiwei Wen
Beijing New-High Technology Academy, Beijing 100094, China
2 shared publications - Youpeng Wu
Beijing New-High Technology Academy, Beijing 100094, China
2 shared publications
Latest Publications
- Top Cited PapersOpen Access
Research on the Technological Progress of CZT Array Detectors
CdZnTe (CZT) is a new type of compound semiconductor that has emerged in recent years. Compared to other semiconductor materials, it possesses an ideal bandgap, high density, and high electron mobility, rendering it an excellent room-temperature composite semiconductor material for X-ray and γ-ray detectors. Due to the exceptional performance of CZT material, detectors manufactured using it exhibit high energy resolution, spatial resolution, and detection efficiency. They also have the advantage of operating at room temperature. CZT array detectors, furthermore, demonstrate outstanding spatial detection and three-dimensional imaging capabilities. Researchers worldwide have conducted extensive studies on this subject. This paper, building upon this foundation, provides a comprehensive analysis of CZT crystals and CZT array detectors and summarizes existing research to offer valuable insights for envisioning new detector methodologies.
Top Cited PapersOpen AccessResearch on the Technological Progress of CZT Array Detectors
CdZnTe (CZT) is a new type of compound semiconductor that has emerged in recent years. Compared to other semiconductor materials, it possesses an ideal bandgap, high density, and high electron mobility, rendering it an excellent room-temperature composite semiconductor material for X-ray and γ-ray detectors. Due to the exceptional performance of CZT material, detectors manufactured using it exhibit high energy resolution, spatial resolution, and detection efficiency. They also have the advantage of operating at room temperature. CZT array detectors, furthermore, demonstrate outstanding spatial detection and three-dimensional imaging capabilities. Researchers worldwide have conducted extensive studies on this subject. This paper, building upon this foundation, provides a comprehensive analysis of CZT crystals and CZT array detectors and summarizes existing research to offer valuable insights for envisioning new detector methodologies.
- Open Access
- 29 December 2022
- Published by MDPI AG in Preprints.org
Development of Adjustable High-Voltage Power Supply for Air Kerma Meter
The general circuit topology and principles of low-noise high-voltage power supply are investigated to meet the requirements of the high-voltage bias application in air kerma meters. Two topologies, flyback converter and Royer converter are simulated using SPICE simulation program. The simulation results indicate that the circuit structure of the Royer converter is more complex, but it obtains lower output high voltage noise. While we develop an adjustable high-voltage power supply according to the circuit structure of the Royer converter, and tested it to ensure the design requirements for continuously adjustable output high-voltage linearity. The test results show that the linear adjustment rate is not more than ±0.0025%, the load regulation rate is less than ±0.1%, and the output ripple noise voltage percentage is less than 0.01%. These tested performance make it more suitable for accurate nuclear measurements.
- 29 December 2022
- Published by MDPI AG in Preprints.org
Open AccessDevelopment of Adjustable High-Voltage Power Supply for Air Kerma Meter
The general circuit topology and principles of low-noise high-voltage power supply are investigated to meet the requirements of the high-voltage bias application in air kerma meters. Two topologies, flyback converter and Royer converter are simulated using SPICE simulation program. The simulation results indicate that the circuit structure of the Royer converter is more complex, but it obtains lower output high voltage noise. While we develop an adjustable high-voltage power supply according to the circuit structure of the Royer converter, and tested it to ensure the design requirements for continuously adjustable output high-voltage linearity. The test results show that the linear adjustment rate is not more than ±0.0025%, the load regulation rate is less than ±0.1%, and the output ripple noise voltage percentage is less than 0.01%. These tested performance make it more suitable for accurate nuclear measurements.
- Open Access
Application and Development of Noncontact Detection Method of α-Particles Based on Radioluminescence
The detection of α particles is of great significance in military and civil nuclear facility management. At present, the contact method is mainly used to detect α particles, but its shortcomings limit the broad application of this method. In recent years, preliminary research on noncontact α-particle detection methods has been carried out. In this paper, the theory of noncontact α-particles detection methods is introduced and studied. We also review the direct detection and imaging methods of α particles based on the different wavelengths of fluorescence photons, and analyze the application and development of this method, providing an important reference for researchers to carry out related work.
Open AccessApplication and Development of Noncontact Detection Method of α-Particles Based on Radioluminescence
The detection of α particles is of great significance in military and civil nuclear facility management. At present, the contact method is mainly used to detect α particles, but its shortcomings limit the broad application of this method. In recent years, preliminary research on noncontact α-particle detection methods has been carried out. In this paper, the theory of noncontact α-particles detection methods is introduced and studied. We also review the direct detection and imaging methods of α particles based on the different wavelengths of fluorescence photons, and analyze the application and development of this method, providing an important reference for researchers to carry out related work.