Andrey A. Marchuk
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Andrey A. Marchuk has a total of 71 co-authors. Here are the top co-authors by number of shared publications:
- Yuri Andreevich Kozlov
Irkutsk Regional Children's Clinical Hospital, Irkutsk, Russia
42 shared publications - Alexander P. Rozhanskii
Irkutsk Regional Children's Clinical Hospital, Irkutsk, Russia
40 shared publications - Edward Vladimirovich Sapukhin
Children’s Regional Clinical Hospital, Irkutsk
31 shared publications - Simon Stepanovich Poloyan
Children’s Regional Clinical Hospital; Irkutsk State Medical University
28 shared publications - Alexey Sergeevich Strashinsky
Children’s Regional Clinical Hospital, Irkutsk
27 shared publications - Marina V. Makarochkina
Children’s Regional Clinical Hospital, Irkutsk
25 shared publications
Latest Publications
- 9 October 2026
- Published by Pediatria, Ltd. in Pediatria. Journal named after G.N. Speransky
- Vol. 105 (5)
USE OF ROBOT-ASSISTED CULP-DEWEERD FLAP PYELOPLASTY FOR THE TREATMENT OF RECURRENT URETEROPELVIC JUNCTION STENOSIS: A CASE REPORT
One of the methods used to treat recurrent or anatomically complex cases of obstruction at the ureteropelvic junction that are not amenable to standard procedures is flap pyeloplasty, first described by O. Culp and J. DeWeerd and implemented by the authors of this study in a robotic version. This paper presents a case of robot-assisted treatment of a long-segment (>2 cm) stenosis of the proximal ureter causing recurrent ureteropelvic junction (UPJ) obstruction using spiral flap pyeloplasty performed in the manner of the Culp–DeWeerd procedure. The patient was an 8-year-old boy who had undergone laparoscopic Anderson–Hynes pyeloplasty 4 years previously. In the postoperative period, the child developed right renal pelvic dilatation of up to 5 cm, accompanied by recurrent urinary tract infections and pain syndrome. The surgical intervention consisted of the Culp–DeWeerd technique performed using a robotic approach. The procedure began with meticulous adhesiolysis and excision of scar tissue in the UPJ area. The stricture zone of the proximal ureter, starting from the distal margin, was incised longitudinally upward. Next, a spiral flap was fashioned from the renal pelvis tissues, which was mobilized downward and sutured to the edges of the ureteral incision, forming a wide UPJ. The operative time was 180 minutes, including cystoscopy and JJ-stent placement – 20 minutes, robot docking time – 15 minutes, and the duration of the main surgical stage – 145 minutes. The urinary catheter was removed on the 1st postoperative day. The drainage tube was removed on the 5th postoperative day when the anastomosis was confirmed to be competent. The percutaneous pelvic drainage catheter was removed on the 7th day, after which the patient was discharged for outpatient follow-up. The ureteral stent was removed 1 month after surgery. After stent removal, control ultrasound demonstrated a reduction in the anteroposterior pelvic diameter to 1.5 cm. Conclusion: The presented experience demonstrates the reproducibility, safety, and effectiveness of the robot-assisted approach in the treatment of long-segment recurrent stenoses of the upper third of the ureter.
- 9 October 2026
- Published by Pediatria, Ltd. in Pediatria. Journal named after G.N. Speransky
- Vol. 105 (5)
USE OF ROBOT-ASSISTED CULP-DEWEERD FLAP PYELOPLASTY FOR THE TREATMENT OF RECURRENT URETEROPELVIC JUNCTION STENOSIS: A CASE REPORT
One of the methods used to treat recurrent or anatomically complex cases of obstruction at the ureteropelvic junction that are not amenable to standard procedures is flap pyeloplasty, first described by O. Culp and J. DeWeerd and implemented by the authors of this study in a robotic version. This paper presents a case of robot-assisted treatment of a long-segment (>2 cm) stenosis of the proximal ureter causing recurrent ureteropelvic junction (UPJ) obstruction using spiral flap pyeloplasty performed in the manner of the Culp–DeWeerd procedure. The patient was an 8-year-old boy who had undergone laparoscopic Anderson–Hynes pyeloplasty 4 years previously. In the postoperative period, the child developed right renal pelvic dilatation of up to 5 cm, accompanied by recurrent urinary tract infections and pain syndrome. The surgical intervention consisted of the Culp–DeWeerd technique performed using a robotic approach. The procedure began with meticulous adhesiolysis and excision of scar tissue in the UPJ area. The stricture zone of the proximal ureter, starting from the distal margin, was incised longitudinally upward. Next, a spiral flap was fashioned from the renal pelvis tissues, which was mobilized downward and sutured to the edges of the ureteral incision, forming a wide UPJ. The operative time was 180 minutes, including cystoscopy and JJ-stent placement – 20 minutes, robot docking time – 15 minutes, and the duration of the main surgical stage – 145 minutes. The urinary catheter was removed on the 1st postoperative day. The drainage tube was removed on the 5th postoperative day when the anastomosis was confirmed to be competent. The percutaneous pelvic drainage catheter was removed on the 7th day, after which the patient was discharged for outpatient follow-up. The ureteral stent was removed 1 month after surgery. After stent removal, control ultrasound demonstrated a reduction in the anteroposterior pelvic diameter to 1.5 cm. Conclusion: The presented experience demonstrates the reproducibility, safety, and effectiveness of the robot-assisted approach in the treatment of long-segment recurrent stenoses of the upper third of the ureter.
