Penghai Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Penghai Li has a total of 51 co-authors. Here are the top co-authors by number of shared publications:
- Abdelkader Nasreddine Belkacem
Department of Computer and Network Engineering, College of Information Technology, UAE University, Al Ain, United Arab Emirates
4 shared publications - Chao Chen
Department of Biomedical Engineering, Medical School of Tianjin University, Tianjin University
3 shared publications Longlong Cheng
China Electronics Cloud Brain (Tianjin) Technology Co., Ltd., Tianjin, People’s Republic of China
3 shared publications- Changming Wang
Beijing Luhe Hospital, Capital Medical University, Beijing, China
2 shared publications Ding Yuan
China Electronics Cloud Brain (Tianjin) Technology Co., Ltd., 12/F, Haitian Building, No. 6, Mei Yuan Road, Huayuan Industrial Park, Binhai High-tech District, Tianjin, China, Tianjin, 30072, CHINA
2 shared publicationsDongfang Yu
School of Medicine, Tianjin University, Weijin Road Campus: No. 92 Weijin Road, Nankai District, Tianjin 300072, Tianjin, Tianjin, 300072, CHINA
2 shared publications
Latest Publications
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Consumer Electronics
- Vol. 72 (4) , 10589-10597
A 0.05-Hz~150-Hz Bandwidth, 0.215- μ Vrms Input-Referred-Noise Three-Opamp Instrumentation Amplifier for Consumer Bio-Signal Acquisition
This paper proposes a chopper-stabilized three-opamp IA with an active high-pass filter (HPF) for biological signal acquisition. An equivalent resistance amplification technique is employed to construct a second-order high-pass filtering network, which significantly reduces the area on the chip occupied by resistors and capacitors and improves the level of circuit integration. In addition, an improved chopper modulation architecture is adopted to realize low-frequency noise and offset suppression, thus enabling high-precision signal acquisition. The proposed IA is fabricated in a standard 180 nm CMOS process. Under a 3.3 V supply voltage, the power consumption is only 1.281 mW. Leveraging the inherent high-frequency gain roll-off characteristic of the operational amplifier, the designed IA achieves a -3 dB bandwidth of 0.05 Hz to 20 kHz, which fully covers the frequency range of mainstream bioelectronic signals such as electrocardiogram (ECG) and electroencephalogram (EEG). Measurements results show that IA achieves a noise of 28.524 nV/ √ Hz @100 Hz, a common-mode rejection ratio (CMRR) as high as 100 dB, and an input impedance of 13.3 GΩ @100 Hz. Meanwhile, it provides a highly accurate adjustable gain with a maximum value of 1000. The input-referred noise (IRN) of this IA is 0.182 μVrms within the 0.5–100 Hz and 0.215 μVrms within the 0.05–150 Hz, achieving competitive noise efficiency factor (3.20) and power efficiency factor (33.79).
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Consumer Electronics
- Vol. 72 (4) , 10589-10597
A 0.05-Hz~150-Hz Bandwidth, 0.215- μ Vrms Input-Referred-Noise Three-Opamp Instrumentation Amplifier for Consumer Bio-Signal Acquisition
This paper proposes a chopper-stabilized three-opamp IA with an active high-pass filter (HPF) for biological signal acquisition. An equivalent resistance amplification technique is employed to construct a second-order high-pass filtering network, which significantly reduces the area on the chip occupied by resistors and capacitors and improves the level of circuit integration. In addition, an improved chopper modulation architecture is adopted to realize low-frequency noise and offset suppression, thus enabling high-precision signal acquisition. The proposed IA is fabricated in a standard 180 nm CMOS process. Under a 3.3 V supply voltage, the power consumption is only 1.281 mW. Leveraging the inherent high-frequency gain roll-off characteristic of the operational amplifier, the designed IA achieves a -3 dB bandwidth of 0.05 Hz to 20 kHz, which fully covers the frequency range of mainstream bioelectronic signals such as electrocardiogram (ECG) and electroencephalogram (EEG). Measurements results show that IA achieves a noise of 28.524 nV/ √ Hz @100 Hz, a common-mode rejection ratio (CMRR) as high as 100 dB, and an input impedance of 13.3 GΩ @100 Hz. Meanwhile, it provides a highly accurate adjustable gain with a maximum value of 1000. The input-referred noise (IRN) of this IA is 0.182 μVrms within the 0.5–100 Hz and 0.215 μVrms within the 0.05–150 Hz, achieving competitive noise efficiency factor (3.20) and power efficiency factor (33.79).
