MMMarina V. Makarochkina

Marina V. Makarochkina

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Marina V. Makarochkina has a total of 32 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Robot-assisted laparoscopic adrenalectomy – first experience of use in children

    by Yury A. Kozlov, A. P. Rozhansky, E. V. Sapukhin, A. A. Marchuk, Yu. P. Semshchikova, M. V. Makarochkina

    The aim of this publication is to demonstrate the reproducibility and safety of the robotic-assisted approach in children with adrenal tumors. Clinical case. A 15-year-old adolescent with an adrenal tumor was diagnosed incidentally during a routine visit to the emergency room due to the sudden onset of a right-sided hydrocele. After performing an ultrasound examination, a 43 × 41 mm tumor was detected in the projection of the right adrenal gland. Subsequent computed tomography confirmed the organ affiliation of the tumor associated with the right adrenal gland. Robot-assisted laparoscopic adrenalectomy was performed using the Versius surgical robot. Initially, the hepatic flexure of the colon was mobilized, exposing the inferior vena cava, spread out on the surface of the tumor. The adrenal vein was isolated, ligated using Hem-o-lok® clips (Teleflex, USA) and transected. Then the adrenal gland together with the tumor was carefully mobilized from the medial side by coagulation of adhesions connecting it to the inferior vena cava. Small adrenal vessels were coagulated with bi- and monopolar robotic instruments (Maryland clamp and hook) from the cranial and lateral surfaces, which allowed complete tumor resection. The adrenal gland was removed externally using a tissue removal bag. Tumor resection was performed completely robotically without conversion to laparoscopy or open surgery. Tumor resection was macroscopically complete. The duration of the operation was 180 min, the net console time was 165 min. We did not observe any intraoperative complications, such as bleeding, damage to adjacent organs, injuries associated with the impact of manipulators on the anterior abdominal wall. The child was discharged from the hospital on the 5th postoperative day. The postoperative period was uneventful. The removed pathological tissue sample, upon histological examination, corresponded to a ganglioneuroma formed from mature ganglion cells and sympathetic nerve ganglia. Conclusion. The presented case demonstrates that adrenalectomy can be performed using robotics due to its advantages, which include improved visualization and increased maneuverability when working with robotic instruments.

  • Open Access

    The use of indocyanine green navigation in the treatment of a choledochal cyst in a child

    by Yury A. Kozlov, Alexander P. Rozhanski, Marina V. Makarochkina, Eduard V. Sapukhin, Alexey S. Strashinsky, Anna O. Ryakhina, Yulia P. Semshchikova, Страшинский Алексей Сергеевич, Съемщикова Юлия Павловна

    In pediatric surgery, near-infrared fluorescence imaging using indocyanine green has become widespread. This report presents a new approach for intraoperative identification of extrahepatic bile duct anatomy during laparoscopic choledochal cyst resection and hepatoduodenostomy formation in a pediatric patient. A 10-month-old girl presented with episodes of restlessness accompanied by vomiting. On prenatal ultrasound, a cystic lesion was detected in the hepatic portal region, and its presence was subsequently confirmed on postnatal imaging. Contrast-enhanced computed tomography and magnetic resonance cholangiopancreatography revealed a Todani type Ib choledochal cyst measuring 2.2×1.6×1.6 cm. For intraoperative fluorescence navigation, indocyanine green (0.25 mg/kg) was administered intravenously 12 hours before surgery. The procedure consisted of laparoscopic cyst resection followed by hepatoduodenostomy creation. Operative time was 120 minutes. Fluorescence imaging clearly delineated the distal margin of the cyst within the pancreatic parenchyma and its proximal extent at the level of the common hepatic duct. Enteral feeding was initiated on postoperative day 2. No intraoperative complications occurred. Postoperatively, the patient showed improvement, with decreased bilirubin levels and liver enzyme activity. No evidence of anastomotic leakage was found during early follow-up. Hospital stay was 7 days. At 6 months of follow-up, the patient had no clinical or laboratory signs of obstructive jaundice or cholangitis. In conclusion, fluorescence imaging with indocyanine green is a safe and highly informative method for intraoperative identification and resection of a choledochal cyst.