- 9 October 2026
- Published by Pediatria, Ltd. in Pediatria. Journal named after G.N. Speransky
- Vol. 105 (5)
ROBOT-ASSISTED OPERATIONS IN ABDOMINAL SURGERY IN CHILDREN: A RETROSPECTIVE SINGLE-CENTER STUDY
Robot-assisted surgery is a new direction in pediatrics. Minimally invasive technologies have long become the gold standard in the treatment of surgical diseases in children, but robotic technologies still remain the prerogative of a limited number of advanced surgical centers. Objective: To present our own experience of performing robot-assisted operations on abdominal organs in children for the period from December 2022 to December 2025. Materials and Methods: This was a single-center retrospective uncontrolled study of patient demographics and outcomes of surgical interventions performed using the Versius robotic surgical system (CMR, UK) in children with abdominal pathology. All operations were performed at the Irkutsk State Regional Children's Clinical Hospital from December 2022 to December 2025. Patient demographic data, perioperative parameters, and follow-up data were analyzed. Results: The study included 96 patients, of whom 38 (39.6%) were boys and 58 (60.4%) were girls. Surgical interventions were distributed as follows: splenic cyst fenestration – 20 (20.8%) cases; cholecystectomy – 17 (17.7%) cases; Nissen fundoplication – 17 (17.7%) cases; appendectomy – 15 (15.6%) cases; Heller cardiomyotomy with Dor fundoplication – 5 (5.2%) cases; resection of ovarian masses – 5 (5.2%) cases; hepatic cyst fenestration – 3 (3.1%) cases; hepaticoduodenostomy – 3 (3.1%) cases; resection of small intestinal duplication – 3 (3.1%) cases; distal pancreatectomy with spleen preservation – 2 (2.1%) cases; duodenojejunostomy – 2 (2.1%) cases; removal of gastrointestinal foreign bodies – 2 (2.1%) cases; resection of duodenal duplication – 1 (1%) case; hiatal plasty – 1 (1%) case. The mean age of patients at the time of surgery was 11.0±4.0 years, mean weight was 42.6±20.2 kg. The operations were not accompanied by conversions to laparotomy or conventional laparoscopy, nor by intraoperative complications. In the early postoperative period, no complications related to the surgical intervention were noted. Follow-up of all patients was performed at 1, 3, 6, and 12 months after surgery, with no relapses or long-term consequences of the surgical operations observed. Conclusion: The presented experience demonstrates that robot-assisted operations on abdominal organs are a safe and effective method for treating surgical abdominal pathology in children. Comparative studies are needed to determine their place among other minimally invasive treatment methods.
- 9 October 2026
- Published by Pediatria, Ltd. in Pediatria. Journal named after G.N. Speransky
- Vol. 105 (5)
ROBOT-ASSISTED OPERATIONS IN ABDOMINAL SURGERY IN CHILDREN: A RETROSPECTIVE SINGLE-CENTER STUDY
Robot-assisted surgery is a new direction in pediatrics. Minimally invasive technologies have long become the gold standard in the treatment of surgical diseases in children, but robotic technologies still remain the prerogative of a limited number of advanced surgical centers. Objective: To present our own experience of performing robot-assisted operations on abdominal organs in children for the period from December 2022 to December 2025. Materials and Methods: This was a single-center retrospective uncontrolled study of patient demographics and outcomes of surgical interventions performed using the Versius robotic surgical system (CMR, UK) in children with abdominal pathology. All operations were performed at the Irkutsk State Regional Children's Clinical Hospital from December 2022 to December 2025. Patient demographic data, perioperative parameters, and follow-up data were analyzed. Results: The study included 96 patients, of whom 38 (39.6%) were boys and 58 (60.4%) were girls. Surgical interventions were distributed as follows: splenic cyst fenestration – 20 (20.8%) cases; cholecystectomy – 17 (17.7%) cases; Nissen fundoplication – 17 (17.7%) cases; appendectomy – 15 (15.6%) cases; Heller cardiomyotomy with Dor fundoplication – 5 (5.2%) cases; resection of ovarian masses – 5 (5.2%) cases; hepatic cyst fenestration – 3 (3.1%) cases; hepaticoduodenostomy – 3 (3.1%) cases; resection of small intestinal duplication – 3 (3.1%) cases; distal pancreatectomy with spleen preservation – 2 (2.1%) cases; duodenojejunostomy – 2 (2.1%) cases; removal of gastrointestinal foreign bodies – 2 (2.1%) cases; resection of duodenal duplication – 1 (1%) case; hiatal plasty – 1 (1%) case. The mean age of patients at the time of surgery was 11.0±4.0 years, mean weight was 42.6±20.2 kg. The operations were not accompanied by conversions to laparotomy or conventional laparoscopy, nor by intraoperative complications. In the early postoperative period, no complications related to the surgical intervention were noted. Follow-up of all patients was performed at 1, 3, 6, and 12 months after surgery, with no relapses or long-term consequences of the surgical operations observed. Conclusion: The presented experience demonstrates that robot-assisted operations on abdominal organs are a safe and effective method for treating surgical abdominal pathology in children. Comparative studies are needed to determine their place among other minimally invasive treatment methods.