- 26 January 2026
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 23 (1)
Theoretical and applied research on spatio-temporal graph attention networks for single-trial P300 detection
Objective: Accurate detection of single-trial P300 ERPs (event-related potentials) is crucial for developing high-performance non-invasive BCIs (brain-computer interfaces). However, this task remains challenging because of the low SNR (signal-to-noise ratio) of EEG (electroencephalography) and the limited ability of existing models to concurrently capture the complex non-Euclidean spatiotemporal dynamics of brain signals. Approach: We propose a novel ST-GraphTRNet (spatiotemporal graph transformer network). This architecture synergis-tically integrates temporal convolutions for local feature extraction, graph convolutions to explicitly model the neurophysio-logical spatial relationships between EEG electrodes, and a temporal transformer with a self-attention mechanism to capture global, long-range temporal dependencies across the entire signal. Main Results: Extensive evaluation of four public P300 datasets demonstrates that ST-GraphTRNet significantly outper-forms SOTA (state-of-the-art) benchmarks under both within-subject and cross-subject paradigms. Crucially, interpretability analyses via t-SNE (T-distributed Stochastic Neighbor Embedding) and Grad-CAM (Gradient-weighted Class Activation Mapping) revealed that the model’s decisions aligned with established neurophysiological priors, focusing on parietal elec-trodes approximately 300 ms post-stimulus. Significance: This study provides a powerful and interpretable framework for single-trial ERPs decoding. By effectively integrating the strengths of CNNs (Convolutional Neural Networks), GNNs (Craph Neural Networks), and Transformers, a new benchmark for building high-accuracy, generalizable, and clinically viable BCIs is established, moving closer to the goal of plug-and-play systems that require minimal user-specific calibration.
- 26 January 2026
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 23 (1)
Theoretical and applied research on spatio-temporal graph attention networks for single-trial P300 detection
Objective: Accurate detection of single-trial P300 ERPs (event-related potentials) is crucial for developing high-performance non-invasive BCIs (brain-computer interfaces). However, this task remains challenging because of the low SNR (signal-to-noise ratio) of EEG (electroencephalography) and the limited ability of existing models to concurrently capture the complex non-Euclidean spatiotemporal dynamics of brain signals. Approach: We propose a novel ST-GraphTRNet (spatiotemporal graph transformer network). This architecture synergis-tically integrates temporal convolutions for local feature extraction, graph convolutions to explicitly model the neurophysio-logical spatial relationships between EEG electrodes, and a temporal transformer with a self-attention mechanism to capture global, long-range temporal dependencies across the entire signal. Main Results: Extensive evaluation of four public P300 datasets demonstrates that ST-GraphTRNet significantly outper-forms SOTA (state-of-the-art) benchmarks under both within-subject and cross-subject paradigms. Crucially, interpretability analyses via t-SNE (T-distributed Stochastic Neighbor Embedding) and Grad-CAM (Gradient-weighted Class Activation Mapping) revealed that the model’s decisions aligned with established neurophysiological priors, focusing on parietal elec-trodes approximately 300 ms post-stimulus. Significance: This study provides a powerful and interpretable framework for single-trial ERPs decoding. By effectively integrating the strengths of CNNs (Convolutional Neural Networks), GNNs (Craph Neural Networks), and Transformers, a new benchmark for building high-accuracy, generalizable, and clinically viable BCIs is established, moving closer to the goal of plug-and-play systems that require minimal user-specific calibration.