  • Open Access

    Robot-assisted resection of a common bile duct cyst with hepaticoduodenostomy in a child: a case report

    by Yury A. Kozlov, Alexander P. Rozhanski, Eduard V. Sapukhin, Alexey S. Strashinsky, Andrey A. Marchuk, Anna O. Ryakhina, Yulia P. Semshchikova, Marina V. Makarochkina, Страшинский Алексей Сергеевич, Съемщикова Юлия Павловна

    A choledochal cyst is a rare congenital anomaly of the bile ducts. In recent years, surgical approaches to its treatment have evolved from laparotomy to laparoscopy and robot-assisted surgery. This article analyzes the clinical course of a 4-year-old girl diagnosed with a choledochal cyst. The patient’s main complaints were recurrent upper abdominal pain accompanied by a single episode of jaundice at age 3 years. At the time of admission, the patient’s symptom duration was 1.5 years. Preoperative evaluation included liver function tests, coagulation profile, ultrasound, and magnetic resonance cholangiopancreatography, which revealed a type I choledochal cyst measuring 27.3 mm in diameter. Robot-assisted choledochal cyst resection followed these principles: cyst dissection with clipping of the distal common hepatic duct, proximal cyst dissection with transverse transection at the level of the non-dilated common hepatic duct, and hepaticoduodenostomy creation. Operative time was 240 minutes: docking time, 20 minutes; console time, 220 minutes. Enteral nutrition was initiated on postoperative day 3, and full enteral nutrition was achieved on postoperative day 5. The child demonstrated successful postoperative recovery, with early transition to a full enteral diet and discharge for outpatient follow-up on postoperative day 7. At follow-up, the child had normal weight and height parameters, no pain, and normal bile duct diameter on liver ultrasound. Compared with laparoscopy, robot-assisted surgery for congenital choledochal cysts in children offers advantages including enhanced visualization and exceptional robotic instrument maneuverability, resulting in less tissue damage, greater precision in hepaticoduodenostomy creation, and faster patient recovery. This case demonstrates the potential of robot-assisted surgery for treating children with hepatobiliary pathology.

  • Robot-assisted heminefrectomy in a patient with duplex kidney: а case report

    by Yury A. Kozlov, Alexander P. Rozhanski, Eduard V. Sapukhin, Alexey S. Strashinsky, Marina V. Makarochkina, Andrey A. Marchuk, Страшинский Алексей Сергеевич

    Robot-assisted surgery is a relatively new technology that enables a wide range of urological procedures to be performed using a minimally invasive approach. Various studies have shown that this technology is feasible and safe in most pediatric patients. The authors of this study conducted a retrospective review of the medical history of a child with a doubling of the upper urinary tract, accompanied by obstructive damage to the upper segment of the ureter with loss of its excretory function. The data collection included the patient's medical history and demographic data, diagnosis, type of surgery, total time of surgery, outcome of surgery, and the anatomical and functional state of the kidney during follow-up. A 12-year-old girl presented to the surgical department with complaints of recurrent urinary tract infections and right flank pain for the last year of her life. Robot-assisted laparoscopic heminephrectomy (RALHN) was performed using the Versius surgical robot. The upper segment ureter was transected at the lower pole of the kidney. The afunctional portion of the kidney was dissected from the normal kidney using a bipolar coagulation clamp. The lower segment incision edges were left open. The distal ureter was then isolated and sealed with a clip. The robot-assisted laparoscopic heminephrectomy procedure was successfully performed without intraoperative complications. The surgery duration was 225 minutes, including 20 minutes for robotic insertion. The total console time was 205 minutes. The drainage tube was removed after a follow-up ultrasound examination on the second day. The stent remained in the lower segment ureter until its removal six weeks after surgery. A repeat ultrasound examination performed postoperatively demonstrated no dilation of the lower segment pelvis or fluid collections in the area of the right kidney. Blood flow to the residual segment of the right kidney was not impaired. The advantages of the robotic approach to treating upper urinary tract duplication, including improved instrument maneuverability and 3D visualization, make it a safe and effective alternative to open or laparoscopic surgery in children.