- 30 September 2026
- Published by ECO-Vector LLC (Publications) in Russian Journal of Pediatric Surgery, Anesthesia and Intensive Care
- Vol. 26 (3) , 415-422
Robot-assisted removal of cystic ileal duplication with intestinal wall reconstruction: a case report
Gastrointestinal duplications are rare congenital anomalies that can occur anywhere along the gastrointestinal tract, from the oral cavity to the anus. Relatively recently, robotic technologies have been used to treat digestive tract duplications; however, the number of publications is limited to isolated reports. This article presents a clinical case of a 5-year-old female patient weighing 16 kg who was admitted to the Irkutsk State Regional Children’s Clinical Hospital due to an abdominal mass detected on ultrasound. On repeat ultrasound of the abdominal cavity, a round, fluid-filled mass with clear, even contours, up to 4 cm in size, located in the right parts of the abdomen, was detected. According to multislice computed tomography, a spherical thin-walled cyst 4 cm in diameter was visualized, with homogeneous content not enhancing in all scanning phases, with a densitometric value of about 25 Hounsfield units, and without a parietal component inside. Laboratory test results were within reference ranges. Robot-assisted resection of the cystic mass was proposed to the patient’s legal representatives. The surgery was performed using the Versius robotic surgical system (CMR, UK). A 4 cm cystic mass was identified 30 cm from the ileocecal junction, located along the mesenteric edge of the ileum. Excision of the mass began with an incision into the muscular layer of the enteric cyst. Subsequently, the mucosa was grasped with an atraumatic bipolar clamp, and the mass was excised. The time required for docking the robotic surgical system was 20 min. The console time was 90 min. The subsequent course of the early postoperative period in the patient was uneventful, as a result of which she was discharged for outpatient follow-up on the seventh postoperative day. Histopathological examination of the specimen revealed a cystic duplication whose inner lining was represented by the ileal mucosa with islands of pancreatic tissue with erosions and ulcerations. Robot-assisted excision of a cystic ileal duplication under the conditions of the limited anatomical space of the child’s abdominal cavity enabled precise removal of the enterocyst while preserving the “parent” intestinal segment.
- 30 September 2026
- Published by ECO-Vector LLC (Publications) in Russian Journal of Pediatric Surgery, Anesthesia and Intensive Care
- Vol. 26 (3) , 415-422
Robot-assisted removal of cystic ileal duplication with intestinal wall reconstruction: a case report
Gastrointestinal duplications are rare congenital anomalies that can occur anywhere along the gastrointestinal tract, from the oral cavity to the anus. Relatively recently, robotic technologies have been used to treat digestive tract duplications; however, the number of publications is limited to isolated reports. This article presents a clinical case of a 5-year-old female patient weighing 16 kg who was admitted to the Irkutsk State Regional Children’s Clinical Hospital due to an abdominal mass detected on ultrasound. On repeat ultrasound of the abdominal cavity, a round, fluid-filled mass with clear, even contours, up to 4 cm in size, located in the right parts of the abdomen, was detected. According to multislice computed tomography, a spherical thin-walled cyst 4 cm in diameter was visualized, with homogeneous content not enhancing in all scanning phases, with a densitometric value of about 25 Hounsfield units, and without a parietal component inside. Laboratory test results were within reference ranges. Robot-assisted resection of the cystic mass was proposed to the patient’s legal representatives. The surgery was performed using the Versius robotic surgical system (CMR, UK). A 4 cm cystic mass was identified 30 cm from the ileocecal junction, located along the mesenteric edge of the ileum. Excision of the mass began with an incision into the muscular layer of the enteric cyst. Subsequently, the mucosa was grasped with an atraumatic bipolar clamp, and the mass was excised. The time required for docking the robotic surgical system was 20 min. The console time was 90 min. The subsequent course of the early postoperative period in the patient was uneventful, as a result of which she was discharged for outpatient follow-up on the seventh postoperative day. Histopathological examination of the specimen revealed a cystic duplication whose inner lining was represented by the ileal mucosa with islands of pancreatic tissue with erosions and ulcerations. Robot-assisted excision of a cystic ileal duplication under the conditions of the limited anatomical space of the child’s abdominal cavity enabled precise removal of the enterocyst while preserving the “parent” intestinal segment.