- Open Access
- 21 May 2025
- Published by Frontiers Media SA in Frontiers in Human Neuroscience
- Vol. 19, 1545492
Influence of attentional state on EEG-based motor imagery of lower limb
Introduction: Motor imagery (MI) has emerged as a promising technique for enhancing motor skill acquisition and facilitating neural adaptation training. Attention plays a key role in regulating the neural mechanisms underlying MI. This study aims to investigate how attentional states modulate EEG-based lower-limb motor imagery performance by influencing event-related desynchronization (ERD) and the alpha modulation index (AMI) and to develop a real-time attention monitoring method based on the theta/beta ratio (TBR).Methods: Fourteen healthy right-handed subjects (aged 21–23) performed right-leg MI tasks, while their attentional states were modulated via a key-press paradigm. EEG signals were recorded using a 32-channel system and preprocessed with independent component analysis (ICA) to remove artifacts. Attentional states were quantified using both the traditional offline AMI and the real-time TBR index, with time–frequency analysis applied to assess ERD and its relationship with attention.Results: The results indicated a significant increase in ERD during high attentional states compared to low attentional states, with AMI values showing a strong positive correlation with ERD (r = 0.9641, p < 0.01). Cluster-based permutation testing confirmed that this α-band ERD difference was significant (corrected p < 0.05). Moreover, the TBR index proved to be an effective real-time metric, decreasing significantly under focused attention. Offline paired t-tests showed a significant TBR reduction [t(13) = 5.12, p = 2.4 × 10−5], and online analyses further validated second-by-second discrimination (Bonferroni-corrected p < 0.01). These findings confirm the feasibility and efficacy of TBR for real-time attention monitoring and suggest that enhanced attentional focus during lower-limb MI can improve signal quality and overall performance.Conclusion: This study reveals that attentional states significantly influence the neural efficiency of lower-limb motor imagery by modulating ERD/AMI and demonstrates that the TBR can serve as a real-time indicator of attention, providing a novel tool for optimizing attentional processes in motor skill training.
- 21 May 2025
- Published by Frontiers Media SA in Frontiers in Human Neuroscience
- Vol. 19, 1545492
Open AccessInfluence of attentional state on EEG-based motor imagery of lower limb
Introduction: Motor imagery (MI) has emerged as a promising technique for enhancing motor skill acquisition and facilitating neural adaptation training. Attention plays a key role in regulating the neural mechanisms underlying MI. This study aims to investigate how attentional states modulate EEG-based lower-limb motor imagery performance by influencing event-related desynchronization (ERD) and the alpha modulation index (AMI) and to develop a real-time attention monitoring method based on the theta/beta ratio (TBR).Methods: Fourteen healthy right-handed subjects (aged 21–23) performed right-leg MI tasks, while their attentional states were modulated via a key-press paradigm. EEG signals were recorded using a 32-channel system and preprocessed with independent component analysis (ICA) to remove artifacts. Attentional states were quantified using both the traditional offline AMI and the real-time TBR index, with time–frequency analysis applied to assess ERD and its relationship with attention.Results: The results indicated a significant increase in ERD during high attentional states compared to low attentional states, with AMI values showing a strong positive correlation with ERD (r = 0.9641, p < 0.01). Cluster-based permutation testing confirmed that this α-band ERD difference was significant (corrected p < 0.05). Moreover, the TBR index proved to be an effective real-time metric, decreasing significantly under focused attention. Offline paired t-tests showed a significant TBR reduction [t(13) = 5.12, p = 2.4 × 10−5], and online analyses further validated second-by-second discrimination (Bonferroni-corrected p < 0.01). These findings confirm the feasibility and efficacy of TBR for real-time attention monitoring and suggest that enhanced attentional focus during lower-limb MI can improve signal quality and overall performance.Conclusion: This study reveals that attentional states significantly influence the neural efficiency of lower-limb motor imagery by modulating ERD/AMI and demonstrates that the TBR can serve as a real-time indicator of attention, providing a novel tool for optimizing attentional processes in motor skill training.