  • Robot-assisted laparoscopic extravesical ureteral reimplantation in a child with primary obstructive megaureter: а case report

    by Yury A. Kozlov, A. P. Rozhansky, Eduard V. Sapukhin, Alexey S. Strashinsky, Marina V. Makarochkina, Andrey A. Marchuk, Страшинский Алексей Сергеевич

    The primary obstructive megaureter accounts for approximately 10% of all uropathies. The overall primary obstructive megaureter incidence is 1:2000 newborns. About 80% of perinatally diagnosed cases of primary obstructive megaureter resolve spontaneously during the first years of a child's life, and therefore most cases of the disease are subject to conservative treatment. Increasing obstruction and decreased renal function are indications for surgical treatment. The present article describes a case of 8 years old male patient who underwent surgery for the primary obstructive megaureter on the left using a robot-assisted technique. The preoperative left ureteral diameter was 13.5 mm. A radionuclide renal scan revealed an obstructive urinary excretion curve in the left kidney and decreased differentiated renal function on the left side up to 30%. The extravesical ureteral reimplantation technique previously proposed by M. Lopez was used. Surgery was uneventful. A drainage tube was removed on the second postoperative day. A ureteral stent was removed one month after the surgery. After the surgery, the child was monitored closely for 6 months. No serious complications, such as symptom recurrence or development of vesicoureteral reflux, were detected. The distal ureteral diameter decreased to 8 mm. Renal scintigraphy showed a non-obstructive pattern and improved differentiated renal function by 40%. In their work, the authors evaluated clinical efficacy of robotic-assisted laparoscopic reimplantation of the ureter in the primary obstructive megaureter in children: surgery is a safe and effective curative option for congenital structural disorders of the distal ureter. However, larger randomized prospective studies and long-term follow-up are needed to confirm the effectiveness of this technique.

  • History of robotics in surgery

    by Yury A. Kozlov, Eduard V. Sapukhin, Marina V. Makarochkina, Alexey S. Strashinsky, Andrey A. Marchuk, Alexander P. Rozhanski, Страшинский Алексей Сергеевич

    The pioneering projects aimed at integrating automated devices into surgical practice date back to the late 1960s. However, the transition from concept to a mass-produced product took nearly three decades. Today, the da Vinci platform (Intuitive Surgical Inc., USA) dominates the global medical community as a system for performing minimally invasive procedures. Importantly, its success was preceded by the development of earlier prototypes, including ZEUS, AESOP, ROBODOC, and the Green Telepresence System. Notably, the original purpose of these technological innovations was not commercial medicine but rather the provision of surgical care under field conditions, including battlefield settings. The research groundwork established with the participation of SRI International and the Advanced Research Projects Agency was later transferred to the private sector. The subsequent consolidation of multiple market players ultimately led to the formation of Intuitive Surgical Inc. This article reconstructs the complete chronology of the development of surgical robots. The methodology includes a meticulous analysis of archival data and scientific publications, as well as direct interviews with leading experts in the field of minimally invasive techniques. Such work is essential, as robotic interventions are currently evolving from an experimental approach into a widely accepted clinical standard, which necessitates a comprehensive understanding of the path already taken.

  • Robot-assisted laparoscopic pyeloplasty for horseshoe kidney in a child: a case report

    by Yury A. Kozlov, Alexander P. Rozhanski, Simon S. Poloyan, Eduard V. Sapukhin, Alexey S. Strashinsky, Marina V. Makarochkina, Andrey A. Marchuk, Sergey A. Muravev, Страшинский Алексей Сергеевич