- Open Access
- 19 August 2026
- Published by Science for Children Foundation in Pediatric Hematology/Oncology and Immunopathology
- Vol. 25 (3) , 188-195
Robot-assisted treatment of a simple liver cyst in a child
Introduction. This study presents the first experience of robotic fenestration of a liver cyst using the Versius system and assesses the feasibility and safety of this procedure in children. Clinical case. The study presents a case of successful treatment of a simple liver cyst in a 15-year-old boy who had been complaining of discomfort in the right hypochondrium and occasional pain for 6 months prior to admission to the children's hospital. Visualization data confirmed the ultrasound finding and identified a simple liver cyst with a diameter of 7 cm with a thin avascular capsule filled with liquid contents. The operation was performed using the Versius robotic system developed by CMR (UK). The main stages of the operation included: cyst puncture and aspiration of its contents; excision of the cyst dome (fenestration) as close to the liver parenchyma as possible; destruction of the remaining epithelium of the posterior wall of the cyst using argon plasma photocoagulation to prevent recurrence of the disease. The patient's age at the time of surgery was 15 years. The cyst was located in segment VI of the right lobe of the liver. The duration of the surgery was 130 min, the robot installation time was 15 min, the main console time was 115 min. The total blood loss was no more than 5 ml. The surgery was not accompanied by conversion to laparoscopic or open surgery. During the surgical interventions, no complications associated with trauma to the bile ducts, liver vessels, or adjacent anatomical structures were noted. Recovery was smooth and quick, and the patient was discharged from the hospital on the 3rd postoperative day. Pathological examination of the resected sample showed a benign liver cyst. Conclusion. Robot-assisted fenestration combined with simultaneous argon plasma photocoagulation of the residual cavity is a feasible option for the treatment of simple liver cysts and is accompanied by a favorable course of the postoperative period.
- 19 August 2026
- Published by Science for Children Foundation in Pediatric Hematology/Oncology and Immunopathology
- Vol. 25 (3) , 188-195
Open AccessRobot-assisted treatment of a simple liver cyst in a child
Introduction. This study presents the first experience of robotic fenestration of a liver cyst using the Versius system and assesses the feasibility and safety of this procedure in children. Clinical case. The study presents a case of successful treatment of a simple liver cyst in a 15-year-old boy who had been complaining of discomfort in the right hypochondrium and occasional pain for 6 months prior to admission to the children's hospital. Visualization data confirmed the ultrasound finding and identified a simple liver cyst with a diameter of 7 cm with a thin avascular capsule filled with liquid contents. The operation was performed using the Versius robotic system developed by CMR (UK). The main stages of the operation included: cyst puncture and aspiration of its contents; excision of the cyst dome (fenestration) as close to the liver parenchyma as possible; destruction of the remaining epithelium of the posterior wall of the cyst using argon plasma photocoagulation to prevent recurrence of the disease. The patient's age at the time of surgery was 15 years. The cyst was located in segment VI of the right lobe of the liver. The duration of the surgery was 130 min, the robot installation time was 15 min, the main console time was 115 min. The total blood loss was no more than 5 ml. The surgery was not accompanied by conversion to laparoscopic or open surgery. During the surgical interventions, no complications associated with trauma to the bile ducts, liver vessels, or adjacent anatomical structures were noted. Recovery was smooth and quick, and the patient was discharged from the hospital on the 3rd postoperative day. Pathological examination of the resected sample showed a benign liver cyst. Conclusion. Robot-assisted fenestration combined with simultaneous argon plasma photocoagulation of the residual cavity is a feasible option for the treatment of simple liver cysts and is accompanied by a favorable course of the postoperative period.
- Open Access
- 19 August 2026
- Published by Science for Children Foundation in Pediatric Hematology/Oncology and Immunopathology
- Vol. 25 (3) , 180-187
Robot-assisted laparoscopic adrenalectomy – first experience of use in children
The aim of this publication is to demonstrate the reproducibility and safety of the robotic-assisted approach in children with adrenal tumors. Clinical case. A 15-year-old adolescent with an adrenal tumor was diagnosed incidentally during a routine visit to the emergency room due to the sudden onset of a right-sided hydrocele. After performing an ultrasound examination, a 43 × 41 mm tumor was detected in the projection of the right adrenal gland. Subsequent computed tomography confirmed the organ affiliation of the tumor associated with the right adrenal gland. Robot-assisted laparoscopic adrenalectomy was performed using the Versius surgical robot. Initially, the hepatic flexure of the colon was mobilized, exposing the inferior vena cava, spread out on the surface of the tumor. The adrenal vein was isolated, ligated using Hem-o-lok® clips (Teleflex, USA) and transected. Then the adrenal gland together with the tumor was carefully mobilized from the medial side by coagulation of adhesions connecting it to the inferior vena cava. Small adrenal vessels were coagulated with bi- and monopolar robotic instruments (Maryland clamp and hook) from the cranial and lateral surfaces, which allowed complete tumor resection. The adrenal gland was removed externally using a tissue removal bag. Tumor resection was performed completely robotically without conversion to laparoscopy or open surgery. Tumor resection was macroscopically complete. The duration of the operation was 180 min, the net console time was 165 min. We did not observe any intraoperative complications, such as bleeding, damage to adjacent organs, injuries associated with the impact of manipulators on the anterior abdominal wall. The child was discharged from the hospital on the 5th postoperative day. The postoperative period was uneventful. The removed pathological tissue sample, upon histological examination, corresponded to a ganglioneuroma formed from mature ganglion cells and sympathetic nerve ganglia. Conclusion. The presented case demonstrates that adrenalectomy can be performed using robotics due to its advantages, which include improved visualization and increased maneuverability when working with robotic instruments.