- 8 November 2024
- Published by Springer Nature in Biomedical Engineering Letters
- Vol. 15 (1) , 217-227
A high performance heterogeneous hardware architecture for brain computer interface
Brain–computer interface (BCI) has been widely used in human–computer interaction. The introduction of artificial intelligence has further improved the performance of BCI system. In recent years, the development of BCI has gradually shifted from personal computers to embedded devices, which boasts lower power consumption and smaller size, but at the cost of limited device resources and computing speed, thus can hardly improve the support of complex algorithms. This paper proposes a heterogeneous BCI architecture based on ARM + FPGA, enabling real-time processing of electroencephalogram (EEG) signals. Adopting data quantization, layer fusion and data augmentation to optimize the compact neural network model EEGNet, and design dedicated hardware engines to accelerate the network. Experimental results show that the system achieves 93.3% classification accuracy for steady-state visual evoked potential signals, with a time delay of 0.2 ms per trail, and a power consumption of approximately (1.91 W). That is 31.5 times faster acceleration is realized at the cost of only 0.7% lower accuracy compared with the conventional processor. The results show that the BCI architecture proposed in this study has strong practicability and high research significance.
- 8 November 2024
- Published by Springer Nature in Biomedical Engineering Letters
- Vol. 15 (1) , 217-227
A high performance heterogeneous hardware architecture for brain computer interface
Brain–computer interface (BCI) has been widely used in human–computer interaction. The introduction of artificial intelligence has further improved the performance of BCI system. In recent years, the development of BCI has gradually shifted from personal computers to embedded devices, which boasts lower power consumption and smaller size, but at the cost of limited device resources and computing speed, thus can hardly improve the support of complex algorithms. This paper proposes a heterogeneous BCI architecture based on ARM + FPGA, enabling real-time processing of electroencephalogram (EEG) signals. Adopting data quantization, layer fusion and data augmentation to optimize the compact neural network model EEGNet, and design dedicated hardware engines to accelerate the network. Experimental results show that the system achieves 93.3% classification accuracy for steady-state visual evoked potential signals, with a time delay of 0.2 ms per trail, and a power consumption of approximately (1.91 W). That is 31.5 times faster acceleration is realized at the cost of only 0.7% lower accuracy compared with the conventional processor. The results show that the BCI architecture proposed in this study has strong practicability and high research significance.
- Open Access
- 10 January 2024
- Published by Frontiers Media SA in Frontiers in Neuroscience
- Vol. 17, 1330077
Attention-based 3D convolutional recurrent neural network model for multimodal emotion recognition
Introduction: Multimodal emotion recognition has become a hot topic in human-computer interaction and intelligent healthcare fields. However, combining information from different human different modalities for emotion computation is still challenging.Methods: In this paper, we propose a three-dimensional convolutional recurrent neural network model (referred to as 3FACRNN network) based on multimodal fusion and attention mechanism. The 3FACRNN network model consists of a visual network and an EEG network. The visual network is composed of a cascaded convolutional neural network–time convolutional network (CNN-TCN). In the EEG network, the 3D feature building module was added to integrate band information, spatial information and temporal information of the EEG signal, and the band attention and self-attention modules were added to the convolutional recurrent neural network (CRNN). The former explores the effect of different frequency bands on network recognition performance, while the latter is to obtain the intrinsic similarity of different EEG samples.Results: To investigate the effect of different frequency bands on the experiment, we obtained the average attention mask for all subjects in different frequency bands. The distribution of the attention masks across the different frequency bands suggests that signals more relevant to human emotions may be active in the high frequency bands γ (31–50 Hz). Finally, we try to use the multi-task loss function Lc to force the approximation of the intermediate feature vectors of the visual and EEG modalities, with the aim of using the knowledge of the visual modalities to improve the performance of the EEG network model. The mean recognition accuracy and standard deviation of the proposed method on the two multimodal sentiment datasets DEAP and MAHNOB-HCI (arousal, valence) were 96.75 ± 1.75, 96.86 ± 1.33; 97.55 ± 1.51, 98.37 ± 1.07, better than those of the state-of-the-art multimodal recognition approaches.Discussion: The experimental results show that starting from the multimodal information, the facial video frames and electroencephalogram (EEG) signals of the subjects are used as inputs to the emotion recognition network, which can enhance the stability of the emotion network and improve the recognition accuracy of the emotion network. In addition, in future work, we will try to utilize sparse matrix methods and deep convolutional networks to improve the performance of multimodal emotion networks.