    The laparoscopic approach can be technically challenging in patients with a horseshoe kidney due to the specific anatomy, including caudal kidney position and rotation, aberrant vessels, and high ureteral origin. The use of robotic systems has facilitated the performance of this procedure. We conducted a retrospective review of the medical records of a 1-year-old child with ureteropelvic junction obstruction associated with a horseshoe kidney. Contrast-enhanced computed tomography was the primary diagnostic modality for identifying the cause of hydronephrosis and allowed accurate determination of the true source of obstruction, namely a high origin of the ureter from the renal pelvis. The patient underwent robot-assisted Anderson–Hynes pyeloplasty. The key differences from surgery in anatomically normal kidneys included caudal placement of robotic ports and meticulous assessment of the renal vascular anatomy. The procedure was successfully completed with robotic assistance without conversion to laparoscopy or open surgery. No intraoperative complications related to bleeding or injury to adjacent organs were observed. The total operative time, including robotic docking, was 165 minutes: docking time was 15 minutes, and total console time was 150 minutes. The hospital stay lasted 5 days. The pyelostomy tube was removed on postoperative day 7 in an outpatient setting. The anteroposterior diameter of the renal pelvis was measured preoperatively and 6 months after surgery. The renal pelvis diameter decreased from 37 mm to 8 mm. Radionuclide renal imaging showed no residual obstruction on diuretic renography. The results of this case confirm that robot-assisted laparoscopic pyeloplasty for horseshoe kidney is safe, feasible, and associated with favorable outcomes when performed by experienced surgeons.

  • Using robot-assisted surgery in gynecological diseases in children: a series of clinical cases

    by Yuri A. Kozlov, Alexander P. Rozhansky, Eduard V. Sapukhin, Alexey S. Strashinsky, A. A. Marchuk, Anna O. Ryakhina, Marina V. Makarochkina, Страшинский Алексей Сергеевич

    BACKGROUND: In the recent years, robot-assisted surgery has become widespread and has demonstrated the ability to overcome technical limitations of traditional laparoscopy and open surgery. Advantages of robotic surgery are: three-dimensional imaging and multiple magnification, increased maneuverability due to seven degrees of freedom of robotic instruments, tremor filtering, and improved ergonomics. AIM: evaluate the safety and effectiveness of robot-assisted surgeries performed in pediatric patients with gynecological pathology. METHODS: The present trial is a retrospective analysis of data from patients with gynecological diseases operated on in the Irkutsk State Regional Children’s Clinical Hospital. Versius robotic system (Cambridge Medical Robotics, Great Britain) was used. RESULTS: Robot-assisted surgeries were performed in 5 patients who had the following diagnoses before surgery: ovarian teratoma (in 3 patients), ovarian cyst (in 2 patients, of which one had a concomitant formation in the form of a paratubic cyst). The size of the tumors, measured before surgery using ultrasound and computed tomography, was 1.8±2.4 cm (median 0.4 cm [0.4; 2.5]). Cystic formations were located mainly on the left (3:2). The average age of patients at the time of surgery was 12.2±2.0 years (median 11.0 years [10.0; 13.0]), the average body weight was 49.8±10.1 kg (median 52.0 [41.0; 56.0]). The lowest body weight of an operated child was 38 kg. Robot-assisted procedures included ovarian cystectomy (in 2 patients), teratoma enucleation (in 3 patients), and excision of a paratubal cyst (in 1 patient). The average surgery duration was 74.0±22.2 minutes (median 75.0 [70.0; 85.0]). During surgery, there were no complications like bleeding from the ovarian tissue or damage to neighboring organs. Cystic contents in all cases was clear liquid without pathological impurities. Histological findings established the following final diagnoses: “Serous ovarian cystadenoma” (in 2 patients), “Mature cystic teratoma” (in 1), “Mature cystic-solid teratoma” (in 2), “Paratubal cyst” (in 1). The length of stay of patients in the intensive care unit was 3.2±0.4 hours (median 3.0 [3.0; 3.0]), hospitalization lasted for 4.0±1.5 days (4.0 [3.0; 4.0]). Ultrasound examination in 1, 3 and 6 months after the surgery revealed no signs of recurrence of the disease. CONCLUSION: Our trial has reached the main goal―to provide 3D visual control of the targeted anatomic area of surgical intervention and safe removal of pathological formations with preservation of the ovarian tissue. Thus, robot-assisted manipulations in girls with gynecological pathologies are possible.