- 19 August 2026
- Published by Science for Children Foundation in Pediatric Hematology/Oncology and Immunopathology
- Vol. 25 (3) , 180-187
Open AccessRobot-assisted laparoscopic adrenalectomy – first experience of use in children
The aim of this publication is to demonstrate the reproducibility and safety of the robotic-assisted approach in children with adrenal tumors. Clinical case. A 15-year-old adolescent with an adrenal tumor was diagnosed incidentally during a routine visit to the emergency room due to the sudden onset of a right-sided hydrocele. After performing an ultrasound examination, a 43 × 41 mm tumor was detected in the projection of the right adrenal gland. Subsequent computed tomography confirmed the organ affiliation of the tumor associated with the right adrenal gland. Robot-assisted laparoscopic adrenalectomy was performed using the Versius surgical robot. Initially, the hepatic flexure of the colon was mobilized, exposing the inferior vena cava, spread out on the surface of the tumor. The adrenal vein was isolated, ligated using Hem-o-lok® clips (Teleflex, USA) and transected. Then the adrenal gland together with the tumor was carefully mobilized from the medial side by coagulation of adhesions connecting it to the inferior vena cava. Small adrenal vessels were coagulated with bi- and monopolar robotic instruments (Maryland clamp and hook) from the cranial and lateral surfaces, which allowed complete tumor resection. The adrenal gland was removed externally using a tissue removal bag. Tumor resection was performed completely robotically without conversion to laparoscopy or open surgery. Tumor resection was macroscopically complete. The duration of the operation was 180 min, the net console time was 165 min. We did not observe any intraoperative complications, such as bleeding, damage to adjacent organs, injuries associated with the impact of manipulators on the anterior abdominal wall. The child was discharged from the hospital on the 5th postoperative day. The postoperative period was uneventful. The removed pathological tissue sample, upon histological examination, corresponded to a ganglioneuroma formed from mature ganglion cells and sympathetic nerve ganglia. Conclusion. The presented case demonstrates that adrenalectomy can be performed using robotics due to its advantages, which include improved visualization and increased maneuverability when working with robotic instruments.
- 30 June 2026
- Published by ECO-Vector LLC (Publications) in Russian Journal of Pediatric Surgery, Anesthesia and Intensive Care
- Vol. 16 (2) , 271-278
Mature thoracoabdominal teratoma in a teenager: a case report
Teratomas are neoplasms composed of cellular elements derived from the three germ layers: endoderm, mesoderm, and ectoderm. The most common sites of teratomas are the sacrococcygeal region and ovaries (51%–60%). However, other locations are also possible: testes, the retroperitoneal space, the stomach, the neck, and the floor of the oral cavity. Teratomas in two different body cavities are extremely rare. A 15-year-old girl presented with a mass in the chest that was an incidental finding on routine chest X-ray. Subsequent inpatient workup (multislice CT and aortoarteriography) showed that the lesion had a thoracoabdominal location with a large feeding artery arising from the upper abdominal aorta. Surgery involved a right posterolateral thoracotomy through the 7th intercostal space. During the procedure, dense adhesion of the cystic mass to the right lower lobe was found. After mobilization of the tumor from the lung and ligation of its vascular pedicle, it was found that the tumor extended into the abdominal cavity through the esophageal hiatus. The diaphragmatic crura were divided, and the cyst was completely mobilized bluntly from the esophagus and stomach. The tumor was removed from the pleural cavity, and damaged tissues were repaired. Operating time was 155 minutes. There were no intraoperative complications such as bleeding or esophageal or gastric perforation. The chest tube was removed on day 2, and ultrasound showed no hydrothorax. Histopathology revealed a mature cystic teratoma. Follow-up multislice CT of the chest and abdomen showed no residual tumor. The relevance of this report lies in the extreme rarity of thoracoabdominal mature teratomas in children and the lack of standardized surgical guidelines. This description of successful radical resection of a large tumor via a single thoracotomy approach broadens the clinical understanding of the topographic anatomy of such tumors and demonstrates the feasibility of minimizing surgical trauma when the tumor involves two body cavities.