- 10 January 2024
- Published by Frontiers Media SA in Frontiers in Neuroscience
- Vol. 17, 1330077
Open AccessAttention-based 3D convolutional recurrent neural network model for multimodal emotion recognition
Introduction: Multimodal emotion recognition has become a hot topic in human-computer interaction and intelligent healthcare fields. However, combining information from different human different modalities for emotion computation is still challenging.Methods: In this paper, we propose a three-dimensional convolutional recurrent neural network model (referred to as 3FACRNN network) based on multimodal fusion and attention mechanism. The 3FACRNN network model consists of a visual network and an EEG network. The visual network is composed of a cascaded convolutional neural network–time convolutional network (CNN-TCN). In the EEG network, the 3D feature building module was added to integrate band information, spatial information and temporal information of the EEG signal, and the band attention and self-attention modules were added to the convolutional recurrent neural network (CRNN). The former explores the effect of different frequency bands on network recognition performance, while the latter is to obtain the intrinsic similarity of different EEG samples.Results: To investigate the effect of different frequency bands on the experiment, we obtained the average attention mask for all subjects in different frequency bands. The distribution of the attention masks across the different frequency bands suggests that signals more relevant to human emotions may be active in the high frequency bands γ (31–50 Hz). Finally, we try to use the multi-task loss function Lc to force the approximation of the intermediate feature vectors of the visual and EEG modalities, with the aim of using the knowledge of the visual modalities to improve the performance of the EEG network model. The mean recognition accuracy and standard deviation of the proposed method on the two multimodal sentiment datasets DEAP and MAHNOB-HCI (arousal, valence) were 96.75 ± 1.75, 96.86 ± 1.33; 97.55 ± 1.51, 98.37 ± 1.07, better than those of the state-of-the-art multimodal recognition approaches.Discussion: The experimental results show that starting from the multimodal information, the facial video frames and electroencephalogram (EEG) signals of the subjects are used as inputs to the emotion recognition network, which can enhance the stability of the emotion network and improve the recognition accuracy of the emotion network. In addition, in future work, we will try to utilize sparse matrix methods and deep convolutional networks to improve the performance of multimodal emotion networks.
- 7 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Consumer Electronics
- Vol. 70 (1) , 2423-2434
Attention-Based Multiscale Spatial-Temporal Convolutional Network for Motor Imagery EEG Decoding
Motor imagery (MI) electroencephalography (EEG) has been used in consumer products supported by brain-computer interfaces (BCI), with existing electronics covering a wide range of domains from artificial intelligence (AI) to the Internet of Things (IoT). However, the limitation in decoding MI-EEG signals has restricted the further development of the related Consumer Electronics (CE) industry. To address this problem, this paper proposes an attention-based multiscale spatial-temporal convolu-tional network (AMSTCNet). First, a multi-branch structure is designed to extract high-dimensional spatial-temporal represent-tations at different scales. Second, Squeeze-Excite-Compress (SEC) blocks are proposed to highlight feature responses within a single scale and weighted to fuse these features to reduce information redundancy. Finally, the attention-based temporal convolutional network is used to obtain deep temporal information of the signal to dynamically fuse features at different scales. In addition, the AMSTCNet model is an end-to-end decoder using raw EEG signals as input. We evaluated the decoding performance of the AMSTCNet model using the BCI IV 2a dataset and the High Gamma dataset, and achieved recognition accuracies of 87.55% and 96.35%, respectively. Compared with existing methods, our method achieves satisfactory decoding performance and can greatly facilitate the application of BCI technology in CE.