  • Open Access

    Robot-assisted ureteroureterostomy in a child with mid-ureteral stricture: a case report

    by Yury A. Kozlov, Alexander P. Rozhanski, Marina V. Makarochkina, Eduard V. Sapukhin, Alexey S. Strashinsky, Anna O. Ryakhina, Yulia P. Semshchikova, Страшинский Алексей Сергеевич, Съемщикова Юлия Павловна

    Congenital ureteral stricture in the mid-portion is a rare cause of upper urinary tract obstruction in children, and currently no established protocols for its surgical treatment exist. A retrospectively analyzed medical history is presented of a 2-year-old patient diagnosed with right mid-ureteral stricture, accompanied by impaired urinary outflow and reduced renal function. Ultrasound scanning and contrast-enhanced computed tomography were used to establish the diagnosis. Surgical treatment was performed using robotic assistance with resection of the stenotic segment and ureteroureterostomy. Intraoperatively, the proximal ureter was transected at the level of the narrowing toward the distal portion. The length of the resected healthy ureter corresponded to the diameter of the dilated segment. The ureteral anastomosis was created over a stent previously placed in the renal pelvis by cystoscopy. After preparation of the ureteral ends, the anastomosis was completed with subsequent drainage. The procedure was successful, with no intraoperative complications. Total operative time was 180 minutes, including 15 minutes for robotic docking. The entire operation was performed robotically without conversion to laparoscopy or open surgery. The stenotic segment measured approximately 8 mm. Postoperatively, the patient was monitored in the intensive care unit for 12 hours. He was discharged home 10 days after surgery, one day after Foley catheter removal. Histological examination of the stenotic segment revealed expansion of the submucosa with fibrosis, lymphocytic inflammation, and thickening of the muscular layer with fiber destruction. Four weeks after surgery, the ureteral stent was successfully removed by cystoscopy. In the long-term postoperative period, ultrasound examination revealed narrowing of the upper ureter to 4 mm. No stenosis was detected at the site of the ureteroureterostomy during follow-up. Robot-assisted laparoscopic ureteroureterostomy is a reliable and effective minimally invasive approach to the treatment of congenital mid-ureteral stricture, with no adverse short- or long-term outcomes during follow-up.

  • Open Access

    Robot-Assisted Thoracoscopic Resection of Thymus in a Child with Thymic Cyst

    by Yuri A. Kozlov, Alexander P. Rozhansky, Simon S. Poloyan, Eduard V. Sapukhin, Alexey S. Strashinsky, Marina V. Makarochkina, Anna O. Ryakhina, Julia P. Syemschikova, Страшинский Алексей Сергеевич, Съемщикова Юлия Павловна

    Thymic cysts are rare lesions of the thymus gland. Open surgical resection is associated with trauma and may lead to postoperative complications such as pain, blood loss, and wound infection. Over the past decades, minimally invasive surgical techniques have been actively developed. The authors conducted a retrospective review of the medical history of a 15-year-old adolescent with a thymic cyst accompanied by exertional pain. The final diagnosis was established using contrast-enhanced computed tomography of the chest. The surgical intervention was performed using a robot-assisted technique. The Versius surgical robot (Cambridge Medical Robotics, UK) was used. Partial thymectomy of the left lobe was employed as the surgical technique. Following adhesiolysis between the tumor and the upper lobe of the left lung, adequate visualization of the tumor was achieved. The inferior horn of the thymus, together with the cyst, was isolated. The thymic tissue at the level of the left upper horn was then transected at the border of healthy tissue and extracted from the thoracic cavity through an enlarged incision at the assistant port site using an Endocatch bag. The operation was successfully performed without intraoperative difficulties or complications, with total duration was 120 minutes. Of this, 20 minutes were required for docking the robot. The procedure was fully robot-assisted with no conversion to thoracoscopic or open surgery. Histological examination revealed a cyst wall lined with simple squamous epithelium and filled with detritus showing signs of infection. The patient remained in the intensive care unit for 20 hours. Tracheal extubation was performed shortly after surgery, and the patient was discharged home on postoperative day 12. The chest drain was removed by the end of the first postoperative day. Robot-assisted thoracoscopic partial thymectomy is a safe and effective minimally invasive approach for the treatment of congenital thymic cysts, which is accompanied by a favorable postoperative course.