- 30 June 2026
- Published by ECO-Vector LLC (Publications) in Russian Journal of Pediatric Surgery, Anesthesia and Intensive Care
- Vol. 16 (2) , 271-278
Mature thoracoabdominal teratoma in a teenager: a case report
Teratomas are neoplasms composed of cellular elements derived from the three germ layers: endoderm, mesoderm, and ectoderm. The most common sites of teratomas are the sacrococcygeal region and ovaries (51%–60%). However, other locations are also possible: testes, the retroperitoneal space, the stomach, the neck, and the floor of the oral cavity. Teratomas in two different body cavities are extremely rare. A 15-year-old girl presented with a mass in the chest that was an incidental finding on routine chest X-ray. Subsequent inpatient workup (multislice CT and aortoarteriography) showed that the lesion had a thoracoabdominal location with a large feeding artery arising from the upper abdominal aorta. Surgery involved a right posterolateral thoracotomy through the 7th intercostal space. During the procedure, dense adhesion of the cystic mass to the right lower lobe was found. After mobilization of the tumor from the lung and ligation of its vascular pedicle, it was found that the tumor extended into the abdominal cavity through the esophageal hiatus. The diaphragmatic crura were divided, and the cyst was completely mobilized bluntly from the esophagus and stomach. The tumor was removed from the pleural cavity, and damaged tissues were repaired. Operating time was 155 minutes. There were no intraoperative complications such as bleeding or esophageal or gastric perforation. The chest tube was removed on day 2, and ultrasound showed no hydrothorax. Histopathology revealed a mature cystic teratoma. Follow-up multislice CT of the chest and abdomen showed no residual tumor. The relevance of this report lies in the extreme rarity of thoracoabdominal mature teratomas in children and the lack of standardized surgical guidelines. This description of successful radical resection of a large tumor via a single thoracotomy approach broadens the clinical understanding of the topographic anatomy of such tumors and demonstrates the feasibility of minimizing surgical trauma when the tumor involves two body cavities.
- Open Access
- 30 March 2026
- Published by ECO-Vector LLC (Publications) in Russian Journal of Pediatric Surgery, Anesthesia and Intensive Care
- Vol. 26 (1) , 127-136
Robot-assisted resection of a common bile duct cyst with hepaticoduodenostomy in a child: a case report
A choledochal cyst is a rare congenital anomaly of the bile ducts. In recent years, surgical approaches to its treatment have evolved from laparotomy to laparoscopy and robot-assisted surgery. This article analyzes the clinical course of a 4-year-old girl diagnosed with a choledochal cyst. The patient’s main complaints were recurrent upper abdominal pain accompanied by a single episode of jaundice at age 3 years. At the time of admission, the patient’s symptom duration was 1.5 years. Preoperative evaluation included liver function tests, coagulation profile, ultrasound, and magnetic resonance cholangiopancreatography, which revealed a type I choledochal cyst measuring 27.3 mm in diameter. Robot-assisted choledochal cyst resection followed these principles: cyst dissection with clipping of the distal common hepatic duct, proximal cyst dissection with transverse transection at the level of the non-dilated common hepatic duct, and hepaticoduodenostomy creation. Operative time was 240 minutes: docking time, 20 minutes; console time, 220 minutes. Enteral nutrition was initiated on postoperative day 3, and full enteral nutrition was achieved on postoperative day 5. The child demonstrated successful postoperative recovery, with early transition to a full enteral diet and discharge for outpatient follow-up on postoperative day 7. At follow-up, the child had normal weight and height parameters, no pain, and normal bile duct diameter on liver ultrasound. Compared with laparoscopy, robot-assisted surgery for congenital choledochal cysts in children offers advantages including enhanced visualization and exceptional robotic instrument maneuverability, resulting in less tissue damage, greater precision in hepaticoduodenostomy creation, and faster patient recovery. This case demonstrates the potential of robot-assisted surgery for treating children with hepatobiliary pathology.
- 30 March 2026
- Published by ECO-Vector LLC (Publications) in Russian Journal of Pediatric Surgery, Anesthesia and Intensive Care
- Vol. 26 (1) , 127-136
Open AccessRobot-assisted resection of a common bile duct cyst with hepaticoduodenostomy in a child: a case report
A choledochal cyst is a rare congenital anomaly of the bile ducts. In recent years, surgical approaches to its treatment have evolved from laparotomy to laparoscopy and robot-assisted surgery. This article analyzes the clinical course of a 4-year-old girl diagnosed with a choledochal cyst. The patient’s main complaints were recurrent upper abdominal pain accompanied by a single episode of jaundice at age 3 years. At the time of admission, the patient’s symptom duration was 1.5 years. Preoperative evaluation included liver function tests, coagulation profile, ultrasound, and magnetic resonance cholangiopancreatography, which revealed a type I choledochal cyst measuring 27.3 mm in diameter. Robot-assisted choledochal cyst resection followed these principles: cyst dissection with clipping of the distal common hepatic duct, proximal cyst dissection with transverse transection at the level of the non-dilated common hepatic duct, and hepaticoduodenostomy creation. Operative time was 240 minutes: docking time, 20 minutes; console time, 220 minutes. Enteral nutrition was initiated on postoperative day 3, and full enteral nutrition was achieved on postoperative day 5. The child demonstrated successful postoperative recovery, with early transition to a full enteral diet and discharge for outpatient follow-up on postoperative day 7. At follow-up, the child had normal weight and height parameters, no pain, and normal bile duct diameter on liver ultrasound. Compared with laparoscopy, robot-assisted surgery for congenital choledochal cysts in children offers advantages including enhanced visualization and exceptional robotic instrument maneuverability, resulting in less tissue damage, greater precision in hepaticoduodenostomy creation, and faster patient recovery. This case demonstrates the potential of robot-assisted surgery for treating children with hepatobiliary pathology.