- 7 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Consumer Electronics
- Vol. 70 (1) , 2423-2434
Attention-Based Multiscale Spatial-Temporal Convolutional Network for Motor Imagery EEG Decoding
Motor imagery (MI) electroencephalography (EEG) has been used in consumer products supported by brain-computer interfaces (BCI), with existing electronics covering a wide range of domains from artificial intelligence (AI) to the Internet of Things (IoT). However, the limitation in decoding MI-EEG signals has restricted the further development of the related Consumer Electronics (CE) industry. To address this problem, this paper proposes an attention-based multiscale spatial-temporal convolu-tional network (AMSTCNet). First, a multi-branch structure is designed to extract high-dimensional spatial-temporal represent-tations at different scales. Second, Squeeze-Excite-Compress (SEC) blocks are proposed to highlight feature responses within a single scale and weighted to fuse these features to reduce information redundancy. Finally, the attention-based temporal convolutional network is used to obtain deep temporal information of the signal to dynamically fuse features at different scales. In addition, the AMSTCNet model is an end-to-end decoder using raw EEG signals as input. We evaluated the decoding performance of the AMSTCNet model using the BCI IV 2a dataset and the High Gamma dataset, and achieved recognition accuracies of 87.55% and 96.35%, respectively. Compared with existing methods, our method achieves satisfactory decoding performance and can greatly facilitate the application of BCI technology in CE.
- 22 August 2023
- Published by Springer Nature in Optoelectronics Letters
- Vol. 19 (8) , 506-512
Research on EEG emotion recognition based on CNN+BiLSTM+self-attention model
- 22 August 2023
- Published by Springer Nature in Optoelectronics Letters
- Vol. 19 (8) , 506-512
Research on EEG emotion recognition based on CNN+BiLSTM+self-attention model
- Open Access
- 22 February 2023
- Published by Frontiers Media SA in Frontiers in Neuroscience
- Vol. 17, 1132290
Single-trial P300 classification algorithm based on centralized multi-person data fusion CNN
Introduction: Currently, it is still a challenge to detect single-trial P300 from electroencephalography (EEG) signals. In this paper, to address the typical problems faced by existing single-trial P300 classification, such as complex, time-consuming and low accuracy processes, a single-trial P300 classification algorithm based on multiplayer data fusion convolutional neural network (CNN) is proposed to construct a centralized collaborative brain-computer interfaces (cBCI) for fast and highly accurate classification of P300 EEG signals.Methods: In this paper, two multi-person data fusion methods (parallel data fusion and serial data fusion) are used in the data pre-processing stage to fuse multi-person EEG information stimulated by the same task instructions, and then the fused data is fed as input to the CNN for classification. In building the CNN network for single-trial P300 classification, the Conv layer was first used to extract the features of single-trial P300, and then the Maxpooling layer was used to connect the Flatten layer for secondary feature extraction and dimensionality reduction, thereby simplifying the computation. Finally batch normalisation is used to train small batches of data in order to better generalize the network and speed up single-trial P300 signal classification.Results: In this paper, the above new algorithms were tested on the Kaggle dataset and the Brain-Computer Interface (BCI) Competition III dataset, and by analyzing the P300 waveform features and EEG topography and the four standard evaluation metrics, namely Accuracy, Precision, Recall and F1-score,it was demonstrated that the single-trial P300 classification algorithm after two multi-person data fusion CNNs significantly outperformed other classification algorithms.Discussion: The results show that the single-trial P300 classification algorithm after two multi-person data fusion CNNs significantly outperformed the single-person model, and that the single-trial P300 classification algorithm with two multi-person data fusion CNNs involves smaller models, fewer training parameters, higher classification accuracy and improves the overall P300-cBCI classification rate and actual performance more effectively with a small amount of sample information compared to other algorithms.