- 11 March 2026
- Published by ECO-Vector LLC (Publications) in Russian Journal of Pediatric Surgery
- Vol. 30 (1) , 65-72
Robot-assisted heminefrectomy in a patient with duplex kidney: а case report
Robot-assisted surgery is a relatively new technology that enables a wide range of urological procedures to be performed using a minimally invasive approach. Various studies have shown that this technology is feasible and safe in most pediatric patients. The authors of this study conducted a retrospective review of the medical history of a child with a doubling of the upper urinary tract, accompanied by obstructive damage to the upper segment of the ureter with loss of its excretory function. The data collection included the patient's medical history and demographic data, diagnosis, type of surgery, total time of surgery, outcome of surgery, and the anatomical and functional state of the kidney during follow-up. A 12-year-old girl presented to the surgical department with complaints of recurrent urinary tract infections and right flank pain for the last year of her life. Robot-assisted laparoscopic heminephrectomy (RALHN) was performed using the Versius surgical robot. The upper segment ureter was transected at the lower pole of the kidney. The afunctional portion of the kidney was dissected from the normal kidney using a bipolar coagulation clamp. The lower segment incision edges were left open. The distal ureter was then isolated and sealed with a clip. The robot-assisted laparoscopic heminephrectomy procedure was successfully performed without intraoperative complications. The surgery duration was 225 minutes, including 20 minutes for robotic insertion. The total console time was 205 minutes. The drainage tube was removed after a follow-up ultrasound examination on the second day. The stent remained in the lower segment ureter until its removal six weeks after surgery. A repeat ultrasound examination performed postoperatively demonstrated no dilation of the lower segment pelvis or fluid collections in the area of the right kidney. Blood flow to the residual segment of the right kidney was not impaired. The advantages of the robotic approach to treating upper urinary tract duplication, including improved instrument maneuverability and 3D visualization, make it a safe and effective alternative to open or laparoscopic surgery in children.
- 11 March 2026
- Published by ECO-Vector LLC (Publications) in Russian Journal of Pediatric Surgery
- Vol. 30 (1) , 65-72
Robot-assisted heminefrectomy in a patient with duplex kidney: а case report
Robot-assisted surgery is a relatively new technology that enables a wide range of urological procedures to be performed using a minimally invasive approach. Various studies have shown that this technology is feasible and safe in most pediatric patients. The authors of this study conducted a retrospective review of the medical history of a child with a doubling of the upper urinary tract, accompanied by obstructive damage to the upper segment of the ureter with loss of its excretory function. The data collection included the patient's medical history and demographic data, diagnosis, type of surgery, total time of surgery, outcome of surgery, and the anatomical and functional state of the kidney during follow-up. A 12-year-old girl presented to the surgical department with complaints of recurrent urinary tract infections and right flank pain for the last year of her life. Robot-assisted laparoscopic heminephrectomy (RALHN) was performed using the Versius surgical robot. The upper segment ureter was transected at the lower pole of the kidney. The afunctional portion of the kidney was dissected from the normal kidney using a bipolar coagulation clamp. The lower segment incision edges were left open. The distal ureter was then isolated and sealed with a clip. The robot-assisted laparoscopic heminephrectomy procedure was successfully performed without intraoperative complications. The surgery duration was 225 minutes, including 20 minutes for robotic insertion. The total console time was 205 minutes. The drainage tube was removed after a follow-up ultrasound examination on the second day. The stent remained in the lower segment ureter until its removal six weeks after surgery. A repeat ultrasound examination performed postoperatively demonstrated no dilation of the lower segment pelvis or fluid collections in the area of the right kidney. Blood flow to the residual segment of the right kidney was not impaired. The advantages of the robotic approach to treating upper urinary tract duplication, including improved instrument maneuverability and 3D visualization, make it a safe and effective alternative to open or laparoscopic surgery in children.
- 21 January 2026
- Published by ECO-Vector LLC (Publications) in Russian Journal of Pediatric Surgery
- Vol. 29 (6) , 414-421
Robot-assisted laparoscopic extravesical ureteral reimplantation in a child with primary obstructive megaureter: а case report
The primary obstructive megaureter accounts for approximately 10% of all uropathies. The overall primary obstructive megaureter incidence is 1:2000 newborns. About 80% of perinatally diagnosed cases of primary obstructive megaureter resolve spontaneously during the first years of a child's life, and therefore most cases of the disease are subject to conservative treatment. Increasing obstruction and decreased renal function are indications for surgical treatment. The present article describes a case of 8 years old male patient who underwent surgery for the primary obstructive megaureter on the left using a robot-assisted technique. The preoperative left ureteral diameter was 13.5 mm. A radionuclide renal scan revealed an obstructive urinary excretion curve in the left kidney and decreased differentiated renal function on the left side up to 30%. The extravesical ureteral reimplantation technique previously proposed by M. Lopez was used. Surgery was uneventful. A drainage tube was removed on the second postoperative day. A ureteral stent was removed one month after the surgery. After the surgery, the child was monitored closely for 6 months. No serious complications, such as symptom recurrence or development of vesicoureteral reflux, were detected. The distal ureteral diameter decreased to 8 mm. Renal scintigraphy showed a non-obstructive pattern and improved differentiated renal function by 40%. In their work, the authors evaluated clinical efficacy of robotic-assisted laparoscopic reimplantation of the ureter in the primary obstructive megaureter in children: surgery is a safe and effective curative option for congenital structural disorders of the distal ureter. However, larger randomized prospective studies and long-term follow-up are needed to confirm the effectiveness of this technique.