- 22 February 2023
- Published by Frontiers Media SA in Frontiers in Neuroscience
- Vol. 17, 1132290
Open AccessSingle-trial P300 classification algorithm based on centralized multi-person data fusion CNN
Introduction: Currently, it is still a challenge to detect single-trial P300 from electroencephalography (EEG) signals. In this paper, to address the typical problems faced by existing single-trial P300 classification, such as complex, time-consuming and low accuracy processes, a single-trial P300 classification algorithm based on multiplayer data fusion convolutional neural network (CNN) is proposed to construct a centralized collaborative brain-computer interfaces (cBCI) for fast and highly accurate classification of P300 EEG signals.Methods: In this paper, two multi-person data fusion methods (parallel data fusion and serial data fusion) are used in the data pre-processing stage to fuse multi-person EEG information stimulated by the same task instructions, and then the fused data is fed as input to the CNN for classification. In building the CNN network for single-trial P300 classification, the Conv layer was first used to extract the features of single-trial P300, and then the Maxpooling layer was used to connect the Flatten layer for secondary feature extraction and dimensionality reduction, thereby simplifying the computation. Finally batch normalisation is used to train small batches of data in order to better generalize the network and speed up single-trial P300 signal classification.Results: In this paper, the above new algorithms were tested on the Kaggle dataset and the Brain-Computer Interface (BCI) Competition III dataset, and by analyzing the P300 waveform features and EEG topography and the four standard evaluation metrics, namely Accuracy, Precision, Recall and F1-score,it was demonstrated that the single-trial P300 classification algorithm after two multi-person data fusion CNNs significantly outperformed other classification algorithms.Discussion: The results show that the single-trial P300 classification algorithm after two multi-person data fusion CNNs significantly outperformed the single-person model, and that the single-trial P300 classification algorithm with two multi-person data fusion CNNs involves smaller models, fewer training parameters, higher classification accuracy and improves the overall P300-cBCI classification rate and actual performance more effectively with a small amount of sample information compared to other algorithms.
- 29 November 2022
- Published by Springer Nature
- p. 125-134
Brain Network Analysis of Hand Motor Execution and Imagery Based on Conditional Granger Causality
- 29 November 2022
- Published by Springer Nature
- p. 125-134
Brain Network Analysis of Hand Motor Execution and Imagery Based on Conditional Granger Causality
- Open Access
- 17 November 2022
- Published by Association for Computing Machinery (ACM)
- p. 439-446
Comparative Study on EEG Feature Recognition based on Deep Belief Network
In Brain Computer interface (BCI) system, motor imagination has some problems, such as difficulty in extracting EEG signal features, low accuracy of classification and recognition, long training time and gradient saturation in feature classification based on traditional deep neural network, etc. In this paper, a deep belief network (DBN) model is proposed. Fast Fourier transform (FFT) and wavelet transform (WT) combined with deep machine learning model DBN were used to extract the feature vectors of time-frequency signals of different leads, superposition and average them, and then perform classification experiments. The number of DBN network layers and the number of neurons in each layer were determined by iteration. Through the reverse fine-tuning, the optimal weight coefficient W and the paranoid term B are determined layer by layer, and the training and optimization problems of deep neural networks are solved. In this paper, a motion imagination and Motion observation (MI-AO) experiment is designed, which can be obtained by comparing with the public dataset BCI Competition IV 2a. The DBN model is used to compare with other algorithms, and the average accuracy of binary classification is 83.81%, and the average accuracy of four classification is 80.77%.
- 17 November 2022
- Published by Association for Computing Machinery (ACM)
- p. 439-446
Open AccessComparative Study on EEG Feature Recognition based on Deep Belief Network
In Brain Computer interface (BCI) system, motor imagination has some problems, such as difficulty in extracting EEG signal features, low accuracy of classification and recognition, long training time and gradient saturation in feature classification based on traditional deep neural network, etc. In this paper, a deep belief network (DBN) model is proposed. Fast Fourier transform (FFT) and wavelet transform (WT) combined with deep machine learning model DBN were used to extract the feature vectors of time-frequency signals of different leads, superposition and average them, and then perform classification experiments. The number of DBN network layers and the number of neurons in each layer were determined by iteration. Through the reverse fine-tuning, the optimal weight coefficient W and the paranoid term B are determined layer by layer, and the training and optimization problems of deep neural networks are solved. In this paper, a motion imagination and Motion observation (MI-AO) experiment is designed, which can be obtained by comparing with the public dataset BCI Competition IV 2a. The DBN model is used to compare with other algorithms, and the average accuracy of binary classification is 83.81%, and the average accuracy of four classification is 80.77%.