- 21 January 2026
- Published by ECO-Vector LLC (Publications) in Russian Journal of Pediatric Surgery
- Vol. 29 (6) , 414-421
Robot-assisted laparoscopic extravesical ureteral reimplantation in a child with primary obstructive megaureter: а case report
The primary obstructive megaureter accounts for approximately 10% of all uropathies. The overall primary obstructive megaureter incidence is 1:2000 newborns. About 80% of perinatally diagnosed cases of primary obstructive megaureter resolve spontaneously during the first years of a child's life, and therefore most cases of the disease are subject to conservative treatment. Increasing obstruction and decreased renal function are indications for surgical treatment. The present article describes a case of 8 years old male patient who underwent surgery for the primary obstructive megaureter on the left using a robot-assisted technique. The preoperative left ureteral diameter was 13.5 mm. A radionuclide renal scan revealed an obstructive urinary excretion curve in the left kidney and decreased differentiated renal function on the left side up to 30%. The extravesical ureteral reimplantation technique previously proposed by M. Lopez was used. Surgery was uneventful. A drainage tube was removed on the second postoperative day. A ureteral stent was removed one month after the surgery. After the surgery, the child was monitored closely for 6 months. No serious complications, such as symptom recurrence or development of vesicoureteral reflux, were detected. The distal ureteral diameter decreased to 8 mm. Renal scintigraphy showed a non-obstructive pattern and improved differentiated renal function by 40%. In their work, the authors evaluated clinical efficacy of robotic-assisted laparoscopic reimplantation of the ureter in the primary obstructive megaureter in children: surgery is a safe and effective curative option for congenital structural disorders of the distal ureter. However, larger randomized prospective studies and long-term follow-up are needed to confirm the effectiveness of this technique.
- 26 December 2025
- Published by ECO-Vector LLC (Publications) in Russian Journal of Pediatric Surgery, Anesthesia and Intensive Care
- Vol. 15 (4) , 571-582
History of robotics in surgery
The pioneering projects aimed at integrating automated devices into surgical practice date back to the late 1960s. However, the transition from concept to a mass-produced product took nearly three decades. Today, the da Vinci platform (Intuitive Surgical Inc., USA) dominates the global medical community as a system for performing minimally invasive procedures. Importantly, its success was preceded by the development of earlier prototypes, including ZEUS, AESOP, ROBODOC, and the Green Telepresence System. Notably, the original purpose of these technological innovations was not commercial medicine but rather the provision of surgical care under field conditions, including battlefield settings. The research groundwork established with the participation of SRI International and the Advanced Research Projects Agency was later transferred to the private sector. The subsequent consolidation of multiple market players ultimately led to the formation of Intuitive Surgical Inc. This article reconstructs the complete chronology of the development of surgical robots. The methodology includes a meticulous analysis of archival data and scientific publications, as well as direct interviews with leading experts in the field of minimally invasive techniques. Such work is essential, as robotic interventions are currently evolving from an experimental approach into a widely accepted clinical standard, which necessitates a comprehensive understanding of the path already taken.
- 26 December 2025
- Published by ECO-Vector LLC (Publications) in Russian Journal of Pediatric Surgery, Anesthesia and Intensive Care
- Vol. 15 (4) , 571-582
History of robotics in surgery
The pioneering projects aimed at integrating automated devices into surgical practice date back to the late 1960s. However, the transition from concept to a mass-produced product took nearly three decades. Today, the da Vinci platform (Intuitive Surgical Inc., USA) dominates the global medical community as a system for performing minimally invasive procedures. Importantly, its success was preceded by the development of earlier prototypes, including ZEUS, AESOP, ROBODOC, and the Green Telepresence System. Notably, the original purpose of these technological innovations was not commercial medicine but rather the provision of surgical care under field conditions, including battlefield settings. The research groundwork established with the participation of SRI International and the Advanced Research Projects Agency was later transferred to the private sector. The subsequent consolidation of multiple market players ultimately led to the formation of Intuitive Surgical Inc. This article reconstructs the complete chronology of the development of surgical robots. The methodology includes a meticulous analysis of archival data and scientific publications, as well as direct interviews with leading experts in the field of minimally invasive techniques. Such work is essential, as robotic interventions are currently evolving from an experimental approach into a widely accepted clinical standard, which necessitates a comprehensive understanding of the path already taken.